00-0332-113 i 1 I m �_ E LZ LLJ La - - c>- 1 or 2 Hour Fire Rated �, �; z ►- o ° _ 2 Hour Fire Rated Through IQ � a o s a 60 E 0 -1� Y nJ� g n 2 Hour Fire Rated Through ��p ,� Through Penetration Firestop forLS `a55fF�� Penetration Firestop for Penetration Firesto for U (IL1L5 CO �"� Single Metal Pipe through Multiple Metal Pipe through �, w ° 9 UL Single Metal Pipe through �• Z ,� °Gypsum walls using ® Concrete walls using Concrete floors or block walls ° m 05 Z or FIRE - SHIELD, s FIRE-SHIELD or FIRE-SEAL, using TREMstop Acrylic ' � w� N ° ° ° 1'ste Y m F-rating = 1 and 2 Hr. - - V o 0- X g W�J1012 E-rating = 2 Hr, F rating - 2 Hr, -6 w Q W T-rating = 0 Hr, 1 1 T-rating = 0 Hr. 0�� In UL # WL1051 C377) T-rating = Hr, 1 UL # CAJ1205 �C W � iR:: Q CC14 3C A Qo- n 3 C) 1 = a: wz z a 3 3A 3C 4 4 �� o 4 © w ` _ r a W 0 Q, 2 O O - ° U Z 4 t '� LLJ 2 3B o w � Z a l� Wall assembly = 5' thick concrete, with Max area of opening 35,75 sq, in. 1� Pre-Rated Concrete Floors or Block Walls = Min, 4-1/2' thick, 0 *Steel Pipe - 2' diam, (or smaller) Sch, 5 or heavier. with annular space range of 0' to 718'. 1� 1 or 2 - hour fire rated gypsum wallboard/stud assembly *Conduit - 2" diam, (or smaller) EMT, Q Conduit - Nom, 4' dia (or smaller) steel conduit or EMT *Max, 5 pipes or conduits, (angular space range, min, 1/4' to max, 5/8') 3 A) Steel sleeve - on it MSG alv, sheet fitted within TO SHUNT 9 © Packing Material - Mineral wool (min 4 pcf) compressed min, TRIP BREAKER Conduit - 4" dlam (or smaller) EMT or rigid steel opening and secured to both sides 50% and installed into the opening to obtain of wa(l, min. 4' thickness 35• ELEVATOR CHEMPRONIC #604 H 03 TREMCD # FIRE-SHIELD - min 1/2' thickness of sealant B) Packing material - Min ® TREMCD # TREMstop Acrylic - Min, 112" sealant applied within H 4' thickness ceramic fiber TOP OF 135 (TYPICAL). insulation (6 cf) friction fitted annulus, and a minimum 1/4 sealant applied at SHAFT installed within opening with a min, of 1/4 crown p point contact: at the floor surface for f(oors, ELEVATOR around ground the penetrating item applied flush C) Min, ' %thickness FIRE-SHIELD or FIRE-SEAL, with a" or both surfaces for walls. MACHINE ROOM with both side of wall assembly, crown formed around penetrating items 37 H SIDE FIRE AND/OR SMOKE RATED WALL OR FLOOR PENETRATION DETAILS OF PIT RE Q FOUNDATION PARTIAL RISER OF HEAT DETECTORS 4_J STEEL REBAR FOR ELEVATOR SHUNT TRIPPING. ACCESSIBLE JUNCTION BRANCH CIRCUIT FINISH SLAB N.T.S. -+-� 8 GROUNDING ELECTRODE BOX 3/4" DIA x20'-0" LONG ° MINIMUM ° ° � �— J —'� M d ° ° CD SUPPORT FIXTURE AT 0 (f� 4 318" FLEXIBLE CONDUIT. EACH CORNER TO N a ° ° MAX 6FT. AS PER NEC 350 COMPLY WITH NEC 300-11(a) U Cll Q c C N COPPER CONDUCTOR TO MAIN DISCONNECT(S) LIGHTING FIXTURE FINISHED CEILING ELEVATOR ELECTRICAL NOTES O - o 0 a (SEE RISER) . — a 6�0' 1, PROVIDE ELEVATOR DISCONNECT INSIDE ELEVATOR MACHINE ROOM WITH TIME • — a RECESSED FLOURESCENT LT. FIXTURE CONNECTION DETAIL DELAY FUSES (RK5) WITH REJECTION CLIPS. FUSES ARE TO BE SIZED AS z REQUIRED BY ELEVATOR COMPANY SHOP DRAWINGS. (NEC 620-5). a ° a COLD WATER METAL N.T.S. °�d , ° PIPE MINIMUM OF 2. PROVIDE A DEDICATED 120V, 20A, BRANCH CIRCUIT PER NEC 620-22 FOR a 20 FEET IN CONTACT NOTES: ELEVATOR CAR LIGHTS WITH A DISCONNECTING MEANS. (MUST BE LOCKABLE IN WITH EARTH (BELOW 1.- ALL RECESSED LIGHT FIXTURES ARE TO BE CONNECTED AS DETAILED, THE OPEN POSITION AND WIRED TO ELEVATOR CONTROLLER). r G U.L. RATED CLAMP GRADE) 2.- ALL JUNCTION BOXES ARE TO BE READILY ACCESIBLE. 3. LIGHT FIXTURE INSIDE ELEVATOR MACHINE ROOM SHALL BE LENSED TYPE; OR O FOR CONCRETE 3,- PROVIDE FIRE PROOF TENT AS REQUIRED TO KEEP UL CEILING RATING. IF INDUSTRIAL TYPE, SHALL BE PROVIDE WITH WIRE CARDS AND TUBE CARD. U' ' ENCASEMENT (TYPICAL) \ TYPICAL 4. PROVIDE A 20A, 125V, GFI RECEPTACLE IN ELEVATOR MACHINE ROOM AND PIT. EXOTHERMIC CONNECTION 5. PROVIDE A DEDICATED TELEPHONE LINE TO ELEVATOR CONTROLLER. (ONE (SEE NOTE BELOW) DEDICATE LINE PER ELEVATOR). 6. WHEN BANK OF ELEVATORS ARE POWERED BY AN EMERGENCY GENERATOR, GROUND CLAMP PROVIDE EMERGENCY POWER SELECTOR SWITCH WITH CONTROL WIRING TO ' MASTER OR GROUP ELEVATOR CONTROLLER. (2 SETS N.O. DRY CONTACTS, EMERGENCY POWER & NORMAL POWER, WITH 10 SECOND TIME DELAY). THESE CONTACTS WILL ALLOW FIRE DEPARTMENT TO SELECT WHICH ELEVATOR WILL RUN ON EMERGENCY POWER, AND WILL ALSO ALLOW REMAINING ELEVATORS TO BE LOWERED ONE AT A TIME TO DESIGNATED FLOOR. 7. ELEVATOR CAB(S) SHALL BE PROVIDED WITH A TELEPHONE OR A MEANS OF TWO-WAY COMMUNICATION. TYPICAL 314" DIA x 1OFT 3p, S. PROVIDE TWO VAPOR TIGHT LIGHT FIXTURES CONTROLLED BY A SWITCH INSIDE LONG COPPERCLAD STEEL EACH ELEVATOR PIT. GROUND DRIVEN ROD, 9. WHEN A HYDRAULIC ELEVATOR HAS PROVISIONS FOR LOWERING BY BATTERY, THE MACHINE ROOM DISCONNECT, WHILE IN THE "OFF" POSITION (OPEN), MUST PREVENT THE ELEVATOR FROM LOWERING UNDER BATTERY POWER TO SHUT DOWN THE BATTERY LOWERING FEATURE WITH THE ELEVATOR DISCONNECT 03.28.2000 SWITCH, THE CONTRACTOR SHALL PROVIDE AN AUXILIARY SET OF CONTACTS IN Revisions THAT SWITCH AND A PAIR OF #16 WIRES TO THE ELEVATOR CONTROLLER TO BUILDING SERVICE GROUND DETAIL DISABLE THE BATTERY LOWERING FUNCTION. THE BATTERY LOWERING FUNCTION SHALL ALSO BE DISABLED UNDER SHUNT TRIP OPERATION, SEE BELOW. SCALE: N.T.S. 10. WHEN A BUILDING IS PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND NOTE SPRINKLER HEADS ARE INSTALLED IN THE ELEVATOR SHAFT, THE ELEVATOR PIT, IF BOLTED GROUND CLAMPS ARE USED IN LIEU AND THE ELEVATOR MACHINE ROOM. PROVIDE FIXED TEMPERATURE HEAT OF EXOTHERMIC WELD PROVIDE A GROUND ACCESS DETECTOR NEXT TO EACH SPRINKLER HEAD ON THE TOP OF THE SHAFT, SIDE Project WELL FOR EACH GROUND ROD. OF THE ELEVATOR PIT, AND ELEVATOR MACHINE ROOM. HEAT DETECTOR TEMPERATURE SHALL BE LOWER THAN SPRINKLER HEAD TEMPERATURE, VERIFY 9933a1em WITH FIRE PROTECTION CONTRACTOR PRIOR TO ORDERING. THESE HEAT DETECTORS ARE NOT CONNECTED TO THE BUILDING'S FIRE ALARM SYSTEM, BUT ARE USED EXCLUSIVELY FOR TIPPING OF THE ELEVATOR SERVICE DISCONNECT AT THE MAIN ELECTRICAL ROOM. PROVIDE SHUNT TRIP BREAKER AT EACH ELEVATOR SERVICE DISCONNECT. IF ELEVATOR IS EQUIPPED WITH A BATTERY LOWERING FEATURE, AN ADDITIONAL ENS) SET OF AUXILIARY CONTACTS MUST BE PROVIDED AT THE HEAT DETECTOR AND ELECTRICAL D E T A I L S 2#16 WIRES SHALL BE PROVIDED TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE, IN LIEU OF ADDITIONAL CONTACTS AT THE HEAT DETECTORS, THE CONTRACTOR SHALL PROVIDE ADDITIONAL WIRING FROM THE SHUNT TRIP BREAKER TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE. THIS WIRING WILL BE INSTALLED IN SERIES WITH Sheep ! of 12 THE AUXILIARY DISCONNET SWITCH CONTACTS, THE DRY CONTACTS CONTAINED IN THE AUXILIARY SWITCHES ARE CLOSED WHEN EITHER THE SHUNT TRIP OR DISCONNECT IS IN THE "ON" POSITION AND WILL BE OPEN WHEN THE » �a`� Ao E DISCONNECT IS OPENED OR SHUNT TRIP/HEAT DETECTOR ACTIVATED. AW 4• O- Sea1 16 3 2'' r, r