00-0355-015 o ❑ rRLOS FIGUEROA ' 8 ; 0; 701B 702B 703B 7041 a7n ol 0 GENERAL PLUMBING NOTES i A ------------- I -__----i ARCHITECTURE 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING INTERIOR DESIGN CODE, DADE COUNTY EDITION, AND ALL APPLICABLE LOCAL ORDINANCES. - �; A R 0 0 0 9 8 4 4 2. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR 408o sw 84th AVENUE IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE MIAMI, FLORIDA 33155 305 220 8997 FULLY OPERATIVE. �. - -- 3. PLUMBING CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL PLUMBING WORK SHALL BE FREE OF DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. -- ; --= - •+"""`�� 4. CONTRACTOR SHALL VISIT THE SITE AND FIELD VERIFY LOCATION OF EXISTING / ! ����� `••••••• �L1, �` POINTS OF CONNECTIONS BEFORE SUBMITTING BID AND OBTAIN CLARIFICATION © a9 BEFORE COMMENCING WORK. r B L------------------------------ - ; t >:. 5. CONTRACTOR SHALL BECOME FAMILIAR WITH ALL EXISTING CONDITIONS '� • ''" -� "' U. w AND NOTIFY ARCHITECT/ENGINEER OF ANY DEVIATION DUE TO FIELD l -- -"- ' CONDITIONS BEFORE PERFORMING WORK. ; ' AHU-13: A :t' 711E ? 712B --------- 6. CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL PENETRATIONS 7056 fI '•,, ,�, ,- THROUGH WALLS, CEILINGS, FLOOR AND ROOFS WITH OTHER TRADES AND � ` {,` - p'•4.�,F�: REPORT ANY DISCREPENCIES TO ARCHITECT/ENGINEER. 7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT LOCATION OF FIXTURES AND PIPING. S eta rt _..__ _._ 5 �•_ + 8. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS, TAXES, INSPECTION 1 1/2-01/4- FT AND TEST FEES. --=_-__ ---- PROVIDE A CONDENSATE 9. MATERIALS SHALL BE NEW, FREE OF DEFECTS AND OF AMERICAN +. DRAIN PUMP EQUAL TO LITTLE MoD MANUFACTURE, AS FOLLOWS: 7 GIANT VCM 15UL-50GPH ® 5'EE TDH-115V/1-/60 30 AMP A. ABOVE GROUND WASTE AND VENT PIPING SHALL BE BELL AND SPIGOT (SUPPORT FROM WALL ABOVE OR "NO HUB" STANDARD WEIGHT CAST IRON, WROUGHT IRON OR COPPER _ —_._ _:__ - _._-_ CEILING) PIPE. IF PERMITTED BY GOVERNING CODES AND ACCEPTED BY OWNER, . SCHEDULE 40 ABS OR (DWV) PVC MAY BE USED. ( C -------------------------------- CONNECT TO EXISTING C I CONDENSATE DRAIN B. WASTE PIPING SHALL BE BELL AND SPIGOT STANDARD WEIGHT \ -' / 70 BB PIPING IN MECHANICAL ROOM CAST IRON, WROUGHT IRON OR COPPER PIPE. IF PERMITTED BY GOVERNING I 713B CODES AND ACCEPTED BY OWNER, SCHEDULE 40 ABS OR (DWV) PVC MAYBE USED IN LIEU OF CAST IRON. C. WATER PIPING: COPPER TYPE "L" WITH ASTM B-16, LEAD-FREE SOLDER. use E- D. WALL CLEANOUTS: JOSAM SERIES 58750 WITH ACCESS COVER OR �� � x EQUAL. --- f" E. VALVES: 125 PSI NIBCO SCOTT, STOCKHAM OR EQUAL. 7osB a 10. PERFORM THE FOLLOWING TESTS: D ------ - - - - ,- A. NEW WATER PIPING SHALL BE HYDROSTATICALLY TESTED AT 100 PSIG FOR A PERIOD OF NO LESS THAN ONE HOUR. s B. WASTE AND VENT PIPING SHALL BE FILLED WITH WATER TO A 10 FOOT " I d� HEAD AND ALLOWED TO STAND UNTIL THE WATER LEVEL REMAINS CONSTANT. _ C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTING. I D. STERILIZE ALL NEW WATER PIPING WITH A MIXTURE OF TWO (2) POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPE FOR A PERIOD OF 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE E.. �-1 WATER BEFORE PLACING SYSTEM IN SERVICE. 11. WASTE PIPING 2" AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPES LARGER THAN 2" SHALL BE SLOPED AT 1/8" PER FOOT MINIMUM FALL. ANY DEVIATION SHALL BE APPROVED BY ARCHITECT/ENGINEER. `I 12. INSULATE ALL AIR CONDITIONING AND REFRIGERATION CONDENSATE w DRAIN WITH 3/4" INCOAFLEX. FINISHED WHERE EXPOSED WITH 2 COATS I '� OF WHITE LATEX PAINT ALL AS PER MANUFACTURER'S INSTRUCTION. 1--•I 13. PIPING PENETRATIONS AT ROOFS, CEILINGS, FLOORS AND WALL SHALL W BE SEALED AIR AND WATER TIGHT. WHERE PENETRATING FIRE RATED 1--•I CONSTRUCTION, FIRE SAFED TO PROVIDE PROTECTION MATCHING F--1 REQUIRED RATING. 14. ALL VENT PIPING SHALL BE SO GRADED AND CONNECTED AS TO DRAIN N 7TH FLOOR PLUMBING PLAN AREA B E4 DRY. NO POCKETS OR LOW POINTS SHALL BE CREATED IN THE VENT LINES _ _ W F--1 WHICH MAY PREVENT VENTING IF FILLED WITH CONDENSATION. SCALE. /H�� O" U� 15. CEILING ACCESS PANELS SHALL BE PROVIDED FOR VALVES INSTALLED 12 13 ABOVE OTHERWISE NON-ACCESSIBLE CEILINGS. 1 2 3 16. PRECAUTIONS SHALL BE TAKEN TO PREVENT CONTAMINATION OF OWNER 2' MIN 3' 4 EQUIPMENT, FURNITURE AND CARPETING WITHIN THIS BUILDING. ALL [IUND !� COVER AND WRAP EQUIPMENT, FURNITURE AND CARPETING AS I NECESSARY. DUST AND DEBRIS SHALL BE STRICTLY CONTROLLED. CD O CONDENSATE DRAIN 3/4" MINIMUM TO 10 TONS, 1 1/4" MINIMUM 10 TONS AND OVER. F--1 o CLOSE COORDINATION WITH OWNER WILL BE REQUIRED. �_ �Tl 112' p 17. WHERE REQUIRED, EXISTING CEILINGS SHALL BE REMOVED TO MODIFY © P--TRAP (2" MIN. WATER SEAL MIN. TO 3 TONS, 3" MIN. OVER 3 TONS). THE EXISTING PLUMBING SYSTEMS. THESE CEILINGS SHALL BE SLOPE 1/8' /FT 6 8 4 1 3 10 REPLACED TO MATCH ADJACENT SURFACES. 7 9 O FLOAT SWITCH AUXILIARY DRAIN PAN MIN. 24 GA., GALV. METAL WHERE EQUIPMENT IS CONCEALED. OREMOVEABLE THREADED PLUG OR DRAIN COCK WHEN FLOAT SWITCH ONLY Revisions NOTES ALT. PROVIDED. 10 AUXILIARY PAN DRAIN 3/4" MINIMUM. OREFER TO PLAN FOR SIZES. 11 MATERIALS AND INSTALLATION TO BE AS INDICATED AND PER SOUTH OCONDENSATE DRAINS FROM A/C UNITS SHALL BE ADEQUATELY INSULATED IN FLORIDA BUILDING CODE, DADE EDITION AND LOCAL AUTHORITIES. ATTICS AND CRAWL SPACES AND WHEREVER DAMAGE TO PROPERTY OR 1Z REMOVEABLE CAP. EQUIPMENT MAY RESULT FROM SWEATING. OAUX. DRAIN TO TERMINATE OVER CLOSET SINK, LAV., OR OTHER APPOVED UNION (TYPICAL) LOCATION WHERE DISCHARGE WOULD BE NOTICED WITHOUT CAUSING DAMAGE AND/OR HAZARD. TERMINATE FLUSHED WITH CEILING ABOVE EXISTING SERVICE SINK. OFLOAT SWITCH WHEN USED INSTEAD OF OR IN ADDITION TO AUX. PAN DRAIN SHALL BE WIRED TO SHUT DOWN THE AIR CONDITIONING SYSTEM WHEN THE FLOW SWITCH OPENS. A /C UNIT DRAIN PAN 8c CONDENSATE TRAP Job No. Sheet No. P T.S. Date 09/09/99 P — 1 Puga and Associates, Inc. Engineers/Consultants Drawn by # EB 0005813 GSR/GLM 4970 S.W. 72 Avenue, #107 Appr• by Miami, Florida 33155 JDP of (305) 661-7700