00-0246-007 NO, REVISIONS DATE AIR CONDITIONING GENERAL NOTES AIR CONDITIONING UNIT SCHEDULE AIR CONDITIONING SYMBOL LEGEND BID/PERMIT 02/18/ STRIP HEATER '� OWNER'S REV.03/14/ A. GENERAL SELECTION BASED ON :TRANE SPLIT SYSTEM CAPACITIES (MBH) INDOOR FAN DATA FAN MOTOR DATA CONDENSER FILTER 1, AIR CONDITIONING CONTRACTOR SHALL VISIT THE JOB SITE PRIOR TO BID AND VERIFY ALL CONDITIONS, LOCATIONS, DIMENSIONS, EER/ MBH CFM EXT, S,P VOLTS VOLTS FUSE VOLTS FUSE TYPE 2 OWNER'S REV.04/18/00 MATERIALS, ELEVATIONS AND COUNTS AS SHOWN AND/OR NOTED ON THE DRAWINGS AND INCLUDE IN THE BID ANY AND ALL DESIG. MODEL NUMBER SEER MFG. SENSIBLE TOTAL SUPPLY O,A, IN. W.G. H P, RPM. PHASE K.W. STEP PHASE (AMPS) MCA DESIG, MODEL NUMBER PHASE (AMPS) MCA REMARKS SYMBOL DEFINITION ABBREVIATION FABRICATION REQUIRED PRIOR TO INSTALLATION. THE CONTRACTOR SHALL VERIFY SIZE, ELEVATION, AND PRESENT STATE OF ALL Q3 BLDG, DEPT, 06/20/ EXISTING UTILITIES, FC-1 'kSP18 10 EMI 12540 18000 550 - 208/1 - - - - - CU-1 208/1 15 O1 � - - - �, EXISTING DUCTWORK (SINGLE LINE) 2, THE ENGINEER SHALL BE IMMEDIATELY NOTIFIED OF ANY AND ALL EXISTING FIELD CONDITIONS WHICH DEVIATE FROM WHAT WAS - EXISTING DUCTWORK (DOUBLE LINE) SHOWN ON THE PLANS. CONTRACTOR IS RESPONSIBLE TO PROVIDE PRICING FOR A COMPLETE INSTALLATION INCLUDING ANY COSTS ASSOCIATED WITH FIELD CONDITIONS AT THE TIME OF BIDDING. - - 3. IT SHALL BE THE RESPONSIBILITY OF THE AIR CONDITIONING CONTRACTOR FOR THE ADVANCED ORDERING OF LONG LEAD ITEMS SO PROVIDE CONDENSATE PUMP. S-SPLIT yE >E -f, EXISTING DUCTWORK TO BE REMOVED (SINGLE LINE) THAT DELIVERY WILL NOT INTERFERE WITH THE PRODUCTION OF OTHER TRADES RESULTING IN ANY DOWN OR LAG TIME, EXISTING DUCTWORK TO BE REMOVED 4. IT SHALL BE THE RESPONSIBILITY OF THE AIR CONDITIONING CONTRACTOR TO PROVIDE ALL LABOR, MATERIALS, AND SUPERVISION NECESSARY TO ACCOMPLISH THE WORK SHOWN AND/OR NOTED ON THE DRAWINGS. THE DRAWINGS ARE DIAGRAMMATIC: DO NOT SCALE EXHAUST FAN SCHEDULE FOR EXACT LOCATIONS, THE AIR CONDITIONING CONTRACTOR SHALL INSTALL ALL NECESSARY OFFSETS, BENDS, AND TRANSITIONS AS FAN H,P. WALL ROOF SPECIAL N x N NEW DUCTWORK (1St N = SIZE OF SIDE SHOWN) REQUIRED TO PROVIDE A COMPLETE AND FULLY OPERATIVE SYSTEM, ALL DUCT SIZES ARE CLEAR INSIDE DIMENSIONS, CONTRACTOR DESIG, LOCATION MANUFACTURER MODEL No, CFM E.S,P, RPM (WATTS) VOLT/PH. DRIVE OPENING FEATURES REMARKS SHALL NOTIFY ENGINEER IF DUCT SIZE CHANGES ARE REQUIRED BECAUSE OF EXISTING CONDITIONS, 5, CONTRACTOR SHALL PAY FOR ALL PERMITS, FEES, INSPECTIONS, TESTS, AND ALL REQUIRED INSURANCE FOR PROTECTION AGAINST EF-1 RESTROOM PENN Z1 50 CFM .125 1700 (55) 120/1 D (D W� FLEXIBLE DUCT rDavie, LTANT; PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK, EF-2 RESTROOM PENN Z1 50 CFM _125 1700 (55) 120/1 D � �� FIRE DAMPER FD 6. AFTER BID SELECTION AND PRIOR TO COMMENCEMENT OF WORK, THE AIR CONDITIONING CONTRACTOR SHALL SUBMIT (6 COPIES) OF Aff EQUIPMENT CUTS FOR ALL DUCT WORK, EXHAUST FANS, AIR DEVICES, AND EQUIPMENT AS STATED ON SCHEDULES AND OR NOTES. IF THE CONTRACTOR PROPOSES TO USE ANY ARTICLE, DEVICE, PRODUCT, OR MATERIAL WHICH IS NOT AS SPECIFIED, THE CONTRACTOR SMOKE DAMPER SD GINEERING, INC. SHALL BE RESPONSIBLE TO PROVE TO THE ENGINEER THAT THE PROPOSED SUBSTITUTION IS EQUAL AND WILL FIT ALLOCATED SPACE. TING ENGINEERS B. WORKMANSHIP 01 2 BACKDRAFT DAMPER EFSCH FIRE AND SMOKE DAMPER FSD 47th Ave. Suite 402 7, ALL WORK SHALL BE PERFORMED BY A LICENSED AIR CONDITIONING CONTRACTOR IN A FIRST CLASS WORKMANLIKE MANNER, ALL WORK- No. E60005720 MANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPLICABLE NATIONAL, STATE AND LOCAL CODES AND ORDINANCES. O #12 SWG GALVANIZED STEEL WIRE HANGERS (4 REQUIRED). O SUPPORT CHANNEL (2 REQUIRED). VOLUME DAMPER VD rido 33314 ATTACH WIRE HANGERS TO STRUCTURE. 1-2020 Fx 583-2345 8 THE AIR CONDITIONING CONTRACTOR SHALL BE RESPONSIBLE TO REPAIR TO ORIGINAL CONDITION ANY AND ALL DAMAGES TO BUILDING DIFFUSER & GRILL SCHEDULE CEILING: ACOUSTICAL PANEL (LAY-IN), OPPOSED BLADE DAMPER OBD 069.2 CAD K:\9969.2 SURFACES, EQUIPMENT, AND FURNISHINGS CAUSED BY THE CONTRACTOR DURING THE PERFORMANCE OF WORK. O VERTICAL METAL DUCT, ACOUSTICAL TILE OR GYPSUM WALLBOARD DESIG. MANUFACTURER MODEL No, REMARKS 9. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION WHICH MAY HAVE BEEN DAMAGED THEREBY. S LISTED FUSIBLE LINK OR ALT. LISTED ADJ_24x24 PERFORATED LAY-IN O O MOUNTING BOLTS, SCREWS OR RIVETS, ELECTRIC DUCT HEATER EDH NAILOR 4320A-L-24 DIFFUSER SEE PLANS FOR NECK SIZES FUSIBLE LINK ASSEMBLY (BLADE CONTROL C. PIPING \-?-/ AILOR 432OA-L-12-0612x12 PERFORATED LAY-IN THROUGH SCREW ADJUSTMENT). DUCT DROP W/ BOTTOM FLAT 10. ALL REFRIGERANT PIPING SHALL BE TYPE "L" OR TYPE "K" COPPER WITH WROUGHT COPPER OR BRASS FITTINGS. DIFFUSER 1-WAY W OBD ® FIRE CAULK TO SEAL DUCT OPENING, 24x24 PERFORATED SURFACE 4320A-S-24 ® STEEL DUCT DROP f DUCT RISE W/ TOP FLAT STEEL VALVES ARE NOT PERMITTED. NAILOR 3 MOUNT DIFFUSER W . 11. THE AIR CONDITIONING CONTRACTOR SHALL RUN ALL CONDENSATE GRAINS IN COPPER UNLESS OTHERWISE NOTED. CONDENSATE DRAINS � NAILOR 51 PR 24x24 PERFORATED RETURN GRILLE O SHALL BE RUN ACCORDING TO PLUMBING DRAWINGS 12. INTERIOR CONDENSATE DRAIN PIPING AND REFRIGERANT SUCTION LINES SHALL BE INSULATED WITH 5/8" THICK IMCOLOCK OR ARMAFLEX. VANED ELBOW - PROVIDE ALL SQUARE OR® RECTANGULAR ELBOWS WITH TURNING VANES. 13. COMBUSTIBLE PIPING IS NOT PERMITTED IN RETURN AIR PLENUMS OR CEILING SPACES USED FOR RETURN AIR. D. INSTALLATION O ® � y CEILING DIFFUSER CD 14. LOCATION OF AIR CONDITIONING DUCTS AND AIR DEVICES MAY CHANGE, VERIFY EXACT LOCATION WITH ARCHITECT/ENGINEER PRIOR FIr TO INSTALLATION. DRAWINGS ARE DIAGRAMMATIC, DO NOT SCALE FOR THE EXACT LOCATION OF DUCTS, DIFFUSERS, GRILLES, S-DIFIJSR � r 2 RETURN REGISTER OR GRILLE RG REGISTERS, PIPING, EQUIPMENT, ETC. SEE ARCHITECTURAL REFLECTED CEILING PLAN FOR EXACT LOCATION OF AIR DEVICES, IL J 15. THE AIR CONDITIONING CONTRACTOR SHALL MOUNT ALL ROOFTOP EQUIPMENT ON FACTORY FABRICATED CURBS AND ANCHORS 0 0 FOR A MINIMUM OF 125 MPH WIND LOADS. WIND LOADS AT MOUNTING HEIGHTS SHALL BE AS REQUIRED BY LOCAL CODES. FACE OF CEILING e ® �y EXHAUST REGISTER OR GRILLE EG = Ln 16. THE AIR CONDITIONING CONTRACTOR SHALL USE VANED ELBOWS OR APPROVED 3 PIECE ELBOWS, SPUTTER DAMPERS WHERE 3 V INDICATED, VOLUME CONTROLS IN ALL BRANCH LINES AND SUPPLY AND RETURN AIR DEVICES, TO FACE OF BLADED - - - - - - - SIDEWALL REGISTER SW 7 LL Q 17. THE AIR CONDITIONING CONTRACTOR SHALL SEAL ALL DUCTS IN AN APPROVED MANNER TO INSURE AGAINST LEAKAGE. _ _4_0 � LINEAR DIFFUSER LD � 18. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID ANY CONFLICTS IN LOCATIONS FOR DUCTS, DIFFUSERS, NEW ROOFTOP PACKAGE W GRILLES, REGISTERS, PIPING, EQUIPMENT, ETC,. INORDER TO NOT INTERFERE WITH THE PROGRESS OF CONSTRUCTION, UNIT (RTU-1) ' MAX. � � �- DOOR GRILLE DG � n > E. EQUIPMENT AND MATERIALS iAj POSITIVE PRESSURE DUCT W 0 cc 22GA METAL STRAP HUNG CEILING \- CEILING UP DN Z 19. THE AIR CONDITIONING CONTRACTOR SHALL PROVIDE FLEXIBLE DUCT CONNECTIONS TO ALL FANS, A/C UNITS, OR MECHANICAL W/ TWO 3/16x3/4 SELF TAPPING SCREWS 3/4 CONDENSATE TEE Q EQUIPMENT, EXCEPT FOR EXHAUST HOODS. THREE EACH SIDE DRAIN TO EXISTING R/A Up� 20. ALL EXHAUST AND OUTSIDE AIR DUCTS SHALL BE GALVANIZED SHEET METAL CONSTRUCTED Ar:D INSTALLED IN ACCORDANCE TH ROOF DRAIN GRILLE ® UP © DN NEGATIVE PRESSURE RETURN DUCT Q ASHRAE, SMACNA, AND LOCAL CODES. ALL OUTSIDE AIR DUCTS SHALL HAVE i" INSULATION IN AIR CONDITIONED SPACES. V/ 16 GA ROOF CURB A- 7_7L /16x3/4 ;� up © oN NEGATIVE PRESSURE EXHAUST DUCT � � � e� 21. UNLESS NOTED AS EXISTING, ALL EQUIPMENT, PIPING, DUCTS, REGISTERS, ETC.. SHALL BE NEW. ADAPTER ELF TAPPING z 22. TERMINAL AIR DISTRIBUTION DEVICES SHALL BE TITUS, METALARE OR NAILOR-HART OR EQUAL AS SCHEDULED: CREWS 4 EACH SIDE -�D DUCT DETECTOR DD L�� (/) O ALL VOLUME DAMPERS SHALL BE OPPOSED BLADE TYPE WITH SCREWDRIVER ADJUSTMENT. EXISTING 16 GA _ _ _ _ _ __ _ _ _ Z� r r ROOF CURB ° ° ° RETURN AIR DUCT AC AHU AIR CONDITIONER/AIR HANDLING UNIT AC or AHU 0 Z 00 23. ALL SUPPLY AND RETURN AIR DUCTWORK SHALL BE OWENS CORNING FIBERGLASS (lW THICK). TYPE 475 OR 800 OR SHEET A3 VARIABLE AIR VOLUME UNIT VAV ~4 LO -6 EXTERIOR FOILBACK INSULATION. FLEXIBLE DUCTS SHALL BE UL-181 RATED, INSULATED WITH 1 3/4 B. DENSITY e G - e METAL WITH MINIMUM R r"*� R A D I A T I O N DAMPER I N S T A L L A T I O N FIBERGLASS AND SHALL HAVE A METALIZED INNER AND OUTER SCRIM FOIL LINER. OUTER SCRIM FOIL COVERING SHALL HAVE 0 REINFORCED HANGING LOCATIONS, ALL DUCTS SHALL BE SUPPORTED IN AS STRAIGHT AND LEVEL AS FASHION AS POSSIBLE. E ENTIRE A A - -* -S EXISTING PIPING TO BE REMOVED INSTALLATION SHALL BE INSTALLED IN ACCORDANCE WITH ASHRAE, SMACNA, AND LOCAL CODES. I\/I NO SCALE AF-RAD8 Z V� -CD CONDENSATE PIPE CD 24. THE AIR CONDITIONING CONTRACTOR SHALL PROVIDE ALL CONTACTORS, RELAYS, AND THERMOSTATS. THE ELECTRICAL CONTRAC - Uj SHALL PROVIDE ALL SWITCHES, DISCONNECTS, POWER WIRING AND CONTROL WIRING. -CHWS- CHILLED WATER SUPPLY CHWS 25. THE AIR CONDITIONING CONTRACTOR SHALL PROVIDE 1" THICK FARR 30/30 (THROW-AWAY TYPE) FILTERS WITH EACH A/C UNIT, -CHWR- CHILLED WATER RETURN CHWR 26, ALL MATERIALS AND EQUIPMENT SHALL BE NEW AND SHALL BEAR UNDERWRITERS LABEL WHERE APPLICABLE. NEW ROOF TOP UNIT ( RTU - 1 ) CWS CONDENSER WATER SUPPLY CWS F, SAFETY 27. ALL PENETRATIONS OF FIRE-RATED WALLS, FLOORS OR CEILINGS SHALL BE FIREPROOFED BY A SEALING METHOD AND RATING AS ON EXISTING CURB DETAIL CWR- CONDENSER WATER RETURN CWR SPECIFIED ON THE DRAWINGS OR AS REQUIRED BY THE LOCAL OR STATE CODES. (� / �- --D14-- GATE VALVE GV 28. AIR HANDLING DEVICES IN EXCESS OF 2000 CFM WILL HAVE A DUCT SMOKE DETECTOR TO STOP THE FAN AND ACTIVATE A HORN A D /� - \\\\ NAILER STROBE LIGHT, ALL EQUIPMENT SHALL BE INTERLOCKED AS REQUIRED BY LOCAL CODES OR FIRE SAFETY OFFICIALS, I V I COUNTER FLASHING - BUTTERFLY VALVE 29. ALL WORK SHALL COMPLY WITH BASE BUILDING LIFE SAFETY/SMOKE CONTROL SYSTEM REQUIREMENTS, PROVIDE ALL NECESSARY h z i- CHECK VALVE CV WIRING, CONTACTORS, RELAYS, ETC., AS REQUIRED FOR INTERFACE WITH BASE BUILDING SYSTEM. III 30. THE AIR CONDITIONING CONTRACTOR SHALL KEEP ALL AREAS IN WHICH WORK IS BEING PERFORMED, FREE FROM DEBRIS AT ALL TIMES RIGID INSULATION_ BALL VALVE AND SAID AREAS SHALL BE LEFT BROOM GLEAN AT THE END OF EACH WORKING DAY. MAIN DUCT INSTALL PER MFG CANT STRIP 3/4- GATE VALVE WITH HOSE END ADAPTER G. COMPLETION RECOMMENDATIONS HANG PER SMACNA RECQMMENDA ONS gp# ROOFING FELT 31. THE AIRCONDITIONING CONTRACTOR SHALL PROVIDE A COMPLETE SET OF AS BUILT DRAWINGS TO THE ENGINEER UPON COMPLETION OF BALANCING VALVE LOW PRESSURE COLLAR INSTALLATION, IF FIELD CHANGES ARE MADE WHICH DEVIATE FROM ENGINEERING DRAWINGS TO THE EXTENT THAT THE BUILDING 45' TAKE OFF ) I DEPARTMENT REQUIRES THESE CHANGES BE INCORPORATED PRIOR TO INSPECTION, THE CONTRACTOR SHALL PROVIDE SKETCHES TO THE 3 LAYERS ROOFING MATERIAL ENGINEER FOR INCORPORATION INTO THE BUILDING PLANS, ENGINEERING EXPENSES THAT ARE INCURRED DUE TO REVISIONS OR (� ��- AUTOMATIC CONTROL VALVE SCHARF r[AA-CM427 SUBSTITUTIONS REQUESTED BY THE CONTRACTOR SHALL BE PAID FOR BY THAT CONTRACTOR. c 32, THE AIR CONDITIONING CONTRACTOR SHALL TEST AND BALANCE TO THE AIR QUANTITIES ON THE PLAN. PROVIDE T & B REPORT IN STRAINER WITH BLOW DOWN OCIATES ACCORDANCE WITH AIR BALANCE COUNCIL STANDARDS, SIGNED AND SEALED BY A REGISTERED FLORIDA ENGINEER. MAXIMUM DEVIATION SHALL BE PLUS OR MINUS 59a IF INDEPENDENT TEST AND BALANCE IS NOTED AS AN EXCEPTION TO THE CONTRACT NYLON TIEWRAP IN RPORATED DOCUMENTS, THE CONTRACTOR WILL PROVIDE TEMPERATURE DEVIATIONS OF LESS THAN i DEGREE F FROM THE THERMOSTAT SETTING AT COLLAR GROOVE FS CTS 9 PLANNERS ANY LOCATION IN THE SPACE, IF THE OWNER EXPERIENCES UNCOMFORTABLE CONDITIONS, THE CONTRACTOR SHALL BE RESPONSIBLE SEAL FLEX SKIN a -�I�- UNION 9th Avenue FOR THE COST OF VERIFICATION BY A REGISTERED PROFESSIONAL ENGINEER OF AIR FLOW TO WITHIN PLUS OR MINUS 109: WITH MASTIC AND APE D a FM FROM AIR QUANTITIES STATED ON THE PLAN. Q a Q Q FLOW MEASURING STATION Lauderdale,rlorida 33309 33. AIR CONDITIONING CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP TO BE FREE FROM DEFECTS FOR A PERIOD OF Q BV 2700 NOT LESS THAN (1) YEAR FROM DATE OF ACCEPTANCE, AND ALL GUARANTEES AND WARRANTIES SHALL BE DELIVERED TO THE OWNER. 27 COMPRESSORS SHALL HAVE EXTENDED FIVE YEAR WARRANTIES, F LOW METER H, EXISTING CONDITIONS PIR FLOW E) ELBOW TURNING DOWN ACV 34. IF THE NATURE OF THIS CONTRACT INVOLVES EXTENSIVE REMODELING OF THE EXISTING BUILDING. THE AIR CONDITIONING CONTRACTOR, OT PRIOR TO BID, SHALL INSPECT THE EXISTING CONDITIONS AT THE JOB SITE AND ACQUAINT HIMSELF WITH THE CONDITIONS THAT EXISTING ROOF CURB DETAIL ( TYP. )- AUTOMATIC AIR VENT DRAWING TITLE: WILL AFFECT HIS WORK, 35. PRIOR TO INSTALLATION, THE CONTRACTOR SHALL COORDINATE THE EXACT LOCATION OF ALL EQUIPMENT WITH THE OWNER'S -fir- BOTTOM CONNECTION WITH SWING JOINT NOTES 4 REPRESENTATIVE AND THE ACTUAL EQUIPMENT BEING FURNISHED. LOCKING QUADRANT j M - NO SCALE AS-CURBS LEGENDS 36. PRESENT AIR CONDITIONING EQUIPMENT WHERE INDICATED ON THE DRAWINGS IS FOR INFORMATION ONLY AND THE CONTRACTOR SHALL DAMPER OPERATOR OT OVER RIDE TIMER INCLUDE THE INSTALLATION OF CONDUIT AND WIRE AS REQUIRED. THE INSTALLATION OF NEW EQUIPMENT THAT '�" DRAWN: mn INTERFERES WITH EXISTING SHALL BE REMOVED, RELOCATED, OR RE-ROUTED TO PERMIT COMPLETION OF SUCH WORK. BRANCH DUCT T THERMOSTAT 37, SALVAGED MATERIALS, EQUIPMENT, AND DIFFUSERS SHALL BE DELIVERED TO THE OWNER AT HIS PROPERTY AND STORED WITHIN THE CLASS 1 PER UL 181 CHECKED: e. BUILDING WHERE DIRECTED, ANY REMOVED MATERIALS OR EQUIPMENT WHICH THE OWNER DOES NOT WISH TO KEEP SHALL BE DISPOSED METALIZED VAPOR BARRIER OF BY THE CONTRACTOR, WITHOUT ADDITIONAL COST TO THE OWNER. O A. OUTSIDE AIR ; ' _ DATE; 02/1$/00 38. ALL PRESENT DUCTWORK AND PIPING IN EXISTING AREAS TO BE ALTERED, WHICH WILL HAVE NO USE UPON COMPLETION OF THE ''\ V SCALE: AS NOTED ALTERATIONS SHALL BE REMOVED, WHENEVER DUCTS OR PIPING ARE OR WILL BECOME EXPOSED TO VIEW, THE CONTRACTOR SHALL -� NEW CONNECTION TO EXISTING rZ ��• IMMEDIATELY NOTIFY THE ENGINEER. FLEXIBLE DUCT TAKEOFF F F - <�aQ6 3 �, PROJECT NO.: 2139.1 X00 39, THE AIR CONDITIONING CONTRACTOR SHALL DETERMINE THE EXTENT TO WHICH EXISTING DUCTWORK AND PIPING WILL HAVE TO BE RE- A io SHEET; ROUTED, RELOCATED, OR RECONNECTED, AND THE AMOUNT OF ADDITIONAL WORK WHICH MAY BE REQUIRED DUE TO THE PHYSICAL '` r. CONDITIONS OF THE DUCTWORK & PIPING SHALL BE PERFORMED UNDER THIS CONTRACT WITHOUT ADDITIONAL CHARGES TO THE OWNER_ - NO SCALE AD-FLEX6 40. INTERRUPTION OF EXISTING FACILITIES OR SERVICES SHALL BE KEPT TO A MINIMUM AND THE CONTRACTOR SHALL FURNISH ALL NOTE: THESE ARE STANDARD SYMBOLS AND ALL MAY NOT APPEAR",, Q"'lJI=ITT 0E kM' NGS, MATERIALS AND LABOR REQUIRED WHENEVER TEMPORARY CONDITIONS ARE NECESSARY TO MAINTAIN CONTINUITY OF SERVICE, - 2 INTERRUPTION OF SERVICES, THE INSTALLATION OF TEMPORARY FAGLITIES, AND THE WORK OF MAKING FINAL CONNECTIONS TO NEW WORK SHALL BE DONE ONLY AT SUCH TIMES AS PERMITTED AND SCHEDULED BY THE OWNER WITHOUT ADDITIONAL COST. THE AIR CONDI- TIONING CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE THE SERVICE INTERRUPTIONS WITH THE OWNER & GENERAL CONTRACTOR. of: