00-0332-098 q6' I L LLJ Q) N M `� no o �lu o � a'T PACKAGED ROOFTOP A.C. UNIT SCHEDULE * w o a`�o °° AIR COOLED SPLIT A/C UNIT SCHEDULE OUTSIDE AIR CALCULATIONS (AS PER ASHRAE d2-89 m � v`z ` I UNIT DESIGNATION RTU-1 RTU-2 RTU-3 z � _o AREA SERVED 3RD FLOOR 3RD FLOOR 3RD FLOOR UNIT DESIGNATION AC-1 AC-2 AC-3 AC-4 AC-5 AC-6 AC-7 �" 3 y�'� �- NW SW EAST OFFICE OFFICE OFFICE OFFICE OFFICE 2ND FLOOR TOILET & UNIT NO. AREA AREA S/1000 P 0. OF CFM/ CFM Q2 CFM CFM ® -�` - °m i 'n z �^ SQ. FT. Q PERSONS PERSON REQUIRED PROVIDED q LOCATION SEE PLAN SEE PLAN SEE PLAN AREA SERVED 201 202 203 204 205 206 CORRIDOR „ a x N .° Mop Q OPERATING WEIGHT LBS. 579 663 858 _ �Q scz �- ELECTRICAL SERVICE AVAILABLE 08-3- 0 208-3-60 _2T8_-3-6 OPERATING WEIGHT LBS. 92 109 109 109 109 81 81 AC-1 OFFICE 815 7 20 - 115 125 ci � �' d wo YES YES DESIGN MANUFACTURER RtiEEM RHEEM RtIEEM RHEEM RHEEM RHEEM RHEEM AC-2 o N a TOTAL Al F 1700 2300 3100 MODEL NUMBER RBEA-17 RBEA-21 RBEA-21 RBHJ-21 RBHJ-21 RBEA-14 RBEA-14 OFFICE 1032 7 - 20 - 145 150 4 m� OUISIDE AIR 325 360 600 EVAP. COIL MODEL NO. RCGA-37A1 RCGA-48A1 RCGA-48A1 RCGJ36A2 RCGJ36A2 RCGA-24A2 RCBA-2453 N ~ ; NJ EXTERNAL SIATIC PRESSURE IN, QF H20 50 .50 .70 AC-3 OFFICE 1074 7 - 20 - 151 175 C � w `� -------- TOTAL AIR CFM 900 1400 1600 1300 1110 750 400 ■� o J FAN SPEED RPM 3 5-5.3 1-5.9 2-7.5 VENT AIR CFM 125 150 175 125 125 100 100 AC-4 OFFICE 864 7 20 - 122 125 o M o MAXIMUM MOTOR SPEED R.P.M. N/A N A N A EXTERNAL STATIC PRESSURE IN. OF H2O .40 .40 .40 .40 .40 .40 .25 � ° a z FAN MOTOR HP NON OVERLOAD F.L.A. 1/4-2.0 1/3-2.8 1/3-2.8 1 2-5.0 1/2-5.0 1/8-1.4 1/8-1.4 AC-5 OFFICE 830 7 - 20 - 117 125 Q- z z ELECTRICAL SERVICE 208-1-60 208-1-60 208-1-60 208-1-60 208-1-60 208-1-60 208-1-60 "®' w AC-6 OFFICE 708 7 - 20 - 100 100 o L TOTAL COOLING CAPACITY, B.T.U.H. 55,600 67,700 99,100 SMOKE DETECTORS - c � =,y TOTAL SENSIBLE CAPACITY, B.T.U.H. 3$900 50 700 69 100 0 FACE VELOCITY FPM - - - AC-7 TICORRIDOR - 300 300 100 � � � ENTERING Al R TEMP. DB WB �� 77.6/66.6 76.8/65.6 78.3/66.9 Z - - I N LEAVING AIR TEMP. DB WB o GRAND TOTAL CAPACITY BTU HR 29,800 41,000 46,500 35,800 35,800 23,600 17,200 OFFICE 1498 7 TOTAL HEATING CAPACITY, KW 9.0 6.75 13.5 v TOTAL SENSIBLE CAPACITY BTU HR 21,400 29,300 32,000 26,000 26,000 16,600 12,200 RTU-1 _ - 20 - 309 325 �� 0 j o 0 NO OF HEATING STEPS 2 1 1 - t" a w ENTERING AIR TEMP 'F DB B 76.8 65.6 76.5 65.1 76.1 64.6 76.1 64.7 76.71/65.2 76-9/65.7 79.1 67.7 OFFICE 1859 7 _ 20 - `" g o`J' _ ELEC. ELEC. ELEC. LEAVING AIR TEMP 'F DW WB - - - _ _ _ _ RTU-2 TOILETS _ - - 100 360 360 K°; a CL ELECTRICAL SERVICE 208-3-60 208-3-60 208-3-60 a TYPE AND THICKNESS DISP/1" DISP/1" DI SP/1" DISP/1" DISP/1" DISP/1" DISP/1" RTU-3 OFFICE 2745 7 - 20 - 584 600 m o or_ w TYPE THICKNESS DISP DISP 2 DISP w QUANTITY AND SIZE AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED AS REQUIRED TOILETS - - 200 z t FACE VELOCITY FPM MAXIMUM DESIGN - - - FACE VELOCITY FPM MAX QUANTITY AN SIZE AS REQUIRED AS REQUIRED AS REQUIRED REF. PIPE SIZE SUCT 1-10. 3/4-5/16 1-1/8-3/8 1-1/8-3/8 7/8-3/8 7 8-3 8 3/4-5/16 5 8-1 4 1 1 2 COIL TYPE ELEC ELEC ELEC ELEC ELEC ELEC ELEC NOTES: CAPACITY REDUCTION 100-0 100-0 100-0 ELECTRICAL SERVICE AVAILABLE 208-3-60 208-3-60 208-3-60 ,� HEAT CAPACITY KW 3.6 3.7 5.3 3.7 3.6 3.6 3.6 18.6/118 21.81L1 8 1 118fA = -" 1 1 ALL CFM AMOUNTS COUNTS ARE AS PER ASHRAE 62-19$9. N0, OF STEPS 1 1 1 1 1 1 AMBIENT AIR TEMPERATURE F 95 95 95 UNIT DESIGNATION CU-1 CU-2 CU-3 CU-4 CU-5 CU-6 CU-7 Q CFM PER URINAL OR WATER CLOSET z NUMBER OF FANS 1 1 1 o NO. OF FANS AND F.LA. 1-1.3 1-2.0 1-2.0 1-1.3 1-1.3 1-.9 1-.9 z ELECTRICAL SERVICE AVAILABLE 208-3-60 208-3-60 208-3-60 AMBIENT AIR TEMP F DB 95 95 95 95 95 95 95 O REMAINING TOILET ROOM CFM REQUIRED IS TRANSFERED FROM ADJACENT OFFICE AREAS. 8 F. A. 2.2 2.0 5.5 ~ N0. OF COMPRESSORS 1 1 1 1 1 1 1 DESIGN MANUFACTURER TRANE TRANE TRANEz ROOEE NUM TCDO60C TC0074 TCD102C COMPRESSOR RPM MAX 3500 3500 3500 3500 3500 3500 3500 TE V7E R - 10.0 10.0 - 9.2 - o°N CAPACITY REDUCTION 100-0 100-0 100-0 100-0 100-0 100-0 100-0 HOT GAS BYPASS - - - ",z COMPRESSOR F.L.A RLA 13-5/72.5 12.5/88 12.9/91 10.3177 10.3 77 10-9/54 ____83T47 w HOT GAS REHEAT - - - a z ELECTRICAL SERVICE 208-1-60 208-3-60 208-3-60 208-3-60 208-3-60 208-1-60 208-1-60 ANTI SHORT CYCLE TIMER YES YES YES TIME DELAY SEQUENCE START MULTIPLE COMP.) I YES OPERATING WEIGHT LBS. 188 193 255 188 188 155 135 a OUTSIDE AIR INTAKE W1 MANUAL DAMPER YES YES YES DESIGN MANUFACTURER MODEL NO. RAMB030JAZ RAMB042CAZ RAMB048CAZ RAM13036CAZ RAMB036CAZ RAMB024JAZ RAKA018JAZ SINGLE POINT ELECTRICAL CONNECTION YES YES YES EER/SEER -/12.40 -/12.40 -/12.40 -/12.80 7/12.80 -/12-4 -/10.0 NOTES: NOTES: 1. RTU-1,2,3 & 4 TO BE PROVIDED WITH PRE-FAB ROOF CURB,14" HIGH MIN. 1. AIR HANDLING UNITS SHALL BE PROVIDED WITH SINGLE POINT POWER CONNECTION SINGLE POINT POWER CONNECTION, ANTI-SHORT CYCLE TIMER, 0/A 2. REFRIGERANT LINE SIZES SHALL BE AS RECOMMENDED BY UNIT MANUFACTURER INTAKE W/ MANUAL DAMPER & BIRDSCREEN, TIME DELAY SEQUENCE START. FOR ACTUAL DEVELOPED LENGTH OF REFRIGERANT PIPE RUN, AND SHALL BE SUBMITTED TO ENGINEER FOR REVIEW. VENTILATION FAN SCHEDULE UNIT DESIGNATION EF-1 EF-2 EF-3 EF-4 EF 5 EF-6 ` AIR DISTRIBUTION SCHEDULE AIR CONDITIONING LEGEND > �- ELEV. CH. A SYM USE TYPE ACCESSORIES MFR & MODEL NO � Q � AREA SERVED SEE PLAN SEE PLAN SEE PLAN SEE PLAN BASEMENT SUPPLY CEILING ROUND NECK, 24X24 TITUS S Y M B 0 L W D E S C R I P T I O N R00 VENTILATION A OPERATING WEIGHT LBS. 15 25 13 36 1 AIR DIFFUSER PANEL, O.B.D. TDCA-AA AHU AIR HANDLING UNIT .� � _ 260 U SUPPLY PERF. CLG. 24X24 PANEL, ROUND TITUS BTM. BOTTOM (n LOCATION SEE PLAN SEE PLAN SEE PLAN SEE PLAN SEE LAN SEE PLAN AIR DIFFUSER NECK, O.B.D. PCS-AA COND. CONDENSATE M �-- FAN TYPE CLG. MNTD. CLG. MNTD. CLG. MNTD. IN-LINE CLG. M TD. WALL-CENT "C- RETURN RETURN 1/2 X 1/2 X 1/2 GRID, TITUS C.U. CONDENSING UNIT , AIR GRILLE 2024 LAY-IN 50F CONC. CONCRETE TOTAL AIR CFM 100 220 50 600 259 4000 RET/EXH. EXHAUST/RETURN SURFACE MOUNT, TITUS CFM CUBIC FEET PER MINUTE 0 DRIVE TYPE DIRECT DIRECT DIRECT DIRECT DIR CT DIRECT AIR REGISTER O.B.D. 4 FL E.F. EXHAUST FAN m E FAN WHEEL TYPE CENTRIF. CENTRIF. CENTRIF. CENTRIF. CEN-RIF, CENTRIF. SUPPLY CEILING ROUND NECK, PLASTER TITUS F.L.A. FULL LOAD AMPS Q) W FAN TIP SPEED,RPM MAX 2513 2113 1406 2189 299 5 3316 AIR DIFFUSER MOUNTING FRAME TDCA-AA F.P.M. FEET PER MINUTE U Q� FAN SPEED,RPM 1500 1538 956 1325 150110 517 1/2 X 1/2 X 1/2 RETURN RETURN GRID, H.P. HORSEPOWER `'- > 0 4 - ' TOTAL STATIC PRESSURE,IN. OF I120 .25 .125 .125 .250 .12 .25 'F" SIZE AS INDICATED ON TITUS AIR GRILLE 50F H.R. HOUR O u- FAN MOTOR HP NON OVERLOAD 63 WATTS 109 WATTS 14 WATTS 1 4 1 1 1 2 Pte' IN. INCH O C) FAN MOTOR STARTER TYPE - - - - - - SUPPLY VAV CEILING 2024 PANEL ACUTHERM STARTER FURNISHED BY - - - - - - AIR DIFFUSER RELIEF RINGS TF-HC K•W. KILOWATT ELECTRICAL SERVICE AVAILABLE 120-1-60 120-1-60 120-1-60 120-1-60 120-1-60 120-1-60 LBS. POUNDS z SUPPLY VAV CEILING ACUTHERM MAX. MAXIMUM MASONRY OPENING REQUIRED - - - - - VERIFY �� AIR DIFFUSER RELIEF RINGS TN-C MVD MANUAL VOLUME DAMPER (OPPOSED BLADE) T DESIGN MANUFACTURER COOK COOK COOK COOK COOK COOK N 0. NUMBER 0 D NOTE: O MODEL NUMBER GC-140 GC-340 GC-120 GN-720 GC 180 245W56 0/A OUTSIDE AIR - 1. AIR DISTRIBUTION SHALL BE OF EXTRUDED ALUM. CONSTRUCTION. 0 SERVICE SWITCH YES YES YES YES ES YES 2. PROVIDE INSULATED BACKING FOR SUPPLY AIR DIFFUSERS TO PREVEVT CONDENSATION, RPM. REVOLUTIONS PER MINUTE SMOKE DETECTORS - - - - R/A RETURN AIR w FIRE DAMPER - - - REF. REFRIGERANT _ � CONSTRUCTION STEEL STEEL STEEL STEEL STEEL ALUMINUM MULTIBLADE BACKDRAFT DAMPER YES YES YES YES ES YES RTU. ROOFTOP UNIT - BIRDSCREEN - - - - YES S SUPPLY AIR SOLID STATE SPEED CONTROL - YES YES - YES TEMP. TEMPERATURE AIR DISTRIBUTION DESIGNATION TAT CONTROL - e - - - ES - HVAC DESIGN REQUIRES: YES NO / QT ' THERMOSTAT FACTORY FABRICATED CURB MODEL N0. - - _ - - - - SONES 3.1 �4.0 1,2 3.5 5. 7.7 -------- DUCT SMOKE DETECTOR I>< SUPPLY OR OUTSIDE AIR DUCT SECTION NOTES: FIRE DAMPER(S) EXHAUST OR RETURN AIR DUCT SECTION 1. ALL FANS SHALL BE AMCA CERTIFIED. SMOKE DAMPER(S) -'� OPPOSED BLADE MANUAL VOLUME DAMPER 2. EF-1,3 SHALL BE PROVIDED WITH TIME DELAY SWITCH & DELUXE ALUMINUM GRILLE. -• SIDEWALL REGISTER WITH AIRFLOW ARROW FIRE RATED ENCLOSURE �'� L `� CEILING DIFFUSER WITH AIR FLOW ARROW 3. EF-1,3 SHALL BE INTERLOCKED W/LIGHT SWITCH. FIRE RATED ROOF/FLOOR IA.Q. SOUND LINING CEILING ASSEMBLY ELBOW UP (SUPPLY OR OUTSIDE AIR) FIRE STOPPING �,., ELBOW DOWN (SUPPLY OR OUTSIDE AIR) 3.Z 8.2 SMOKE CONTROL �--�� ELBOW UP (RETURN OR EXHAUST AIR) ' ELBOW DOWN (RETURN OR EXHAUST AIR) Revisions 9(7 ELBOW W/TURNING VANES A BL5-03-00 DG. PT. COMMENT VWN" FLEXIBLE DUCT (INSULATED R-6 MIN.) S ' DUCT MOUNTED SMOKE DETECTOR �-� UNDER CUT Project 9933alem Mol M CHAI�IICAL MOTES AND SCHEDULES Sheet 1 of 7 r , IL fit r E ;�= ., . .�_. Cl 0 Seal (AR 1 6320` 7 .T ! .