Loading...
00-0781-002 REVISIONS - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - ELECTRICAL NOTES 1 REMOVE AND REINSTALL EXISTING INTERIOR WALL OUTLETS AS SHOWN. IF— — — — — — — — — — — — — — — — — — — — — — — — — — j I tu �n oo oo LU IL — — — —— — — — — — — — — -- - - — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — — —— — — Z+ - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - J Fy� - - - - - - - - - - - - - - -- - DEMOLITION NOTES 1 . ALL MATERIAL I-PPROVED FOR REMOVAL, UNLESS SALVAGED IN ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, SHALL NOT BE REUSED ON THIS PROJECT AND SHOULD BE DISPOSED OF PROPERLY IN — — — — — — — — — -- — — — — — — — — -- - — — — — — — — — — — — — AN APPROVED LANDFILL IN ACCORDANCE WITH THE COUNTY r'l REQUIREMENTS. ►V� '�'a ; 2. WORK AREA SHALL BE KEPT IN CLEAN CONDITION AND FREE FROM HAZARDOUS DEBRIS AND DEMOLISHED MATERIAL. DEMOLISHED AND REMOVED MATERIAL MUST BE DISPOSED OF FROM JOB SITE AS WORK PROGRESSES. — — — — — — — — — — — — — — — — — — — — — —— - 3 . ALL EXISTING CONDITIONS, DIMENSIONS, NON—BEARING INTERIOR WALLS LOCATIONS, PLUMBING AND ELECTRICAL IN CONNECTION WITH THIS WORK MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO THE UU REMOVE EXISTING DAMAGED CONC. DEMOLITION OPERATIONS AND/OR REMOVAL OF ANY SECTIONS OF THE S" GMU LUALL AS 5HOWN 51r UJALK EXISTING BUILDING. IN CASE OF ANY DEVIATIONS FROM THESE PLANS AND SPECIFICATIONS, OR IF A CONDITION ARISES EITHER BEFORE OR HATCHED AREAS DURING THE ACTUAL DEMOLITION WORK AND/OR REMOVAL OPERATIONS THAT AFFECTS THE OBJECTIVE OF THESE PLANS, OR IF IT APPEARS THAT LOAD BEARING BUILDING COMPONENTS AND STRUCTURAL ELEMENTS HAVE BEEN AFFECTED AND COMPROMISED, THE CONTRACTOR SHALL CEASE ALL OPERATION AND NOTIFY THE ENGINEER IMMEDIATELY. 4. A MEANS OF EGRESS FOR FIRE ESCAPE SHALL BE PROVIDED AND CONSTRUCTION NOTES MAINTAINED AT ALL TIMES DURING THIS WORK. 5 . ALL WORK AND DESIGN LOADING FOR ANY TEMPORARY AND PERMANENT 1 REMOVE IMPACT DAMAGED WALL SECTIONS AS INDICATED. SHORING SHALL BE IN ACCORDANCE WITH THE RECENT SOUTH FLORIDA BUILDING CODE DADE COUNTY EDITION, AND ALL COUNTY ADDITIONS 2. REPLACE 8" CMU AS SHOWN AND INSTALL NEW POURED CELLS AS SHOWN AND AMENDMENTS. ON STRUCTURAL PLAN SHEET. 6. DO NOT SCALE DIMENSIONS OR DRAWINGS. t E%/lfpmrNG OVA LL FLOOR PLAYS SCALE: 1/4" = 1'-0' PLUMBING NOTES LLj 1. NO PLUMBING WORK IS REQUIRED UNDER THIS REPAIR WORK. O MECHANICAL NOTES 1. NO MECHANICAL WORK IS REQUIRED UNDER THIS REPAIR WORK. o z SHEET OF