00-0833-001 I ARCHITECTURAL ABBREVIATIONS ARCHITECTURAL SYMBOLS INDEX OF DRAWINGS ABV ABOVE IN INCH A/C AIR CONDITIONING INCL INSULATED)(ING) ACT T ACOUSTICAL TILE INT INTERIOR ARCHITECTURAL DRAWINGS AC ACOUSTICAL INS IN ERIOR(D),(ION) 804 ROOM NUMBER ADD ADDENDUM ADH ADHESIVE JAN JANITOR ADJ ADJACENT JC JANITOR'S CLOSET A— 1 C OVER ADJT ADJUSTABLE ELEVATION International ALUM ALUMINUM LAB LABORATORY -LAM LAMINATED —SHEET NUMBER A- 2 SYMBOL, LEGEND, KEY PLAN, INDEX ANOD ANODIZED LAV LAVATORY Design Partnership AP ACCESS PANEL LHL EFF HAND 3 ELEVATION A- 3 DEMOLITION PLAN APPROX APPROXIMATE Incorporated ARCH ARCHITECTURAL LT LIGHT 2 ,} A-5 A- 4 PARTITION PLAN p SHEET NUMBER Avc AVERAGE A— 5 POWER & COMMUNICATION PLAN MAX MAXIMUM s SECTION 30 W. Mashta Drive BD BOARD MECH MECHANICAL(AL) - SHEET NUMBER Key Biscayne, F1 33149 MFR MANUFACTURE(ER) REFLECTED A- 6 REFLECTED CEILING PLAN Tel: 305.365.8338,/Fax: 305.365,8339 BLDG BUILDING MIN MINIMUM BLKG BLOCKING MISC MISCELLANEOUS A— ELEVATIONS E-mail: IDF'mia®aol.com MTD MOUNTED CAB CABINET s DETAIL CG CORNER GUARD NI NOT APPLICABLE - SHEET NUMBER A- 8 DETAILS No. Issue Date NO NOT IN CONTRACT 1 . Permit 03-09-00 c R CLEARANCE) NO NOMINAL ALIGN A— DOOR & FINISH SCHEDULES/SPECIFICATIONS CLO CLOSET NTS NOT TO SCALE � ALIGN W/ESTABLISHED SURFACE COL COLUMN OC ON CENTER A- 10 FLOOR FINISH PLAN CONC CONCRETE 5 — DETAIL CONF CONFERENCE OPNG OPENING - — SHEET NUMBER A- 11 SPECIFICATIONS CONST CONSTRUCTION OPP OPPOSITE CONT CONTINUOUS, CONTINUE CORR CORRIDOR CTR COUNTER DETAILED AREA _ CPT CARPET P.LAM. PLASTIC LAMINATE CT CERAMIC TILE SEE M.E.P. DRAWINGS FOR ENGINEERING LEGEND - CTR CENTER PNL PANEL PTD PAINT(ED) DBL DOUBLE PR PAIR DEMO DEMOLISH, DEMOLITION PSF POUNDS PER SQUARE FOOT DEPT DEPARTMENT PSI POUNDS PER SQUARE INCH DTL DETAIL PT PRESSURE TREATED DF DRINKING FOUNTAIN PTN PARTITION PLYWD PLYWOOD CLIENT APPROVAL DIA DIAMETER DIM DIMENSION QTY QUANTITY I have reviewed these plans and have been DISP DISPOSAL RAD RADIUS given the opportunity -o ask questions about DN DOWN RA RETURN AIR them prior to issue. These plans conform DR DOOR to our requirements. I understand that any DW DISHWASHER REC RECESSED modifications to these plans will be an DWG DRAWING additional service with potential impact on DWR DDRAFWER REFR REFRIGERATOR construction cost and scheduling. EA C EL ELEVATION REQ'D REQUIRED ACCEPTED AS IS ELEC ELECTRICAL REV REVIS ION(S),REVISED ACCEPTED AS NOTED ELEV ELEVATOR RH RIGHT HAND Signature: Date: EQ EQUAL EQUIP EQUIPMENT RM ROOM EWC ELECTRIC WATER COOLER EWH ELECTRIC WATER HEATER EXIST EXISTING SC SOLID CORE EXT EXTERIOR SCH SCHEDULE All drawings and written material herein, as instruments FA FIRE ALARM of service, shall remain the property of International SHT SHEET Design Partnership, Inc. (IDP) and shall not be reproduced FAP FIRE ALARM PULL SIM SIMILAR or copied, in whole or in part, without the expressed FD FLOOR DRAIN written consent of IDP and may not be used or SPEC SPECIFICATIONS) referenced for any other prcject, Information contained FE FIRE EXTINGUISHER SQ SQUARE herein represents proprietary information of International FEC FIRE EXTINGUISHER CABINET SS STAINLESS STEEL Design Partnership and/or As Client and shall not be FF FINISHED FLOOR STD STANDARD disclosed to others. Those who use these documents FHC FIRE HOSE CABINET do so in confidence. 5TL STEEL FIN FINISHED) F1 XT FIXTURE STO STORAGE SUSP SUSPENDED Architect of Record: �+ ►� �"1°�!!e�!, 'f R SYM SYM M ETRY(ICAL) Charles Myers •�`� �,s -�w' ','f,• �.y°e , FLR FLOOING) e` c FOF FACE OF FINISH TEL TELEPHONE FLUOR FLUORESCENT TEMP TEMPERED State of Florida THK THICKNESS) Registration # �AR0014546 'v <�`rl KEY PLAN FR FIRE RATED TV TELEVISION J 1 & FS FIRE STROBE TYP TYPICAL FT FOOT, FEET TZ TERRAZO FUR FURRED(ING) FWC FABRIC WALLCOVERING GA GAGE, GAUGE UL UNDERWRITER'S LABORATORY GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE U v6 VINYL BASE �N T E RVAL GL GLASS, GLAZING VCT VINYL COMPOSITION TILE A a VERT VERTICAL HM z VEST VESTIBULE INTERNATIONAL GWB GYPSUM WALLBOARD VWC VINYL WALLCOVERING GYP.BD. GYPSUM BOARD r WC WATER CLOSET/TOILETS 4 r � ° HC HOLLOW CORE WD WOOD 4th Floor W/O WITHOUT + HM HOLLOW METAL I� Q Q o 6262 Sunset Drive HR HOUR F1 33143 HT HEIGHT Miami, PARKING GARAGE HVAC HEATING/VENTILATING/AIR COND. — 0 Q 0 Owner: Jeff Weiss 433 Plaza Reel, Suite 275 Boca Raton, I'L 33432 Contact: Jeff Weiss, (531) 416-4600 ® Date: 02-29-00 PROJECT LIMITS Project No: 8056,11) Drawn By, kt NOT TO SCALE/DOES NOT REPRESENT EXACT S.F. Checked By: mb CADD File as-idp\,interval\04\ .dwg Title: INDEX IKEY PLAN 4TH FLOOR SYVBOLS & NOTES: ABBREVIATIONS 1 . TENANT AREA IS ±3,631 U.S.F. SCALE: 1/4 = 1'-0° 2. REFER TO LARGER SCALE DRAWINGS FOR EXACT LOCATION OF DEMISING PARTITIONS Sheet NO.: .�