00-0222-026 w U Ir 0 ri z � 0 Nro w W Z tk A f � � f STRf BUT f ®1�l SC�fEULE FAN �N ` m °oPA CKA CE D ROOFTOP A.C. UNIT SCHEDULE o g UNIT DESIGNATION RTU-1 RTU-2 �CH ID UL E OUT51 ED E A f � FPE CA f TUL AT f ON o w �. SEE SEE SYMBOLS SIZE MFGR MODEL SERIES REMARKS TOTAL OUTSIDE 0 AREA SERVED UNIT NUMBER EF-1 EF-2 UNIT NO. AREA Sa SERVED NO.PEOPLE OUTSIDE AIR AIRANIT (CFM) REMARKS OPERATING WEIGHT, Ibs. + CURB 122 122 O 6X6 TITUS TDC- AA- 05D-6'o NK SUPPLY TOILETS ROOM MIN USED z 00 0 LOCATION ROOF ROOF AREA SERVED --- --- RTU-1 lm 20 200 200 0 � 0 - � O 12x12 5EIH0 TDC- AA- 050-84, NK SUPPLY LOCATION CEILING CEILING >_ IL It (S) EER 985 985 RTU-2 --- 10 20 200 200 --- z z ] M NOMINAL TONS N c 14X14 TITUS TDC- AA- 050-10'0 NK SUPPLY DUTY SUPPLY / EXHAUST EXHAUST o EXHAUST ° � w � Q 5 5 TOTAL AIR SUPPLY CFM 2000 2000 D 24x24 TITUS PAS- AA- OBD-100' NK SUPPLY FAN TYPE CENT CENT V go w tr z OUTSIDE AIR SUPPLY CFM 2mm 200 z (p o O E 4'-0' TITUS FL-20-1 SLOT-2'-8' INLET SUPPLY DRIVE BELT / DIRECT DIRECT DIRECT 3 = N LL i- EXT. STATIC PRESS. IN. OF H�O •80 BID FAN SPEED RPM 1200 1050 z Q z N Q wFAN MOTOR HP/FLA 3/5 53 3�' 53 AIR QUANTITY CFM 80 21� _ y SENSIBLE COOLING CAP BTU/HR 44800 44800 i 2 o 64000 64000 TOTAL STATIC PRESSURE H20' 0.250 03117 ° o rn 0 O TOTAL COOLING CAP BTU/HR O Q a 0 ~ ° 80 80 OPENING REQUIRED IN � ENTERING AIR TEMP. F DB/L IB 6'1 6'1 --' w O 1 1/2' 1 1/2' FAN MOTOR HP W WATTS_11 i I FILTER TYPE AND THICKNESS O WATTS ATTS Q FILTER SIZES CUT TO FIT CUT TO FIT ELECTRICAL CHARACT. V/j0/Hz 12011160 12011160 } TOTAL HEATING CAPACITY BTUH 11946 11946 O MANUFACTURER NUTONE PENN o TOTAL KW HEATING 35 35 O ZEPHYR Q MODEL NUMBER QT80 Z85 NOMINAL TOTAL COMP. FLA 28.8 28.8 1/2 1/2 O WEIGHT Ibs. 10 12 ° NOMINAL TOTAL FAN HP/FLA 52 52 1 2 2 3 0 w w Q AMBIENT AIR TEMP. OF DB 9 O REMARKS ��5 95 � � CONDENSING TEMP. OF MAX 125 125 O NOTES: SWITCH WITH LIGHTS O DESIGN MANUFACTURER TRANE TRANS 0 SOLID STATE SPEED CONTROL 0 L MODEL NO. TCD060- TCD060- I'1 OUTDOOR AIR PROVISIONS FOR VENTILATION SHALL SATISFY THE MINIMUM G _z C 00 C10 03 PROVIDE SWITCH CONTROL REQUIREMENTS FOR ACCEPTABLE INDOOR AIR QUALITY PER ASHARE 62-1989. Q Q It ELECTRICAL REQUIREMENTS VIWHz 24011160 24011160 O O U Jz � Q 0 dt= Up[ 0 73 1-- � Ul 0 (P U_ 2 4'-0' TITUS FL-20-1 SLOT-2'-14' INLET RETURN O 16X16 TITUS 5OF-AA-14X14 NK RETURN U Q 0 z 0 --1 NOTES: Z 1— O OREFER TO PLAN FOR QUANTITY, LOCATION AND AIR THROW PATTERN. > O J ~ J LOW VELOCITY SUPPLY Q AIR DUCT (SEE PLAN VIEW) 0 12 GAGE (MIN)WIRE DAMRVOLUME AIR I OUTSIDE AIR INTAKE SUPPORT FROM EXISTING SEAL JOINT FLOW �[ WITH DUCT INSULATE FLEXIBLE DUCT 0 SEALER 4 SUPPORT AS REQUIRED W MANUAL PAMPER TAPE FOR NO SAG. MAXIMUM I �— 23 DIAM. MANUAL VOLUME LENGTH 10'-0 {- DRAWN By p DAMPER ROOFTOP j 0 Z A.K. CONDENSATE DRAIN A/G UNIT 1/4' BIRD SCREEN _� M DRAW AIR U (SEE SCHEDULE) RUST RESISTANT FIBROUS DUCT A BAND 0 REvis:oNs (SEE PLUMBING DWGS.) • FLOW SPIN COLLAR FITTING WITH �^ 4 FLASHING QUADRANT OPERATOR TO BE z (SEE ARCH. DWG) OUTSIDE INSULATION PROVIDE 0 INSULATION GUARD WHERE FINISHED 10' MIN �� �� INSULATED VAPOR LL ROOF �\� SPIN COLLAR W/ SEALED COLLAR t DIFFUSER NECESSARY. ° FASTENER � 1/2' BOLTS 24' O.C. (TYP) ���� FLASHING 14' HIGH MANUFACTURER / / ��\� �.\\ DAMPER AND BACK PANEL EXTRACTOR SEAL JOINT WITH DUCT Z BUILT-UP ROOF ROOF CURB I' EXPANTION \.\ ��� SEALER t TAPE Z —� WOOD CANT BOLT C4 TYPJ r CRETE DIFFUSER d O DATE -- CONCRETE DECK } 01/21/9& RIGID INSULATION 2'x2'xl/8' 6'0 SHEET METAL GALVANIZED NOTEt, t< EXHAUST DUCT CHANNEL PLACE SUPPORT AT 8'-0' 0 FLEXIBLE GONN, 1 1/2' EXPANSION BOLTS ® 24' O.C. (TYP) ON CENTER FOR DUCTS UP z (TYPICAL) ® _-- I EMBEDMENT J L JIIL TO 35' AND V-0' FOR DUCTS ,Q UP TO 59', AS PER SMACNA SMOKE DETECTOR � . 1 m I f l STEEL JOIST TOILET EXHAUST VENT CAP DETAIL � 1 S/AIR R/AIR N.T.S RECTANGULAR DUCT SUPPORT DETAIL FLEXIBLE DUCT CONNECTION DETAIL N.T.S. ,/'��•"0 A/C UNIT (ROOFTOP) INSTALLATION DETAIL 11/2' MIN. HANGER STRAPSr N T.S SUPPORT FROM EXISTING STRUCTURE (26 GAUGE) N z LU 0 U 0 Z Qi FIBROUS ROUND AND FLEXIBLE SHEET METAL DUCT a I SADDLE MIN. 5'-0' ON CENTER 6' MIN. ' r _V NOTE_ z HANGERS SHALL BE LOCATED AT DUCT JOINTS OR AS CLOSE AS POSSIBLE. 0 ROUND DUCT SUPPORT DETAIL Q KT.& a d SHEET NO I � 0 2x 0 I Puga and Associates, Inc. z OF Engineers/Consultants 2 # EB 0005813 rM 4970 S.W. 72 Avenue, #107 Miami, Florida 33155 COMM NO (305) 661-7700 9B 41