00-0222-012 - - U I,n 2 O (0
z 0 N '
W W Z r °
U =_ Q I
N S
GALV. REGLET, FLASHING,
NEW 8 MASONRY PARAPET 0
GALV. REGLET, FLASHING, " AND GOUNTERFLASH BY
-- — — 8" MIN. CONC. WITH 8" MIN. DEEP CONT. "TAMCO" a U g J
AND COUNTERFLASH BY
TAMGO PARAPET GAP: SEE PARAPET CAP BUILT SEE DETAIL "B" BELOW ° Z � �
STRUGT. DWG'S. ON EXISTING PARAPET 0
A/C ROOFTOP
■ 0
U
EQUIPMENT--SEE
�` 0
MECH. DWG'S. I V2 I�
V2" MIN. U � � � � I
+ 23'-9" + 23'-9" A BUILT-UP T. t G. z
Q a F-
PARAPET
�; NEW PARAPET
I
ROOF ON RIGID R-19 Q 0 N
° INSULATION
BUILT-UP T. t G.
ADD NEW 8" MASONRY PARAPET OVER • • •; ' ° w I,- C)
BUILT-UP T. t G. ROOF ON RIGID R-19 0
ROOF ON RIGID R-19 INSULATION EXIST. TO NEW ELEV. SHOWN ° 0 0
INSULATION CONC. ROOF SLAB ON F
STUCCO 4 PAINT TO MATCH EXIST.
CORRUGATED METAL a = a
- - DECK--SEE STRUCT. DWG'S. Z O Q n Q
Y
TIE 5EAM + 21'-6�/z° SEE STRUGT. DWG'S. w 0
EXIST. CONC. CAPV FOR SIZE t SPACING
SEE STRUGT. DWG'S. °a v
-- OF JOISTS I i o m 0
0 7 Q to V)
SEE STRUGT. DWG'S. FOR SIZE t SPACING
FOR SIZE < SPACING OF JOISTS CONC. T.B.--SEE EXIST. CONC. PARAPET CAP Q
OF JOISTS - o STRICT. DWG's. STEEL ANGLE LEDGER--
I
EXIST. T. 4 G. ROOF SEE STRUGT. DWG'S FOR
SIZE AND CONNECTION F
DETAILS
A/C SUPPLY DUCT-- I 8" MASONRY WALL EXIST. ROOF DECK 0
SEE MECH. DU1G'S. AND JOISTS —_._—_ °
II - z
0
z
Q
I CEILING = N -
+ IV-0"" I I CEILING bib" STUCCO 7YP.
CEILING o
EXIST. GONG. T. BEAM �'e" GYP. D W. CEILING z
ON METAL CHANNEL FRAMING z
w
SEE STRUGT. DWG'S. I I 2' x 2' ACCOUSTIC TILE
FOR SIZE OF ST. BEAM DROP CEILING + IS'-0" �_
EXIST. CEILING
N8" GYP. D.W. ON 3/4" P.T. GC'
I WD.FURRING W/ R-5 INSULATION _ 4 lU
I
NO,, GYP. DIU. ON 3/4" P.T. •• + I6'-8" °
NO-- GYP. D.W. ON I I WD. FURRING W/ R-5 INSULATION EXIST.GYP. DIU.— FIN. DOORWAY HEAD z Z
PATCH AND PAINT AS
GALV. METAL CHANNEL m
� m
Q
FRAMING I I SIMILAR REQUIRED • �- m
NEW 8" MIN. DEEP GONG. w [Q Z n d
NO,- GYP. D.W. ON 4" (NOM-) I I LINTEL WITH 2 05 CONT.--
GALV. METAL CHANNEL EXTEND 8" MIN. INTO MASONRY
PARTITION I I EITHER SIDE OF NEW OPENING o 5 V
STEEL COL. BEYOND: T
T. D O
SEE STRUGWG'S. AROUND DOORWAY
NEW WOOD CASING AND FRAME a
REMOVE MASONRY WALL TO °
CREATE NEW 4'-0" WIDE DOORWAY J V Z
I Q -p
Its
I I REMOVE EXIST. SLAB AS INDICATED
EXIST. CER. TILE EXTEND NEW SLAB POUR TO Q Q
MATCH FIN. FLOOR ELEV. AT EXIST. N Q
WOOD BASE TILE FLOOR a Q
II
IIZ
3/4" RECESS FOR °
U
CONIC. BLOCK
W
I
f- DRAWN B`
I I z A.K.
10'-0" °
F+. FLOOR + 10'-0° /� •..� .: o ,. ' H
a eo • < 4. 4 e a.aa• .. .d. e: :. .4, q. ea d ° • ' =A\�_ .
- e a a e ..4 a q' 'ae • 'q• ° — I ,� .. REVISIONS
EXIST SLAB
o
II ° e 0
�— Z
I I z
0
a
I 2 DATE
U -21-9E
UJAL L SECTION
}
5 WALL
I LL SI E CI I T I OiLL
4 WALL SECTION I I 1 I _ I I Z 0 3/4 =
3/ II _ I _ 0II 45 3/4 _ � � � o
,� 4 SC/
i m
• 0
Z
Z
T AN ASH -
s . GALV. METAL REGLET D COUNT ERFL
° U
BY "TAMGO." GUT REGLET INTO GONG.
PARAPET GAP W/ 1/2" X 11/2" SAW-GUT °
��2 11 TYP. a
GROOVE. FILL GROOVE W/ CAULK CONT. W
SEE STRUGT. DWG'S.
0
FOR SIZE d SPACING ( °
OF JOISTS T. � G. BUILT-UP ROOFING 1 �
a °
I Z
a
A/C, SUPPLY DUCT-- I Z
SEE MECH. DWG'S.
� •a a
LINEAR DIFFUSER BY RIGID ISOCYANURATE INSULATION °
TITUS. SEE MEGH. TAPERED FROM 10" THK 6 FRONT OF d
D�,S BUILDING TO APPROX. 2" THK -0 REAR.
MATERIAL SHALL COMPLY WITH 11190 SPEC." '
AND SHALL HAVE DADE COUNTY PRODUCT
+ 20'-0"
CONTROL APPROVAL
CEILING: U
+ 221-011
h
w
5/811 61/2 u _
ROOF DEC °. ° °.. �
fG
GYP. D.W. CEILING ON --��--'-----�:--�:-„"r'_.��' I
METAL CHANNEL a
Q
FRAMING p GONG. ROOF ON GALV. METAL DECK a
SEE STRUGT. DWG'S. Q
11 2 SHEET
+ 1131-0 p
CEILING
I
tit
r /
z of
ONT. G=YP. D.W. SOFFIT
M` SEVE
G i� i` i� �1" DETAIL
co
COVE LIGHT FRAMED WITH 1�
\ / ICS DETAIL
METAL CHANNELS-- •, , �•,.� . , � � COMM
SEE ELECT. DWG.S FOR 45 11/2 '
s 1 v
1/ FIXTURE_ ► II FIXTURE SPEC. r sa
,�5 12 1 ° O