00-0332-103 fr " INSTALLATION NOTES J u N a�i M �' C m� N K) Ln 2x2x1/4< CONTINUOUS DUCT SUPPORT 1 COMBINATION FIRE AND LEAKAGE RATED SMOKE A � `� cO C FIRE RATED DAMPERS ARE DESIGNED TO OPERATE WITH BLADES �_ '� � ¢` °o � o 00 BOLTED THROUGH WALL RUNNING HORIZONTALLY AND SHALL BE INSTALLED t� o 0 1 t� WALL SLAB. � � �' � Div y ` o � 1 � FOR FRAMING WITHIN THE FIRE WALL OR SLAB DUCT OPENING. o, o U 1 o ANCHOR BOLTS (MIN. 2 PER SIDE) OF OPENING VERTICAL INSTALLATION IS DEPICTED. HORIZONTAL L z a °`' E � u- co —"S' SLIP JOINT SEE INSTALLATION IS SIMILAR. — — — — — — — — GALVANIZED METAL HOOD Q Z °� N - °r REMOVABLE CAP THIS END CLOSED. PROV. Y m N Z -) ARCHITECTURAL 2 THE FIRE WALL OPENING SHALL BE A MINIMUM m o �, rn o E o 'a „ EXPANDING GROUT AROUND Z I ) �v DRAWINGS OF 1/8 PER FOOT LARGER THAN THE OVERALL PIPES. 10 SIZE OF THE DAMPER AND SLEEVE ASSEMBLY FILL CAVITY AND Y o S 10 3 THE SLEEVE GAGE SHALL BE EQUAL TO OR HOOD WITH INSULATION 12" MIN. at3 �- a /\ - 1" MINIMUM HEAVIER THAN THE GAGE OF THE DUCT ° m Q W OVERLAP 2 x 4 PRESSURE TREATED N = 4 MOUNTING ANGLES SHALL BE 1 1/2" X 1 1/2' EFRIGERANT. PIPING/ C" 3 r GAGE MINIMUM AND FASTENED WITH WOOD NAILER H N0. 10 BOLTS ELECTRICAL CONDUITS = 0.) q OR SCREWS, 3 16" DIAMETER STEEL RIVETS OR _ ��, o 1/2"x1/2 1/2 LONG TACK WELDS. SPACE FASTENERS 8' q EXTERIOR W.M. SCREEN \ 2 1/4 MINIMUM ONN CENTER PROVIDE A CONTINUOUS 1 8" BEAD OF SCREWS-- ___ _� `', ! SLOPE 1 WEEP HOLES W zd ° LOUVER \ CLEARENCE SEALANT. WHEN FASTENING THE DAMPERS TO THE `,, ' ;j 1B � ITEM DESCRIPTION SLEEVE, DAMPERS SHALL BE FASTENED WITH 1 ' 2 x 12 PRESSURE ....................... :.•.`;..";...... o -20 BOLTS, NO. 10 SCREWS, OR 1/2 LONG WELDS TREATED WOOD �� 0 1 OPERATOR STAGGERED INTERMITTENTLY ON BOTH SIDES. FRAME METAL CONTAINER FLASHING 'R r ACTUATOR/ SPACE FASTENERS 6" ON CENTER AND A MAXIMUM `� ° c °� u- 1 3 4 OF 2' FROM THE ENDS OF THE JOINING SECTIONS 1 ` J W J 2 FUSIBLE ROD OR FROM EACH CORNER. A CONTINUOUS 1 8' BEAD 18" MIN. �_ m V) q 3 AUXILIARY OF SEALANT SHALL BE APPLIED ON THE MULLION w C3 PITCH BOTTOM OF DUCT 4 PER FT f I , °- °z OPERATING I '�, ,� � °� -' / TYPICAL °S" SLIP JOINT 0 JACK SHAFT JOINT. PRESS THE SURFACE OF THE SEALANT IN TWO-PLY FLASHING •� 12 Lo a PLACE TO DISPEL ANY AIR. ANOTHER BEAD OF 0 vn � � oz CONTINUOUS ALL AROUND 5 4 DAMPER FRAME THE SAME SEALANT SHALL BE APPLIED BETWEEN - �.. .. ... ...�� � �o� � � 5 FUSIBLE LINK THE DAMPER AND SLEEVE IN THE SAME MANNER FIBER CANT STRIP o BEND DUCTWORK OVER THE BLADE W/LOCK ' - W 5 SEALANT TO BE APPLIED SHALL BE y �, BUILT-UP ROOF o N s � ��.. N Z= OF LOUVER CONTINUOUS ALL AROUND O 6 SLEEVE DOW-CORNING 732, OR GE RTV 180 '� 7 NEGATOR _ � �- WIDTH OF LOUVER 7 SPRING 6 DAMPER SLEEVE SHALL NOT EXTEND MORE THAN 6 BEYOND THE FIRE WALL OR PARTITION AND NOT 10 GAUGE SHEET METAL 8 MOUNTING MORE THAN 9" ON THE OPERATOR/ACTUATOR SIDE ANGLES € BOLT 7 THE DAMPER SHALL BE INSTALLED IN A 6 9 S-JOINT, WORKMANLIKE FASHION AS INTENDED BY THE � � s` f FOR LOUVER MOUNTING DETAIL SEE ARCH. DWG'S. 10 SLEEVE TO � � DUCT ORDER OF DESIGN, IN ACCORDANCE WITH THE 10 CAULKING MANUFACTURER'S RECOMMENDATIONS MATERIAL 8 THE DAMPER CONSTRUCTION AND INSTALLATION 2 x 6 PRESSURE SEAL WATER TIGHT SHALL COMPLY WITH UNDERWRITERS LABORATORIES TREATED WOOD ROOF DECK PLATE SAFETY STANDARDS 555, 555S AND NFPA 90A 9 9 ACTIVATION OF THE SMOKE DAMPER SHALL BE THROUGH TYPICAL EXTERIOR LOUVER AND e BLDG. FIRE ALARM SYSTEM. COORDINATE WITH ELEC./FIRE ALARM CONTRACTOR. REFRIGERANT PIPING ROOF PENETRATION DETAIL DUCT CONNECTION DETAIL N.T.S. N.T.S. COMBINATION FIRE/SMOKE 15 ROOF CURB DETAIL NOTES - DAMPER DETAIL 1 i O TYPICAL A/C UNIT AIR HANDLING UNIT SECURED DROP-IN ANCHOR �2 FACTORY FAB. ROOF CURB (12" MIN.) TO STRUCTURE W HANGER RODS. N.T.S. 14 PROVIDE VIBRATION ISOLATORS MASON MODEL PC30N OR EQUAL CONC FLOOR DECK DETECTOR WHERE SPECIFIED UNION (TYP) O TREATED WOOD NAILER ' CAP 3 O RIGID INSULATION (FIELD APPLIED) a DUCT MOUNTED SMOKE 5 EQUIP./ROOF SUPPORTING STRUCTURE Q� 0 3/8 q 0 THREADED 2 13 (SEE STRUCTURAL DWGS) REF. PIPING HANGER RODS I FLOAT SWITCH OUTSIDE AIR DUCT W/ WIRHDTIN SERIES CIRCUIT 4 12 O6 ROOF DECK Q) - MANUAL VOLUME DAMPER I O � SEE FLOOR PLAN 1/8 / FT SUPPLY SLOPE $ U � � SEE FLOOR PLAN FOR SIZES AUXILIARY DRAIN 11 10 O7 ROOF INSULATION (SLAB ASSEMBLY) Q FOR SIZE. f PAN (GALVANIZED Z pl RET. AIR DUCT AUXILIARY DRAIN PAN WITH FLOAT SWITCH SHEET 18 GA.) - �\ 9 1�8 FINISH ROOFING MATERIAL W/ O.B.D. SEE (3' WATER SEAL) NOTE: 1�9 ROOFING FELT O FLOOR PLAN INSULATE DRAIN PAN NTH 1/2' THICK 7 0) V) � FIBERGLASS BLANKET WITH VAPOR FOR SIZE BARRIER OR SHEET FOAMED PLASTIC 10 CANT STRIP (FIELD SUPPLIED) ,� -+-� -0 CONDENSATE DRAIN LINE AND INSULATION WITH APPROVED FIRE D RETURN AIR PLENUM WITH FILTER RATING ON OUTSIDE SURFACE ONLY 11 COUNTER FLASHING = Q� Q TRAP.REFER TO PLUMBING DWGS. A/C UNIT DRAIN PAN AND m LOCATE FOR DOOR(S),FI ACCESSIBILITY. 6 12 HOLD DOWN ANGLE (FIELD SUPPLIED) (� LOCATE FOR EASE OF ACCESSIBILITY. �-FIN. CEILING CONDENSATE TRAP DETAIL Q) � ^ 5 13 SECURE TO LIFTING CHANNEL W/ #10 TEK U 0 O AIR HANDLING UNIT MOUNTING DETAIL SCREWS, 12"o.c., MIN. 3 PER SIDE ; 14 LIFTING CHANNEL (VARIES PER MANUF.) O _ N.T.S. (TYPICAL FOR AHU-1 ,2,3,4) O MAIN DUCT 15 GASKET/SEALANT BY EQUIP. MFGR. _ �A ROOF DECK AND INSULATION SHALL RUN CONTINUOUS WITHIN PERIMETER OF ROOF CURB Z SECURE W/PLASTIC STRAP TO INSULATIO REFRIGERANT LIQUID LINE AIR AIR WITH OPENINGS CUT OUT FOR DUCT CONNECTIONS ONLY WHENEVER POSSIBLE. IF ROOF DECK IS CUT OUT WITHIN PERIMETER OF ROOF CURB, AND IF CALLED FOR ON EQUIPMENT ` FLOW FLOW SCHEDULE AND/OR IN SPECIFICATIONS CONTRACTOR TO LINE COMPRESSOR COMPARTMENT, Q APPLICABLE PORITONS OF FAN SEC110N AND ON FILLER PANEL TO CLOSE ROOF DECK STRUCTURE L /4"W L 45' 45! CUTOUTS WITH SOUNDMAT-LF SOUND BARRIER MATERIAL INSTALLED PER MANUFACTURERS O - PIVOT (MIN.) CASTING RECOMMENDATIONS. O (/) REFRIGERANT HOT GAS LINE (TYP.) _ STRAP HANGER INSULATION SECURE UNIT TO ROOF CURB/CURB TO ROOF PER MFGR. INSTALLATION INSTRUCTIONS/STRUCT. DWGS. I� ADJUST THIS DIMENSION END VIEW SHEET METAL SHEET METAL — DAMPER ADJUSTING DAMPER © SECURE ROOF CURB TO ROOF ASSEMBLY PER MFGR. INSTALLATION INSTRUCTIONS AND -. IN FIELD AS REQUIRED ! ROD STRUCTURAL DWGS. _ RETURN BRANCH SUPPLY BRANCH _ „W DUCT A/C UNIT ROOF CURB DETAIL DUCT 1� . %, . REFRIGERANT LIQUID LINE N.T.S. (DOWNFLOW) REFRIGERANT HOT GAS LINE DUCT BRANCH TAKE OFF DETAIL INSULATION SADDLE FOR LOW PRESSURE DUCTWORK SIDE VIEW SADDLE SUPPORT N.T.S. TYPICAL REFRIGERANT PIPING HANGER DETAIL LOW VELOCITY SUPPLY BLADE LENGTH EQUAL TO 314"("D') N.T.S. AIR DUCT (SEE PLAN WITH A MINIMUM LENGTH OF 6' NOTES: 1.- PROVIDE ISOLATION BETWEEN DISSMILAR METALS VIEW) 03.28.2000 2.- PROVIDE SADDLE PROTECTION AT EACH SUPPORT MARK DIRECTION OF BLADE ON BOTH ENDS OF SQUARE BAR Revisions SPIN COLLAR FITTING WITH EXTRACTOR AND SOUND INSULATED VOLUME DAMPER, HOUSING AIR FLOW WITH QUADRANT I AIR FLOW OPERATOR TO BE OUTSIDE 18 GAGE GALV.SHEET INSULATION. PROVIDE ��p� STEEL DAMPER BLADE Project EXHAUST DUCT INSULATION GUARD �� GALVANIZED ADJUSTABLE CENTRIFUGAL WHERE NECESSARY STEEL ROD PROVIDE YOUNG No. 914 CONCEALED AIR 9933olem MOUNTING FAN INSIDE SET SCREW SPLIT REGULATOR & YOUNG NO. 301 FLANGE HOUSING CONCEALED REGULATOR WHEN NOT INSULATED FLEXIBLE DUCT SPACER REQUIRED ON ACCESSIBLE DUE TO CEILING CONSTRUCTION INSULATED DUCTS "VENTLOK" ACCESSORIES BY VENT FABRICS SEAL JOINT WITH DUCT IS AN ACCEPTABLE EQUAL. SEALER & TAPE mm(s REMOVABLE AIR FLOW ALUM. CEILING GRILLE DIFFUSER TYP. CEILING TYPE - � �-- TYPICAL DETAIL OF HORIZONTAL Sheet 6 ,.. of .7 EXH. FAN DETAIL FLEXIBLE DUCT CONNECTIONS DETAIL AIR SPUTTER DAMPER N.T.S. NTS N.T.S. }` # DETAILS i 4" Seal (AR16323,