00-0754-006
i NO. D,1TE REVISIONS POWER LEGEND NEW LOAD CENTER RATED VOLTAGE: 120/240V, 1PH, 3W LOCATION: HALL WAY 23 X24 U RELOCATED BREAKER SYMBOL DESCRImON _ ExisriNC --- RATED AMPS: 200 AMPS MOUNTING: FLUSH ti 25 RELUt'HTED METER TO BE RELOCATE DUPLEX RECEPT. (20A, +18"0.C. FROM A.F.F, U.N.D MAIN: MLO (CU BUSS) FEEDER CONDUCTERS: SEE RISER 1•° _---- -- -- BRANCH POLES: 40 FEEDER CONDUIT: SEE RISER D- z. JO JUNCTION BOX (04" GALVANIZED STEEL, U,N.D) INTERRUPTING RATE: 10 K A.I.C. MANUFACTURER CAT f. SQUARE-D QO DATA/TELEPHONE OUTLET (+18"O.C. A.F.F, U.N.D) BUS KVA DESCRIPTION -BRK WRE/ CIRCUIT rVIRf/ DESCRIPTION BUS KVA �� _ _ - BRK _ _ i- _ HATCH AREA INDICATES PHONE _T - - -' -- _ A B TRP/PL.S COND. NUMBERS', CON_D. TRP/PLS" A B j (� ELECTRICAL DISCONNECT (+60 O.C. A.F.F, U.N.D) / / N NEMA 3R FOR EXTERIOR AND NEMA 1 FOR INTERIOR, 2.2 A/C 30/2 X10/1/2 1 2 X6/3/4' 4.3 �--- PANELBOARD (+60 A.F.F O.0 OF PNL, U.N.D) 2.2 3 4 60/2 A/C 4.3 12/1/2' 5 6 #'12/1/2 20/1 LTG, & REC. 0.6 0.6 LTG. Sc REC. 20/1 .,� - -_- ELECTRICAL METER (+60" A.F.F O.0 OF VTR, U.N.D) 0,6 LTG. & REC. 2011 ,#12/1/2' 7 8 /12/1/2'. 20/1 LTG. & REC. 0.6 NEW 1------ , �i PHASE 0.6 LTG. & REC. 20/1 X12/1/2' 9 10 X12/1/2' 20/1 LTG. & REC. 0.6 PANEL - - -' - 17� I 24' ISOLATED GROUND 0.6 LTG. & REC. 20/1 #12/1/2' 11 12 /12/1/2' 20/1 LTG. & REC. 0.6 0 E GFINEUTRAL 0.6 LTG. & REC. 20/1 #'12/1/2' 13 14 ',#12/1/2'. 20/1 LTG. & REC. � 0.6 � RTu=1 � � ®26/28 3 45A-- - FUSE SIZE 2.3 - DISCONNECT 15 18 1,�12/1/2� 20/1 LTG. & REC. 0.6 ', D;sctxvNECT "E+"A-� (1000 CF!�) 60A-_-- - 'Mi. N. 30/2 #10/1/2' FRAME SIZE 2.3 17 18 },#12/1/2 20/1 LTG & REC. 0.6 �. - " --_ - NUMBER OF POLES 0.6 LTG. & REC. 20/1 ,#12/1/2- 19 20 /12/1/2' 20/1 LTG. & REC. 0 6 ROOF TOP 4� 0.6 LTG. & REC. 2011 .#_12/1/2' 21 22 1,#12/1/2' 20/1 LTG. & REC. 0.6 TUSE 11 CU FIRE ALARM LEGEND 0,6 RECEPTACLE 20/ 1121112"1 23 24 #121112" 20/1 RECEPTACLE 0.6 DISCONNECT I TO PANEL 1 SYMBOL DESCRIPTION 0.6 LIGHT 20/1 #12/1/2' 25 26 RTU -1 2.6 - 0.2 ROOF GFi 20%1 12/1/2" 27 28 J6/i. 30/2 (2.5 TON, 5KN HEAT) 2.6 1/2 .CHASE - E.O.L.R. END OF LINE RESISTOR 29 HEATHER PROOF X23 © SMOKE DETECTOR 31 32 Box AND COVER 96 ae 96 dbj DUAL ACTION 33 34 : GAI RECEPTACLE A/H 25 . 25 MANUAL PULL STATION (+48" A.F.F, U.N.D) , ; t) 23 24d ` -- - EXIST STROBE LIGHT,(+80' AF.F, U.N.D) (75 cd) 37 38 + --- - - --- --- - - THREE-PULSE TEMPORAL HORN 'N/ 39 40 STROBE LIGHT,(+80' AF.F, U.N.D) (75 cd & 96db). 8 7 TOTAL TOTAL 10 10 FRCP._- ---FIRE ALARM CONTROL PANEL TOTAL BUS KVA A: 8 + 10 = 18 �.. B: 7 + 10 = 17 it N 1 NEW ( # DENOTES QUANTITY) TOTAL CONNECTED KVA 35 148 AMPS EXISTING - - - FIRE ALARM SYSTEM RESPONSE ROOF RECEPTACLE LE DL' TAIL FACP •y,E 140T 10 SCALE - - - FIRE ALARM SYSTEM INITIATION I _._....__ r.. ._, _1_,..,.,>. ,_,.�_-- ,_�.:- -- ,- --- , EXTERIOR HALLWAY V1 LIGHT f� IX I RE LEGEND I 1 EP PULE SYMBOL DESCRIPTION E-1 PRISMATIC LENS LAY-IN LIGHT FIXTURE ROOF 3 LAMP, T-8 W/ ELECTRONIC BALLAST. LSI MIDWEST MD L# LA-332-SO-SSO OR EQUAL E CEILING M11). EXIT SIGN 'N/ BATTERY BACK UP z © (+96 A.F.F MAX, U.N.D) PROVIDE FULL SIZE PRESCOLITE MDL;#-XT3REN'WH -1201277 OR EQUAL GROUND WiRE TO FULL SIZE COPPER ►- SIGN - 3-#110 CU., CABLE TO HATCH AREA INDICAiES FACE OF S - IG THWN. IN 1 112- EMT WA1ER PIPING AND WALL MOUNTED EXIT SiGN 'W/ BATTERY BACK-UP FOOTER STEEL SERVICE GEAR OC V6' ABOVE DOOR TO CENTER OF SIGN, U.N.D) RE + LOCATED RELOCATED t r� 200A CIRCUIT !_ RESCOUTE MDL XT3REN'WH -120127-7 OR EQUAL / BREAKER NEW ! // PROVIDE FULL SIZE �� ELECIRICAL LIGHT SWITCH (+48" A.F.F, U.N.D) f LOAD CTR. CLAMP ON FITTI NG - �� COPPER CABLE BETWEEN i .ALAN'NATER X ALL GROUND RODS LIADNDrOBUILD�NG STEEL � $3 3 W METER PIPE AY LIGHT SWITCH (+48' A.F.F, U.N.D) 150 - CLAMP ON FITTING NOTE: 1. CONNECT AHEAD OF S'WiTCH. SCALE: 1/4 =1'-O" _ lOK Al 2 POLE SWITCH (+48" A.F.F, U.N,D) NEMA 3R NEMA 1 /�6 SOLID COPER _ 0 T.T.B. DIMMER SWITCH (+48' A.F.F, U.N.D) 3-#110 CU., - C`1J EXHAUST FAN (SEE MECHANICAL PLANS FOR SPECS) THWN. IN 2" RGS. COLD 'WATER PIPE COPPER CLAD _ x GROUND ELECTRODE VERIFY EXACT LOCATION ® CEILING MiD. DUPLEX IN FIELD. ROD TO BE NOT LESS - _ _ THAN 3/4"x 10' LONG AREA OF WORK NOTES 6'-0" MINIMUM 1. NOT ALL SYMBOLS MAY APPEAR ON PLANS F.F. I - 2, IF THERE IS NO DESIGNATION NEXT TO FIXTURE, THEN ASSUME IT iS A NEW FIXTURE. IF NOT EXISTING, LOCATE # 6 GND. IT AS SHOWN ON PLANS _ -- DESIGNATION / DESCRIPTION - - - (SEE DETAIL) +84' DENOTES HEIGHT ABOVE UN UNLESS NOTED DPI-RENTLY FINISHED BOOR T/S TiME SrMTCH ELEC r RICAL RISER `I GROUNDING ,r GFI GROUND FAULT CIRCUIT INTERRUPT PC PHOTO CELL n�j HP RATHER PROOF ENCLOSURE LC LIGHTING CONTACTOR O D L L/ 1 ��I L iG ISOLATED GROUND i4 WC MiNIVUM WORK CLEARANCE NOT TO SCALE NOT TO SCALE NA. NIGHT LIGHT OCP OVER CURRENT PRO TE C TiON R RELOCATED FIXTURE OC ON CENTER E INDICATES AN EXISTING FIXTURE TO REMAIN i i - _ - -_ KE"Y'r PLAN ELLL I RILAL SPELII� I CA 1 IONS _» , _ Y _ _ _ _ _ -_ • NOT TO SCALE 1. MATERIALS AND INSTALLATION, AS A MINIMUM, ARE TO CONFORM WITH THE LATEST EDITION 14. ALL FUSES FOR SAFETY SWITCHES SHALL BE DUAL ELEMENT, CARTRIDGE TYPE, FUSES SHALL BE 25. ALL UNDERGROUND PVC CONDUIT RUNS SHALL HAVE RIGID STEEL ELBOWS AND RIGID STEEL1 OF THE NATIONAL ELECTRIC CODE, N.F.P.A., LOCAL CODES, ORDINANCES, INCLUDING ALL THOSE MANUFACTURED BY EITHER BUSSMAN OR LITTLEFUSE. THE CONTRACTOR SHALL FURNISH SECTIONS AT SLAB PENETRATIONS 'WHERE SUBJECT TO POSSIBLE DAMAGE. WHERE RIGID STEEL r AMENDMENTS TO THE N.E.C. EQUIPMENT, 'WHERE APPLICABLE, WiLL BE USTED WITH THE TO THE OWNER ONE SPARE FUSE FOR EACH SIZE AND TYPE OF FUSE INSTALLED, FUSES 600 AMPS IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKALI AND RUST-RESISTANT BITUVAS71C yy� UNDERWRITERS LABORATORIES, INC, QUALITY AND WORKMANSHIP ESTABLISHED BY DRAWINGS AND OR LESS SHALL BE CLASS RK1, TYPICAL UNLESS OTHERWISE NOTED, FUSES OVER 600 AMPS SHALL PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED MTH ZINC CHROMATE. �ar�lJ V SPECIFICATIONS ARE NOT TO BE REDUCED BY THE ABOVE MENTIONED CODES. BE CLASS L. V 26. THE ELECTRICAL CONTRACTOR SHALL MEET AND COORDINATE WiTH THE LOCAL POWER COMPANY 2. BIDDERS ARE TO VISIT THE SITE AND FAMILIARIZE THEMSELVES WITH EXISTING CONDITIONS AND 15, ALL GENERAL PURPOSE S'MTCHES AND RECEPTACLES SHALL BE THE PRODUCT OF A SINGLE AT THE SITE PRIOR TO CONSTRUCTION. AT THAT TiME, THE CONTRACTOR SHALL COORDINATE _ _ _ _ _ _ SATISFY THEMSELVES AS TO THE NATURE AND SCOPE OF WORK. THE SUBMISSION OF A BID WILL MANUFACTURER. CATALOG NUMBERS USTED ARE LEVITON: HOWEVER, COMPARABLE DEVICES BY ALL RELATED ';YORK 'WITH ME UTILITY COMPANYS RESPONSIBILITIES TO MEET THE OWNER'S - BE EVIDENCE THAT SUCH AN EXAMINATION HAS BEEN MADE. LATER CLAIMS FOR LABOR, EQUIPMENT, PASS & SEYMOUR, BRYANT, 4R ARROW HART 'HILL BE ACCEPTED, COLOR OF DEVICES AND SCHEDULE. OR MATERIALS REQUIRED, OR FOR DIFFICULTIES ENCOUNTERED WHICH COULD HAVE BEEN FORESEEN PLATES SHALL BE DICTATED BY ARCHITECT/OWNER. HAD AN EXAMINATION BEEN MADE, WILL NOT BE ALLOWED. A. SWITCHES: LEVITON S81-201 27, ALL ELECTRICAL CONDUCTORS SHALL BE INSTALLED IN AN APPROVED RACEWAY, EMT, iMC, RIGID - GALVANIZED CONDUIT OR SCHEDULE 40 P.V.C. THERE SHALL BE NO TYPE 'NM', 'MC', ELECTRICAL 1---- 3. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR IN A FIRST-CLASS B. RECEPTACLES; LEATON #BR20-1 NON-METALLIC TUBING, & FLEXIBLE METAL CONDUIT USED FOR BRANCH CIRCUITING. MAXIMUM • ^ �T WORKMANLIKE MANNER. THE COMPLETED SYSTEM IS TO BE FULLY OPERABLE AND ACCEPTANCE OF C. COVER PLATES: SMOOTH PLASTIC NUMBER OF 120V CIRCUITS ALLOWED iN A COMMON CONDUIT SHALL BE SIX (6). THE THIS SYSTEM BY THE ENGINEER MUST BE A CONDITION OF THE SUB CONTRACT. EXISTING A CONTRACTOR SHALL STRICTLY CONFORM TO THE N.E.C. REQUIREMENTS OF GERATING FOR NOTE: ALL OTHER REQUIRED DEVICES SHALL MATCH IN COLOR AND STYLE. BUILDING �j r 4. ALL WORK TO BE COORDINATED ' TH OTHER TRADES TO AVOID INTERFERENCE WITH THE CONDUCTOR AMPACiTY AND CONDUIT FILL. PROGRESS OF CONSTRUCTION. 16. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL OF CONSTRUCTION. THE FACP CONTRACTOR IS EXPECTED TO FURNISH AND INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL 28. CONDUCTORS SHALL BE COLOR CODED AS FOLLONS: 5. CONTRACTOR TO GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE FROM DEFECTS FOR PERIOD SYSTEM, AND PROVIDE ALL NECESSARY DEVICES AND COMPONENTS FOR EQUIPMENT BE PLACED IN 208V SYSTEM LN OF NOT LESS THAN ONE (1) YEAR FROM DATE OF ACCEPTANCE. PROPER 'WORKING ORDER. NEUTRAL - 'WHITE N V ~ NOTES: 6, CORRECTION OF ANY DEFECTS TO BE COMPLETED WilHOUT ADDITIONAL CHARGE AND TO INCLUDE 17. A SEPARATE, GREEN TYPE 1HYM1 COPPER GROUND CONDUCTOR SHALL BE RUN FROM GROUND LUG OF PHASE A - BLACK PHASE B - RED REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION 'WHICH MAY HAVE BEEN EACH GROUNDED RECEPTACLE TO AN APPROVED CONNECTION INSIDE THE ENCLOSING STEEL OUTLET 1. WIRE USED IS 18 GAUGE FPL OR TFN WHERE REQUIRED FOR INITIATING `r - DAMAGED THEREBY. GRD.CGN - GREEN , BOX. DEVICE MOUNTING SCREWS SHALL NOT BE CONSIDERED AN APPROVED GROUND. CIRCUIT, 16 GAUGE FOR SIGNALING CIRCUIT. 7. ALL REQUIRED INSURANCE TO BE PROVIDED FOR PROTECTION AGAINST PUBLIC LIABILITY OF A SEPARATE GROUND CONDUCTOR SHALL BE INSTALLED IN EVERY CONDUIT AND RACEWAY AND 2. ALL COMPONENTS ARE UL LISTED FOR PURPOSE INTENDED, v N . PROPERTY DAMAGE FOR ME DURATION OF THE 'WORK. - N• THE 29 FIRE RATED CONTRACTOR SHALL CBEEL N RESPONSIBLE B ETC SEALING PENETRATION CONDUIT SE PENETRATIONS MADE THROUGH 3, FIRE ALARM CONTROL PANEL SHALL BE CROSS LISTED AllH OTHER SECURELY BONDED IN AN APPROVED GROUNDING TERMINAL AT BOTH ENDS OF THE RU LL BE PER U.L. ASSEMBLY 3. CONTRACTOR TO PAY FOR ALL PERMITS, FEES INSPECTIONS AND TESIINGS. GROUNDING CONDUCTOR SHALL BE SIZED IN ACCORDANCE WITH TABLE 250-95 OF THE N.E.C. COMPONENTS USED. 'n CONTRACTOR SHALL SIZE CONDUIT TO ACCOMMODATE ADDITIONAL CONDUCTOR. STANDARDS. 9. ELECTRiCAL INSTALLATION TO MEET ALL STANDARD REQUIREMENTS OF LOCAL POWER AND 4. THE SOUND LEVEL WILL BE AT LEAST 15 DBA ABOVE THE EQUIVALENT SOUND 18. LOAD DATA IS BASED ON INFORMATION GIVEN TO THE ENGINEER AT THE TiME OF DESIGN. 30. CONTRACTOR SHALL MAINTAIN A COMPLETE SET OF CONTRACT DRAWINGS AT JOB SITE MM LEVEL OR 5 DBA ABOVE THE MAXIMUM SOUND LEVEL HAVING A DURATION TELEPHONE COMPANIES. ELECTRICAL CONTRACTOR SHALL CONTACT LOCAL POWER AND COLORED MARKINGS INDICATING PROGRESS OF 'WORK. THIS SET OF CONTRACT DRAWINGS IS TO TELEPHONE COMPANIES PRIOR TO START OF CONSTRUCTION. VERIFY ALL EQUIPMENT NAMEPLATE RATINGS BEFORE ORDERING. OF AT LEAST 60 SECONDS MEASURED 5 FEET ABOVE THE FLOOR IN THE BE SEPARATE FROM AND IN ADDITION TO CONTRACTOR'S CONSTRUCTION SET. EVERY UNIT OF OCCUPIED AREA, INCLUDING LOUNGE, 'WALK IN COOLERS AND STORAGE AREAS. 10 ALL MR;NG SHALL BE iN CONDUIT UNLESS OTHERWSE NOTED MINIMUM 'WIRE SIZE SHALL 19, CIRCUITS SHOWN ON PLANS ARE TO DETERMINE LOAD DATA AND PANEL SIZES. THE CONTRACTOR EQUIPMENT, DEVICE, CONDUIT AND 'WIRE IS TO MARKED WHEN INSTALLED, USE GREEN TO THE CONTRACTOR WiLL BE REQUIRED TO CERTIFY THE DBA LEVEL 'WITH AN APPROVED BE #12 A'WG, EXCLUDING CONTROL 'WIRING. ALL CONDUCTORS SHALL BE COPPER WiTH IS TO PROVIDE CIRCUITS AND ROUiiNG OF CONDUITS TO SUIT JOB CONDITIONS. INDICATE INSTALLATION AS SHOWN ON DRAWINGS AND USE RQ TO INDICATE FiELD CHANGES. DBA METER PRIOR TO THE ISSUANCE OF THE CERTIFICATE OF OCCUPANCY. � � � �� TH'YvN/TNHN INSULATION. CONDUCTORS X10 AND SMALLER MAY BE SOLID; ALL THOSE 8 UPON COMPLETION OF WORK, THIS SET OF CONTRACT DRAWINGS IS TO BE TURNED OVER TO, DESIGNED BY: ES I EI OL ;. 20. FURNISH AND INSTALL DISCONNECT SWITCHES, �ViRING, AND CONNECTIONS ON AIR CONDITIONING AND BECOME PROPERTY OF THE ELECTRICAL ENGINEER AND LARGER TO BE STRANDED. 5. CONTRACTOR SHALL SUBMIT WiTH PERMIT SET, SHOP DRAMNGS, SYSTEM AS SHOWN ON PLANS. ELECTRICAL CONTRACTOR SHALL VERIFY AND COORDINATE 'Wi1H FIRE ALARM RISER, BATTERY CALC'S & CUTShEETS ON ALL EQUIPMENT. I �- _- •� � ��"• "- ' CERTIFIED BY:ES�I�E>vO'1. 11, ALL UNDERGROUND RACEWAYS SHALL BE MINIMUM 3/4', GALVANIZED RIGID STEEL CONDUIT OR MECHANICAL CONTRACTOR REGARDING SUPPLY AND INSTALLATION OF ALL REQUIRED CONTROLS. 31, IF ELECTRICAL CONTRACTOR HAS QUESTIONS, OR IN TTIEIR OPINION FINDS OMISSIONS OR _ SCHEDULE 40 PVC. ALL OTHER RACEWAYS TO COMPLY 'WITH GOVERNING CODES. WERE RIGID STEEL ERRORS ON ELECTRICAL DOCUMENTS, IT IS THEIR RESPONSIBILITY TO BRING THIS TO THE - - 21. ALL FLUORESCENT LIGHT FIXTURES SHALL HAVE IN LINE FUSING AND ENERGY SAV1NG BALLASTS. 6. CONTRACTOR SHALL HAVE A CERTIFICATE OF COMPLETION FOR EACH FIRE IS USED, IT SHALL BE COMPLETELY COATED WITH AN ALKAU AND RUST RESISTANT BITUMASTiC ATTENTION OF THE ELECTRICAL ENGINEER IMMEDIATELY. IF ELECTRICAL CONTRACTOR PROCEEDS _ _ DXfE: 04/02/0I PAINT, COPPER NO. 50, AND THREADS SHALL BE COATED WITH ZINC CHROMATE. RIGID STEEL WITH ANY CHANGES TO THE CONTRACT DOCUMENTS, `MTHOUT WRITTEN PRIOR APPROVAL FROM ALARM SYSTEM INSTALLED AND SHALL PROVIDE A COPY TO THE OWNER AND - - USED A`HEN CONDUIT IS EXPOSED TO EXTERIOR ENVIRONMENT SUCH AS EXTERIOR 22• ALL S',MTCHGEAR, PANELS, STARTERS, CONTACTORS ETC , SHALL BE THE PRODUCT OF A SINGLE THE ELECTRICAL ENGINEER, CONTRACTOR WILL NOT BE COMPENSATED. THE FIRE RESCUE DEPARTMENT. � -- - - SHALL ALSO 8E y VANUFACTURER, THE SYSTEM DESIGN IS BASED ON SQUARE 0 , HOWEVER, COMPARABLE EQUIPMENT PROJECT sn: 1091 OF BUILDING OR '*4ERE IT IS EXPOSED AND SUBJECT TO DAMAGE, iNSiDE OF BUILDING. & SIEMENS ONLY WILL BE ACCEPTABLE. TANDEM AND HALF-SPACE CIRCUIT BREAKERS 7. SEE PLANS FOR EXACT NUMBER OF DEVICES ,,s4�Offt ' , 5 A FS BY G.E. ---- _ 12. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, CAST ALLOY WITH THREADED HUBS SHALL NOT BE USED. F. -1FIC ' T� DRAWING NO, IN NET OR DAMP LOCATIONS, AND BE OF SPECIAL CONSTRUCTION FOR OTHER GLASStFIED AREAS. A 2 FIRE �` :0 ,ALL BOXES SHALL BE RECESSED (FLUSH) IN HALLS OR CEILINGS WHENEVER POSSIBLE. 23. T-TPEARiTTEN CIRCUIT INDEX SHALL BE AFFIXED TO INSIDE SURFACE OF EACH PANELBOARD I',I��L` ALAI�I�i IZISLIZ DI��(JIZAII�I ` No. =r' DOOR, CLEARLY INDICATING AREA AND TYPE OF LOAD SERVED BY EACH BRANCH CIRCUIT ___ _____ __________________- ______-___ _ PROTECTIVE DEVICE, INCLUDING SPARES. HAND PRINTED '�MLL NOT BE ACCEPTED. N.T.S. STATE OF -t 13. DISCONNECT SNATCHES SHALL BE H.P. RATED, GENERAL DUTY, QUICK-MAKE, QUICK-BREAK TYPE. ENCLOSURES SHALL BE AS REQUIRED BY N.E.C. AND LOCATION (`WEATHERPROOF, EXPLOSION2or�o 24. ENGRAVED, LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND INSTALLED PROOF, ETC,). ENGRAVED LAMINATED PLASTIC IDENTIFICATION PLATES SHALL BE FURNISHED AND ��- INSTALLED ON ALL DISCONNECT SNITCHES, CONTACTORS AND STARTERS. ON ALL PANELS AND S'MTCHGEAR. PLATES SHALL BE AFFIXED TO FRONT OF PANELS, iNDICATiNG p� I • r� PANEL NAME, VOLTAGE AND AMPERAGE. A �,