Loading...
00-0332-001 METROPOLITAN DADE COUNTY, FLORIDA METROOADE DEM EMVIRONMENTAL�YAKA�?fr PW�REVIEW SECTION ENVIRONMENTAL REVIEW OF I)WNAGE SYSTRM III Kvi.IsTaMET suffE 1010 NAM,KOMA33124.1= Date L�� pool ataas3o Project ame M �2 I F�u`)EE Location Section S4 Range c L 0 Tentative Plat Location within C.O.I Totes Basin ❑` Review for Compliance with Dade County Aquifer Protection Requirements. ' Provide Oil and Grease Interceptors at all Catch.Basins preceding French Drains , as per attached standard details. ❑ Provide Oil and Grease Interceptors at Structure No.: All French Drains to have invert of perforated pipe and minimum elevation of Oct. groundwater level of Z NGVD or higher. [] ` Review for compliance with Section 24.12.1 of Metropolitan Dade County Code. COMMENTS: 1. French Drains shall be as per SD1.1 2. Catch Basin shall be as per SD16 with Oil & Grease interceptors (baffles) preceding all French Drains. 3. Property line must be graded to avoid runoff into adjacent property. 4. This review is for Stormwater Quality only; Stormwater Quantity to be reviewed by Public Works Department. Outside C.O.I. 1. Design for compliance with D.C.Aquifer Protection Requirements. 2. Commercial/Industrial & Residential with Parking Area,provide Pollution Retardent Structures at all Catch Basins. Inside C.O.I Design for compliance with Dade County Code Chapter 24.12 DCFC Revie%ved by_ 01-, �� �� � � Y + WT