Loading...
00-0332-080 '-U C>- y N t� + PLUMBING LEGEND PLUMBING GENERAL NOTES PLUMBING SPECIFICATION _ ° �' E - PLUMBING FIXTURE CONNECTION SCHEDULE ,o G 93 ` ol u (0 V) � 40 � � � i � o v I E COLD HOT BAN SANITARY DRAIN A. UNLESS OTHERWISE SPECIFIED ON THIS DRAWING CONTRACTOR SHALL 1. GENERAL: SYMBOL DESCRIPTION DRAIN WATER WATER MANUFACTURER/MODEL TRIM BAN EX1871NG SANITARY DRAIN REFER TO ORIGINAL LANDLORD SPECIFICATIONS FOR ALL APPLICABLE L m ° z 3 �° REQUIREMENTS, NOTES, DETAILS, CONSTRUCTION'S STANDARDS, ETC., MATERIAL SHALL BE NEW, UNUSED, BEST OF THEIR RESPECTIVE KINDS AND C E V) a V SANITARY VENT LINE COORDINATE WITH LANDLORD REQUIREMENTS PRIOR TO ORDERING AND/OR FREE FROM DEFECTS IN WORKMANSHIP; IN CONFORMANCE WITH THE LATEST 9, Y 9 z E ,j v - -' - -' INSTALLATION OF ANY EQUIPMENT AND ACCESSORIES SHOWN. PUBLICATIONS IN FORCE AT TIME OF BIDDING. z �+ } ,� 0 N 00 a P-1 WATER CLOSET 3" 1/2" -- AMERICAN STANDARD "CADET 11" FLUSH: TANK SYSTEM PROVIDED WITH FIXTURE. - - - "� V EXISTING SANITARY VENT LINE 1. SITE INVESTIGATION: 2. PIPE AND FITTINGS: a Q o°? 1- � mac° #2174.139, WHITE 1.5 GPF SEAT: OLSONITE #46 OPEN FRONT SEAT WITH COVER. A. SANITARY SOIL AND VENT PIPING: SERVICE WEIGHT CAST IRON BEEL 8 ELONGATED SIPHON ACTION BOWL SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE SD Sp St01�`1 DRAIN FLOOR MOUNTED WITH CLOSED- KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK; THE BIDDER IS AND SPIGOT PIPE AND FITTINGS, ASTM.A74-75: NO HUB CAST IRON PIPE a W COUPLED SIDE TRIP LEVER FLUSH COPPER CONNECTION. 3D SD EXISTING STORM DRAIN REQUIRED, BEFORE SUBMITTING HIS PROPOSAL, TO VISIT THE SITE OF THE AND FITTINGS, CISPI. 301-72, OD DWV. COPPER PIPE WITH CAST BRASS OR CO PROPOSED WORK AND FAMILIARIZE HIMSELF/HERSELF WITH THE NATURE AND WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM. B306-79, (ABOVE GROND) TANK AND BOLT CAPS. IW INDIRECT WASTE (SAFEWASTE) EXTEND OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER VENTING AS HERIN BEFORE SPECIFIED OR GALVANIZED THREADED STEEL WITH a, 3 Q AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR MALLEABLE IRON FITTINGS. IW EXISTING INDIRECT WASTE (SAFEWASTE) REQUIRED THEREFORE. SINCE THE WORK INVLOVES EXISTING BUILDINGS, SYSTEM B. DOMESTIC WATER SUPPLY PIPING: COPPER PIPE TYPE 'L' WITH BRONZE ° P-1H WATER CLOSET 3" 1/2" -- AMERICAN STANDARD "CADET II" FLUSH: TANK SYSTEM PROVIDED WITH FIXTURE. c ND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF #2216.170, WHITE 1.5 GPF SEAT: OLSONITE #46 OPEN FRONT SEAT WITH COVER. CO CD CONDENSATE DRAIN LINE WORKING CONDITIONS, EXISTING FACILITIES AND ALL BUILDING STRUCTURES OR WROUGHT COPPER SOLDER JOINT FITTINGS, ASTM.B88-78. _ z ELONGATED SIPHON ACTION BOWL SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE C GD EXISTING CONDENSATE DRAIN LINE TO FAMILIARIZE HIMSELF WITH ALL EXISTING CONDITIONS. VARIATIONS IN C. CONDENSATE PIPING: AS HEREIN BEFORE SPECIFIED FOR SANITARY Q FLOOR MOUNTED WITH CLOSED- ROUTING AND/OR CONSTRUCTION SHOULD BE ANTICIPATED BY THIS Ca � � KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID 501E WASTE AND VENT PIPING. Pt7 PTR PRESSURE AND TEMPERAIURE RELIEF LINE CONTRACTOR AND ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER �_ R � COUPLED SIDE TRIP LEVER FLUSH COPPER CONNECTION. REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART 3. JOINTS AND METHODS OF CONNECTION: _ � a ? TANK AND BOLT CAPS. Pat PTR PRESSURE MID TEMPERATURE RELIEF LINE OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATION AND M RESPONSIBILITIES ASSUMED UNDER THIS CONTRACT. A. CAST IRON BELL AND SPIGOT PIPE: COMPRESSION GASKET. INSTALL PER W m w V" Cs G GAS LINE MANUFACTURER'S RECOMMENDATION. GASKET AND PIPE BY SAME MANUFACTURER. J o °z 2. THE NATURE OF THE REMODEL TYPE CONSTRUCTION POSES SPECIAL 1=° -t:'c cn P-2 LAVATORY 1 1/4" 1/2" 1/2" AMERICAN STANDARD "AQUALYN" FAUCET: DELTA #2520-MPU, TWO HANDLE 4' CENTERSET G GAS LINE B. DWV COPPER PIPE: JOINT WITH 95-5 TIN-ANTIMONY SOLDER INSTALL g o w ° z PROBLEMS FOR THE DESIGN ENGINEERS AS WELL AS THE PLUMBING #0476.028, WHITE VITREOUS LAVATORY FAUCET, POLISHED CHROME BRASS FITTING CONTRACTOR. EVERY EFFORT HAS BEEN MADE BY THE ENGINEERS TO SHOW AND PER MANUFACTURER'S RECOMMENDATIONS. , t A 0 CHINAL SELF-RIMMING LAVATORY WITH BLADE HANDLES AND METAL POP-UP. PROVIDE -' CW COLD WATER LINE IDENTIFY THE LOCATIONS AND TYPES OF EXISTING PLUMBING SYSTEMS. THE C. TYPE 'L' COPPER TUBE: JOIN WITH 95-5 TIN-ANTIMONY SOLDER, INSTALL Olf WITH 4" CENTER FAUCET HOLES WITH 0.5 GPM PRESSURE COMPENSATING FLOW CONTROL - CW COLD WATER LINE MAJOR PORTION OF THE PLUMBING SYSTEMS ARE AS SHOWN ON THE DRAWINGS PER MANUFACTURER'S RECOMMENDATIONS. N v'-'-', AND FRONT OVERFLOW. OUTLET. HOWEVER DEVIATIONS MAY BECOME EVIDENT AS THE JOB PROGRESSES. 1 z UJ DRAIN: POP-UP DRAIN SUPPLIED WITH FAUCET AND -- Hill HOT WATER LINE PLUMBING CONTRACTOR SHALL PERFORM A FIELD VERIFICATION BEFORE D. STEEL PIPE: ti McGUIRE #8872 P-TRAP WITH CLEANOUT PLUG AND BIDDING THIS PROJECT. a. THREADED JOINTS: AFTER CUTTING AND BEFORE THREADING, REAM ESCUTCHEON. - - HW HOT WATER LINE ALL PIPE AND REMOVE BURRS. MAKE JOINTS WITH JOINT COMPOUND APPLIED SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE 3. CONTRACTOR WILL BE RESPONSIBLE FOR COODINATING HIS DEMOLITION TO MALE THREADS ONLY. KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID HWR HOT WATER RECIRCULATING LINE WORK WITH OTHER TRADES, AND TO PROTECT FROM DAMAGE EXISTING SYSTEMS b. FLANGED JOINTS: STANDARD WEIGHT, 150 P.S.I. STEEL, WITH APPROVED COPPER CONNECTION. - - - HWR HOT WATER RECIRCULATING LINE TO REMAIN. RED RUBBER GASKET OR NEOPRENE RUBBER GASKET, INSTALL AS PER MANUFACTURER'S RECOMMENDATIONS. P-2H LAVATORY 1 1/4" 1/2" 1/2" AMERICAN STANDARD "LUCERNE" FAUCET: DELTA 2520-MPU, 4. CONTRACTOR SHALL VERIFY THE EXACT LOCATION OF EXISTING PIPES TWO HANDLE 4" CENTERSET GV GATE VALVE BEFORE COMMENCING TO WORK AND MAKE MODIFICATIONS AS REQUIRED 4. UNIONS AND FLANGES: (HANDICAP) #0355.012, WHITE VITREOUS CHINA LAVATORY FAUCET POLISHED CHROME BRASS FITTING WITHOUT ADDITIONAL COST TO THE OWNER. WALL HUNG LAVATORY WITH 4" WITH BLADE HANDLES AND METAL POP-UP. PROVIDE v �- CV CHECK VALVE A. COPPER PIPE: BRONZE UNIONS FOR 2 INCHES AND SMALLER. FOR 2-1/2 CENTER FAUCET HOLES AND WITH 0.5 GPM PRESSURE COMPENSATING FLOW CONTROL BALANCING VALVE 5. ALL PIPING SHALL BE INSTALLED RECESSED IN BLOCK WALLS, CHASES INCHES AND LARGER USE BRONZE FLANGED CONNECTIONS 150 POUND CLASS. CENTER OVERFLOW. OUTLET. OR PARTITIONS. DRAIN: POP-UP DRAIN SUPPLIED WITH FAUCET AND HS HOSE BIBBIU/ VACUUM BREAKER UNIONS UNIONS SHALL MEET DIMENSIONAL 6. EXISTING PIPES SERVING AREAS NOT COVERED BY THIS CONTRACT BUT REQUIREMENTS AND TENSILLE STRENGTH OFPIPEUNIONS IN ACCORDANCE WITH McGUIRE #8872 P-TRAP WITH CLEANOUT PLUG AND T AC AIR CHAMBER IN SERVICE AT THIS TIME SHALL NOT BE INTERRUPTED EXCEPT AS A FED. SPEC. WW-U-531E. UNIONS OR FLANGES SHALL BE SUITABLE FOR CARRIER: ZURN Z-1231 SERIES ESCUTCHEON. TEMPORARY INTERRUPTION COORDINATED WITH THE OWNER AND LANDLORD. REQUIRED OPERATING PRESSURES AND TEMPERATURE CONDITIONS. UNIONS # SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE SA SHOCK ARRESTOR (P.D.I. SIZE 'A' SHALL HAVE METAL CONNECTIONS ON BOTH ENDS. ENDS SHALL BE THREADED KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID TYPICAL UNLESS NOTED OTHERWISE.) 7. PLUMBING CONTRACTOR SHALL PAY ALL FEES, INSPECTION AND OR SOLDERED TO MATCH ADJACENT PIPING. METAL PARTS OF UNION OR COPPER CONNECTION. CONNECTION CHARGES REQUIRED. FLANGED SHALL BE SEPAREATED TO PREVENT CURRENT FLOW BETWEEN INSULATION: TRUEBRO MODEL #102W WITH ACCESSORY -�I CO GLEAN•OU7 PLUG DISSIMILAR METALS. EPCO DIELECTRIC PIPE FITTINGS OR EQUIVALENT. #105W, WHITE OFFSET DRAIN PIPE INSULATION WITH 8. PLUMBING CONTRACTOR SHALL VERIFY ALL SPACE CONDITIONS AND II WCO WALL CLEAN-OUT DIMENSIONS AT JOB SITE PRIOR TO FABRICATION AND INSTALLATION OF 5. ESCUTCHEONS: HOT AND COLD WATER SUPPLY INSULATION COVERS. 8 CNTE CONNECT TO EXISTING MATERIALS AND EQUIPMENT. CHROME PLATED OR STAINLESS STEEL WITH SET SCREWS FOR HOLDING P-3H URINAL (HANDICAP) 2" 3/4" -- AMERICAN STANDARD "ALLBROOK" FLUSH: ZURN #Z-6003XL-WSI, EXPOSED POLISHED ® FD FLOOR DRAIN 9. COORDINATE ALL WORK WITH OTHER TRADES. SECURELY IN PLACE. USE ESCUTCHEONS ON PIPES PASSING THROUGH WALLS, #6541.132, WHITE VITREOUS CHINA CHROME BRASS 1.0 GAL. PER FLUSH VALVE WITH FLOORS AND CEILINGS OF FINISHED AREAS. VTR VENT THRU ROOF 10, PLUMBING CONTRACTOR SHALL GUARANTEE ALL WORK FREE OF DEFECTS IN WALL HUNG URINAL WITH TOP LOW FORCE LEVER HANDLE AND VANDAL-RESISTANT AP ACCESS PANEL MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM DATE OF 6. PIPE INSULATION: SPUD. STOP COVER. FOS FUEL OIL SUPPLY ACCEPTANCE. FOR FUEL OIL RETURN A. ALL CONDENSATE LINES SHALL BE INSULATED WITH 3/4" FIRE RETARDANT 11, PROVIDE SHOCK ABSORBERS SIZE, QUANTITY AND LOCATION AS PER ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE FOV FUEL OIL VENT DEVELOPED RESPECTIVELY. / - CARRIER: ZURN #Z-1231 SERIES CO CLEAN OUT P.D.I. STANDARDS. WCO WALL CLEAN OUT 12, PROVIDE SHUT-OFF VALVE FOR EACH GROUP OF FIXTURE AND EACH B. ALL HOT WATER LINES SHALL BE INSULATED WITH 1" FIRE RETARDANT Q) FCO FLOOR CLEAN OUT FIXTURE SUPPLY. ARMAFLEX INSULATION WITH A MAXIMUM OF 25/50 FLAME SPREAD AND SMOKE U > - CTG CLEAN OUT TO GRADE DEVELOPED RESPECTIVELY. Q (� DELTA #1424-LHP, POLISHED CHROME BRASS BODY FDC FIRE DEPT. CONN. (SIAMESE) 13, WHEREVER DISSIMILAR METALS ARE TO BE JOINED A DIELECTRIC PRESSURE BALANCE VALVE WITH LEVER HANDLE, 2.5 GPM FH FIRE HYDRANT FITTING SHALL BE PROVIDED TO CONNECT BOTH TYPES OF PIPES. 7. INSTANT WATER HEATERS SHALL BE OF THE CAPACITY AND ELECTRICAL __J TOUCH-CLEAN SHOWERHEAD AND SCREWDRIVER STOP. FHC FIRE HOSE CABINET P-4H SHOWER 2" 1/2" 1/2" SEE ARCHITECTURAL DRAWINGS CHARACTERISTICS INDICATED ON PLANS AS MANUFACTURED BY INSTAHOT. 4_1 PROVIDE WITH #190253A DIVERTER VALVE AND #RPW1111HDF FVC FIRE VALVE CABINET W/ HFV 14. CONTRACTOR SHALL BE RESPONSIBLE TO COORDINATE ALL ROUGH-INS (HANDICAP) PERSONAL SHOWER WITH 24" VERTICAL BAR, 60" HOSE, FEC FIRE EXTINGUISHER CAB. W/ FE WITH THE MANUFACTURER BEFORE MAKING ANY INSTALLATION. 8. TRAP PRIMERS: VACUUM BREAKER AND WALL SUPPLY ELBOW. FE FIRE EXTINGUISHER FE/CO FIRE EXT./CARBON DIOXIDE 15. POTABLE HOT AND COLD WATER SYSTEMS SHALL BE "LEAD FREE' WITH A. REMOTE LOCATION: SELF PRIMING TYPE ON COLD WATER SUPPLY LINE C -I--� • 0 WH WATER HEATER P-5H WATER COOLER 1 1/4!' 1/2" -- ELKAY MODEL #EBFSA-8, DRAIN: McGUIRE 8872 POLISHED CHROME CAST UG UNDER GROUND PER°ENOTNFORT PIPE FITTINGS,FIXTURESR AND TTR M CONTRACTOR SHALLS AND 8 AS MANUFACTURED BY PRECISION PLUMBING PRODUCTS, INC. "PRIME-RITE" 'D # D DISTRIBUTION UNIT WHEN TWO #DUO-2 3 OR MORE 4 AND SUPPLY Y PRIMING, UBE #SS PROVIDE ASSEMBLY. ': 0 BARRIER-FREE ELECTRIC WATER BRASS P-TRAP WITH WALL BEND, CLEANOUT PLUG, DIP DUCTILE IRON PIPE VERIFY MANUFACTURER'S COMPLIANCE. COOLER. SLIP NUTS AND SHALLOW ESCUTCHEON. CMP CORRUGATED METAL PIPE PROVIDE ACCESS PANEL AND INSTALL PER MANUFACTURER'S RECOMMENDATION. m SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE CIP CAST IRON PIPE 16. ALL POTABLE HOT AND COLD WATER SYSTEMS SHALL BE FLUSHED CLEAR, STERILIZED WITH AN APPROVED SOLUTION AND THROUGHLY FLUSHED OF ALL B. TOILET ROOMS: KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID TP TRAP PRIMER (RESEALER) RESIDUAL SOLUTION AFTER FINAL PRESSURE TESTS AND WITH ALL TRIM AND Q) COPPER CONNECTION. A/C AIR CONDITIONER CONTRACTOR SHALL PROVIDE ALL REQUIRED TRIMS TH THERMOMETER CONNECTIONS INSTALLED. a. FLUSH VALVE: DELANY #T38 TRAP PRIMER ATTACHMENT IN FLUSH U 0 CONNECTION. AND CONNECTIONS AS PER MANUFACTURER'S FHV FIRE HOSE VALVE 17. PROVIDE SHUT-OFF AND VACUUM BREAKER TO ALL HOSE BIBBS AND `+-- RECOMMENDATIONS TO MAKE FIXTURE OPERATIONAL. 0 AHU AIR HANDLING UNIT FAUCETS WITH HOSE-END CONNECTIONS. b. SINKS/LAVATORY: JOSAM #88250-10, POLISHED CHROME PLATED 0 C- N CLG CEILING TRAP SEAL PRIMER VALVE ON COLD WATER SUPPLY LINE. C UG UNDERGROUND 18. ALL FLOOR DRAINS SHALL HAVE TRAP PRIMERS TO PROTECT THE SEAL OF r-", • - P-6 LOUNGE SINK 1 1/2" 1/2" 1/2" KINGSFORD MODEL #KF-12522, FAUCET: DELTA #2100, POLISHED CHROME 8" CENTER THE TRAP. 9. FLOOR DRAINS: AS MANUFACTURED BY ZURN, J.R. SMITH OR JOSAM. Q) • - SINGLE COMPARTMENT STAINLESS DECK MOUNT FAUCET WITH BLADE HANDLES, 8" LONG 19. PVC PIPING IS NOT ALLOWED IN RETURN AIR PLENUMS. IF RETURN AIR A. FD: JOSAM 30003-S SERIES WITH 6"x6" SQUARE NIKALOY TOP AND 1/2" Z STEEL SINK WITH THREE FAUCET SPOUT AND 2.0 GPM OUTLET. HOLES. DRAIN: McGUIRE #151, POLISHED CHROME BRASS PLENUMS ARE USED, CONTRACTOR SHALL REPLACE ALL EXISTING PVC PIPING WITH TRAP PRIMER CONNECTION.BASKET STRAINER WITH 1 112" X 4' TAILPIECE. CAST IRON OR COPPER PIPING. Q 4-J McGUIRE #8912 POLISHED CHROME CAST BRASS 20. DRAINAGE SYSTEM DESIGN IS BASED ON 1/8" PER FT. MINIMUM FALL, ANY FOR 0 P-TRAP WITH WALL BEND, CLEANOUT PLUG, SLIP PIPES 3" OR LARGE AND 1/4" PER FOOT MINIMUM FALL FOR PIPES 2" OR 0 NUT AND SHALLOW ESCUTCHEON. SMALLER, ANY DEVIATIONS SHALL BE APPROVED BY ARCHITECT/ENGINEER. 0 SUPPLY: BRASS-CRAFT ANGLE SUPPLY WITH LOOSE KEY STOP, SHALLOW CHROME ESCUTCHEON AND RIGID 21. ALL VENT THROUGH ROOF OPENINGS SHALL BE OFFSETED TO A MINIMUM 0 COPPER CONNECTION. DISTANCE OF 3'-0" FROM PARRAPET WALL OR ROOF EDGE. SEE ARCHITECTURAL DRAWINGS FOR ROOF FLASHING. LEAD FLASHING WILL NOT BE ACCEPTED. P-7 MOP SINK 3" 1/2" 1/2" FIAT #TSB-3000, 24x24x12 FAUCET: SPEAKMAN "COMMANDER" TERRAZZO MOP BASIN WITH #SC-581 1-4WH, POLISHED CHROME CAST CONTINUOUS STAINLESS STEEL BRASS FITTING WITH 1/4 TURN VANDAL CAPS ON ALL CURBS AND RESISTANT 4" WRIST BLADE HANDLE REMOVABLE STAINLESS STEEL CARTRIDGES, INTEGRAL STOPS, BRASS STRAINER. VACUUM BREAKER, 3/4" THREADED HOSE COUPLING DISCHARGE, PAIL HOOK AND TOP BRACE ASSEMBLY WITH WALL FLANGE AND MOUNTING SCREWS. PROVIDE WITH OMNI 2.0 GPM PRESSURE COMPENSATING FLOW CONTROL. ACCESSORIES: #832-AA, 30" RUBBER HOSE WITH 314" BRASS COUPLING AT ONE END AND STAINLESS STEEL BRACKET WITH RUBBER GRIP. #833-AA, SILICONE SEALANT. WATER HEATER SCHEDULE REF REFRIGERATOR -- 1/2" -- SEE ARCHITECTURAL DRAWINGS CONTRACTOR SHALL PROVIDE ALL REQUIRED TRIMS AND CONNECTIONS AS PER MANUFACTURERS GAL. RECOV.@ ELECTRICAL FUEL/BTUH 03.28.2000 RECOMMENDATIONS TO MAKE FIXTURE OPERATIONAL. SYMBOL SERVICE CAP. 10(9 RISE REQUIREMENTS REQUIREMENTS MANUFACTURERIMODEL Revisions EWH WALL HUNG 40 12 208V., 1 PH. --- A.O. SMITH MODEL DEL-40 4500 WATTS EF=.89 Project 9933alem PIN Sheet ,,, ? .of 1 PLUMBING NOTES, SCHEDULES AND SYMBOLS !''►i + J f5 4 Sea (AR 1 632.Q)