PROVIDE 3/8' DIAMETER THREADED R00 WITH PLUMBING SHEET INDEX I� WASHERS AND DOUBLE NUTS AT �
EACH END. ROUTE ROD FROM CHANNEL BELOW WATER HEATER UP TO FASTENERS ABOVE. (TYPICAL OF 4) ARCHITECTS
POA PLUMBING NOTES, LEGEND, DETAILS do ISO'S O
3/8' HILTY INSERT HDI-3/8'. (TYPICAL CF 4) ARCHITECTS/PLANNERS
t0 1� P2.1 SAN. do DOLT. WATER PLAN Q .V
N£Ct BAR JOIST STRUCTURAL SUPPORT SYSTEM.- 0
Y
0
ML
N
zyz //Fni-1 Yl Vn // PLUMBING NOTES o
OF
COLD WATER SUPPLY �
NE CT t0 .01 I TO WATER HEATER 1. ALL WORKMANSHIP AND MATERIALS SHALL BE IN STRICT ACCORDANCE WITH APPUCA13LE CORPORATE Offlm
CONnNG 0 i I HEAT TRAP LOCAL CODES, RULES AND ORDINANCES. 949 am MOORf RQAD •�
EXjS Y i 2• ANNE t i �2 (OMIT IF HEAT TRAP IS AN 2. HIbISELF WITH ALL CONTRACTOR J08 �� AND THOROUGHLY FAMILIARIZE BOU BATON,R. 33487 a
C STIN I INTEGRAL PART OF HEATER). Plane (561) 997.9997
3. ALL MATERIALS SHALL BE NEW. O
HOT WATER TO FIXTURES I 4. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR IN A FIRST Fax ��� �-��
AS SHOWN ON PLANS. CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM SHALL BE FULLY OPERATIVE. ALL ORLANDO Offl(M C:
STING /NE O EXCAVATION AND BACKFILL AS REQUIRED FOR THIS PHASE OF CONSTRUCTION SHALL BE ,303 FERNUM AVE#C v�
4 PROVIDE FULL PORT BALL ' A PART OF THIS CONTRACT. ORLANDO 328Q3 c0
�va ITAP � I 2 SHUT-OFF VALVES. � PROVIDE A 2107 5. REQUIRED INSURANCE SHALL BE PROVIDED BY THE PLUMBING CONTRACTOR FOR PROTECTION
.100 TEMPERATURE AND AGAINST PUBLIC LIABILITY AND PROPERTY DAMAGE FOR THE DURATION OF THE WORK. Pt"* (407) 843-9997 V
PROVIDE PIPE CT t0 / I 2, UNIONS, DIELECTRIC 150 PSI PRESSURE 6. PLUMBING CONTRACTOR SHALL SECURE AND PAY FOR ALL PERMIT'S, FEES, INSPECTION AND Fax (407) 843'722$
CONING � IF REQUIRED FOR RELIEF VALVE TESTS, PLUMBING CONTRACTOR TO OBTAIN PERMIT AND APPROVED SUBMITTALS PRIOR TO
EO i 3' I DISSIMILAR METALS. WITH TEST LEVER BEGINNING WORK OR ORDERING EQUIPMENT. PLUMBING CONTRACTOR MUST BE PRESENT FOR www '
SIZED WITH AGA/CGA ALL INSPECTIONS OF HIS WORK BY REGULATORY AUTHORITIES. 3
Y I TEMPERATURE STEAM 7. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE FOR THE EXACT LOCATION OF FIXTURES,
3' DRAIN VALVE BY EQUIPMENT, ETC.
3� I RATING 10� OVER PIPING,
30 �, HEATER MAUFACT. O
HEATING INPUT. 8. ALL WORK SHALL BE COORDINATED MATH OTHER TRADES TO AVOID INTERFERENCE NTH �
THERMOSTAT AND THE PROGRESS OF CONSTRUCTION. REPORT ANY DISCREPANCY TO ENGINEER/ARCHITECT x
PRESSURE REGU- PRIOR TO BEGINNING CONSTRUCTION. O
, PROVIDE A HARD 9. VERIFY LOCATION. SIZE, DIRECTION OF FLOW AND INVERTS OF ALL EXISTING UTILITIES
TRAP �1�2 LATOR FURNISHED r- COPPER RELIEF PRIOR TO BEGINNING OF CONSTRUCTION. ADVISE ENGINEER OF ANY DISCREPANCIES.
1 NTH WATER HEATER.
1�2 R VALVE DISCHARGE 10. WATER DISTRIBUTION PIPING ABOVE k BELOW GROUND TO BE TYPE 'L' COPPER. W (n �
PRIM E 3 4' PLYNI000 BELOW - - - LINE FULL SIZE OF COORDINATE WITH LOCAL JURISDICTION FOR ADDITIONAL REQUIREMENTS.
/ -- VALVE OUTLET TO PROVIDE ALTERNATE FOR CPVC PIPING EQUAL TO BFGOODRICH 'FLOWGUARD GOLD' FOR WATER .W
WATER HEATER DRAIN �. RUN TO TIE INTO KNOWN OR DETERMINED TO HAVE ACIDIC CHARACTERISTICS. CONTRACTOR SHALL PERFORM A
PAN AS PLATFORM. __ EXISTING. SEE FLOOR PLAN WATER TEST TO DETERMINE WATER CHEMISTRY PRIOR TO ANY WORK OR PIPING INSTALLATION W
AND SHALL SUBMIT TEST RESULTS TO ENGINEER FOR REVIEW AND APPROVAL D.. 3
2' DEEP SAFEPAN. 11. SOIL, WASTE VENT AND RAINWATER PIPING SHALL BE CAST IRON OR PVC WHERE CODE ALLOWS. �! �
SANITARY ISOMETRIC 1 PVC MAY NOT BE USED THRU RATED ASSEMBLIES OR IN PLENUMS. W
NOT TO SCALE PROVIDE A DRAIN 12. ALL FIXTURES MUST BE PROVIDED NATH READILY ACCESSIBLE STOPS AND APPROPRIATELY V) O
PAN, RUN OVERFLOW PROVIDE 2' CHANNELS MARKED ACCESS PANELS. COORDINATE LOCATIONS WITH GENERAL CONTRACTOR PRIOR Z N
LINE TO TIE INTO WITH MINIMUM 2 COATS TO INSTALLATION. v
OF RUSTPROOF PRIMER 13. FURNISH AND INSTALL APPROVED AIR CHAMBERS, AT EACH PLUMBING FIXTURE AND
EXISTING. SEE FLOOR SPANNONG BETWEEN APPROVED SHOCK ARRESTORS ON MAIN LINES OR RISERS. 3:
PLAN THREADED RODS TO 14. DIELECTRIC COUPLINGS ARE REQUIRED BET1W£EN ALL DISSIMILAR METAL IN PIPING AND E
WATER HEATER - MAXIMUM SUPPORT WATER HEATER EQUIPMENT CONNECTIONS. ~ f"' `-
OF 30 GALLON CAPACITY. SAFEPAN. 15. ISOLATE COPPER PIPE FROM HANGER OR SUPPORTS WITH ISOLATOR PADS OR MATERIAL V) O
w
PIPING ARRANGEMENT SHOWN IS SCHEMATIC. ADJUST TO SUIT 16. ALL FIRE RATED FLOOR AND WALL PENETRATIONS SHALL BE PROPERLY PROTECTED FROM N W >%
FIRE, SMOKE AND WATER PENETRATION BY FILLING VOIDS BETWEEN PIPE AND WALL/FLOOR � t v
1 c
FIELD CONDITIONS. REFER TO ISOMETRIC RISER FOR PIPE SIZES.
SET HEATER THERMOSTAT AT 120 7. SLEEVES WITH FIRE RATED FOAM, TO ACHIEVE THE SAME RATING AS WALLS OR FLOORS U
AS PART OF THE PLUMBER'S WORK. O O ,C
G 000
17. PLUMBING CONTRACTOR
FOR PERIOD OF NO GUARANTEE ALL M
LESS THAN ONE ( ) YEAR FROMDATE OF ACCEPTANCE BY N
E)050 ONE /� �j ( ( �LJ�( (�(C� (� Q '(���j A OWNER. CORRECTION OF ANY DEFECTS SHALL BE COMPLETED WITHOUT ADDITIONAL CHARGE 'Q
�A1ER WATER':'
/rV U L�U ll U U L� L�I�1 U\'��OQV U V 1 I ®� i�U L AND SHALL INCLUDE REPLACEMENT OR REPAIR OF ANY OTHER PHASE OF THE INSTALLATION v
Ct TO AIR CND BER NO SCALE WtiNICH MAY HAVE BEEN DAMAGED. 0
,.�. 18. PROVIDE ACCESS PANELS FOR ALL CONCEALED VALVES AND ALL WATER HAMMER
GO►SnNG 2' ( I ARRESTORS. ACCESS PANELS IN RATED WALLS MUST MAINTAIN THE SAME RATING AND
E i MUST MATCH THE FINISH OF THE WALL IN WHICH IT IS INSTALLED. v
;r • .. 19. PROVIDE CHROME PLATED COMBINATION COVER PLATE AND CLEANOUT PLUG OR ACCESS v
110, 4 PLUMBING LEGEND PANEL FOR ALL WALL CLEANOUTS. 0
20.NO COMBUSTIBLE MATERIAL TO BE USED IN MECHANICAL ROOMS OR IN CEILING SPACES Florida License a
`'• / 3�4 1�2 WHERE USED AS RETURN AIR PLENUMS. AAC002193
I I 21. NO WATER, SANITARY OR DRAINAGE PIPING PERMITTED IN ELECTRICAL OR ELEVATOR IBOOOI142
' CO CLEAN OUT S-----5 SANITARY SEWER PIPING EQUIPMENT ROOMS. v
22.ALL CONTROL VALVES SHALL BE TAGGED AND MARKED. A REPRODUCIBLE DIAGRAM
FD FLOOR DRAIN - - - VENT PIPING LOCATING ALL VALVES SHALL BE PROVIDED FOR OWNER/OPERATOR. T
23.ALL CONDENSATE DRAIN PIPING SHALL BE TYPE 'L' COPPER WITH 1' THICK
CW DOMESTIC COLD WATER 5-----S DOMESTIC COLD WATER PIPING ARMAFLEX INSULATION WHERE USED IN A RETURN AIR PLENUM. PVC PIPING WITH 1' THICK
I ARMAFLEX INSULATION MAY BE USED IN LOCATIONS WHERE ALLOWED BY LOCAL CODES. c
HW DOMESTIC HOT WATER --- --; HOT WATER PIPING (110') SEE PLUMBING DRAWINGS FOR SIZE AND LOCATION OF PIPING.
24.PROVIDE ANGLE STOPS ON ALL WATER SERVICE LINES TO FIXTURES FOR INDIVIDUAL
�Q GATE VALVE �•�--Td�f'-; TEMPERATURE AND PRESSURE RELIEF SHUT-OFF.
112 25.WATER PIPING INSULATION SHALL BE i' THICK ARMAFLEX INSTALLED IN ACCORDANCE
O FD FLOOR DRAIN S-•. rDF'-; SAFEPAN DRAIN PIPING WITH MANUFACTURERS INSTRUCTIONS FOR ALL HOT WATER PIPING. WHERE DOMESTIC
l/ WATER TEMPERATURES CAN CAUSE SWEATING ALL COLD WATER PIPING SHALL BE Job No. 6186.12
0
S_ 5 PIPE RISE OR DROP INSULATED WITH 1/2' THICK ARMAFLEX INSULATION. (1
26.STUDOR MINI/MAXI AIR ADMITTANCE VALVES MAY BE USED AS AN ALTERNATE TO o
S-?-S PIPE RISER UP VENT PIPING THRU ROOF WHERE ACCEPTABLE BY THE PLUMBING OFFICIAL AND LOCAL Designed By.
CODES. INSTALLATION SHALL BE AS PER MANUFACTURER'S RECOMMENDATION!;- Drawn By. TJD a'
CAPPED END OF PIPE
Checked By. SM a
(` }-- POINT OF CONNECTION HANDICAP LAVATORY, AMERICAN STANDARD, DECLYN WALL HUNG LAVATORY MODEL CAD File Name:
HLAV 110321.075. WHITE, WITH FAUCET AMERICAN STANDARD MODEL 12000.101. CONTRACTOR v
P-TRAP TO SUPPLY CONCEALED ARM SUPPORT CARRIER FOR MOUNTING OF LAVATORY. SUPPLY N
TRUBRO MODEL J102G HANDI LAV-GUARD INSULATION KIT. MUST MEET A.D.A. CODE.
DOMESTIC WATER ISOMETRIC HANDICAP WATER CLOSET AMERICAN STANDARD 2168.100 FLOOR MOUNTED WHITE, SEAT o
NOT TO SCALE HWC CCSONITE 195 OPEN FRONT SEAT WITH COVER. ADA EL 1.6 ELONGATED 18 HIGH OR
PROVIDE TEST TEE T EQUAL. i
WITH SCREWED COUNTER- COLUMN OR PARTITION v
SUNK ABS PLASTIC PLUG: AS SHOWN ON FLOOR PLAN Q'
TAPERED-THREAD WITH i Z"_CLEANOUT FACE SHALL FD FLOOR DRAIN, 3' PVC WITH 4' DEEP SEAL TRAP. REVISIONS O
PROVIDE AN INDIVIDUAL VENT ON ALL FLOOR DRAINS. INSTALL VENT TFE JOINT COMPOUND. i -•- BE WITHIN 4' OF WALL Z
IN PARTITION OR CHASE WHERE SHOWN ON PLAN. HORIZONTAL VENT _�
BELOW FLOOR IS NOT PERMITTED.OTHER VENTING METHODS MAYBE USED SURFACE. PROVIDE SINGLE STAINLESS STEEL SINK, 25X22 DAYTON MODEL #X-12522 WITH CHICAGO
IF APPROVED BY LOCAL CODE. WHERE CLEANOUT TEE = PIPE EXTENSION IF REQUIRED. SK
IS CONCEALED IN A FAUCETS MODEL f786E3-CP KITCHEN 5-3/4' SPREAD GOOSENECK WITH 4' WRIST
CHASE OR PARTITION, BLADE FAUCET HANDLES. �-
CONCRETE FLOOR PROVIDE A ROUND 18 i i uvi
"•. i i O
. .. . : .: GAUGE STAINLESS STEEL i i
COVER WITH BEVELED PLU�iIBIN� MIXTURE SCHEDULE
MEMBRANE CLAMP- EDGES AND FLATHEAD
ING COLLAR AND MACHINE SCREW. i _
NOTE: -v
SEEPAGE PAN. i (1) - FIXTURE UNITS AS SHOWN OR EQUAL
MAXIMUM TAILPIECE (2) - ALL FIXTURES SHALL COMPLY WITH TABLE 46R-2 OF S.F.B.C. E
LENGTH IS 2 FEET. <
MAXIMUM 15' WHERE - Q
ENLARGED WASTE SLOPE WASTE AT CONCRETE
LINE IS USED AS A TWO PERCENT.
COMBINATION' WASTE SLAB
U
AND VENT SYSTEM. C
PROVIDE TRAP PRIMER IF RE-
QUIRED BY LOCAL AUTHORITIES. MAXIMUM 5' ON 2' V
v
OTHERWISE DEEP-SEAL P-TRAP. WASTE OR 6' ON 3'.
NOTE
s
LOCATE FLOOR DRAINS WHERE SHOWN ON DIMENSIONED ARCHITEC- V
TURAL PLAN. IF FLOOR STRUCTURE INTERFERES NTH FLOOR DRAIN, PROVIDE WCO WHERE SHOWN ON PLAN, AND ON SANITARY WASTE BRANCHES Q
MOVE SIDEWAYS IF POSSIBLE, OTHERWISE MOVE BACK. ALWAYS LOCATE NOT SERVED WITH A FLOOR CLEANOUT: LOCATE ABOVE FIXTURE FLOOD RIM
WHERE EASILY ACCESSIBLE, BUT NOT IN FOOT TRAFFIC. IF SITUATION WITHIN 4' OF FLOOR. CONSULT LOCAL CODES FOR OTHER WCO REQUIREMENTS.
IS FLOOR SLAB ON GRADE, PROVIDE BACKFILL PER SPECIFICATIONS. v
IF CONCRETE FLOOR IS NOT EXISTING, SET DRAIN IN PLACE AND POUR ,v
AROUND IT. IF CONCRETE FLOOR IS EXISTING, SAW CUT OR CORE DRILL WALL CLEANOUT DETAIL v0,
IT. SET DRAIN BODY IN PLACE AND POUR AROUND IT. RECESS TOP OF NOT TO SCALE Q
FLOOR DRAIN 1/2' BELOW FLOOR SURFACE AND SLOPE FLOOR TO IT.
c
K-04'd CO`..: !T1�U ?,)J FIT #: : :rr3S' O
Fla! C T �;NkGI<R_ � _r-- F .:r PLUMBING NOTES a
FLOoOR DRAIN DETAIL °--°
0
NOT TO SCALE
e73.B•OBOBgS O � AT Clint Ma4ra i d 4�6
, 3 R;t7cc, FL 334
S�1.4'�Syi,�iyj�
COntUldtl� y ��W r •:3
D O.R5(TOR FLEC .C�� tiG[tiEF. I` _s,:
. .
PO.1
D'REI'TOA OF 4ECHAN„C:AL E�GINFEI SCa �f .� � A •', 00