00-0799-010 i
PLUMBING NOTES: '
■ �' uL „
I. ALL WORK TO BE IN ACCORDANCE WITH THE LOCAL PLUMBING CODES. -- #
�/■ v E-=
2. BUILDING DRAINAGE SYSTEM BASED ON 1/8" / FT. MINIMUM FALL. ANY DEVIATIONS li
SHALL BE APPROVED BY ARCHITECT AND ENGINEER.
as ✓
3. CONTRACTOR TO PROVIDE I" (MIN.) WATER PIPE GAPPED AT EVERY ELEGT2IGAL
5WITCHGEAR ROOM OR METER ROOM TO BE USED AS GROUND. >
4. ALL VALVES UNDERGROUND TO BE INSTALLED IN PRECAST GONGRETE BOXES, BROOKS, �-• r
OR EQUAL.
5. PLUMBING CONTRACTOR TO FURNISH ALL REQUIRED FLASHING FOR PIPES TO ROOFING ._
GONTRAGTOR.
(q. MATERIALS SHALL BE ALL NEW AND AS FOLLOWS: W
A) DRAINAGE PIPING - NO HUB CAST IRON 5TD. 301 OR PVG-DWV 5GH. 40 w
B) WATER PIPING - TYPE L COPPER (UNDERGROUND). TYPE M COPPER (ABOVE J
GROUND). PIPES COATED WITH ASPHALT. cm
FACE OF WALL. G) A/G CONDENSATE DRAIN - SCHEDULE 40 PVG. v co
D) PLUMBING FIXTURES - AMERICAN STANDARD, KOHLER, CRANE, OR EQUAL. i
STAINLESS STEEL COVER SCREWED
E) FLOOR AND ROOF DRAINS IF USED, J05AN OR EQUAL. c
TO THREADED G.O, PLUG M. F) ELECTRIC WATER HEATERS - GLASS LINED - 5 YEAR GUARANTEE - MORFLO OR �. " -
EQUAL. w
G) VALVES - 125 PSI - NIBGO, SCOTT, OR EQUAL. _
o
H) HOSE BIBS - GHIGAGO q52 OR EQUAL.
ca CL
"ZURN" #Z-1446-BP-VP FOR EXPOSED 7. PROVIDE ALL EXCAVATION, BACK FILL AND GOMPAGTION REQUIRED BY ALL PLUMBING
BLOCK AND GYPSUM BOARD WALL5.
"ZURN" #ZN-1447-BV
P- P FPR TILE WORK.
WALLS. "ZURN" #ZN-1448-5P-VP 8. PERFORM THE FOLLOWING TESTS:
FOR PLASTER WALL5. A) WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIC, PRESSURE TEST OF 100
P510 FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LE55 THAN
NALL
ONE HOUR.
B) DRAINAGE PIPING - BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF SYSTEM
SHALL BE GAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO N
STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. w
DRYER 4"d R STEEVE FOR G) WGORREGT ALL DEFECTS DISCLOSED BY ABOVE TESTS.
DUCT W/GAP. � z
"ZURN" q. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) TWO POUNDS OF CHLORINATED (--
# CONCRETE PAD "ZURN" #Z-1404-VPIRON BOX W/ LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN ® �/
LOOK 0-BP-T-VP 2x2 x8 W/ 4# GOVER MARKED G.O.
FLOOR GLEANOUT. I I MIXTURE IN PIPES 2 1/4 HORS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE w
3BW' PLAGIN6 IN SERVICE.
FIN. FLR. FIN. GRADE I I Q
FLUE I I 10. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE GIVEN AN IN-5ERVIGE TEST
AFTER COMPLETION OF THE INSTALLATION.
I I 11. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING
WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF
C) o
FILL VOIDS W/ OILED SAND, ONE YEAR FROM DATE OF FINAL AGGEPTANGE, AND THAT THEY WILL, AT THEIR EXPENSE G
SECTION VIEW COMPACTED FILL REPAIR AND REPLACE ALL WORK WHIGH BECOMES DEFECTIVE DURING GUARANTEE PERIOD. w
FOR CLARITY. LU 06 [-- C
ELEVATION VIEW GLEANOUT FITTING W/ BRA55 PLUG.
Lu `''
c
EXIST. EXIST. OC
FINISH WALL
OC v) m
FLOOR TO GRADE
TWO-WAY GLEANOUT TEE OR O
LONG SWEEP QUARTER BEND. ! cn
NOTE: REFER TO SPECIFICATIONS FOR MATERIALS EXISTING EXISTING W Q }
AND REQUIREMENTS FOR INSTALLATION. BEDROOM BEDROOM
DRYER VENTILATION THRU WALL x
GLEANOUT DETAILS N.T.5. N . T . S . W �
a
EX 15T I NG N .
BATH X
W
OEXI5TI N6
D ® WOOD DECK
EXISTING 3/4" GOLD I {
r HOT WATER LINE VERIFY
— —I—�II LOCATION 51ZE ,�, .4� a
X J '
"GUY GRAY" MODEL T-200 DRAIN BOX,
MOUNT 42 A.F.F. OR AS DIRECTED BY EXISTING X EXISTING ELECTRICAL
ARCHITECT, FLUME I NC-2 FIXTURE SGHEDULE BEDROOM W EXIST. EXI T. EXIST. E�15 T. RELOGAHTED R TO
EXISTING
SYMBOL FIXTURE TYPE SIZE C.W. H.W. DESCRIPTION X KITCHEN
w TOTAL=15FU
------------- P-1 WATER CLOSET 4" 1/2" - I/2" W
-------- - EXISTING 3 SANITARY
I LINE TO CONNECTED TO 2FU' I/ G 4FU
P-2 LAVATORY -I/2" 1/2 1/2 EXISTING SEPTIC TANK P-12
00 1 B NUM B ER
VERIFY LOCATION a 51ZE PFI 311 NEW
P-3 BATH TUB 2" I/2 1/2 w/ ANTI-SCALD VALVES O EXISTING ELECTRICAL NEW BAT LAUNDRY 00023
I PANEL TO REMAIN
I I
P-4 WHIRLPOOL 2" 1/2" 1/2" w/ ANTI-SCALD VALVES P-2 W/H -II
NOTE: DRAIN PIPING SHALL
L SLOPE NO LESS THAN 1/4" PER i a j P-5 SHOWER 2" I/2" I/2" w/ ANTI-SCALD VALVES EXIST. A/G COMP. 2 2
1F FU R E V I S 1 0 N S
FOOT. I I
I I P-6 BIDET 2" 1/2" 1/2" w/ VACUUM BREAKER
P-7 BAR SINK 1-1/2" 1/2" 1/2" EXISTING EXISTING EXISTING
R DINING ROOM LIVING ROOM FOYER
P-8 KITCHEN SINK 1-1/2 I/2
1/2" w/ GARBAGE DISPOSAL
UNION (TYP)
_ 1/211 DISCHARGE INTO GARBAGE X
2 DRAIN PIPE. P-9 DI5HWA5HER DISPOSAL UNIT.
El__ I I
I/2" NEW FAMILY "'P-10 SINK 2 - ROOM
P-11 LAUNDRY SINK 1_I/2 1/2" 1/2" F i L F
3" TRAP SEAL EXIST. EXIST. EXIST. EXIST. EXIST. 1ST.
P-12 WASHING MAGHI. 2" 1/2" 1/2"
P L o r 100%
REMOVEABLE TRAP P-13 REFRIGERATOR - - PROVIDE VALVE CONTROL EXISTING X D R A w N M
ENTRY w C H E C K E D M.C.
NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2" MIN
D A T E 07120/00
WASH N6 MAGH NE DRAIN BOX N.T.S. 2" $ LESS DIA DRAIN @ 1/4" DROP
3" 4 4" DIA DRAIN ® 1/8" DROP EXIST.
SHEET INDEX
PLUMB N G PLAN PLUMBING
1 PLAN
SCALE. /4 —� '—�' SHEET NUMBER
N
P-1
OF 1