00-1335-025 420 �\ Al C -�-- All All All All Al 419 421 A11 Al Al 4�3 425 A15 ELECTfRICAL 425 A19 A14 AI GENERAL LEGEND a Al JUNCTION BOX Al2 II 14 A14 1 21041 SWITCH 4l1 FLUORESCENT d- 4�41 412 LAMPS TREE WAY SWITCH A15 A14 Al A4 ❑ FLUORESCENT LAMP 431 t A!2 u WHITE SIPPED Ail A14 �"� � PHONE LIGHT � BAFFLE m � 412 All � RECEPTACLE $42E, Alr Al2 a14 Al2- Al ?� TELEVISION . � O � WALL SCONCE A?�2 /`` �� g �� �/ m \. 4,12 '�` � A� 4)2 - � `� EMERGENCY LIGHT (� m X All f4?411i, 425 EXIT LIGHT 419 � 424(b '� _j -1 Alto A (o AIC Also A FIRE ALARM - f _ - a A� O Z 1� z � A29 A29� T 429 � � �i � � 2 2 2 F � AS ca 410 A10 410 A2 NOTE - C'Z (P A10 1. SHOP DRAWINGS WILL BE SUBMITTED FOR ONLY REQUIRED `- ALTERATIONS TO THE FIRE SPRINKLER SYSTEM A3 42 42 2. FIRE ALARM SUBCONTRACTOR SHALL SUBMIT SHOP DRAWINGS FOR APPROVAL BEFORE WORK IS TO 433 COMMENCE TR 4112-8 A3 BLACK GIMBALL A9 A A A9 TRACK HEAD AS A8 3 A28 42a FI Cs 4' 48 �� � �A3 � vt AS 43 3 3 � �, • A ul O } 3 5/8'X25 GAUGE METAL STUDS 0 jM'•`` c 4�o Ago A6 A/o_ NEL A WITH 9 CAA. WARE AT A MAX. DIST. OF NEL A m 46' APART W i N A3 43 gi P NEL B _1 QL ±l'• Q� 13 A13 41 10 1-4 B3 52 B2 B I 'J R TR 4112-8 Ag F TRM40W BLACK GIMBALL WHITE STEPPED BAFFLE TRACK HEAD A4 AS B12 B?0 E311 ll 1 Ul _II A4 A4 4 A21 B5 B5 ►- 6 B O Q r---- L IC NTS 5GHEDUL Q 2102' L Ir-3W TYPE 51ZE STYLE rIAX FLUORESCENT NO UJaTT LAMPS 01 TR 4112-8 LENGTH 1' - DIAMETER BLACK GIMBAL TRACK 15 4' HEAD L I f HT f NC3 AND CEILING FLAN 02 TRM40W OUTSIDE DIAMETER 1 1/4' WHITE STEPPED BAFFLE 150 03 FLUORESCENT 4'-2' 4 2'•2' LIGHT FRCF05ED E FLAN J��t SCALE 1/411 = 11 -011 to -1 Q GENE SAL. E L E C,7 IC N07E e - I. ALL ELECTRICAL WIRING SHOULD 8E CONDUIT. Q 2. ELECTRICAL EQUIPMENT EXPOSED TO WEATHER SHALL E3E WEATHERPROOF. U 3. CONDUIT EXPOSED TO WEATHER OR IN CONTACT WITH CONCRETE SHALL BE GALVANIZED HEAVY WALL STEEL. � O 4. ALL ELECTRICAL EQUIPMENT SHALL BE U.L. APPROVED AND SPEsCIFFICATION C3RADE. �, Z O 5. FLEXIBLE CONDUIT CAN ONLY E3E USED SHORT FINAL CONNECTIONS TO INTERIOR LICsHTINOz FIXTURES AND EQUIPMENT. 6. NO CONDUITS SHALL BE RUN IN OR THROUGH DUCTWORK -1. TEMPORARY ELECTRICAL SERVICE SHALL BE FURNISHED BY TENANT'S ELECTRICAL CONTRACTOR AT CONTRACTOR'S EXPENSE. / �- 8. ALL TEMPORARY WIRING IS TO f3E REMOVED WHEN TENANT'S ELECTRICAL SERVICE AND PERMANENT WIRINCx ARE COMPLETE. LL 9. MINIMUM WIRE SIZE SHALL 8E "12 A.W.Cz COPPER. ALUMINUM WIRE IS PERMITTED IN SIZE *2 AND LARGER IF ACCEPTABLE TO / THE LOCAL AUTHORITIES HAVING JURISDICTION. 10. WIRE RATED AT 180 IDEGREES CENTIGRADE I$ REQUIRED FOR ALL INCANDESCENT LIGHTING FIXTURE THAT ARE NOT I-REWIRED. 11. ALUMINUM CONDUIT. IF USED, SHALL BE E3ONDEDAT EACH POINT IT ENTERS A STEEL RACEWAY. JUNCTION BOX OR PULL BOX WITH N '-' 4' �CN AN APF=OVED GROUND E3U5HINCi AND BARE COPPER. CONDUTORS SIZED IN ACCORDANCE WITH ARTICLE 250-B5 OF THE N.E.C. ALUMINUM CONDUIT SHALL NOT B INSTA UN E LLED DERCaROUND �I OR IN CONTACT WITH CONCRETE. _ ANTISIZING COMPOUND SHALL BE APPLIED TO ALL THREADS. 12. ALUMINUM WIRE, IF USED, SHALL BE INSTALLED USING THE PROPER COMPATIBLE LUGS AND CONNECTORS WITH ANTIOXIDANT COMPOUND APPROVED FOR ALUMINUM WIRE. U (ALUMINUM WIRE SHALL NOT €3E INSTALLED IN DIRECCT CONTACT WITH COPPER WIRE.) L-''��-C<G 3 �'�� ��� `"� -EN4ti` Z& 13. ALL ELECTRICAL WORK SHALL BE INSTALLED IN ACCORDANCE WITH THE LATEST NATIONAL ELECTRICAL CODE AND ALL APPLICABLE FEDERAL STATE AND LOCAL CODES. X E L O 14. ALL UNDERGROUND CONDUIT SHALL BE GALVANIZED HEAVY WALL STEEL ASPHALTUM PAINTED AND WRAPPED WITH ANTICORROSION TAPE OR SCHEDULE 40 PVC WITH PROPER SIZE EQUIPMENT GROUNDING CONDUCTOR ALL SWEEPS AND ABOVE FLOOD EXTENSIONS SHALL BE GALVANIZED HEAVY WALL STEEL. 15. 5EALTITE LIQUIDTIDE FL ISLE CONDUIT SHALL NOT EXCEED 6 FOOT IN LENGTH AND' SHALL HAVE A COPPER GROUNDING CONDUCTOR EITHER INSIDE OR OUTSIDE THE CONDUIT. `CO 16. FIXTURE WIRING OR BRA�H CIRCUIT WIRING RUNNING PAST A FLUORESCENT BALLAST SHALL BE RATED AT 9O DEGREES CENTIGRADE MINIMUM. 1-7. A DISCONNECT SWITCH IN ACCORDANCE WITH ARTICLE 600-2 OF THE N.E.C. 15 REQUIRED FOR ALL TENANT STOREFRONT SIGNS. A CIRCUIT BREAKER LOCK DOG OR TIME SWITCH DO NOT MEET THE LOCKED-OPEN REQUIRMENT5 OF THIS ARTICLE, I8. EXIT LIGHTS PER NATIONAL ELECTRICAL CODE AND STATE AND LOCAL CODES ARE REQUIRED. }- 19. ELECTRICAL RISER DIAGRAM IS REQUIRED IN DETAIL SHOWING ALL PANEL FEEDER SIZES AND THE SIZE OF THE MAIN SERVICE CONDUCTORS. U Z 20. EXIT LIGHTS SHALL BE DUAL CIRCUIT TYPE WITH A BRANCH CIRCUIT FED FROM PANEL AND AN EMERGENCY CIRCUIT FED FROM A BATTERY UNIT OR GENERATOR U1 21. DRAWINGS SHALL BE CIRCUITED AND LOADS BALANCED. � � 22. FEEDS FOR HVAC UNITS INCLUDING WIRE AND CONDUIT SIZES AND SIZES OF OVERCURRENT PROTECTIVE DEVICES FOR THE UNITS. ALL HVAC UNITS SHALL NAVE FUSE PROTECTION. "�� °� ` -`\E- - - O 23. ,4 WEATHERPROOF OUTLET IS REQUIRED MOUNTED ADJACENT TO HVAC UNIT ROOF. 200 '00 24. TIE INTO METER POINT SHALL BE INDICATED ON TENANT'S ELECTRICAL DRAWINGS. Q 25, HOOD PROTECTION IS REQUIRED-4 SELF CONTAINED (DR CHEMICAL OR (CO)2 AUTOMATIC EXTINGUISHING WITH AUTOMATIC FUEL SHUT OFF IS REQUIRED, HIGH TEMPERATURE HEAD IS DRAWING; NO. ALSO REQUIRED FOR THE HOOD 5Y5TEM. 26. NO CHANGES ARE BEING MADE TO THE HVAC 5YY5TEM. 21. THE FOOD COURT FLOOR TILE IS ALREADY INSTALLED. 28. NO CHANGES ARE BEING MADE TO THE SPRINKLER SYSTEM, 29. CONDUCTORS REATED 150 AMPERS OR MORE MAY BE COPPER. OR ALUMINIUM, WITH APPROVED COMPRESSION FITTINCsSt ALL OTHER CONDUCTORS SHALL BE COPPER 30. CABLE TYPES AC AND NM ARE NOT ALLOWED. FR 5 E FR D 1 /4 G FR A r� 31. IF USED, FLEXIBLE TYPE MC CABLE SHALL HAVE A BLEU STRIPE, 32. CONDUCTORS SHALL BE COLOR CODED AS STATED IN THE TENANT HANDBOOK. 33. CIRCUIT BREAKERS SHALL BE BOLT-ON TYPE. 7- l O T T O S C �.L 34. GROUNDS ON THE SEPARATELY DERIVED SERVICES SHALL BE BONDED TO THE BUILDING 5TELL WITH EXOTHERMIC WELDS.