Loading...
00-0332-015 i i w U..O..,�... ..�.. .. N M �. i Rated 2 Hour Fire Rated Through A W M C 1 or 2 Hour Fire 2 Hour Fire Rated Throw h � � o t:: t m- tONM'c�D G w k''4U- O Co m D vmme g D a. o o ao hrough Penetration Firestop for `yslf�� Penetration Firestop for s+ o W�Penetration Firestop for m.Multiple Metal Pipe throw h '"'� A °Z Q �:.�` ° Single Metal Pipe through 9 Single Metal Pipe through i„ in.,� Gypsum walls using u Concrete walls using Concrete floors or block walls 7 O z 5 ; '.� z N _Cr FIRE - SHIELD, ® FIRE-SHIELD or FIRE-SEAL, systems using TREMstop Acrylic, E �' a°'i to ° M`'a `d, l� F-rating = 1 and 2 Hr. F-rating = 2 Hr, V o a T-rating = 0 Hr, 1 W�012 _T-rating = 2 Hr, 1 g m* .., UL # WL1051 C377� ULr#tCAJ1205 Hr. ._ o r 3C 3A _ Q V W Z cc 2 .� W U Q 3A 3C _ co Q v W g = o0 a _ A 0 2 3B A N V) C Z W s� IE 1Q Wall assembly = 5' thick concrete, with Max area of opening 35,75 sq, in, 1Q Pre-Rated Concrete Floors or Block Walls = Min. 4-1/2' thick, Q2 *Steel Pipe - 2' diam, (or smaller) Sch, 5 or heavier, with annular space range of 0' to 7/8'. - 2" diam. (or smaller) EMT, 1Q 1 or 2 - hour fire rated gypsum wallboard/stud assembly *Max,*Conduit pipes or conduits. ® Conduit - Nom. 4' dia, (or smaller) steel conduit or EMT. (angular space range, min, 1/4' to max, 5/8") Q A) Steel sleeve - No. 30 MSG galy, sheet fitted within Packing Material - Mineral wool (min, 4 cf) compressed min, TO SHUNT © 9 P P TRIP BREAKER ® Conduit - 4' diam,(or smaller) EMT or rigid steel opening and secured to both sides 50% and installed into the opening to obtain of wall. min, 4' thickness, H 135' ELEVATOR ��MPPRRjNIC 1604 ® TREMCD # FIRE-SHIELD - min. 1/2" thickness of sealant B) Packing material - Min, 4' thickness ceramic fiber TREMCg # TREMstop Acrylic - Min. 1/2" sealant applied within TOP OF H 13" • insulation (6 cf) friction fitted, annulus, and a minimum 1/4' sealant applied at SHAFT installed within opening with a min, of 1/4 crown p point contact: at the floor surface for floors, ELEVATOR around ground the penetrating item applied flush C) Min. ';thickness FIRE-SHIELD or FIRE-SEAL, with !/. or both surfaces for walls. MACHINE ROOM with both side of wall assembly, crown formed around penetrating items, 135' H SIDE FIRE AND/OR SMOKE RATED WALL OR FLOOR PENETRATION DETAILS OF PIT Q FOUNDATION a PARTIAL RISER OF HEAT DETECTORS 4-1 __J 4_1 STEEL REBAR FOR ELEVATOR SHUNT TRIPPING. ° (f) N.T.S. 4 8 GROUNDING ELECTRODE — • 3/4' DIA x20'-0' LONG MINIMUM •� O E M LJ_ a a a cn _o (1) . _ ° a >COPPER CONDUCTOR `'-" E TO MAIN DISCONNECT(S) ELEVATOR ELECTRICAL NOTES o N a (SEE RISER) 0 • — 6\O �M 1. PROVIDE ELEVATOR DISCONNECT INSIDE ELEVATOR MACHINE ROOM WITH TIME •— ° iNJ DELAY FUSES (RK5) WITH REJECTION CLIPS. FUSES ARE TO BE SIZED AS z ° COLD WATER METAL REQUIRED BY ELEVATOR COMPANY SHOP DRAWINGS. (NEC 620-5). ° o Q) C- 4 ° PIPE MINIMUM OF 2. PROVIDE A DEDICATED 120V, 20A, BRANCH CIRCUIT PER NEC 620-22 FOR — a 20 FEET IN CONTACT ELEVATOR CAR LIGHTS WITH A DISCONNECTING MEANS. (MUST BE LOCKABLE IN Q -d WITH EARTH (BELOW THE OPEN POSITION AND WIRED TO ELEVATOR CONTROLLER). Q U.L. RATED CLAMP GRADE) 3. LIGHT FIXTURE INSIDE ELEVATOR MACHINE ROOM SHALL BE LENSED TYPE; OR Q FOR CONCRETE IF INDUSTRIAL TYPE, SHALL BE PROVIDE WITH WIRE GARDS AND TUBE GARD. Q ENCASEMENT (TYPICAL) TYPICAL 4. PROVIDE A 20A, 125V, GFI RECEPTACLE IN ELEVATOR MACHINE ROOM AND PIT. EXOTHERMIC p 5. PROVIDE A DEDICATED TELEPHONE LINE TO ELEVATOR CONTROLLER. (ONE CONNECTION (SEE NOTE BELOW) DEDICATE LINE PER ELEVATOR). 6. WHEN BANK OF ELEVATORS ARE POWERED BY AN EMERGENCY GENERATOR, GROUND CLAMP PROVIDE EMERGENCY POWER SELECTOR SWITCH WITH CONTROL WIRING TO MASTER OR GROUP ELEVATOR CONTROLLER. (2 SETS N.O. DRY CONTACTS, EMERGENCY POWER do NORMAL POWER, WITH 10 SECOND TIME DELAY). THESE CONTACTS WILL ALLOW FIRE DEPARTMENT TO SELECT WHICH ELEVATOR WILL RUN ON EMERGENCY POWER, AND WILL ALSO ALLOW REMAINING ELEVATORS v TO BE LOWERED ONE AT A TIME TO DESIGNATED FLOOR. 7. ELEVATOR CAB(S) SHALL BE PROVIDED WITH A TELEPHONE OR A MEANS OF TWO-WAY COMMUNICATION. TYPICAL 3/4- DIA x 10FT 8. PROVIDE TWO VAPOR TIGHT LIGHT FIXTURES CONTROLLED BY A SWITCH INSIDE LONG COPPERCLAD STEEL EACH ELEVATOR PIT. GROUND DRIVEN ROD. 9. WHEN A HYDRAULIC ELEVATOR HAS PROVISIONS FOR LOWERING BY BATTERY, THE MACHINE ROOM DISCONNECT, WHILE IN THE 'OFF- POSITION (OPEN), MUST PREVENT THE ELEVATOR FROM LOWERING UNDER BATTERY POWER TO SHUT DOWN THE BATTERY LOWERING FEATURE WITH THE ELEVATOR DISCONNECT 11 /27/01 SWITCH, THE CONTRACTOR SHALL PROVIDE AN AUXILIARY SET OF CONTACTS IN Revisions THAT SWITCH AND A PAIR OF J16 WIRES TO THE ELEVATOR CONTROLLER TO BUILDING SERVICE GROUND DETAIL DISABLE THE BATTERY LOWERING FUNCTION. THE BATTERY LOWERING FUNCTION SHALL ALSO BE DISABLED UNDER SHUNT TRIP OPERATION, SEE BELOW. SCALE: N.T.S. 10. WHEN A BUILDING IS PROTECTED BY A WET PIPE SPRINKLER SYSTEM AND NOTE SPRINKLER HEADS ARE INSTALLED IN THE ELEVATOR SHAFT, THE ELEVATOR PIT, IF BOLTED GROUND CLAMPS ARE USED IN LIEU AND THE ELEVATOR MACHINE ROOM. PROVIDE FIXED TEMPERATURE HEAT OF EXOTHERMIC WELD PROVIDE A GROUND ACCESS DETECTOR NEXT TO EACH SPRINKLER HEAD ON THE TOP OF THE SHAFT, SIDE Project WELL FOR EACH GROUND ROD. OF THE ELEVATOR PIT, AND ELEVATOR MACHINE ROOM. HEAT DETECTOR 9933a�em TEMPERATURE SHALL BE LOWER THAN SPRINKLER HEAD TEMPERATURE, VERIFY WITH FIRE PROTECTION CONTRACTOR PRIOR TO ORDERING. THESE HEAT DETECTORS ARE NOT CONNECTED TO THE BUILDING'S FIRE ALARM SYSTEM, BUT ARE USED EXCLUSIVELY FOR TIPPING OF THE ELEVATOR SERVICE DISCONNECT AT THE MAIN ELECTRICAL ROOM. PROVIDE SHUNT TRIP BREAKER AT EACH ELEVATOR SERVICE DISCONNECT. IF ELEVATOR IS EQUIPPED WITH A BATTERY LOWERING FEATURE, AN ADDITIONAL Ems ELECTRICAL DETAILS SET OF AUXILIARY CONTACTS. MUST BE PROVIDED AT THE HEAT DETECTOR AND 2#16 WIRES SHALL BE PROVIDED TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE. IN LIEU OF ADDITIONAL CONTACTS AT THE HEAT DETECTORS, THE CONTRACTOR SHALL PROVIDE ADDITIONAL WIRING FROM THE SHUNT TRIP BREAKER TO THE ELEVATOR CONTROLLER TO DISABLE THE BATTERY LOWERING FEATURE. THIS WIRING WILL BE INSTALLED IN SERIES WITH Sheet g of g THE AUXILIARY DISCONNET SWITCH CONTACTS. THE DRY CONTACTS CONTAINED IN THE AUXILIARY SWITCHES ARE CLOSED WHEN EITHER THE SHUNT TRIP OR DISCONNECT IS IN THE -ON- POSITION AND WILL BE OPEN WHEN THE E DISCONNECT IS OPENED OR SHUNT TRIP/HEAT DETECTOR ACTIVATED. i 0 r7 rn m rn rn U `/