00-0896-011 . _ ..-... ..... .... .....-. . ... .. . . ...
TYPE/WATTS SYMBOL DESCRIPTION MTG` VOLTS LAMPS MANUFACTURER CATALOG No. NOTES SYMBOL L E I V D REVISIONS BY
S S
A TRACK CHANNEL TRUSS PM 120 BEV.HILLS BEV BHT2020-WO 1 1/2"C 2#14 •°
�Q W/6' TRACK ELECT. WORKS LT-6B/LA-10B INTERCEPT EXISTING CONDUIT, EXTEND 3/4"C.O. W/
CONTECH TO NEW TELEPHONE BD. PULL STRING
((n DUPLEX GROUNDED CON\/ENIENCE OUTLET MOUNTED IN
�G" FLUSH BOX AT +18" UNLESS NOTED OTHERWISE.
Al 24" STEM MOUNTED LO VO PM 120 USHIO CONTECH CTL9016-B/LA1024-B a T CEILING SPACE S S DUPLEX GROUNDED CONVENIENCE OUTLET MOUNTED IN
50 � SZ = TRACKHEAD 50 MR16 qp SURFACE 30X AT +18" UNLESS NOTED ,bTHERWISE.
NFL EXISTING CONDUIT 3/4"C.O. W/ 3/4"C.O. W/ 1/2"C 4#14 1/2"C 4#14 ® DUPLEX GROUNDED CONVENIENCE OUTLET, SEPERATED, MOUNTED IN
(FIELD VERIFY) PULL STRING PULL STRING V FLUSH BOX AT +18" UNLESS NOTED OTHERWISE.
H
A2 PAR TRACKHEAD PM 120 PHIL 75 CONTECH CTL830-B 2 2'x4'x3/4" 1"C 4PAIRS #14 DUPLEX GROUNDED CONVENIENCE OUTLET, MOUNTED HORIZONTALLY
75 PAR30L/H/ PLYWOOD 9 IN FLUSH BOX AT +18" UNLESS NOTED OTHERWISE.
NFL30 TO BE MTD. ® CASEWORK,
TELE. BD. COORDINATE EXACT LOCATIONS 8'-0" MIN. DOUBLE DUPLEX GROUNDED CONVENIENCE OUTLET MOUNTED
A3 LO VO THEATRICAL TRACKHEAD/ PM 120 USHIO CONTECH CTL9016-B 6'-0"
NTH CASEWORK CONTRACTOR IN FLUSH BOX AT +18" UNLESS NOTED OTHERWISE.
NO STEM 50 MR16
(mGF1 CONVENIENCE OUTLET WITH INTEGRAL GROUND FAULT
50 G"
NFL
® INTERRUPTER.® NOTE: ELECTRICAL CONTRACTOR TO PULL #14 SPEAKER WIRE FLOOR MOUNTED DUPLEX CONVENIENCE OUTLET.
CHANDELIER PM 120 280W CUSTOM OWNER SUPPLIED ® ® FROM EACH SPEAKER TO CASH WRAP AREA. (LEAVE W-01 TAIL TYP.)
B / SEE PLAN ® & IDENTIFY EACH (FRONT, REAR.) POLARITY OF SPEAKER WIRE IS ® FLOOR MOUNTED DUPLEX GROUNDED CONVENIENCE OUTLET.
280
CHANDLE ® FINISH FLOOR IMPORTANT.
CLEAR ® CEILING MOUNTED DUPLEX CONVENIENCE OUTLET.
D2 PRESCOLITE PBX HOUSING/ RC 120 PHIL 75 PRESCOLITE PRESCOLITE PBX W/ TA30C TRIM
SPEAKER RISER T UNLESS ONOTED TOTH�ERWS E.
O BLACK ADJUSTABLE TRIM PAR30L/H/ p DATA OUTLET, +18"
75 i
HFL30 TELEPHONE RISER DIAGRAM NO SCALE E1 5 DIAGRAM NO SCALE E1 6 UNLESS NOTED OTHERWISE. Q
LO VO TRACKHEAD/ W/ CLIP PM 120 PHIL 25 CONTECH CTL9836T-B/FA-368/LF30-R FLOOR MTD. TELEPHONE OUTLET Q
F
RED LENS PAR 36
FLOOR MOUNTED JUNCTION BOX.
25
VNSP
CEILING MOUNTED JUNCTION BOX. U co
EXISTING - FOR EXISTING EQUIPMENT, VERIFY
BATHROOM FAN LIGHT RC 120 PHIL NUTONE 668-RP SIZE, LOCATION, AND THAT EQUIPMENT IS IN JUNCTION BOX, FLUSH MOUNTED AT +12" UNLESS NOTED L1.1 rn
/
G 75A GOOD WORKING CONDITION. NOTIFY CLIENT OTHERWISE. ~ cp
110 :E IMMEDIATELY OF ANY DISCREPANCIES. �.1�'
120V 2 v
JUNCTION BOX WITH FLEXIBLE CONNECTION. U r)
K 2 TUBE FLUORESCENT STRIP CH 120 PHIL F40 LITHONIA C-240-120-ES 3 3 7 OT TELEPHONE JUNCTION BOX. --f
Q N
1 NEW 60A 3P FUSED DISCONNECT WITH 60A FUSES. v
CWRS/EW/ I I I DATA JUNCTION BOX.
72 ALTO OD
ONEW 1-1/4"C 4#4 CU. + 1#10 CU. GIRD. �a SPST TOGGLE SWITCH. NON-CAPITALIZED LETTERS INDICATE Z
LED EXIT BATTERY PACK UN 120/ INCLUDED MCPHILBEN CCL1R8 4 WHICH FIXTURES AND OUTLETS THEY CONTROL. MOUNTED Q
X1 / / I I I PANEL PANEL O NEW 277/480V 12-CKT. 3,0 4W PANEL 'HP' FLUSH IN BOX AT +42" UNLESS NOTED OTHERWISE. N
30 2 HEAD EMERGENCY WALL PACK 277 HP 'LP (Y n
O4 NEW 1"C 4#8 CU. + 1#10 CU. GIRD. 3 THREE-WAY SWITCH, +42" UNLESS NOTED OTHERWISE. O M
0
X2 2 HEAD EMERGENCY WALL PACK SW 120/ INCLUDED MCPHILBEN CA6B 4 I I ( 40/3 4 O NEW 30KVA DRY-TYPE TRANSFORMER WITH �0 DIMMER SWITCH, +42" UNLESS NOTED OTHERWISE. Q Q Q
30 O 277 I I 5 100A #8 CU. GIRD. iM MANUAL MOTOR STARTER, +42" UNLESS NOTED OTHERWISE. Z Q W
1 O NEW 1 1/2-C 4#2 CU. + 1#8 CU. GIRD. Q O ~
* RC = RECESSED CEILING, SC = SURFACE CEILING, SW = SURFACE WALL, RW = RECESSED WALL, PL = POLE MOUNTED, — I a' <DISCONNECT SWITCH, "F" INDICATES FUSED TYPE. J O
NEW 120/208V 42-CKT. 3,0 4W PANEL 'LP'
O7 Q
PM = PENDANT MOUNTED, UN = UNIVERSAL MOUNT, FG = FLUSH, GRADE MOUNTED, CH = CHAIN HUNG WITH NEW 100A MAIN CIRCUIT BREAKER. FLUSH MOUNTED LIGHTING OR POWER PANEL. o J
LANDLORD'S 277/480VO 120/208V J
1. USE 4'-0" SURFACE MOUNTED TRACK ® DISPLAY WINDOW CABLE BOX XFMR 3m 4W ® SURFACE MOUNTED LIGHTING OR POWER PANEL. O
2. MOUNT FIXTURE ON 4'-0" SURFACE MOUNTED TRACK ® DISPLAY WINDOW 6 TELEPHONE BACKBOARD, SIZE AS NOTED ON PLANS.
3, FIXTURES TO BE CHAIN HUNG IN OPEN CEILING AREA l::3 EMERGENCY LIGHTING FIXTURE W/ INTEGRAL BATTERY PACK.
FACP FIRE ALARM CONTROL PANEL SEMI-FLUSH MOUNTED ® +48" A.F.F.
4. BLACK FINISH
TO CABINET BOTTOM.
FS SPEAKER U
LIGHTING FIXTURE SCHEDULE NO SCALE E1 3 SINGLE LINE DIAGRAM NO SCALE E1 4 SO SMOKE DETECTOR, CEILING MOUNTED. Q
O HEAT DETECTOR, 135-F FIXED TEMPERATURE, CEILING MOUNTED
NEWH WITH PLUG-IN BASE - 4" OCT. BOX.
MANUAL PULL STATION MOUNTED 0 +48" � A.F.F. - 4" SQ. BOX WITH W
VOLTAGE: 120/208V PANE BUS: 225A MAIN BRKR: 100A / 3P W
1-GANG RING.
PHASE: 3 WIRE: 4 MLO ❑ DOUBLE LUGS ❑ - STROBE (117 CANDELA) MOUNTED ®7'-6" A.F.F. - 4" SQ. BOX.
cn 0z
MOUNTING: SURFACE AIC SYMMETRICAL: 10,000 ELECTRONIC STROBE HORN (103 dB HORN, 117 CANDELA STROBE) 0
NEWMOUNTED ® 7'-6" A.F.F. - 4" SQ. BOX. —
� � Q � —J
LOCATION j® A B C � ® u LOCATION �� ELECTRONIC HORN (103 dB) MOUNTED 0 7'-6" kF.F, - 4" SO. BOX. Cj W W W
VOLTAGE: 277/480 PANEL BUS: 100A MAIN BRKR: �+ �+ CEILING MOUNTED LIGHTING CONTROL OCCUPANCY SENSOR. W Z =
SHOP SIGNAGE TC • 1 20 1 1200 2 20 1 • DISPLAY WINDOW TC #$ O Z
PHASE: 3 WIRE: 4 P MLO ■ DOUBLE LUGS ❑ D 180 0 .� WALL MOUNTED BI-LEVEL LIGHTING CONTROL OCCUPANCY SENSOR. W = D Q
MOUNTING: SURFACE AIC SYMMETRICAL: 10,000 ENTRY DOWNLIGHTS TC • 1 20 3 880 4 20 1 • DISPLAY WINDOW TC A Gj W O
M TYPICAL FIXTURE DESIGNATION, SEE FIXTURE SCHEDULE. W = f)
LOCATION j ® A B C LOCATION ENTRY DOWNLIGHTS TC • 1 20 5 1020 6 20 1 • SALES AREA RECEPTACLES 60 V � V)
30KVA TRANSFORMER �+ 5620 AC-1 TRACK LIGHTING �135O SALES AREA RECEPTACLES TYPICAL MECHANICAL EQUIPMENT DESIGNATION. SEE
AC
• 3 40 1 1108 2 15 3 • • 1 20 7 8 20 1 • 1 MECHANICAL SCHEDULES.
3 8033 4 TRACK LIGHTING 1350 STOCK / RESTROOM RECEPT.
1108 • 1 20 9 540 10 20 1 • O2 TYPICAL NOTE DESIGNATION, SEE SHEET NOTES.
5 5635 6 TRACK LIGHTING 1350 CASHWRAP RECEPT. S SPEAKER SYSTEM CONDUIT, SIZE AS NOTED ON PLANS
1108 • 1 20 11 360 12 20 1 • 'CONV. ONLY' DUPLEX LO
F FIRE ALARM SYSTEM CONDUIT, SIZE AS NOTED ON PLANS
SPACE 7 8 15 3 • DUCT HEATER TRACK LIGHTING 1350 CASHWRAP RECEPT. LO T TELEPHONE SYSTEM CONDUIT, SIZE AS NOTED ON PLANS
1667 • 1 20 13 180 14 20 1 • POINT OF USE' DUPLEX
TRACK LIGHTING E1350 CASHWRAP RECEPT. BRANCH CIRCUIT CONDUIT, CONCEALED IN WALL OR CEILING.
9 1667 10 • 1 20 15 16 20 1 • 'POINT OF USE' DUPLEX _ _ _ _
BRANCH CIRCUIT CONDUIT, CONCEALED IN FLOOR OR
11 E1667 12
TRACK LIGHTING • 1 20 17 �1350 18 20 1 • FUTURE SECURITY SYSTEM UNDERGROUND.
L 600 CHANDLIER 280 TELEPHONE BACKBOARD -------- BRANCH CIRCUIT CONDUIT, RUN EXPOSED.
SUBTOTAL VA: 8395 10808 8410 TOTAL VA: 27613 • 1 20 19 180 20 20 1 • a rul -
CONDUIT RUN TURNED UP.
# RESTROOM AND • 1 20 21 608 22 30 1 • WATER HEATER • CONDUIT RUN TURNED DOWN.
j = LTG / (p= RCPT TOTAL 3� AMPS: 33.2 HIGH PHASE AMPS W/ LCL: 39.0 DRESSING ROOM 3000
' EMERGENCY AND LO • 1 20 23 105 24 SPACE 3 CONDUIT RUN STUBBED OUT,
NIGHT-LIGHTING A-1
- — BRANCH CIRCUIT HOMERUN WITH PANEL AND CIRCUIT DESIGNATED.
SPACE 25 26
LL 2#12-1/2•C. ri; 3#12-1/2"C.
27 28 T� 4#12-3/4'C. 5#12-3/4"C.
29 30 6#12-1"C. 7#12-1•C.<El>PANEL SCHEDULE ' H P ' NO SCALE E1 0 ALL CONDUIT SHALL BE PROVIDED WITH A #12 CU GROUND WIRE U.N.O.
31' 32
AFF ABOVE FINISH FLOOR, rr
Cl
d
33 34 C.0. CONDUIT ONLY. o CO
CONNECTED AREA WATTS PER WP WEATHERPROOF. z o 0
LOAD LOAD (VA) SQ. FT. SQ. FT. 35 36 c-) oo a �Cj
X INDICATES EXISTING TO REMAIN. �� U
LIGHTING 10968 1653 *6.64 37 38 R NEW LOCATION OF RELOCATED EXISTING FIXTURE/DEVICE u � o I'
Ill (Dco
RECEPTACLES 3420 39 40 Lu > o 6 °°
U.N.O. UNLESS NOTED OTHERWISE
ff
ROOF TOP UNIT 8325 1653 5.04 Q o a
F.B.O. FURNISHED BY OTHERS o -1 z
TIME CLOCK • 1 20 41 100 42
NOTE: THIS IS A STANDARD SYMBOL DEFINITION TABLE, THEREFORE
WATER HEATER 3000 SOME OF THE SYMBOLS SHOWN MAY NOT BE USED.
DATE 7-11 -00
SIGNAGE 1200 1653 0.73 SUBTOTAL VA: 5620 8033 5635 TOTAL VA: 19288 NOTE:
MISCELLANEOUS 700 LTG � RCPT TOTAL 34) AMPS: 53.6 HIGH PHASE AMPS W/ LCL: 66.9 REFER TO LANDLORD STANDARDS AND GOVERNING SPECIFICATIONS SCALE AS NOTED
/ =
PRIOR TO BID AND INSTALLATION OF WORK BY THESE DRAWINGS. DRAWN JR/RT
TOTAL 27613 1653 16.70 ,.•, . ,,,,
TC TO BE CONNECTED VIA A 24-HOUR INTERMATIC SERIES T104 FOR 1,2,4,8, OR 16 LOADS. COORDINATE WITH OWNER. JOB HT-SHPSNSET
• THIS LOAD IS BASED ON THE PANEL SCHEDULE LIGHTING LOAD _`�'`` ` •' WF j f3
THE PANEL SCHEDULE LIGHTING LOAD FOR TRACK LIGHTING IS BASED C'
ON 150W 2LFT. PER NEC 410-102. THE TRUE LIGHTING LOAD (VA. LO LOCK-ON DEVICE lti, �c* ' SHEET
_� I,o OOSIG96 x ti ,��
BASED ON ACTUAL FIXTURES USED IS 9168VA TRUE LIGHTING )
NOTE: ELECTRICIAN TO LABEL PANEL CLEARLY INDICATING THE TYPE & LOCATION OF EACH LOAD nSTATE
f ,,� ±,: E 1
LOAD WATTES PER SQ.FT. = 5.55. t
` .
OF SHEETS
LOAD ANALYSIS No SCALE E, , PANEL SCHEDULE LP No SCALE E1 2 '; +r`" .�� `p�co