Loading...
00-0332-114 H' - _. ...... if EQUAL TO: SQUARED PANEL 'G° VOLTAGE: 120/208 V., 3PH.,4W. m TYPE: LOAD CENTER CU BUS/GND BUS MAINS: 150 AMPS. NEUTRAL: F/N r N o w �v o MOUNTING: FLUSH TYPE MAINS: MLO Sim N O o s1 a 00 a� I PHASE CIRCUIT CIRCUIT PHASE Co o �,�� 'o ®I NO. LOAD DESCRIPTION A B C BKR P W C C W P BKR A B C LOAD DESCRIPTION N0. • o �LZ (D 1 RTU 13 * 5400 60 3 6 1' 1 T 12 1 20 720 TELEPHONE BACKBOARD 2 s ® ri °z ! � Z -� 3 5400 1 2° 12 1 20 720 COPIER 4 , m v 5 5400 1Z2" 12 1 20 720 RECEPTACLES 6 ::E J oN - 7 RECEPTACLES 720 20 1 12 11Z 11Z 12 1 20 720 RECEPTACLES 8 ° g RECEPTACLES 720 20 1 12 1 1Z 1 1Z 12 1 20 720 RECEPTACLES 10 11 BATHROOM RECEPTACLES 720 20 1 12 1/2' 1/2* 12 1 20 720 RECEPTACLES 12 N 3 13 BATHROOM RECEPTACLES 720 20 1 12 1/2* 1/2' 12 1 20 1000 REFRIGERATOR 14 ,,,®, 15 RECEPTACLES 720 20 1 12 1/2" 1/2* 12 1 20 720 SERVER 16 bm 17 RECEPTACLES 720 20 1 12 1/2* 3/4° 10 1 2 30 1 2250 EWH 18 o 19 RECEPTACLES 720 20 1 12 1 2° 2250 20 (D z Z 21 LIGHTING 1100 20 1 12 1 2° 1 2° 12 1 20 1520 LIGHTING 22 §� m 23 LIGHTING 1800 20 1 12 1/2* 1 2° 12 1 20 500 LIGHTING 24 0 25 SPACE - - - - - - - - SPACE 26 vom C - � C � UJ FIRE 27 ALARM SYMBOL LEGEND FIRE ALARM NOTES SPACE _ _ _ _ _ _ _ _ SPACE 28 Cl- 29 SPACE SPACE 30 31 SPACE - - - - - - - - SPACE 32 LU'_U) 33 SPACE - - - - - - - SPACE 34 CONTRACTOR SHALL INCLUDE AS PART OF HIS/HER BID SIGNED/SEALED FIRE ALARM _ _ _ _ _ _ _ _ 35 SPACE SPACE 36 }-UJ FACP ADDRESSABLE FIRE ALARM PANEL NOTIFIER #AFP-200 ENGINEERED DRAWINGS THAT COMPLY WITH THE NEW MIAMI DADE COUNTY FIRE n :2 W PROVIDED WITH POWER SUPPLIES AND BATTERY BACKUP ALARM PERMIT REQUIREMENTS > ? = AS REQUIRED. THE DRAWINGS SHALL INCLUDE A RISER AND A FLOOR PLAN AT 11T SCALE INCLUDING ALL DEVICES SHOWN IN BASE DESIGN AND ANY ADDITIONAL DEVICES A 12,250 VA TOTAL VA 36,700 FIRE ALARM REMOTE ANNUNCIATOR NOTIFIER #LCD-80 REQUIRED BY APPLICABLE CODES. PLANS SHALL INCLUDE THE FOLLOWING ITEMS: B 11,620 VA ANN 1 FIRE ALARM SYSTEM SHALL BE U.L. LISTED NFPA 72 APPROVED. C 12,830 VA TOTAL AMPS 102 NOTES: 1. (+) COOLING AND HEATING LOADS ARE NON-CONCURRENT. PROVIDE HACR TYPE BREAKERS PHOTOELECTRIC SMOKE DETECTOR NOTIFIER #SD-751/B710LP 2 UPON ACTIVATION OF FIRE ALARM SYSTEM BY MANUAL STATION, THE FOLLOWING SHALL TAKE PLACE: 2. ALL CIRCUIT RUNS SHALL BE PROVIDED WITH A GROUND EQUIPMENT CONDUCTOR SIZED PER NEC 250-122 A ENERGIZE ALARM SIGNALING DEVICES ADA HORN/STROBE NOTIFIER #S24 SERIES (SEE FLOOR PLAN B SOUND AUDIBLE ALARMS AND FLASH VISUAL SIGNALS EQUAL TO: SQUARE D PANEL "H" VOLTAGE: 120/208 V., 3PH.,4W. C ALERT LOCAL FIRE DEPARTMENT OR PROPRIETARY SYSTEM A FOR CANDELA REQUIREMENTS) D CAUSE ZONE IN ALARM TO BE DISPLAYED ON THE ANNUNCIATOR TYPE: LOAD CENTER CU BUS/GND BUS MAINS: 125 AMPS. NEUTRAL: F/N MOUNTING: SURFACE TYPE MAINS: 3P-125A M.C.B. (SERVICE RATED) 3 ALL WIRING AND CONDUIT SIZE SHALL BE IN ACCORDANCE WITH PHASE CIRCUIT CIRCUIT PHASE Q PULL STATION NOTIFIER #BGX101 MANUFACTURER'S RECOMMENDATION, AND REQUIREMENTS OF NEC, LOCAL N0. LOAD DESCRIPTION A B C BKR P W C C W P BKR A B C LOAD DESCRIPTION N0. CODES AND NFPA, IN NO CASE SHALL THE WIRING BE SMALLER THAN #16 4 EF-4 696 20 1 12 11/2* 1 2" 12 1 20 864 SUMP PUMP 2 F.P.L. CU. IN 3/4" CONDUIT. FPLP CABLE NOT ALLOWED. 1176 20 1 12 1 1/2* 12 1 20 864 SUMP PUMP 4 1 - DIALER DIALER NOTIFIER #411-LID 4 QUANTITY OF WIRES PER DEVICES SHALL BE AS REQUIRED BY 5 SPACE - - 1 20 SPARE 6 MANUFACTURER. F D 2 1 1/2* 12 1 20 500 ELEVATOR PIT RECEPTACLES 8 9 TELEPHONE BACKBOARD 720 20 1 12 11Z 11Z 12 1 20 200 ELEVATOR PIT LIGHTS 10 5 SYSTEM TO BE POWER LIMITED. 11 RECEPTACLES 720 20 1 12 I12° 11Z 12 1 20 1 200 IEF-5 12 OW WARNING LIGHT (DO NOT USE) 6 VISUAL ALARMS PER ANSI Al 17.1,4.26, SFBC CHAPTER 515.3 AND A.D.A. 13 ROOF RECEPTACLES 720 20 1 12 1 2" 1 2" 10 1 20 720 D.F. 14 Q� 15 FACP 720 20 1 12 1 2° 1 2° 12 1 20 720 RECEPTACLES LIGHTS 16 � 7 IDENTIFY ALL ROOMS AND SPACES AND INDICATE THE SCOPE OF WORK, 17 FACP DIALER 720 20 1 12 11Z 11Z 10 1 20 720 DF 18 � INCLUDING A TITLE BLOCK AS PER SFBC SECTION 302.2. 19 CORRIDOR LIGHTS * 1200 20 1 10 3 4° 1 2" 10 1 20 800 STAIR LIGHTS 20 ADD STROBE LIGHT NOTIFIER #S24 SERIES (SEE FLOOR PLAN Q) FOR CANDELA REQUIREMENTS) 8 SHOW CANDELA RATING INDICATED ON THE FLOOR PLAN, AND LOCATE ALL 21 EXTERIOR LIGHTS 800 20 1 10 31/4° 1 2° 10 1 20 800 STAIR LIGHTS * 22 U > HORNS OR SPEAKERS AS PER NFPA 72-6.3. 23 PARKING LIGHTS + 1000 20 1 12 11Z 3/4° 10 1 20 500 ELEVATOR ROOM LTS RECEPTACLE 24 Q (� _ ��• _ SMOKE DUCT DETECTOR NOTIFIER #DH-502/SDX551 WITH 9 SMOKE DETECTOR AND HEAT DETECTOR SPACING SHALL COMPLY WITH 25 ENCLOSED PARKING LTS 900 20 1 10 3/4° 3/4° 10 1 20 500 ELEVATOR CAB LTS 26 27 ENCLOSED PARKING LTS •+ 1000 20 1 12 11Z 11Z 12 1 20 400 LIGHTS 28 SAMPLING TUBES NFPA 72, CHAPTER 5 INDICATING HEIGHT IF GREATER THAN 10' OR 29 LIGHTS 500 20 1 10 1/2° 1 z 12 1 20 720 EMERGENCY EXIT LIGHTS 30 a (n DESCRIBING CONDITIONS IF NOT FIAT CEILING. 31 RECS 1000 20 1 10 1/7• 1/z 10 1 20 500 SMOKE DAMPERS 32 (n r— U TS TAMPER SWITCH 10 ALL FIRE ALARM PANELS, POWER BOOSTERS, DEVICES, MODULES, DIALERS, 33 AHU 7 * k• 1925 30 2 10 3/4° 3/4° 10 2 20 832 CU 7 +# « 34 -aJ � , COMPONENTS, APPLIANCES, INITIATING DEVICES, AND RELAYS SHALL BE L 35 1925 - - - - - - - - 832 36 p SHOWN ON THE FLOOR PLAN AND ON THE RISER IDENTIFIED BY THEIR OWN 37 SPACE - - - - - 1 500 EF-2 38 — 0 FS FLOW SWITCH. UNIQUE IDENTIFICATION NUMBER. 39 SPACE - _ - - - - - - - - - - SPACE 40 � 11 EACH INITIATING DEVICE CIRCUIT, SIGNALING LINE CIRCUIT AND 41 SPACE - - - - - - - - SPACE 42 VS NOTIFICATION APPLIANCE CIRCUIT SHALL BE SHOWN ON THE RISER, A 10,192 VA TOTAL VA 30,146 U (1)` B 10,117 VA 0 7 837 VA TOTAL AMPS 83. `+- _ 12 PROVIDE THE MAXIMUM CAPACITY IN AMPS (OR WATTS FOR SPEAKER C 9, 0 C: (N CIRCUITS) FOR EACH NOTIFICATION APPLIANCE CIRCUIT AND INDICATE THE — 0 LOAD OR CURRENT DRAW OF EACH DEVICE. NOTES: 1. (+) ON TIME CLOCK #1 2. (+«) ON TIME CLOCK #2 • — 13 PROVIDE THE MAXIMUM NUMBER OF INITIATING DEVICES FOR EACH 3. ( k•) ON TIME CLOCK #3 INITIATING DEVICE CIRCUIT OR SIGNALING LINE CIRCUIT AND INDICATE THE 4. ALL CIRCUIT RUNS SHALL BE PROVIDED WITH A GROUND EQUIPMENT CONDUCTOR SIZED PER NEC 250-122 Z E SPECIFIC NUMBER AND TYPE OF EACH DEVICE. 5. («*r#) COOLING & HEATING LOADS NON-COUNCURRENT. PROVIDE HACR TYPE BREAKES. 14 FOR UPGRADES OR ADDITIONS TO EXISTING SYSTEMS, SHOW THE CAPACITY Q OF THE SYSTEM AND ALL MODIFIED CIRCUITS, THE EXISTING LOAD OR CURRENT DRAW OF EACH CIRCUIT OR COMPONENT, THE CAPACITY Lighting Fixture Schedule a 0 AVAILABLE, AND THE ADDITIONAL LOAD OF THE ADDED DEVICES OR Type Luminaire Manufacturer/ Volts Lamp Information Mounting Finish Remarks � A CIRCUITS. Description Catalo Number No. Type Watts — r 16 DESIGNATE ALL INITIALING DEVICE CIRCUITS, NOTIFICATION APPLIANCE A CIRCUITS AND SIGNALING LINE CIRCUITS BY CLASS OR STYLE OR BOTH. 2' X 4' TROFFER LITHONIA 2SPG-332-Al2-GLR-GEBI0 120 3 32T8 120 RECESSED WHITE -- 16 CONDUCTOR TYPES, SIZES AND NUMBER, AND RACEWAY SIZES SHALL BE Al INDICATED ON THE RISER. 2' X 4' TROFFER LITHONIA 2SPG-232-Al2-GLR-GEBIO 120 2 32T8 80 RECESSED WHITE B 17 CUT SHEETS OF ALL COMPONENTS, APPLIANCES AND DEVICES SHALL BE 1' X 4' WRAPAROUND LITHONIA CB-232-120-GLR-GEBIO 120 2 132T8 80 SURFACE WHITE SUBMITTED WITH THE PLANS FOR VERIFICATION OF CALCULATIONS AND C SPECIFICATIONS. 1' X 4' STRIP LITHONIA C-232-120-GLR-GEBIO 120 2 132T8 80 SURFACE WHITE PROVIDED W WIRE GUARD 18 PROVIDE DETAILED BATTERY CALCULATIONS FOR EACH BATTERY BACKUP. D THE MANUFACTURER'S FORMAT SUPPLIED IN EACH CONTROL PANEL MANUAL STAIR LIGHT LITHONIA WVW-232-GLR-GEB10 120 2 32T8 80 WALL WHITE IS THE PREFERRED FORMAT. E 19 ALL DIALERS SHALL DETAIL AND MEANS OF TRANSMISSION TO THE INCANDESCENT DOWNLIGHT LITHONIA ADVANTAGE LP6-6131 120 1 75PAR-30 75 RECESSED WHITE RECEIVING STATION. F FLOURESCENT DOWNLIGHT LITHONIA GOTHAM AFV-32TRT-6AR 120 1 321RT 40 RECESSED WHITE 20 THE EXACT MANUFACTURER'S MODEL NUMBER FOR EACH FIRE ALARM COMPONENT, DEVICE OR APPLIANCE SHALL BE INDICATED ON THE PLAN. G -, 03.28.2000 FLOURESCENT DOWNLIGHT LITHONIA GOTHAM AFV-18TRT-5AR 120 1 18TRT 25 RECESSED WHITE Revisions 21 EXISTING, NEW, REPLACED OR RELOCATED DEVICES SHALL BE AS INDICATED ry AS APPLICABLE. FLOURESCENT DOWNLIGHT LITHONIA GOTHAM LGF-1 42TRT-7RW-CHL 120 1 42TRT 50 RECESSED WHITE BLDG. DEPT. COMMENT 22 PROVIDE REMOTE ANNUNCIATOR AT BUILDING ENTRANCE AS REQUIRED. I Al 5-03-00 FLOURESCENT DOWNLIGHT LITHONIA ADVANTAGE LP6F-682 120 1 130TT 18 RECESSED WHITE 23 ALL UNOCCUPIED ROOMS SHALL BE PROVIDED WITH SMOKE DETECTORS. 24 ALL DEVICES SHALL BE SHOWN ON PLAN AND RISERS. DO N(YF LNSTtiLL FTRF AlARINi WALL LIGHT LITHONIA VGR2-42TRT-120 120 1 4 50 WALL WHITE PROVIDED W EMERG. BATT. PK Project 25 PROVIDE DIALER WITH AT LEAST TWO (2) PHONE CONNECTION, PERM HIS DRAWING K iV 9 9 33 a I e rn ELEVATOR PIT LTS RIG-A-CITE VPW100GG75 120 1 100WA19 100 WALL WHITE Fi � 1 ::n coritictor's w'orkin8 plans shall L _,ued for Tset�n:t approval to Miami- CLOSET LIGHT LITHONIA #10001 120 1 32W 40 SURFACE WHITE ,e('�uiityhE'Department. M ApprwRd fir t uildin;1?acmit onV. SHOWER LIGHT LITHONIA ADVANTAGE LP6F-6LD3PF 120 1 130TT 18 RECESSED WHITE SUITABLE FOR WET LOCATIONS N Em I %'FAY"P" �Y GARAGE LIGHT LITHONIA PGR-LOOM-FUSED 120 1 100WMH 125 SURFACE P PARKING POLE LUMINAIRE LITHONIA BV2-25OM-R4-FUSED 120 1 250WMH 312 POLE SEE POLE DETAIL S Sheet WALL PACK LITHONIA TWA-LOOM-FUSED 120 1 100WMH 125 WALL MOUNT + 13'-0° AFF 4 E SELF-CONT. BATTERY OP. EMER. LT. LITHONIA QUANTUM 6ELM2-H 120 INCLUDED WALL WHITE WALL 0 7'4 rn X SCHEDULES /°� EXIT LIGHT BATTERY OPERATED LITHONIA QUANTUM 'LET SERIES 120 INCLUDED UNIVERSAL WHITE i < •" a �i xi EXIT LIGHT BATTERY OPERATED LITHONIA EXTREME SERIES 120 INCLUDED UNIVERSAL WHITE WET LABEL i oa Seal (AR 16320) —