00-0781-001 REVISIONS
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -�
I
I I
I
ELECTRICAL NOTES
1. REMOVE AND REINSTALL EXISTING INTERIOR WALL OUTLETS AS SHOWN.
TEMPORARY SHORING NOTES :
1. PROVIDE 3. 5 TON POST SHORES 3 PLACES AS SHOWN TO REMAIN IN
PLACE UNTIL ALL DAMAGED CMU WALL SECTIONS ARE REMOVED AND
I I REPLACED.
2. LOCATION OF PROPOSED POST SHORES TO CORRESPOND WITH PROPOSED
POURED CELLS.
3 . PROTECT POST SHORES AT ALL TIMES TO PREVENT ACCIDENTAL KNOCK
OUT.
4. POST SHORES SHALL BE INSTALLED PLUMB AND TO BE EQUIPPED WITH
� I 6" SQUARE MINIMUM BASE AND CAP PLATES.
W Cl�
LL
- - - - - - - - - - - - - - -�
I i
- - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -I
- - - - - - - - - - - - - - - - - - - - - - - - - - - - 0
� i SEE SHORING NOTES
TYPICAL
i
i I
I i i - - - - - - - - - - - - - - J DEMOLITION NOTES
1. ALL MATERIAL APPROVED FOR REMOVAL, UNLESS SALVAGED IN
ACCORDANCE WITH THE PLANS AND SPECIFICATIONS, SHALL NOT BE
_ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ _ — — — — — — — — — — — — REUSED ON THIS PROJECT AND SHOULD BE DISPOSED OF PROPERLY IN
r AN APPROVED LANDFILL IN ACCORDANCE WITH THE COUNTY N
31 � � REQUIREMENTS. �
2. WORK AREA SHALL BE KEPT IN CLEAN CONDITION AND FREE FROM T , '•
HAZARDOUS DEBRIS AND DEMOLISHED MATERIAL. DEMOLISHED AND
REMOVED MATERIAL MUST BE DISPOSED OF FROM JOB SITE AS WORK `r W
PROGRESSES.
L - - - - - - - - - - - - - - - - - - - - - - - - - - 31
3 . ALL EXISTING CONDITIONS, DIMENSIONS, NON-BEARING INTERIOR Z ••��••••'4�
51-7"+ — ol WALLS LOCATIONS, PLUMBING AND ELECTRICAL IN CONNECTION WITH Q p
GONG. THIS WORK MUST BE VERIFIED BY THE CONTRACTOR PRIOR TO THE v
REMOVE EXISTING DAMAGED DEMOLITION OPERATIONS AND/OR REMOVAL OF ANY SECTIONS OF THE
N
8" CMU WALL AS SHOWN 5Y WALK EXISTING BUILDING. IN CASE OF ANY DEVIATIONS FROM THESE PLANS (�
HATCHED AREAS AND SPECIFICATIONS, OR IF A CONDITION ARISES EITHER BEFORE OR V�
DURING THE ACTUAL DEMOLITION WORK AND/OR REMOVAL OPERATIONS A
THAT AFFECTS THE OBJECTIVE OF THESE PLANS, OR IF IT APPEARS
THAT LOAD BEARING BUILDING COMPONENTS AND STRUCTURAL ELEMENTS 4
7d-3„+ — HAVE BEEN AFFECTED AND COMPROMISED, THE CONTRACTOR SHALL CEASE 0
ALL OPERATION AND NOTIFY THE ENGINEER IMMEDIATELY.
4. A MEANS OF EGRESS FOR FIRE ESCAPE SHALL BE PROVIDED AND
CONSTRUCTION NOTES MAINTAINED AT ALL TIMES DURING THIS WORK.
5 . ALL WORK AND DESIGN LOADING FOR ANY TEMPORARY AND PERMANENT
1. REMOVE IMPACT DAMAGED WALL SECTIONS AS INDICATED. SHORING SHALL BE IN ACCORDANCE WITH THE RECENT SOUTH FLORIDA
BUILDING CODE DADE COUNTY EDITION, AND ALL COUNTY ADDITIONS
2. REPLACE 8" CMU AS SHOWN AND INSTALL NEW POURED CELLS AS SHOWN AND AMENDMENTS.
ON STRUCTURAL PLAN SHEET. Hot
6. DO NOT SCALE DIMENSIONS OR DRAWINGS. N v D
0\/SP%o4LL FLO® L4\
SCALE: 1/4° = 1'-0"
PLUMBING NOTES
w
1. NO PLUMBING WORK IS REQUIRED UNDER THIS REPAIR WORK. a
I It
Q �
U� O
O
MECHANICAL NOTES
1. NO MECHANICAL WORK IS REQUIRED UNDER THIS REPAIR WORK.
°z
SHEET OF