Loading...
00-0896-001 I i + _ rr, STOREFRONT SIEN DETAILS EENERAL NOTES RESPONSIBILITY SCHEDULE SHEET NDEX REVS►OHS — BY r SHEET DESCRIPTION err 1. ALL WORK SHALL BE DONE IN ACCORDANCE WITH APPLICABLE CODES, ® NOT USED REGULATIONS AND LANDLORD'S REQUIREMENTS. °w ° °w ° Uw ° T-1 SIGN DETAIL, GENERAL NOTES, KEY PLAN, � y3 EXISTING (UPGRADE AS REQD.) w _j w _j `� r ?�, ul J V ) J U V J J J O ..,�... ✓ s 1" SIGN BRACKETS 2• DO NOT SCALE DRAWINGS. FIELD VERIFY ALL DIMENSIONS AND JOB z o Q o z 6 a (3 z _j Q _j PROJECT DAT,4,, RESP3NSIBIL;TY SC'i;EDULE j'• >� < 9 1 60 9' ATTACHED,, TO PIECE CONDITIONS. EXISTING (REPAIR & REPLACE AS REQD.) `- `- V) �' to OF 3 5/8 , 16 GA. TRACK � m Z m � m ? m � m Z m A-1 FLOOR PLAN, NOTES 3. SHOULD ANY CONDITION ARISE WHERE THE INTENT OF THE DRAWINGS IS IN DOUBT, OR WHERE THERE APPEARS TO BE AN ERROR ON THE CEILING LINE DRAWINGS OR A DISCREPANCY BETWEEN THE DRAWINGS AND FIELD NEUTRAL PIER A-2 REFLECTED CEILING PLAN, FIXTURE SCHEDULE, {SEE STORE FRONT SECTION) CONDITIONS, THE DESIGNER SHALL BE NOTIFIED AS SOON AS POSSIBLE FOR THE PROCEDURE TO BE FOLLOWED, IF THE CONTRACTOR PROCEEDS DEMISING WALL A-3 INTERIOR ELEVATIONS, COLOR AND MATERIAL 1" STEEL WITH THE WORK SO AFFECTED WITHOUT INSTRUCTIONS FROM THE J SUPPORT TUBE DESIGNER, THE CONTRACTOR SHALL MAKE GOOD ANY RESULTING DAMAGE REAR ENTRANCE SCHEDULE, FIXTURE SKETCHES i 1/8" THICK PLATE OR DEFECTS, THIS INCLUDES ERRORS IN THE SPECIFICATIONS AND / NOTATIONAL ERRORS ON THE DRAWINGS WHERE DOUBTFUL OF METAL STUDS & DRY WALL ® ® A-4 STOREFRONT ELEVATION, PLAN DTL., SECTIONS _ •' � RAW STEEL W/ 00 I CLEAR FINISH INTERPRETATION. 00 BOTHS DS OF SIGN 4. IN THE CASE WHERE TWO OR MORE DETAILS APPLYING TO THE SAME GYP. BD. SOFFITS & CEILING ® ® A-5 DETAILS LASER CUT LETTERS PART OF THE WORK ARE IN CONFLICT, THE MOST RESTRICTIVE SHALL RED PLASTIC VACUUM GOVERN UNLESS CLARIFIED OR OTHERWISE APPROVED BY THE DESIGNER. SUSPENDED CEILING ® A-6 SPECIFICATIONS FORMED LETTERS TO 5. THE CONTRACTOR AND EACH SUBCONTRACTOR SHALL CAREFULLY EXAMINE TO PROJECT OUT THE CONDITIONS AFFECTING HIS WORK BEFORE PROCEEDING, AND SHALL DOORS & HARDWARE 5/8 FROM STEEL REPORT TO THE DESIGNER ANY CONDITION WHICH WOULD PREVENT THE F PROPER AND LEGAL COMPLETION OF HIS WORK, NOT REPORTING ANY TOILET HARDWARE ® Q ' 6'-6" 1" BOTTOM 0 SIGN G SUCH UNSUITABLE CONDITION WILL CONSTITUTE ACCEPTANCE OF ALL i 6'-8" @ 9'-0" AFF TYP. CONDITIONS BY THE CONTRACTOR AND/OR SUBCONTRACTOR. TOILET SHEET VINYL FLOOR ® ® Q 6. APPROVAL OF SHOP DRAWINGS MEANS APPROVAL OF THE GENERAL METHOD SLATWALL ® ® MP-1 FLOOR PLAN - MECH'L., SCHEDULE, NOTES U 00 OF FABRICATION ONLY, DIMENSIONS AND QUANTITIES MAY NOT BE W CHECKED, AND APPROVAL OF SHOP DRAWINGS DOES NOT RELIEVE THE ELEVATION -FRONT OF SIG CONTRACTOR FROM COMPLIANCE WITH THE REQUIREMENTS OF THE RUBBER WALL BASE ® MP-2 SPECIFICATIONS, LEGEND = o DRAWINGS AND SPECIFICATIONS UNLESS SPECIFICALLY INDICATED IN THE APPROVAL. FITTING ROOM BENCH a N 7. SEE SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS. WHERE FITTING ROOM HOOKS v DRAWINGS AND SPECIFICATIONS CONFLICT, THE MOST RESTRICTIVE Z SHALL APPLY. FITTING ROOM CURTAIN & HARDWARE Q N ® E-1 PANEL SCHEDULE, NOTES, 8. LANDLORD'S BUILDING SHELL IS FULLY SPRINKLERED CONSTRUCTION. c" 3 5/8 16 GA. PIE FITTING ROOM WALL COVERING SINGLE LINE DIAGRAM 0 0 Ln OF TRACK BET. 9. PROVIDE 2A,10BC MINIMUM RATED FIRE EXTINGUISHER TO BE LOCATED INTERIOR MIRRORS ® E-2 POWER FLOOR PLAN, LIGHTING FLOOR PLAN, STUDS FOR BRACKET L Q ATTACHEMENT WITHIN 75 FEET OF TRAVEL DISTANCE FROM ALL AREAS. PROVIDE ONE Q X EXTINGUISHER FOR EACH 75 FEET OF TRAVEL. CERAMIC TILE FLOOR ( MALL FLOOR ) E-3 SPECIFICATIONS, LEGEND, DETAIL Q o I- 10. PLANS OF ALTERATIONS TO EXISTING SPRINKLER SYSTEM SHALL BE CERAMIC TILE GROUT MALL FLOOR J O cfi / APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION OF ( ) ® �' Q 9" 1�� 60�. 1„ 9'• SIGN B CKETS SYSTEM, SLATWALL CORNER MOULDINGS O a, Q ATTAC D TO PIECE OF 5/8", 16 GA. TRACP 11. DRAPES AND OTHER DECORATIVE MATERIALS SHALL BE FLAME U o CEILING LINE RETARDANT. CERTIFICATION THEREOF SHALL BE PROVIDED. EXITS, STOREFRONT FRAMING & GYP. BD. ® STRUCTURAL DRAWINGS FOR STOREFRONT (SEE STORE FRONT EXIT LIGHTS, FIRE ALARM STATIONS, HOSE CABINETS AND BY AL-FAROOQ CORPORATION UNDER SEPARATE SECTION) EXTINGUISHER LOCATIONS SHALL NOT BE CONCEALED BY DECORATIVE GLAZING /ENTRY DOORS ® ® PERMIT. MATERIAL (UFC 11.204). 12. A "THIS DOOR TO REMAIN UNLOCKED DURING BUSINESS HOURS" SIGN, PAINTING i" STEEL SUPPORT WITH A MINIMUM ONE 1 INCH HIGH LETTERS SHALL BE PROVIDED U _ TUBE ADJACENT TO EXIT DOOR FRONT. PROVIDE INDICATING TYPE LOCKS GLAZING EXTRUSIONS 0 ® Q REMOVABLE BACK ON DOORS. P R O J E C T DATA PLATE 1/8" THICK 13. NO HAZARDOUS MATERIALS, LIQUIDS OR CHEMICALS SHALL BE STORED CASH WRAP STATION co RAW STEEL W/ 00 I CLEAR LAQUER OR USED WITHIN THE SUBJECT BUILDING AS TO REQUIRE A HAZARDOUS FLOOR FIXTURES LEASE AREA: 1,614 t SO. FT. w FINISH CLASSIFICATION PER APPLICABLE BUILDING CODE. Z W 14. ALL INTERIOR WALLS AND PARTITIONS SHALL BE DESIGNED AND SPEAKERS ® HABITABLE AREA: 1,348 f SQ. FT. ? CONSTRUCTED TO RESIST ALL LOADS TO WHICH THEY ARE SUBJECTED ® ® (EXCLUDES WALLS, TOILET, n4° ° ° BUT NOT LESS THAN A FORCE OF 5 POUNDS PER SQUARE FOOT APPLIED ELECTRICAL AND WINDOW DISPLAY AREA) 'Air N PERPENDICULAR TO WALLS. �_ Q i-- BOLT/NUT 1 15. ALL EXITS SHALL BE OPENABLE FROM THE INSIDE WITHOUT THE USE LIGHT FIXTURES ® SALES AREA: 1,213 f SQ. Fr. U) V CL 6'-8" OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. HVAC 40 W O Z ® ® OCCUPANCY LOAD: � Q 16. LIGHT, VENTILATION AND SANITATION SHALL COMPLY WITH SECTIONS PLUMBING ® TENANT'S SHELL SPACE G-14 Q w o 4 ELEVA ON- BACK OF SIGN OF APPLICABLE BUILDING CODES. In U) r 17. DOORS SHALL HAVE A CLEAR OPENING OF NO LESS THAN 32 WHEN OPEN SPRINKLERS SCA . 1 1/2"=1'-0" AND BE OPERABLE BY A SINGLE EFFORT. OCCUPANCY TYPE: RETAIL ` 18. THE FLOOR INSIDE OR OUTSIDE OF A DOORWAY SHALL BE LEVEL FOR SMOKE EVAC. SYSTEM (IF APPLICABLE) A DISTANCE OF 5'-0" FROM THE DOOR, IN THE DIRECTION OF THE FIRE ALARM SYSTEM (IF APPLICABLE) ® TENANT: HOT TOPIC DOOR SWING, AND SHALL EXTEND 18" BEYOND THE LATCH SIDE FOR 18305 SAN JOSE AVE. • INTERIOR DOORS AND 24" BEYOND THE LATCH SIDE FOR EXTERIOR SIGN CITY OF INDUSTRY, CA. 91748 DOORS. ® ® (626) 839-4681 ® 19. SWITCHES AND CONTROLS FOR LIGHTS, VENTILATION, FIRE ALARMS, SPECIALTY METAL (RAW STEEL METAL,ANGLE & FLAT CONTACT: JOHN GATTURNA ov_� ETC, MUST BE PLACED NO MORE THAN 48" FROM THE FLOOR. 20. A 7'-0" MINIMUM VERTICAL CLEARANCE IS REQUIRED FROM THE FLOOR TRIMS, HEX SCREWS, GLAZING EXTRUSION CLADING). PROJECT COORDINATOR. DRV 16466 BERNARDO CTR. DRV., #136 TO CEILINGS OR PROTRUDING WALL FIXTURES. CONSTRUCTION PHONE ® ® SAN DIEGO, CA. 92128 (858) 592-9205 21. PROPOSED TOILET TO MEET HANDICAPPED REQUIREMENTS CONTACT: DEEPAK VORA AS FOLLOWS: a. PROVIDE A SMOOTH, NON-ABSORBENT FLOOR FINISH - SHEET VINYL r WITH A CONTINUOUS 5" HIGH COVE BASE EXTENDING UP THE WALL. VICINITY M A P SCALE: NONE KEY PLAN SCALE: NONE STOREFRONT GYP. BD. b. WALLS WITHIN WATER CLOSET COMPARTMENTS AND WITHIN 2'-0" OF SI tiBRACKET SOFFIT THE FRONT AND SIDES OF URINALS TO A HEIGHT OF 4'-0" SHALL BE FINISHED WITH PORTLAND CEMENT PLASTER OR AN ICBO SEC �D TO APPROVED WATER RESISTANT DRYWALL COVERED WITH CERAMIC TILE 7 1 PIECE 0 33 5/8 , OR OTHER APPROVED COVER MATERIALS. 16 GA. STU c. HOT WATER AND DRAIN PIPES' UNDER LAVATORIES SHALL BE METAL BRACKET INSULATED OR OTHERWISE COVERED. THERE SHALL BE NO SHARP 0 OR ABRASIVE SURFACES UNDER LAVATORIES. 95 d. FAUCET CONTROLS AND OPERATING MECHANISMS SHALL BE OPERABLE EXISTING MAX BACK OF SIGN FRONT OF SIGN WITH ONE HAND AND SHALL NOT REQUIRE TIGHT GRASPING, OR 9 GARAGE (STORE SIDE) (MALL SIDE) PINCHING OR TWISTING OF THE WRIST. 9 0 22. THE NUMBER OF EMPLOYEES PER SHIFT SHALL NOT EXCEED FOUR (4). MIA INTERNATI NAL N LASER CUT LETTERS INTO 1/8" STEEL PLATE W/ AIRPORT MIAMI CITY z u Ln, RiLID PLASTIC VACUUM FORMED LETTERS 23, PROVIDE FIRE STOPPING AT ALL INTERCONNECTIONS BETWEEN IT P ECTING 5/8" PAST STEEL PLATE 41 o a C) U SPCES CONCEALED VERTICAL AND HORIZONTAL A . U CY C �Ln (3) HOONTAL 24. DRAFTS TOPS MUST BE INSTALLED SO THAT THE LONGEST HORIZONTAL > m w_ FLUOR. LI6 T DIMENSION DOES NOT EXCEED 100 FEET. 41 FIXTURE (HW 120V ST MI I CITY 953 (TYP.) 25. PLANS FOR ALL FIXED FIRE PROTECTION EQUIPMENT SUCH AS `� '� STANDPIPES, SPRINKLER SYSTEMS AND FIRE ALARM SYSTEMS, MUST BE SUBMITTED TO, AND APPROVED BY, THE FIRE PREVENTION BUREAU 826 Q 1/8" RAW STEEL P kTE = DATE 7-11 -00 II WITH CLEAR LAQUER F ISH BEFORE THIS EQUIPMENT IS INSTALLED. 1 ON BACK AND FRONT TENANT'S SPACE # G-14 LOCATION'' T SCALE AS SHOWN 6" ENANT SW 72ND ST./SU SET DR. DRAWN SAR SECTION 1 SHOPS AT SUNSET MALL JOB HT-SHPSNSET SOUTH MIAMI CITY SHEET PROJECT ADDRESS: HOT TOPIC �4N T- 1 1 THE SHOPS AT SUNSET PLACE LEVEL 2 5701 SUNSET DRIVE OF SHEETS S. MIAMI, FL. TWO LEVEL MALL