Loading...
00-0246-019 y� ) ' 1 ELECTRICAL SYMBOL LEGEND NO. REVISIONS DATE ELECTRICAL GENERAL NOTES LUMINAIRE SCHEDULE BID/PERMIT 2/18/ 1. IT SHALL BE UNDERSTOOD THAT ALL WORK PERFORMED SHALL BE DONE BY A LICENSED D. MARK TERMINATIONS OF TELEPHONE CONDUIT AS DIRECTED BY TELEPHONE all mounting heights to be as shown unless )tr`er,vice noted ELECTRICAL CONTRACTOR AND IN A FIRST CLASS WORKMANLIKE MANNER. SAID COMPANY. DES M7S ny,E VOLTS No. OF LAMPS DESCRIPTION MANUFACTURER CATALOG No. NOTES: L I HTIN „O,XTURES CONTRACTOR SHALL MEET ALL REQUIREMENTS SET FORTH BY ANY LOCAL ORDINANCE E. VERIFY LOCATION OF TELEPHONE SERVICE WITH TELEPHONE COMPANY, PRIOR 70 A R f 120 3f032T8/735 Y 2x4 PARABOLIC COLUMBIA 4524-3.32G-LD363S-EB-GLR AND/OR GOVERNING AUTHORITIES. SUBMITTING BID. B R F 2FB32T8/6/735 2x2 PARABOLIC - 4522-240TTG-LD33S-E88-GLI2 2' X 4' FLUORESCENT CONDUITS. ALL CONDUITS SHALL BE INTERMEDIATE C S F 1F032TS/735 4' WALL MTD. FLUURESCENT LU4-132-EB8-WLGLR - �) 1' X 4' FLUORESCENT 2. ENTIRE INSTALLATION SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL 23. ALL CONDUCTORS SHALL BE IN CON -. CODE, LATEST EDITION NEC AND THE LATEST EDITIONS OF ALL LOCAL CODES, IMC) OR RIGID GALVANIZED STEEL (RGS) EXCEPT THAT: (o) POLYVINYL CHLORIDE RULES, AND ORDINANCES HAVING JURISDICTION. PVC) CONDUITS MAY BE USED IN CONCRETE SLABS AND UNDERGROUND PROVIDED -- - F--� FLUORESCENT STRIP ELBOWS AND RISERS ARE RGS: (b) ELECTRICAL METALLIC TUBING (E.MT) MAY BE - 3. IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR TO PROVIDE ALL USED IN OR ON WALLS OR CEILING MERE NOT SUBJECT TO MECHANICAL DAMAGE, Q DOWN LIGHT CEILING MOUNTED LABOR, MATERIALS, AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK SHOWN DAMP CONDI1IONS OR CORROSIVE CONDITIONS; (c) LIQUID-TIGHT FLEXIBLE - - DOWN LIGHT RECESSED MOUNTED AND/OR NOTED ON THE DRAWINGS. CONDUIT WHERE REQUIRED; (d) FLEXIBLE METALLIC CONDUIT WHERE REQUIRED IN DRY LOCATIONS; (e) THE USE OF AC OR MC CABLES SHALL BE PROHIBITED. 1-O WALL MOUNTED 4. ALL REQUIRED INSURANCE SHALL BE PROVIDED FOR PROTECTION AGAINST PUBLIC ALL CONDUITS IN HAZARDOUS AREAS (PER NEC) SHALL MEET T'HE REQUIREMENTS -`- LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. OF NEC CHAPTER 5. _ - - v v v TRACK WITH TRACK HEADS 5. ELECTRICAL CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY ALL 24. FOR UNDERGROUND ELECTRICAL CONDUITS, PROVIDE PULL BOXES, SUCH THAT NO - - -- - EMERGENCY LIGHT - BATTERY UNIT CONDITIONS, LOCATIONS, DIMENSIONS AND COUNTS AS SHOWN AND/OR NOTED ON THE SINGLE CONDUIT RUN HAS BENDS IN EXCESS OF 360. PULL BOXES SHALL BE - DRAWINGS. THIS SHALL INCLUDE ANY AND ALL FABRICATIONS REQUIRED PRIOR TO SUITABLE AND APPROVED FOR THE INTENDED USE. WHERE CONDUITS PASS UNDERNEATH rQ EXIT SIGN 41H STROBE LIGHT INSTALLATION. PAVED AREAS THEY SHALL BE RGS. WHERE UNDERGROUND CONDUITS ARE NOT - EXPOSED TO MECHANICAL DAMAGE OR ARE NOT UNDER PAVED AREAS, THEY MAY BE _ f-{� POLE MOUNTED SITE LIGHT F!X1LRE CONSULTANT: 6 IT SHALL BE THE RESPONSIBILITY OF THE ELECTRICAL CONTRACTOR FOR THE SCHEDULE 40 PVC, BUT ALL CONDUIT RISERS SHALL BE RGS. RGS CONDUITS SHALL - " - - ADVANCED ORDERING OF LONG LEAD ITEMS SO AS NOT TO INTERFERE WITH THE EXTEND A MINIMUM OF 18" BELOW GRADE. 2' X 4` FLUORESCENT ON EMERGENCY OR NIGHT LITE CIRCUIT - PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME. - --- 25. APPLY BITiJMASTIC COATING 70 ALL METALLIC CONDUITS IN SLABS OR UNDERGROUND. � DOWN LIGHT ON EMERGENCY OR NIGHT LITE CIRCUIT 7. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR A PERIOD OF NOT LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, UNLESS 26. ALL CONDUCTORS SHALL BE COPPER, RATED 75'c WET/DRY EXCEPT WHERE OTHERWISE __- CIOp ENGINEERING, LTI NEE ENGINEERS INC. INDICATED OR SPECIFIED OTHERWISE. REQUIRED BY U.L. OR CODES UNLESS OTHERWISE NOTED, MINIMUM WRE SIZE - - WIRING DEVICES CONSULTING IENGINEIERB SHALL BE #12 AWG EXCLUDING CONTROL WIRING. - - - -- � DUPLEX GROUNDING RECEPTACLE MOUNTED 18" AFF •- 20 AMP. 3901 SW 47th Ave. Suite 44 8. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE ANO �_ - - SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION 27. WIRE WAYS SHALL BE SIZED AS REQUIRED, PER NEC, UNLESS OTHERWISE NOTED. D"a,cFlo No. E800333 0 (3- SINGLE GROUNDING RECEPTACLE MOUNTED 18" AFF - 20 AMP. Davie, Florida 33314 WHICH MAY HAVE BEEN DAMAGED THEREBY. - - - -- -� 28. ALL ELECTRICAL EQUIPMENT SHALL BE RAINTIGHT WHERE EXPOSED TO THE WEATHER. _ � DUPLEX GROUNDING RECEPTACLE MOUNTED ABOVE COUNTER - 20 AMP. Ph 954-791-2020 Fx 583-2345 9. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO ORIGINAL ALL FLEX CONDUITS CONNECTED TO SUCH EQUIPMENT SHALL BE LIQUID-TIGHT. _!-_ _ OED Job 99069 CAD K:\9969.1 CONDITIONS ANY AND ALL DAMAGES TO BUILDING SURFACES, EQUIPMENT AND - - DUPLEX GROUNDING RECEPTACLE WITH ISOLATED GROUND HARE tdOUNTED FURNISHINGS CAUSED DURING PERFORMANCE OF WORK. 29. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH H _ _ _ 18" AFF - 20 AMP. THREADED HUBS IN WET OR DAMP LOCATIONS AND SPECIAL ENCLOSURE FOR OTHER �- ---" - 10. ELECTRICAL CONTRACTOR SHALL NOT SCALE DRAWINGS. CONTRACTOR SHALL REFER TO CLASSIFIED AREAS. PROPER PLASTER RINGS SHALL BE USED VATH OUTLET BOXES. I � DUPLEX GROUNDING RECEPTACLE WTH GROUND FAULT INTERRUPTER MOUNTED ARCHITECTURAL PLANS AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT PROPER COORDINATION BETWEEN ELECTRICAL SUBCONTRACTOR AND GENERAL GFI 18" AFF -20 AMP UNLESS NOTED OTHERWISE. CONTRACTOR FOR PLASTER RING INITIATION WILL BE REQUIRED. NO "GOOF" RINGS SHALL BE ALLOWED, ALL OUTLET BOXES SHALL BE SECURELY FASTENED. DUPLEX GROUNDING RECEPTACLE FLUSH FLOOR MOUNTED - 20 AMP. 11, ALL ELECTRICAL EQUIPMENT, DEVICES, WIRE, ETC., SHALL BE LISTED FOR THE INTENDED USE, WITH UNDERWRITER'S LABORATORIES, INC. (UL) WHERE STANDARDS 30. MOTOR STARTERS SHALL BE MANUAL OR MAGNETIC, AS INDICATED OR REQUIRED, AB B R E VI A TI 0 N S Cd1ADRUPLEX GROUNDING RECEPTACLE MOUNTED 18"AFF - 20 AMP. HAVE BEEN ESTABLISHED BY UL. AS A MINIMUM, ALL EQUIPMENT SHALL MEET WITH OVERLOAD RELAYS OR FUSES IN EACH HOT LEG. � MULTI-OUTLET ASSEMBLY W/RECEPTACLES 6" ON CENTER APPLICABLE STANDARDS FOR THE TYPE OF EQUIPMENT AND INTENDED USE OF THE FOLLOWING: 31. FURNISH AND INSTALL DISCONNECT SWITCHES AND WIRING FOR AR CONDITIONING SPECIAL PURPOSE RECEPTACLE MOUNTED 18" AFF - DATA AS NOTED SYSTEM AS PER MANUFACTURER RECOMMENDATIONS. CONTROLS ARE TO BE SUPPLIED AMP AMPERES I INCANDESCENT A. AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI). BY AIR CONDITIONING CONTRACTOR AND CONNECTED BY ELECTRICAL CONTRACTOR. AFF ABOVE FINISHED FLOOR ISC INSTANTANEOUS SHORT CIRCUIT SINGLE POLE SNATCH MOUNTED 48" AFF - 20 AMP. PROVIDE ALL CONTROL WIRING FOR A/C SENSORING AND CONTROL UNITS, COORDINATE AG ABOVE GRADE ID IDENTIFICATION B. ILLUMINATING ENGINEERS SOCIETY (IES). WITH A/C CONTRACTOR FOR WIRING DIAGRAMS AND EXACT MOUNTING LOCATIONS, ATS AUTOMATIC TRANSFER SWITCH 33 THREE WAY SNATCH MOUNTED 48" AFF - 20 AMP, C. AMERICAN SOCIETY FOR TESTING AND MATERIALS (ASTM). 32. ALL DISCONNECT SWITCHES SHALL BE SIZED BY NEC TO ACCOMMODATE EQUIPMENT AM AMERICAN WIRE GAUGE J8 JUNCTION BOX `} SERVED, INCLUDING REQUIRED FUSES, U.O.N., DISCONNECT SWITCHES SHALL BE HORSEPOWER AC ALTERNATING CURRENT KW KILOWATT 4 4 FOUR WAY SWITCH MOUNTED 48" AFF - 20 AMP. D. NATIONAL ELECTRICAL MANUFACTURER'S ASSOCIATION (NEMA). RATED, HEAVY-DUTY TYPE. AHU AIR HANDLING UNIT KVA KILO `JOLT-AMPERE ID DIMMER SNATCH, 2000 WATT, MOUNTED 48" AFF A/S ANTI-SWEAT NOTE; 33. ALL FUSES SHALL BE CURRENT LIMITING, PER U.L., RATED 600 VOLTS, AIC AMP INTERRUPTING CAPACITY LIPS LOW PRESSURE SODIUM IF FAN SPEED CONTROL SNATCH MOUNTED 48" AFF THESE STANDARDS ARE SUBORDINATE TO CODES AND STANDARDS SET BY UL. UNLESS OTHERWISE NOTED. LT LIGHT �Qyy A. NON TIME DELAY FUSES IN MAIN SNATCHES AND SWITCHES FEEDING PANELS. BLDG BUILDING $K KEY OPERATED SNATCH MOUNTED 48" AFF - 20 AMP. � 'A 12. IT SHALL NOT BE THE INTENT OF THESE PLANS AND/OR SPECIFICATIONS TO SHOW BSS BUILDING STRUCTURAL STEEL MFG MANUFAC nJRER HORSEPOWER RATED MANUAL STARTER SNATCH MTD AT EQUIPMENT �'•/ (�, EVERY MINOR DETAIL OF CONSTRUCTION, THE ELECTRICAL CONTRACTOR SHALL BE B. TIME DELAY FUSES FOR MOTOR AND A/C CIRCUITS. MTG MOUNTING M z LL EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL C CONDUIT MTD MOUNTED SINGLE POLE SWITCH WITH PILOT LT MOUNTED 48' AFF - 20 AMP. .4r SYSTEM AND PROVIDE ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED 34. ELECTRICAL CONTRACTOR SHALL VERIFY CIRCUIT PROTECTIVE DEVICE RATING FOR CCT CIRCUIT MT MOUNT P IN PROPER WORKING ORDER. EQUIPMENT PRIOR TO CONSTRUCTION. CT CURRENT TRANSFORMER MV MERCURY VAPOR TELEPHONE OUTLET BOX MOUNTED 18" AFF CU COPPER MH METAL HALIDE 1C0 13. ALL CONDUIT RUNS ARE SHOWN DIAGRAMMATICALLY. EXACT ROUTING SHALL BE DETERMINED 35. ALL CIRCUIT BREAKERS SHALL BE BOLT-IN, INVERSE TIME-TYPE (THERMAL-MAGNETIC). CB CIRCUIT BREAKER w® TELEPHONE OUTLET BOX MOUNTED 54" AFF IN THE FIELD, UNLESS OTHERWISE NOTED. THE ELECTRICAL CONTRACTOR SHALL PROVIDE TWO AND THREE-POLE CIRCUIT BREAKERS SHALL HAVE COMMON TRIP. NO TIE HANDLES CLG CEILING .> AND INSTALL THE PROPER NUMBER OF CONDUCTORS IN ALL RACEWAYS AS REQUIRED TO SHALL BE PERMITTED. ALL PA.NELBOARDS SHALL HAVE COPPER BUS. CW COOL WHITE NIC NOT IN CONTRACT ® TELEPHONE OUTLET FLUSH FLOOR MOUNTED L LL. ACCOMPLISH THE PROPER FUNCTIONING OF THE DEVICE OR EQUIPMENT AS SHOWN. CWP COLD WATER PIPE NC NORMALLY CLOSED " 36. WHERE CORE DRILLING OF FLOOR/WALLS IS REQUIRED, CONTRACTOR SHALL SEAL NO NORMALLY OPEN B•ACEWAYS 2 A. THE ELECTRICAL CONTRACTOR SHALL PROVIDE & INSTALL 4-3/4 E.C. FROM ALL OPENINGS WATERTIGHT AFTER UTILITIES HAVE BEEN INSTALLED. LOCATION OF FLUSH MOUNTED PANELBOARDS TERMINATING 6" ABOVE CEILING. CORED HOLES SHALL BE COORDINATED WITH LOCATION OF EQUIPMENT IN A MANNER DC DIRECT CURRENT P PENDANT --- CONCEALED CONDUIT '" W TO BE CLEAN AND FUNCTIONAL. THE CONTRACTOR SHALL INSTALL ONLY ONE PA PUBLIC ADDRESS - - - - - UNDERGROUND CONDUIT cc 14. THE ELECTRICAL CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING PER- CONDUIT PER HOLE AND SEAL THE OPENING AROUND THE CONDUIT AS SPECIFIED. E EXISTING PEC PHOTOELECTRIC CELL FORMED, FREE FROM DEBRIS AT ALL TIMES AND SAID AREAS SHALL BE LEFT BROOM EC EMPTY CONDUIT CLEAN AT THE END OF EACH WORKING DAY. 37, PROVIDE FIRE RETARDANT U.L. APPROVED SEALANT ON ALL PENETRATIONS OF FIRE EM EMERGENCY PF POWER FACTOR - T CAPPED CONDUIT RATED PARTITIONS, WALLS AND STRUCTURAL SLABS. IT SHALL BE THE RESPON- ER EXISTING TO BE REMOVED PNL PANEL /��'�/W FLEXIBLE METALLIC CONDUIT LL ® CO C) 15. CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, AND TESTING. SIBILITY OF THE ELECTRICAL CONTRACTOR TO VERIFY, PRIOR TO SUBMITTING BID, ETR EXISTING TO REMAIN 16. ARCHITECTURAL AND/OR ENGINEERING EXPENSES THAT ARE INCURRED DUE TO LOCATIONS OF ALL SUCH FIRE RATED PARTITIONS, WALLS, AND STRUCTURAL SLABS. EWC ELECTRIC WATER COOLER R RECESSED J_ AC SYSTEM GROUND % ♦!� REVISIONS OR SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR EM ELECTRIC WATER HEATER REP REPRESENTATIVE \oJ �,/ BY THAT CONTRACTOR. 38. ALL OPENINGS FOR LIGHT FIXTURES IN CEILING SHALL BE PROTECTED IN A MANNER Ep EXPLOSION PROOF RGS RIGID GALV. STEEL CEILING MOUNTED JUNCTION BOX �,� (PER ALL GOVERNING CODES) THAT WILL PROVIDE THE SAME RATING AS THE CEIL- EX. EXISTING RS RAPID START � T ALL FIRE RATED CEILINGS).17. ELECTRICAL CONTRACTOR SHALL SUBMIT (6) COPIES OF EQUIPMENT LAYOUT FOR ALL ING. (THIS APPLIES 0 L ) I-0J WALL MOUNTED JUNCTION BOX ELECTRICAL SPACES, ROOMS, ETC. TO ENGINEER FOR APPROVAL PRIOR TO ORDERING EQUIPMENT OR INSTALLING CONDUITS, ETC. LAYOUT SHALL CONSIST OF PLAN VIEWS 39• ALL BALLASTS SHALL HAVE MIN. POWER FACTOR OF 0.90. ALL BALLASTS FOR F FLUORESCENT s SURFACE � JQ FLUSH FLOOR MOUNTED JUNCTION BOX � ( SCALED AT IN A 1'-0" ) AND ELEVATIONS (DIMENSIONED)HALL C FOR EACH SUCH MERCURY VAPOR, METAL HALIDE AND HIGH PRESSURE SODIUM FIXTURES SHALL BE FA FIRE ALARM Sc SHORT CIRCUIT VJ SPACE, ROOM, ETC. CONSTANT WATTAGE TYPE WITH 53 LAMP WATTS FOR 10% NOMINAL LINE VOLTAGE FA VARIATION. FC FOOT CANDLE POW R .DI.5TRI UT1 EQUIPMENT W � 18. ELECTRICAL CONTRACTOR SHALL SUBMIT AT ONE TIME, SIX (6) SETS LOOSE-LEAF TV TELEVISION SAFETY SIMTCH;3___ _=POLES, 30�SNATCH RATING,___=FUSE 51ZE,PER cc BOUND AND INDEXED OF ALL PRODUCTS, MATERIALS, LIGHTING FIXTURES, LAMPS, 40, PROVIDE LAMPS WITH FIXTURES, SEE LUMINAIRE SCHEDULE FOR LAMP TYPE. FPL FLORIDA POWER & LIGHT ❑J WIRING DEVICES, SWTCHGEAR, ETC. ALL EQUIPMENT SHALL BE AS SPECIFIED ON FT FOOT UG UNDERGROUND _ PLANS: THE RESPONSIBLITY TO ACCEPT OR REJECT ANY PROPOSED SUBSTITUTION 41. ALL CONNECTIONS TO GROUND ROOS & BUILDING STEEL SHALL BE MADE WITH UL UL UNDERW'Rl TERS LABORATORIES *- FUSE SIZE OR MANUFACTURERS NAMEPLATE LABEL REMAINS WITH THE PROJECT ENGINEER. THE CONTRACTOR MAY AT HIS JUDGMENT APPROVED WELDED CONNECTIONS, UNLESS OTHERWISE NOTED: GALV GALVANIZE USE ANY ARTICLE, DEVICE, PRODUCT, OR MATERIAL GFl GROUND FAULT INTERRUPTER LION UNLESS OTHERWISE NOTED � CONTACTOR OR MOTOR STARTER WHICH IN THE JUDGMENT OF THE ENGINEER EXPRESSED IN WRITING ARE EQUAL TO THAT SPECIFIED. 42, PROVIDE MOUNTING BACKBOARDS FOR ELECTRICAL AND COMMUNICATION EQUIPMENT. GND GROUND BACKBOARDS SHALL BE OF TYPE "AC" PLYWOOD, PAINTED ON BOTH SIDES VA VOLT AMPERES BRANCH CIRCUIT P,�tiELBOARD 19. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, WIRING, DEVICES, ETC., SHALL BE AND EDGES WITH TWO COATS OF LIGHT GREY PAINT. NEW. W WATT [] DRY TYPE STEP-DOWN TRANSFORMER 43. PROVIDE A FUSE HOLDER AND FUSE IN THE PRIMARY SIDE OF EACH UNGROUNDED HID HIGH INTENSITY DISCHARGE wiry WARM WHITE r 20. COORDINATE ALL ELECTRICAL SITE WORK WITH GENERAL CONTRACTOR PRIOR TO CONDUCTOR FOR EACH BALLAST (BUSSMAN HEB AND FNQ OR EQUAL), AT THE HAND HPS HIGH PRESSURE SODIUM WP WEATHERPROOF ( J TIME CLOCK INSTALLATION. HOLE OF EACH EXTERIOR POLE MOUNTED LIGHTING FIXTURE OR J-BOX FOR WALL OR HO HIGH OUTPUT FIRE ALARM DEVICES 21. FOR ELECTRIC POOR SYSTEM. GROUND MOUNTED FIXTURE. s{fl W34 COMBINATION HORN AND STROBE LIGHT MOUNTED 80" AFF W/75 CANDELLAS A- COORDINATE POWER SERVICE NTH POWER COMPANY. 44, PROVIDE TEMPORARY ELECTRICAL SERVICE FOR USE BY ALL TRADES DURING CON- B. VERIFY LOCATION OF POWER SERVICE TERMINATION NTH POWER COMPANY STRUC11ON AND REMOVE SAME AT COMPLETION OF PROJECT, � STROBE LIGHT MOUNTED � 80" AFF. WI PRIOR TO SUBMITTING BID. 22. FOR TELEPHONE SYSTEM: 45. THE ELECTRICAL CONTRACTOR SHALL FURNISH A COMPLETE SEf OF AS-BUILT F[] PULL STATION MOUNTED 48" AFF DRAWINGS, SHOVING ALL CHANGES AND DEVIATIONS TO THE ARCHITECT/ENGINEER FLOW SWITCH A. PROVIDE GROUNDING FOR ALL TELEPHONE OUTLETS AND EQUIPMENT PER PRIOR TO COMPLETION OF THE PROJECT. REQUIREMENTS OF TELEPHONE COMPANY. B. COORDINATE INSTALLATION OF ALL TELEPHONE OUTLETS, RACEWAYS, ENCLOSURES, 48, PREPARE AND AFFIX A TYPEWRITTEN DIRECTORY TO THE INSIDE COVER OF EACH TAMPER SWITCH AND BACKBOARDS WITH TELEPHONE COMPANY. NEW AND OR EXISTING (REVISED) PANELBOARD )NDICATING LOADS CONTROLLED BY [S)4 S'PEAKER WITH STROBE LIGHT W/75 CANDELLAS C. TELEPHONE CONDUITS SHALL NOT BE INSTALLED IN THE SAME TRENCH NTH POWER EACH CIRCUIT. AF AND LIGHTING CONDUITS. GENERAL CONDITIONS: SCHARF FIREMAN'S JACK 1. THE NATURE OF THIS CONTRACT INVOLVES EXTENSIVE REMODELING OF EXISTING FACILITIES. THE ELECTRICAL CONTROL PANEL [[AAr-00014V ASSOCIATES CONTRACTOR, PRIOR TO BID, SHALL INSPECT THE EXISTING CONDITIONS AT THE JOB SITE AND ACQUAINT HIMSELF NTH CORPORATED WITH THE CONDITIONS THAT WILL AFFECT HIS WORK. © REMOTE ANNUNCIATOR PANEL CHITBC s PI.Anr(B� 2. PRIOR TO ROUGH-IN, THIS CONTRACTOR SHALL COORDINATE HIS WORK WITH THE ACTUAL EQUIPMENT BEING FURNISHED. ® St4OKE DETECTOR 7 It t 9th Avenua c: 3. PRESENT ELECTRICAL EQUIPMENT WHERE INDICATED ON THE DRAWINGS OR WHERE THE INSTALLATIONS WILL INTERFERE HEAT DETECTOR It WITH THE INSTALLATION OF NEW EQUIPMENT OR NEW ARCHITECTURAL CHANGES, SHALL BE REMOVED, RELOCATED, OR I�tuderdnle.lr�orids U RE-ROUTED TO PERMIT COMPLETETION OF SUCH WORK. �-+ DUCT DECTECTOR 4. SALVAGED MATERIALS, EQUIPMENT, AND LIGHT FIXTURES SHALL BE DELIVERED TO THE OWNER AT HIS PROPERTY AND MISCELLANEOUS STORED WITHIN THE BUILDING WHERE DIRECTED. ANY REMOVED MATERIALS OR EQUIPMENT WHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED OF BY THE CONTRACTOR, WITHOUT ADDITIONAL COST TO THE OWNER. -IS P:A. SYSTEM SPEAKER MOUNTED AS NOTED 5. ALL PRESENT CONDUIT IN EXISTING AREAS TO BE ALTERED, WHICH WILL HAVE NO USE UPON COMPLETION OF THE © SPEAKER - CEILING MOUNTED DRAWING TITLE:: ALTERATIONS SHALL BE REMOVED. WHENEVER CONDUITS ARE OR WILL BECOME EXPOSED TO VIEW, OR WILL INTERFERE a DOOR BUZZER CALL BUTTON MOUNTED 48" AFF WITH THE INSTALLATION AND COMPLETION OF THE WORK REQUIRED,THEY SHALL ALSO BE REMOVED. NOTES t 6. THE ELECTRICAL CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH EXISTING CONDUIT AND THE WIRING WILL HAVE B CALL BUZZER MOUNTED 90" AFF LEGENpg TO BE RE-ROUTED, RELOCATED, OR RECONNECTED, AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED COMPUTER OUTLET MOUNTED 18" AFF DUE TO THE PHYSICAL CONDITIONS OF THE CONDUIT AND WIRING SHALL BE PERFORMED UNDER THIS CONTRACT WITHOUT TELEVISION OUTLET MOUNTED 18' AFT= DRAWN: LEE ADDITIONAL CHARGES TO THE OWNER. 7. CONDUIT SHALL NOT BE RUN EXPOSED THROUGH EXISTING OR NEW FINISHED SPACE UNLESS WRITTEN PERMISSION IS QT THERMOSTAT MOUNTED 60" AFF CHECKED: / ' GRANTED BY THE OWNER. MOTOR DATE: 02/18100 8. INTERRUPTION OF EXISTING FACILITIES OR SERVICES SHALL BE KEPT TO A MINIMUM AND THE CONTRACTOR SHALL CLOCK MOUNTED 80" AFF FURNISH ALL MATERIALS AND LABOR REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN SCALE: AS NOTED CONTINUITY OF SERVICE. INTERRUPTION OF SERVICES, THE INSTALLATION OF TEMPORARY FACILITIES, AND THE WORK ® CONTROL CENTER PROJECT NO.: 21391 OF MAKING FINAL CONNECTIONS TO NEW WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERMITTED AND SCHEDULED ] PROGRAM BELL MOUNTED 90" AFF BY THE OWNER WITHOUT ADDITIONAL COST. THE ELECTRICAL CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE SHE SERVICE INTERRUPTIONS WITH THE OWNER AND GENERAL CONTRACTOR. [3. CCTV SECURITY CAMERA (HEIGHTS VARY) , NOTE: THESE ARE STANDARD SYMBOLS AND ALL MAY NOT APPEAR ON PRO WHEREVER THE SYMBOL ON THE PROJECT OCCURS. THE ITEM SHALL BE PR VIOD �4 E 5 0 .fiQ } of: