00-0332-041 0 03. 1 2.2001 .
Updated site info \�o U 0.
N O 4
List of Drawings Site Information
r E
co W 70th _ A0.00 Cover Page Site Data 7000 SW 61 Avenue z �
i�_ y 5
i S Street i �4��
Landscape Documents South Miami , Florida
La
® L1 .0 Landscape Plan Lot Size (Minus Zoned R/W) 12,762.3 s.f. La
Lot Size With Zoned R/W Area 13,434.0 s.f.
Civil Engineering Documents
C1 .01 Utility/Drainage plan & details 4 Lot Frontage 100'
a, C1 .02 Drainage/landform detail ® ® Q
Zoning Designation MO
C c C1 .03 Trench information/details
Q Q -SW 71st Street C1 .04 Water main extention info. Use Medium-Intensity Office Building
u Maximum Allowable Impervious Lot Coverage 85% = 10,848 s.f.
Architectural ocuments
A2.01 Site Plan - Parking Level 1 Plan Proposed Lot Coverage 10,309 s.f.
Ln cn A2.11 Parking Level 2 Plan Maximum Allowable Gross Square Footage 1 .60 = 20,420 s.f.
A2.21 Third Floor Plan
A2.31 Fourth Floor Plan Proposed Square Footage
A2.41 Roof Plan (W
A5.01 Elevations Itemized o
� A5.02 Elevations
Parking Level 1 79 s.f.
A5.04 Building Sections Parking Level 2 337 s.f. 7—
A6.21 P1 and P2 Reflected Ceiling Plan Sketch Building Perspective
- Sunset SW 72nd Street Drive - - - - Third Floor 5,948 s.f.
( ) A6.31 Third and Fourth Floor Reflected Ceiling Plan W
A7.01 Enlarged Bathroom Plans, Sections and Details Fourth Floor 6,249 s.f.
A7.11 Enlarged Stair Plans, Sections
Total 12,613 s.f.
A7.12 Stair Details
A7.21 Enlarged Elevator Plan, Details and Sections Required Parking Spaces 50 spaces (1 per each 250 s.f.)
NT Location Plan A9.04 Office Detail Plan - Fourth Floor AlemiBuilding
Proposed Parking Spaces
Not to Scale
Fire Protection Documents Itemized 7000 S W 61st Avenue
F1 Fire Protection Notes and Details Street-side Metered Parking 3 Spaces
F2 P1 Fire Protection Plan South v l a m l � o ri d a 33143
�
F3 P2 Fire Protection Plan Parking Level 1 24 Spaces ,
F4 Third Floor Fire Protection Plan Parking Level 2 23 Spaces d
F5 Fourth Floor Fire Protection Plan
Total 50 Spaces >
Designated Handicapped Parking 2 Spaces Owner:
Structural Documents O +J
S1 Foundation and Ground Floor Plan Required Setbacks Alemi's Investments, LLC
S2 Parkin Level 2 Framing Plan 7380 SW 48th Street -
g g Front Side (East) 15 (Ground Floor Only) Miami, Florida 33155
S3 Third Floor Framing Plan — � o
S4 Fourth Floor Framing Plan Interior Side (South) 0' 305 661 9211 tel _
305 668 8872 fax
S5 Roof Framing Plan Street-side (North) 10' m (� U/
S6 Sections and Details QD
S7 Sections and Details Rear (West) 10' U > o
S8 Sections and Details Proposed Setbacks Architect: O E N E
Front Side (East) 15'
S9 Sections and Details Maidique Design & Build Company
S10 Sections and Details 3139 SW 27th Avenue
Interior Side (South) 5' Suite 5 z
Plumbing Documents Street-side (North) 11 4 Miami, Florida 33133 Q)
— -+-�
P1 Plumbing Notes, Schedules and Symbols 305 444 2775 tel Q O
P2 P1 Plumbing Plan Rear (West) 10' 305 444 2069 fax o 0
P3 P2 Plumbing Plan (n
Maximum Allowable Building Height 4 Floors or 50 0
P4 Third Floor Plumbing Plan
P5 Fourth Floor Plumbing Plan Proposed Building Height 3 Floors, 50' High Structural Consultants:
P6 Roof Plumbing Plan Utilities: Count
P7 Plumbing Schematic Water Riser Diagram y /Water Sewer Available at Site
G. V. Pirez Associates, Inc.
P8 Sanitary and Storm Drain Riser Diagram Electrical Service Available at Site Consulting Engineers
1385 Coral Way
P9 Plumbing Details Fire: Hydrant on Adjacent Block. Entire Building to be Sprinkled. Suite 202
P10 Plumbing Details Miami, Florida 33145-2941
Landscape Required 15% x 12,762.3 s.f. = 1 ,914.4 s.f.
305 854 4104 tel
Landscape Provided 2434 s.f. 305 856 2076 fax
Mechanical Documents
M 1 Mechanical Notes and Schedules
M2 P1 Mechanical Plan Mechanical, Electrical & Plumbing
M3 Third Floor Mechanical Plan
M4 Fourth Floor Mechanical Plan Gartek Engineering Corporation 0 1 . 1 5.2000
M5 Roof Mechanical Plan 7210 SW 39th Terrace
Revisions
M6 Details Miami, Florida 33155
M7 Details 305 266 8997 tel 03. 12.2001
Legal Description 305 264 9496 fax
Electrical Documents Legal description lots 11 and 12 block 2 of the "Rosswood" Subdivision, Project
E1 Electrical Notes and Symbols Landscape 9933clem
E2 P1 Electrical Plan according to the plat thereof as recorded in plat book 13 at page 62
Maidique Design & Build Company
E3 P2 Electrical Plan of the public recors of Dade County, Florida. 3139 SW 27th Avenue
E4 Third Floor Lighting Plan
Suite 5
E5 Third Floor Electrical Plan Miami, Florida 33133 A0n00
E6 Fourth Floor Lighting Plan
E7 Fourth Floor Electrical Plan 305 444 2775 tel
305 444 2069 fax
E8 Roof Electrical Plan
E9 Electrical Details
Sheet 1 of —
E10 Schedules and Notes
E11 Electrical Panel Diagrams o�,,;`_,
s E12 Electrical Riser Diagrams
• ^ a
of
Sea; (AR 1 6320)
:Z