Loading...
00-0374-013 i01 U U CARLOS FIGUEROA AIR CONDITIONING SCHEDULE n>FZC>Frrr�cr UNIT MANUFACTURER NOM. NOM. ESP IN. ELECT. TOTAL COOLING CAP. S/T O/A DIMENSIONS WEIGHT ELECT. SERVICE AND MODEL NO, TONS CFM WG. HEAT KW A/NP 13TUH s 95' 4 61' W M(LxN (IN.) LBO, VOLTS/PN/Hz SEER - — _ ___ -- --- --- ---- ----— A/C BART ---- RTU (EXIST) 5 2000 --- _-_ 20a.1 -•- ---- 540 I 60 ?30 / "- NOTES- F-I OUTSIDE AIR CALCULATIONS _ PER ASHRAE &2-89 CUSTOMER AREA O/A REQ'D- 15 CFM/PER 5D PER/1000 FT SQ. A- 540 Ft. $Q. HVAC LEGEND CFM- 50 X D40 X 15. 405 Alzc>Firrt?cruRE 1000 FYI INTERIOR DESIaN BACK RM AREA O/A REQ'D- 15 CPM/FER — '~ EXISTING TENANT >a SUPPLY AIR DIFFUSER AIR CONDITIONING SYSTEM - GENERAL NOTES: ?0 PERA000 FT $Q. A- 44a FT. $Q. O 4081 SW 84th AVEN[JE R MIAMI,FLORIDA 33153 REtURIJ AIR GRILLE I. DUCTWORK SHALL BE 1 I/2" THICK, 3 POUNDS PER CUBIC FOOT DENSITY GPM- 20 X 4�4 XIS■ 134 �O5\`C`T3''ZI(�f1ll�rv��7 FIBEFYsLA58 WITH VAPOR BARRIER, UNLE68 OTHERWISE SPECIFIED. 1000 'fir{U . DUCTWORK SHALL BE FABRICATED AND INSTALLED IN ACCORDANCE TOTAL CFM REQ'D- 539 \ > ";,t ..►► .., T tNEFd-tOBtAt WITH MANUFACTURER'S SPECIFICATIONS AND ACCORDING TO "AWRAE" geaI;; w> AND "$MAGNA" STANDARDS. ► '� SUPPLY AIR DUCT RECTANGULAR GROSS SECTION DUCT DIMENSIONS ARE IN INCHES AND CORRESPOND TO INSIpE 0 DIMENSIONS WIDTH X HEIGHT. DUCT SYSTEM SHALL COMPLY WITH I�tUi�iJ AIR DUCT RECTANGULAR GR083 SECTION °SPA" STANDARD NO. 90A AND/OR 908. DUCTWORK AND COT-ipONI;NtB SHALL BE GLAS$ I MATERIALS IN ACCORDANCE WITH U.L. 181 0 TESTS. PROVIDE FIRE DAMPERS WHEN CROSSING F. RATED WALL OR CEILING. N 1 TURNING VANE HVAC DESIGN REQUIRI=B: Yi=B NO 2. COORDINATE LOCATIONS, SIZES AND OPENINGS WITH OTHER TRADES D�TECtoR i Ducr artoKlr x YO!-UME DAMPER, IN LINE ON THE JOB. A/C CONTRACTOR SHALL PROVIDE THE COMPLETE DUCT SYSTEM A✓C W/TURNING VANES AT ALL ELBOWS, SPLITTERS 4 VOLUME DAMPERS. . FIRE DAMPER (a) x ; ��---- VOLUME DAMPER, At TAKE OFF SMOKE DAM " -- -- PER(S) x 8 ♦SH �'2 � 3. DIFFUSE" WALL BE SELECTED, LOCATED, AND BALANCED IN ORDER EF ® M--� ' THAT THEY DELIVER THE REQUIRI=D C-M t0 THE ENTIRE ROOM EVENLY FIRI: RATED ENG103URE x ,r FLEXIBLE ROUND DUCT AND DRAFT FREE TO MAINTAIN THE FOLLOWING DESIGN CONDITIONS: G� RAT �M O� LOOR ,lip $FLITTER DAMPER RELATIVE CEILING Ar Y x l i X INSIDE �TglpE HM DI — FIRE 9TOFF'ING x /w� COOLING - 16' OB 91' DO • 19' WB 50%, t0 609, �q CONtF2011 x I EXI t. F� HEATING - 10' DB 45' DB 4" FLUE �. CLASS UP TH -- FIRE DAMPER 4. ALL FAN UNITS, MOTORS, COMPF2ESSOR$, I=TC. SHALL BE ISOLATED, A$ REQUIRED t0 OPERATE QUIETLY 80 THAT NOOBJECTIONABLE SOUND ROOF/CAP WILL BE HEARD IN THE HABITABLE SPACES DUE TO AIR VELOCITY, S SMOKE DETECTOR MOTOR HUM, VIBRATION, OR MECHANICAL MOVEMENT. © OPPOSED BLADE DAMPER © a 5. A/C SYSTEM SHALL HAVE CLEANABLE AIR FILTERS LOCATED AS EF"2 -- �, REQUIRED FOR EASY ACCESSIBILITY. -- � � ---- - - - - � --"t- ELECTRIC STRIP HEALER x � 6. A/C SYSTEM SHALL BE CONTROLLED BY A tHEFd"(08tAt. MOUNT MOTORIZED DAMPER TWERM08TAT 5'-0" ABOVE FINISHED FLOOR, U.ON 0 I. ALL GRILLS AND DIFFUSERS t0 BE STEEL CONSTRUCTION. DIFFUSERS t0 - LIYT--� HAVE CEILING RADIANT DAMPERS. PROVIDE GASKEtB ON ALL GRILLE$, ca 14X10 TITUS OR AIREGUIDE OR APPROVED EQUAL WITH ENAMEL FINISH COLOR BY FROM OTHER DETECTOR (6EE PLAN VIEW) ARCHITECT. (IF APPLICABLE) IONIZATION SMOKE DETECTOR (SEE HVAC PLANS) A – „ - ?. UNDERCUT DOORS I" A,FF., AS INDICATED. DETECTOR TEST PANEL METAL PC"FITTMG OR FIRE ALARM PANEL IF APPLICABLE to ou It IN6IILOAr10N S. ALL REFRIGERANT PIPING SHALL BE COPPER - TYPE L - PWER A D v r F+1^ 1°RD1/IDE ATIGN GUARD LIGHT O O U H w1E+Er�NE 'E ACR TYPE, DEHYDRATED AND SEALED. ALL FITTING$ SHALL BE 24 INDICATOR WROUGHT COPPER. ALL JOINT$ SHALL BE MADE WITH HIGH 24 AIR IoW TEMPERATURE BRAZING ALLOY OF NOT LESS THAN 5% SILVER ,m 1 PIPING INSTALLATION NOT LESS THAN 3/4" THICK "ARMAFLEX". OR r 12XIO JJ H LIQUID AND SUCTION LINES WALL BE SIZED ACCORDING TO — (T� AD"TA$LE VOLU-M EQUIPMENT MANUFACTURER'S R1=COMMENDAtIONS FOR EQUIVALENT 120 W Ir18ULATEO ALEX DUCT. D�'ER LENGTH OF PIPING FUN FOR CONNECTED TONNAGE, ALL PIPING VAC 1 "ftk3 ?T4 $TEEL IELENE ACCESSORIES SHALL BE CONSTRUCTED AS SUGGESTED BY EQUIPMENT M S FRElt D STEEL _MANUFAGTURII R ALL PIPING _WALL,ME,�V'ACUATE-Q, rEjjt GOOD �_, _ . - IWRE REI1iORGR4G ... _ .�.,.ll,L,LISTED � _.. .... . . .. . _, _ .AUDIBLE ALARM 6EAl. MOR4t lU1TH PIPING PRACTICE BEFORE $?ART-CIF'. ., _ - p� , O IN NORMALLY EPDXY t DUCT TAPE OCCUPIED AREA PLOW '- OR THROUGH 6 � j I -------------------� � BUILDING FIRE AIR PLOW ALARM SYSTEM I IF APPLICABLE �� M I PERFORATED DIFFUSER � � ( 0 O � F� EAL JOINT TH I O FTC EPDXY 1 DUCT TAPE .. W E D EVAPORATOR FAN ROTOR AUXILIARY TO I I SHUT DOWN CONTACT IN ASE [ l W TYPICAL DIPt=USER CONNECTION DETAIL OF SMOKE SENSING e NO SCALE A AIR I I ® A (� I CONDITIONIW_s DUCT SMOKE DETECTOR C� I A A STANDARD CON6T►211r"tIOtJ Q � FRAMEt STEEL M BLADE INSULATICNt NON-ASBESTOS UL CLASSIFIED µ� FLEX DUCT.STEEL DUCT FINIS-It MILL GALVANIZED OR NO DUCT. FUSIBLE LM REPLAGEABLI= 165'F UL LISTED 6r / LMK 18 STANDARD. 11 2'F I$OPTIONAL. MAXIMUM NZEt 15" DIAMI=TER MINIMUM SIZE: 5" DIAMETER MODEL CRP-1 OR CRD•? CEILtra DAM"-R p�c� CEILR40 A Revl5lon5 ---- — © 04- 18-00 TM-24 —TO-24 CD Tr�rtAL --- ---- —TWE�� GILfNCs RADIATION DAMPER MODEL CRP-2 BLANKET BLAt KLt rIt s. m = 8t EL W RE V o JoIStB FRAME DIMENSIONS ------- --------- ----------- -- — 0 DAMPEER MODEL D A B C E o ' CRD-2 STANDARD FRAME 5"-15" 3 1/16 NA NA NA ° 1 HR FR GRD-1B BOTTOM EXTENSION 5"-15' NA 591 NA NA cv PEEING �D� LAY-IN TYPE STEEL D�FLI6ER � MODELSt CRD•1 AND I;D.2 CRD-2T TOP EXTENSION 5"44" NA NA 1V2 NA o I1"CLEARANCE e9TWEIEN DAP"R THIS INSTALLATION 18 DEEITGNED AND TtstED Ili,".1ey► NA 9V2, Drawn Appr. by FRAME AND DUCT DROFa(TYP-) FOR EITHER STEEL OR FLEX(ROIND)DUCTS "RE THE MEMBIR"F"TRATICN 18 LARGER CRD-26t BOTTOM AND TOP EXT. 5"-1114" NA NA NA 9 1/6, �.(j. M.G. MAXIMUM i�R4e OPENING SIZE 24"X 24"(516 $a INJ THAN THE DUCT SIZE.N e(?--"CA6f8,THE BACK OF THE GRILLE OR DIHIUMR MUST DE PROTECTED Ittz"-15" NA NA NA it 1/e" WITH THE ADDITIGN OF OUR T13-24 THERIAL DILANCET. -- — TT--- -- Date 3/00 G I ING RADIATION DAMPER INSTALLATION REQUIREMENTS THE DAR 6HALL"6U6PE�D At ALL PCUR -- -- j" T COBRA WITH N2 &M3.STEEL M". -- U scale :A5 noted S U Job No. : - 5heet: - c REfLECTIVE CELING PLAN HVAC GUERRERO/GON2ALEZ ��� � " _ SCALE: 1/4 1 -0 ENGINEERS, INC. �.. 1 _ wlcNw wo, P.E. RafW L Gonzalez. P.E. t d Elft Enq Lie. /11037 S.W.00 73rd Ave n e.S2Suite 1107A U kaml. "Orma 306 33'53 Of: - 5heet5 j Tel. ( ) 262-39{4. Fax (305) 262-8211 —. E-maik 001WOACCISSPRO.NET