00-0332-031 t M ' v 0 °� nw N t�� O cp0 am t` °O Q•.O qtr' t7 00 r..� w U O $ c ap .0 .b::f'% Lo- N to FACE OF WALL — — Y m ; z' ^t� a° m F�i•••.•.. a $ Q.: .� p E O.. }` a NUT 0 c STAINLESS STEEL COVER Y � ° CLEVIS RANGE ---STAINLESS TO THREADED � 0 PIPE O.D. ,` C .O. PLUG INSULATION O.D. _ 3 PIPE GRATE aC o J 44 Q_ INSULATION "ZURN" #Z-1446—BP—VP 4) tii FOR EXPOSED BLOCK AND 83 a z z GYPSUM BOARD WALLS. _ + + "ZURN" #ZN-1447—BP—VP FOR TILE WALLS WALL "ZURN" #ZN-1448-BP-VP D °C�U CHECK VALVE L' 9 J SADDLE FOR PLASTER WALLS W g' i", °� ALV. SHIELD o °C UNION GATE VALVE W FUSED DISCONNECT 1 1/2" TO DRAINAGE a Ln PIPE PIPE "ZURN" CONCRETE PAD "ZURN" SWITCH IN DRY AREA a SYSTEM a #Z-1404—VP � < 3 W W/ INSULATION W/OUT INSULATION #ZN-1400—BP—T—VP 2 x 2 x 8 W/ IRON BOX WITH COVER ° o W FLOOR CLEANOUT 4t 3EW MARKED "C.O." GROUNDED PLUG PIPE HANGERS-CLEVIS TYPE DETAIL 18 X 18 X 18" N.T.S. SUMP PIT IN ELEVATOR. FIN. GRADE 24 X 24 X 24" CATCH BASIN ON TRENCH DRAIN. DRAIN STRAINER "INVERTA-COLLAR" 1/2" TRAP PRIMER FLUSH WITH (SHOWN IN LOW CONNECTION k �� FINISH FLOOR POSITION) � ADJUSTABLE FILL VOIDS MICRO PRESSURE SWITCH jLJ °C DRAIN HEAD SECTION VIEW WITH OILED WITH ADJUSTABLE CLAMP FOR CLARITY COMPACTED FILL SANDG MEMBRANE FLASHING �' '�' ` '�� a• �_ �• CLEANOUT FITTING VENTED CABLE FLANGE W/ BRASS PLUG 4• � r ,- ELEVATION VIEW PP MICRO PRESSURE t� O SWITCH �UCDU 1 1/2" DISCHARGE •�1I�i •.:� :: •.: �:: i.�I�� � OcO00C0 00000 CAST IRON DRAIN TAILPIECE TO SUBMERSIBLE SUMP PUMP DRAIN BODY P—TRAP. SEE PLANS STRAINER (INSIDE CAULK ILLUSTRATED) FOR SIZE. FLOOR TWO—WAY CLEANOUT TO GRADE TEE OR LONG SWEEP ZURN #ZN-415-6SH—P—Y QUARTER BEND. SUMP PUMP DETAIL NOTE: REFER TO SPECIFICATIONS FOR MATERIALS N.T.S. :3: AND REQUIREMENTS FOR INSTALLATION. TYPICAL FLOOR DRAIN (FD) DETAIL U > N.T.S. CLEANOUT DETAILS N.T.S. PL13G-21 C 0 4� 1 or 2 Hour Fire Rated Through S—L y S i f; g 1-1/2 & 2 Hour Fire Rated Through 2 and 4 Hour Fire Rated Through •– C- 6 a Pe netration Firesto for Sin le `as S,r; .. :...........p g o °d Penetration Firestop for Insulated s I f G�a� "a Penetration Firestop for Single .Metal Pipe through 3735 Green Rd. Metal Pipe through Concrete 373s Green Rd. Metal Pipe through m 3735 Green Rd. E y8 t eo Gypsum Walls using Beachwood,OH,44122 sye t� Floors or Walls using Beachwood,OII,44122 Concrete Floors or Walls FYRE-SHIELD. FYRE-SIL and FYRE-SIL S/L. s ® Beachwood,OH,44122 (n Drawing not to scale .Ys t ed` using FYRE-SIL. U • = WL 1097 F-Rating= 1 and 2 Hr. F-Rating= 1-1/2 & 2 Hour Drawing not to scale Drawing not to scale 4- O CAJ 5067 T-Ratio – 1/2, 1 & 1-1/2 Hour CAJ 1064 F-Rating=2 and 4 Hr. g O C N T-Rating= 0 Hr. g T-Rating=0 Hr. 2 — O •� 4 4 1 z E 2 � °6C a a Q � a: 4 O Poe 0 p a d p 4 a O . . a All Q Pre-Rated Concrete Floor or Wall Assembly=Min. 4-1/2" thickness lO 0 Metallic Pipe: > Steel Pipe - 10 Pre-Rated Concrete Floors or Block Walls: See Table below for min.thickness.;' diem. (or smaller) Sch.10(or heavier) steel. 2 Metallic Pipe: A Steel Pi -4"diem. 0 Pre-Rated Gypsum Wallboard/Stud Wall Assembly > Copper Pipe-4 dram. or smaller Regular or heavier copper. O P ) Pe (or smaller)Sch. 10(or heavier steel t ( ) � ( ) Ply ) pipe. 2 Metallic Pipe-A Steel Pi 8"diem. or smaller Sch.40 or heavier steel pipe. > Copper Tubing-4" diam. (or smaller) Type M(or heavier)copper tubin B) Iron Pipe-4"diam.(or smaller)cast or ductile iron pipe. O p ) Pe- ( ) ( ) pip 9. Q Pipe Covering-Fiberglass insulation, see table below for thickness and annular space. B) Iron Pipe- 8"diem. (or smaller)cast or ductile iron pipe. C) Conduit-4"diem.(or smaller)EMT or steel conduit"Max.Pipe Pipe Covering Annular Space Packing Material Min. Sealant F-Rating T-Rating C) Conduit-4"diam. (or smaller)EMT or rigid steel conduit. Diem.,in. T lckness,in. in. Thickness,in. Thickness.in. Hr, Hr. D) Copper Tubing-4"diam.(or smaller)Type L(or heavier)copper tubing. 3 1 1/4 to 1-3/8 3-1/2 1/2 3 ] 1-1/2 1/2 D Copper Tubing-4"diem.(or smaller)Type L(or heavier)copper tubing. 1/4 to 5/8 3-1/2 1/4 1-1/2 1/2 E) Copper Pipe-4"diam. (or smaller)Regular(or heavier)copper pipe. 4 1/2 1/4 to 5/8 4-1/4 1/4 2 1/2 E) Copper Pipe-4"diem. (or smaller)Regular(or heavier)copper pipe. 10 1 1/2 to 1 4-1/4 1/4 2 1 30 Packing Material-See Table below for the mineral wool insulation requirements. 10 2 1/2 to 3/4 4-1/4 1/4 1-1/2 1-]/2 �� , 4 FYRE-S1L-Min. 1/2 thickness of sealant 11 /27/01 The annular space shall heroin. 1/4"to max. 5/8 within the firestop system. ® Packing Material- Mineral wool insulation(min. 4.0 pcf) firmly packed into opening applied annuhls,flush with top FYRE-SHIELD-Min. 1/2 thickness of sealant applied within opening. Additional sealant to the minimum required thickness in the table above. of floor surface or with both sides of the wall assembly. Revisions 30 to be installed such that a min. 1/4"crown is formed around the ® FYRE-SII,and FYRE-SIL S/L-Min. thickness of sealant as specified in the table above, Min.Thickness Annular Space Min.Packing Material Min.Packing Material F-Rating applied within opening flush with top surface of floor or both surfaces of wall. of Concrete. an in. Rce,in. Thickness.tn. Densrtv,ncf 4-1/2 1/2 to 2-7/8 3-1/2 6.0 2 penetrating item. NOTE: Apply FYRE-SIL S/L to Floor Applications Only. 5-1/2 0 to 1-7/8 5 4.0 4 Project: The Tremco products used above have been IU above described assembly has been Project. The Trerncn products wrod ahave have been tented in scxc"danee with the following: y floc above described erscattbl has been pro•ect: The Tremco is used above have been Project tasted end r betted ri both past and shat I tested in ER 14snoe with the following: toted and is based on both Y and"ci- j P The above described assembly 9 9 3 3 a I e m Location: • ASTM E814(UL1479)Standard Test Method • ASTM LrJt 14 � � tcxrod in eccerdancc with the followin Y�1� paled performance criteria Tremco shall not Location: (UL 1479)Standard Tas<Method rough Penetration Firostopping. I.008tlon: • AS1M E814(UL1479)Slaodaid Tesl Melbod tested and is based on loth 1 and audd- far 1 hrough Penetration K PP�B• for Th be liabl performs=or damages,direct or con- for fax Through Penetration Firmtvping. ��or��criteria. Tremco shall not be liable for any damages,director can- Installer. sequential,resulting from use of this material Installer sequential,resulting from use of this material be liable for any damage,direct or con- Date: 4/23/97 Drawing:TW-1097 or deign. Tremco shall only be resltormible Date: 3/13/97 Drawing:TR-5067 or design. Tremeo shall only be responsible Installer: sequential,resulting from use of this material Signature: Approved by: J.Piteole for roPlwing material found to be defective. Signature: APP*oved by: J.Pitcole for replacing material found to be defective. Date: 9/13/96 Drawing:TR-1064 or deign. Tremeo shall only be responsible Signature: Approved by: J.Pitcole for!e Pl aC1ng material f°nodtobedcfictivc. P09 PLUMBING DETAILS 7 , A b E T11,, Q N.T.S. rn i v rn rn �< ra ut 0 LE z `f.�±"`AAA''{• Y ` � £. 4 .. _N Seal (AR 1 6320) � E� .r t