00-0896-009 I i 1 - - - - - - - REVISIONS BY NOTES i1 8-21-00 LY CHILLED WATER SCHEDULE LE I I I I BALANCE ALL DUCT SYSTEMS, INCLUDING SUPPLY DIFFUSERS, RETURN I I I I EXHAUST REGISTERS AND TOILET EXHAUST. TEST AND BALANCE EQUIP# TYPE MFC SIZE OSA CFM CFM SP I HP CAP COOLING SENS FLOW RATE PD' EWT LWT AT D13 D13 EER VOLT COOLING HEATING I SHALL BE PERFORMED BY AN INDEPENDENT, APPROVED AND I-I I-� MBH COOLING GPM EAT LAT NOT COIL CERTIFIED AABC OR NEBB CONTRACTOR. SUBMIT TWO COPIES OF CHILLED WATER GIVEN THE FINAL REPORT TO THE LANDLORD. EF 10 D-2 1 100 AC-1 AIR HANDLER CARRIER 39L 6 331 3000 1 .5" 2 85.07 67.47 16.0 1 .1 457 5 (CENTRAL 5 63 10.6 80.0 F 59.4 F SYSTEM) 460/3 6 ROW 8 KW ALL HVAC SYSTEM SMOKE AND FIRE DETECTORS SHALL BE COMPATIBLE � � WITH LANDLORDS FIRE ALARM SYSTEM. I I I I I I i I II I I i I I I I I O - - VERIFY EXISTING CONDITIONS r r� HVAC DESIGN REQUIRES: THERMOSTAT SCHEDULE ' � �;!,' HVAC DESIGN REQUIRES: YES NO C7 c� C7 c7 C7 c7 c� c� DUCT SMOKE DETECTOR C�ILa ==`--==+�----�.1 — c�IL LLr'� c�---+�--_�t== _ ---.c'-'� cam= _�c-_ ,,�_ x='� <� C._:-- --, II MAKE: TED-AVU MFG BY LIGHTSTAT L� L� _ L1 L, L, L, L, L, L, L, L, LA LA ` LA L, MODEL: ELECTRONIC (� D-1 (� ;�; FIRE DAMPER(S) TECH SUPPORT CONTACT: 800-292-2444 C 6 EA 483 .-� „ _ � SMOKE DAMPER(S) ® a VERIFY COMPATIBILITY W/ EXISTING CONTROLS g 12 RD 12 RD _ �I Q 12 RID 12"RD I FIRE RATED ENCLOSURE ® - ��' � C =,►_--=__—___ _>> C�=h-===- -_�=>> C ___----- �`-___- ___ �� - FIRE RATED ROOF FLOOR U co CEILING ASSEMBLY J CDo 22 'RD ,� f — co 20 R D------ -- ------ 14 R D ��I ---r---------r-� ss--� , -- � � FIRE STOPPING ® � VERIFY EXISTING rSMOKE ;�r—I U" SMOKE CONTROL CONDITIONS r� i ; , I L.--J ; --- - - -- --DETECTOR ���J L___L__ I- 1 ' I R 7 x l` F------a 7 c 7 f'I c 7 1 .s C0 2669 CFM RA r—;I t, q� 1 ♦` . �\\' I 41 t� 4Y 1 U N • 1 2"RD C I I `♦♦ Ili ��� 12"Rq rJ ' 1♦ �� I LAV-1 12"RD 4 �I 1 I ��- , Z Q w -1 V-�i 1 2's RD ---------i---------y'==_--_�-� —1 �J r� p Q x 3• �ilkli J L-------� Zc7 c7 c7 � AC c� c� c7 c7 c7 c7_ _c7 c7 c7 c7 � c� c� O� Cc-ter_--= _c_==='�_ �'� 1 O ='c- t +c - �r_ ti-tie_- L A ILA ILA � O 3"VTR 2"V TP— 1/2• U L� L� L� LI L, LA L, L� - elf � Q -i 1 -1/4" INSULATED CHS + CHR r_ ►�-- r j O ° TO LL VALVED CONNECTION _ �_ ;� U � o PLUMBING PLAN _ `_ -_ - SCALE: 1 /4 '-0" 2 MP-1/ W MECHANICAL / PLUMBING PLAN SHEET NOTES SYMBOL LEGEND Q AIR DISTRIBUTION VERIFY EXIST CONDITIONS AND ELECTRICAL REQUIREMENTS BEFORE ORDERING EQUIPMENT. VERIFY SIZES AND LOCATIONS 0-- EXISTING DEVICE, DUCT, PIPE LU ADJUST AND BALANCE TO OBTAIN PERFORMANCE U) BASED ON REQUIRED AS SHOWN. NOWf1- REMOVE EXISTING DEVICE, DUCT, PIPE Z > MARK DESCRIP'N CFM PATERN VOLUME NECK PANEL MOUNTNG REMARKS (D _ AC NEW CHILLED WATER AIR HANDLER W/ 8 KW ELECT. U7 CONTR'L SIZE SIZE METHOD MF'R MODEL DUCT HEATER /D--H\CARRIER #39L SIZE 6, BELT DRIVE �— DEVICE, DUCT, PIPE ry ry SET FOR 3000 CFM, ® 2" SP, 2 HP, 460/3/60, Q D-1 SUPPLY 483 O ROUND OBD 12"RD NA DUCT TMR* ADJUSTABLE TYPE CHILLED WATER COIL, 6 ROW, 45 ENT, 54 LWT, 16 GPM, SUPPLY AIR (SA) W DIFFUSER TITUS �4 INSULATED SUPPLY & RETURN PIPING, ECONOMIZER (n SUPPLY CONTROLS ARE REQUIRED. PROVIDE FOR 331 CFM MIN OSA RETURN AIR (RA) 4 O — D-2 DIFFUSER 100 4-WAY OBD 6"RD 12X12 TITUS TMR* ADJUSTABLE TYPE PIPING FITTINGS, & CONTROLS PER LL STANDARDS. _ D ORELOCATE OUTSIDE AIR INTAKE. SET FOR 331 CFM OSA MINIMUM. EXHAUST AIR (EA) U (f) � 100 % MAXIMUM. O3 SMOKE DETECTOR. VERIFY LOCATIONS AND REQUIREMENTS. < _ � �T THERMOSTAT � � � uj O RUN DUCTWORK AS CLOSE TO ROOF AS POSSIBLE. SD SMOKE DETECTOR G_1 RETURN 2669 0 DUCT U5 FACE OF DIFFUSERS SHALL BE AT THE SAME HEIGHT AS FACE OF THE LIGHT FIXTURES. 12'-0" OR AS INDICATED ON ARCH. DRAWINGS. AF FIRE DAMPER IF PENETRATING 1 HR. * OR APPROVED EQUAL O COMPLY WITH MALL REQUIREMENTS ON SMOKE EXHAUST. O PAINT ALL CEILING GRILLES, REGISTERS, DIFFUSERS, LIGHT VOLUME DAMPER TRACKS, ETC. TO MATCH ADJACENT CEILING FINISHES. \ O WALL THERMOSTAT, MOUNT AT 5' ABOVE FINISHED FLOOR. —�poc POINT OF CONNECTION EXTEND VENT O TO COMMON SYSTEM 3/4" CONDENSATE DRAIN TO LL CONNECTION & SEPARATE OVERFLOW AC EQUIPMENT DESIGNATION �`♦ TO FLOOR DRAIN ♦�\`2, 10 EF-1 TOILET EXHAUST FAN 6" ROUND DUCT THRU D-1 AIR DISTRIBUTION DESIGNATION SEE PLUMBING EXTEND TO POC ROOF WEATHER CAP OR LL EXHAUST CONNECTION. 500 AIR QUANTITY (CFM) �� FLOOR PLAN 11 NOT USED rA-") BALL VALVE ' MP-3 REFERENCE DETAIL I 3/4" I I 2 REFERENCE NOTE I PROJECT CALCULATIONS R 20 EFERENCE NOTE ' PEOPLE= 1282sf/50sf/person = 26 people CD CONDENSATE DRAIN TO FLOOR DRAIN I 26 sf x 15 CFM/sf = 390 CFM OSA ' LOCATION: SHOPS @ SUNSET PLACE, MIAMI, FL.; SPACE #14 OSA OUTSIDE AIR LAV INSTANTANEOUS ELECTRIC WATER n FLOOR AREA: 1,653 sf f, RETAIL=1,282 sf VTR VENT THRU FLOOR HEATER (CHONOMITE � I ��♦ DESIGN SUMMER: INSIDE = 75db OUTSIDE = 91db, 77wb AT = 16 =R= REFRIGERANT LINES *5-302 120 1/60,3KW, 30FLA VERIFY 1/2 i I CONDITIONS: WINTER: INSIDE = 70db OUTSIDE = 44 db, �T = 26 MOUNT WATER HEATER UNDER 1/2" i I ��112 / HEAT LOSS CALCULATIONS: O LAV W/ APPROVED MOUNTING 1 ' 1-1 1 BRACKETS AND SUPPORTS. �2„ ; ROOF: 1635 SF X 26 X .057 = 2,423 BTUH z o 4 I ' LAV BACK WALL: 655 SF X .17 X 26 = 2,895 BTUH MECHANICAL AND PLUMBING CONTRACTOR SHALL ° VERIFY VOLTAGE AVAILABLE i i GLASS: 275 X 1.09 X 26 = 7,794 BTUH o N I2" 2, OSA : 331 sf X 26 X 1.085 = 11,002 BTUH VERIFY ELECTRICAL REQUIREMENTS FOR THEIR ° Z C °n TRAP I TOTAL = 27,73, BTUH EQUIPMENT FROM ELECTRICAL CONTRACTOR AND u > in W Ln Wc (PRIMER ; PROMPTLY NOTIFY ANY DISCREPANCIES TO � ° L --� DESIGNER AND GENERAL CONTRACTOR. C af 1 � j ALL HOT AND COLD WATER LINES I HEAT GAIN CALCULATIONS: SHALL BE INSULATED WITH 1/2" WC 4 14" GLASS: 275 X 1.09 X 16 = 4,796 BTUH DATE 7-11-00 4" FLOOR CO ROOF: 1635 SF X 75 X .057 = 6,990 BTUH ALL HVAC WORK SHALL BE SUBJECT TO SNAP-ON INSULATION. 3"FD ' 3' WALLS: 655 SF X .17 X 525 = 2,784 BTUH EXTERNAL AUDIT TO DETERMINE COMPLIANCE SCALE 1/4 =, -o SOLAR: 275 X SF X .67 X 50 = 9,213 BTUH WITH DRAWINGS AND QUALITY OF THE HOT AND COLD WATER LINES LIGHTING: 5.5W X 1282 sf X 3.415 = 24,079 BTUH DRAWN SAR PEOPLE: 26 X 250 = 6,500 BTUH WORKMANSHIP. SOIL WASTE AND VENT DIAGRAM OSA: 331 CFM X 16 X ,.085 = 6,770 BTUH MOTOR HP 1.5 X 2445 = 3,668 BTUH .�' Utltl. �,E��;A.;` , JOB HT-SHPSNSET TOTAL SENSIBLE HEAT GAIN = 60,004 BTUH SHEET PEOPLE: 26 X 200 = 5,200 BTUH hra'OtJSIU.6`^ tff 4 3 2 1 0 2 4 OSA: 390 CFM X 68 X 20 = 5,300 BTUH E -� GRAPHIC SCALES g—®— M P - 1 TOTAL LATENT HEAT GAIN = 10,504 BTUH � . fAff° '" ` r PLUMBING DIAGRAMS FOR TOILET ROOM NO SCALE: --------- SAFETY SAFETY FACTOR (10%) = 1,051 BTUH �,'j'�1 ..• �4, .� � � GRAND TOTAL HEAT GAIN = 77,559 BTUH = 6.5 TON •//s�� CADD NO. OF SHEETS f