Loading...
00-0833-016 e I GENERAL NOTES 1. COORDINATE NEW DUCTWORK AND EQUIPMENT WITH LIGHTING, PLUMBING, STRUCTURAL SYSTEMS AND CEILING SYSTEMS, 2. DUCT ACCESS PANELS ADEQUATE FOR SERVICE SHALL BE PROVIDED AT LEGEND ALL DAMPERS AND CONTROLS 3 CONTRACTOR SHALL COORDINATE LOCATION AND SIZE OF ALL PENETRATIONS THROUGH WALLS, CEILING AND FLOOR WITH OTHER ARI AMERICAN REFRIGERATION INSTITUTE O DRAWING REFERENCE NOTE TRADES, , CAP. CAPACITY 4, ALL DUCT SIZES SHOWN ARE ACTUAL AIR PATH SIZES CFM CUBIC FEET PER MINUTE DIAMETER 5. CEILING ACCESS PANELS SHALL BE PROVIDED FOR EQUIPMENT, CLG. CEILING DAMPERS AND CONTROLS INSTALLED ABOVE OTHERWISE NON- International COMP. COMPRESSOR THERMOSTAT, ROOM ACCESSIBLE CEILINGS ACCESS PANELS SHALL NOT BE LESS CNN, CONNECT, CONNECTION CWR CONDENSER WATER RETURN FLEXIBLE DUCT THAN 20 X 20' . Design P artn e r s hip CWS CONDENSER WATER SUPPLY NEW DUCTWORK OUTSIDE AIR CALCULATIONS 6. MOUNT ROOM THERMOSTATS 5 FEET ABOVE FL❑OR. t" DB DRY BULB 7 ALL EQUIPMENT LOCATED OUTSIDE SHALL BE CONSTRUCTED AND DN DOWN �fla--� GATE VALVE TOTAL GROSS AIR CONDITIONED AREA. , , , , 3346 S, F INSTALLED TO WITHSTAND A WIND PRESSURE OF 60 POUNDS PER Incorporated SQUARE FOOT FROM ANY DIRECTION DWG DRAWING EA EACH MANUAL VOLUME DAMPER GROSS OFFICE AREA , , , , , , , , , , , , , . 2755 S F, 8. DUCTWORK PENETRATIONS OF WALLS SHALL BE SEALED AIR AND NET OFFICE AREA , , , , , , , , , , , 2066 S. F. WATER TIGHT, hta Drive EER ENERGY EFFICIENCY RATIO _ 30 W. NfDrive ENT, ENTERING FIRE/SMOKE DAMPER 9, NO EQUIPMENT OR MATERIALS SHALL BE PURCHASED OR INSTALLED EQUIP EQUIPMENT 2066 S F, /1000 S F X 7 P) 15 PEOPLE PRIOR TO FINAL APPROVAL OF SHOP DRAWINGS Biscayne,Biscane, Fl 331,19 EXT. EXTERNAL 15 PEOPLE X 20 CFM/PX = , , , 300 CFM 10, EXISTING EQUIPMENT, PIPING, DUCTWORK, OUTLETS, CONTROLS, Tel: 30.1'365.8338/ Fax: 308.368.8339 FLA FULL LOAD AMPS ETC. WHERE S❑ NOTED SHALL BE REMOVED OR RELOCATED AS PART -mail: IDPmia aol.com HP HORSEPOWER TOTAL GROSS LUNCHROOM AREA. , , , 591 S, F. OF THIS CONTRACT. KW KILOWATTS NET LUNCHROOM AREA. , , , , , , , 443 S F 11 THE CONTRACTOR SHALL PROVIDE A SET OF PRINTS CLEARLY MARKED TO - - L&S LOUVER AND SCREEN SHOW AS-BUILT CONDITIONS AT THE COMPLETION OF CONSTRUCTION �o. ItiLE Date MAX. MAXIMUM 443 S, F, /1000 S F, X 70 Px _ 31 PEOPLE 12. FLOOR SLABS ARE POST TENSIONED STRUCTURES. STEEL REINFORCING MIN, MINIMUM 31 PEOPLE X 20 CFM/Px _ , , , , , 620 CFM SHALL BE LOCATED AND CAREFULLY AVOIDED WHEN CUTTING NEW MVD MANUAL VOLUME DAMPER OPENINGS NTS NOT TO SCALE TOTAL REQUIRED OUTSIDE AIR. , , , , , 920 CFM TOTAL OUTSIDE AIR PROVIDED BY AC-1, AC-2, AC-3 ❑/A OUTSIDE AIR & O/ PRESSURE DROP AC-4. , , , 925 CFM -- -- - - -- PSF POUND PER SQUARE FOOT x IN ACCORDANCE WITH ASHRAE 62-1989 QTY QUANTITY R/A RETURN AIR RLA RUNNING LOAD AMPS --- -- ---- -- - RPM REVOLUTIONS PER MINUTE S/A SUPPLY AIR S F. SQUARE FEET SIP, STATIC PRESSURE TYP. TYPICAL V/PH VOLTAGE/PHASE W/ WITH - -- ----- -- - WB WET BULB CLIEtiT APPRO`-AL I have reviewed these plans and have been given the oopor,.unity to ask questions about them prior to issue. These plans conform to our requirements I understand that any modifications to these plans will be an additional service with potential impact on construction cost and scheduling ACCEPTED AS I6 ACCEPTED AS NOTED Signature Date WATER COOLED HEAT PUMP UNIT SCHEDULE All d aw'rc, and wri,ten ma+er;al herein, as instrimen s MASONRY SUPPLY OUTSIDE EXT. MAX. SENS. TOTAL ENT. AIR WATER ENT. WATER STEPS COMP. FAN HEAT of service; shay: remain the property of 'nternational WALL MARK MAKE MODEL TYPE HP FACE V/PH EER Design Partners'__ip 'nc. (IDP) and small not be reproduced 1' MINIMUM OVERLAP AIR AIR S.P. VEL. BTUH BTUH DB�WB FLOW WATER P.D. OF CAP. RLA FLA BTUH or co Pd, in who'e or in part, wtt_lout the expressed ON ALL SIDES p � �. AC-1 CLIMATEMASTER HS060 HORIZONTAL PACKAGE 1700 415 0.7' 1.0 408 45000 60000 80.0 67.0 16.2 GPM 85.0'F 17.0 FT 1 208 3 16.1 5.8 73000 11.2 written consent of IDP and znav not be used or \� 1/4' M I N I MUM AC-2 CLIMATEMASTER HS096 HORIZONTAL PACKAGE 2800 250 0.7' 1.5 336 67260 92600 80.0/67.0 24.8 GPM 85.0'F 19.3 FT 2 208/3 2: 13.8 EA. 7.5 1 1 1 150 11.0 referenced for an other project r.forrlation ccn ar.ed \ _ AC-3 CLIMATEMASTER HS060 HORIZONTAL PACKAGE 1735 260 0,6' 1.0 416 45180 60700 180.0/67.0116.2 GPM 85.0'F 17.0 FT 1 208 3 16.1 5.8 73000 11.2 herein represents proprietary into oration of :r.ternat'.onal Des.gn Partnership and or its '!-.er_t and shall not be NOTES disclosed to o±hers Those who use these documents DUCT--' 1, COMPRESSORS SHALL HAVE A 5-YEAR EXTENDED WARRANTY. do so in confidence. 2 A SMOKE DETECTOR SHALL BE INSTALLED IN THE S/A DUCT OF UNITS IN ACCORDANCE WITH NFPA 9CA SMOKE DETECTORS ARE SPECIFIED UNDER ELECTRICAL, 3 THERMOSTATIC EXPANSION VALVES SHALL HAVE A BROAD MODULATING RANGE, EXTERNAL EQUALIZING LINES SHALL BE TAPPED INTO SUCTION LINES DOWNSTREAM OF THE EXPANSION VALVE SENSING BULBS, --- - - - - - - � DAMPER FRAME 4. HORIZONTAL UNITS SHALL HAVE 1' THICK FLAT THROWAWAY FILTERS LOCATED IN FILTER BACK GRILLES, Architect of Record: 5. INSTALL UNITS ON EXTERNAL SPRING ISOLATORS Charles Nlyers 6, UNITS SHALL BE COMPLETE WITH LOW PRESSURE SWITCH, ANTI-SHORT CYCLE TIMER AND ROOM THERMOSTAT WITH AUTOMATIC CHANGEOVER, OVERCENTER LOCK--,\\ State of Florida '� � S-JOINT AR0014-46 /( SLEEVE TO DUCT) DUCTS ' '-MOUNTING ANGLES 6' MIN, 11 -//? 16' MAX. INTERVAL FIRE/SMOKE DAMPER INSTALLATION DETAIL NTS INTERNATIONAL 4th Floor 6262 Sunset Drive Miami, Fl 33143 HVAC DESIGN REQUIREMENTS CONDENSATE DRAIN PAN GAUGE CONNECTION HVAC DESIGN REQUIRES: YES N & VENT DUCT SMOKE DETECTOR X Owr_er� eff �;eiss FIRE DAMPERS X 433 _ _aaa Real, uite 27 THERMOMETER WELLS C TYR� -CWR SMOKE DAMPERS X Boca Raton, FL 333 x FIRE RATED ENCLOSURE X Contact: Jeff ti�eiss (061) 416-4600 ISOLATION FIRE RATED ROOF/FLOOR X BALANCING VALVE � /AxB � � VALVES '�CWS CEILING ASSEMBLY - f AIR VOLUME UNION (A+C)xB EXTRACTOR �- �,_ BRANCH DUCT OR SMOKE CONTROL X X 04-00 �SIDEWALL OUTLET COLLAR Date: MVD ,- PERFORATED CLEANOU� Project NO: 8086.10 Drawn By, 8JB Checked 3y: JEa AIR FLOW SIZE AND DEPTH OF TRAP �� CADD File 00-015(MECH VCAL) dwg i r MVD AS RECOMMENDED BY UNIT---,,,,, - --- - - � MANUFACTURER � AC UNIT � GAUGE - - -- - DxB" & DRAIN �DISTRIBUTION DUCT Title. J UNION OR FLANGES (TYP) CxB AT 1/ TO DRAIN SCHEDULE DETAILS AT 1/8' /FT. �� , TYPICAL DUCT TEE DETAIL TYPICAL DUCT TAKEOFF DETAIL A/C CONDENSATE DRAIN DETAIL CONDENSER WATER CONNECTION DETAIL LEGEND & NOTES NTS NTS NTS A " NTS �PriGCN+P�1;eZ� f . ' �' v `f A fi NDERSON ILLIAMS CONSULTING ENGINEERS INC. ° F. ' 117 MAJORCA AVE. CORAL CABLES, FLORIDA 33134 TELEPHONE (305) 442-8033 AWCE JOB#: 00-05 1 �::eet NuLmber of: -t