Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0207-001
Y O U0 ¢ W � ~~` Z OJ c� FRONT �— o 5P Lu `�;�. ci �_ � o ,. Uj 23 �+ W T Y 22 H 15CD SD W m J O X z Q ; 23 W J SYMBOL DESCRIPTION SYMBOL LEGEND for BARINGTON MANUFACTURER N¢ O M¢ 00 0 MODEL QUANTITY GENE R A L NOTES LL :�"��;: 24 FACP FIRE ALARM CONTROL PANEL SILENT KNIGHT 4 EXISTING 1) ALL i WIRING IS 'POWER LIMITED'. SD DACT DIGITAL ALARM COMMUNICATING TRANSMITTER SILENT KNIGHT 5104 EXISTING 2) ALL WIRING AS APPLICABLE SHALL BE CLASS 2: 14/2 18/2 & 18/4 UL FPL CABLE. ©11ocD 3) INSTALLATION SHALL COMPY WITH THE 1999 SFBC/DADE COUNTY & LOCAL AHJ CODES 2D SD21 SD 0 25 PULL STATION STATION ON FLUSH TRIM FIRELITE HG-10 2 SSD SENSOR BASE 4) INSTALLATION SHALL COMPLY WITH NFPA 72 1993, ALL APPLICABLE CHAPTERS SSD PHOTO SENSOR SYSTEM SENSOR 2400 SERIES 13 5) INSTALLATION SHALL COMPLY WITH NFPA 101 1994 ALL APPLICABLE CHAPTERS c L V/0 24VDC XX_CD RED IHZ as Indicated on plan 6) INSTALLATION SHALL COMPLY WITH THE NEC 1999 ALL APPLICABLE SECTIONS P SYSTEM SENSOR SPECTRALERT 6 7) CONDUIT AS REQUIRED SHALL BE 1/2' & 3/4' EMT RACEWAY SIZED FOR MAXIMUM OF 40% WIRE FILL H A/V 24VDC XX_CD RED 1HZ (HORN) as Indicated on plan F 18 P SYSTEM SENSOR SPECTRALERT 4 8) SYSTEM LL BE GROUNDED PER MANUFACTURERS SPECIFICATIONS AND THE NEC 1999 ARTICLE 250 110CD 9) MANUAL PULL STATIONS SHALL BE MOUNTED @ 48' AFF TO TOP OF DEVICE PER ADA AND NFPA 72 1993 ^^^ SD 10) ALL VISUAL DEVICES SHALL BE MOUNTED @ 80' AFF PER ADA & NFPA 72 1993 ^ 17 11) DUCT MOUNTE=D SMOKE DETECTORS AS REQUIRED PER NFPA BOA SHALL BE C❑NNETED TO THE FIRE ALARM 12) SYSTEM COMPONENTS SHALL BE UL LISTED AND SUITABLE FOR FIRE SERVICE USE ^^ ^^^ 13) COST OF THIS PROJECT IS LESS THAN $ 5,000 �1 ^ ^ ^ CLASSROOM PLAY AREA - 14) FIRE REMOTE SYSTEM ANNUNCIATOR SHALL BE MOUNTED AT THE FRONT MAIN ENTRANCE PER PLAN 2 60' AFF I I LLJ PROJECT S C❑P E: 15) THE FIRE ALARM SYSTEM DACT SHALL BE REMOTE STATION MONIT❑RED / 60 HOUR STANDBY BATTERY REQUIRED n- 16) THE FIRE ALARM EVACUATION SIGNAL SHALL SOUND IN A TEMPORAL PATTERN PER NFPA 72 1993 19 THE SCOPE ❑F THIS PROJECT IS T❑ ADD THE PROTECTION AS NOTED T❑ THE 17) ALL FIRE/SMOKE PARTITION PENETRATION(S) SHALL BE SEALED AS REQUIRED, WITH Q C) Q 16 EXISTING FIRE ALARM SYSTEM AT THE ACADEMY, THIS ADDITION IS AT THE REQUEST OF^ ^^^^ SD LISTED APPROVED FIRESTOP COMPOUND, TO MATCH PENETRATED STRUCTURE(S) FIRE RATING 0 ^ MIAMI-DADE FIRE DEPARTMENT CITATION CEILING CHARACTERISTICS: Q z O 15 1K THE CEILINGS LESS THAN 10' AND ARE FLAT ACOUSTICAL TILES, n -110CD 15CD 14 13SD 12SD V J Ln y S D LO ~ s 2 W - I—LJ 3 sn 8 sD FACP STANDBY BATTERY CALCULATIONS 15C © mad SD 75CI © 15CD STANDBY CURRENT ALARM CURRENT MANUFACTURER 1 4 15`D 10 H DEVICE UNIT TOTAL UNIT TOTAL 5 F 0'6 lscn 11 F LU MS-4024 FIRE ALARM CONTROL 1 0,0792 0.0792 0,3400 0,3400 SILENT KNIGHT o PHOTO SMOKE SENSOR 27 0.0001 0,0001 0.0100 0.2700 SYSTEM SENSOR BG-10 MANUAL PULL STATION(S) 6 N/A NIA N/A NIA FIRELITE,INC I a SIGNAL CIRCUIT#1 CANDELA AUDIBLE 4 0.0210 0.0840 SYSTEM SENSOR VISUALS 15 8 0.0530 0.4240 SYSTEM SENSOR VISUAL(S) 75 0 0.1230 0.0000 SYSTEM SENSOR ' VISUAL(S) 110 0 0,1400 0.0000 SYSTEM SENSOR Z TOTAL 1 MAXIMUM 125 amps(75%LOAD=0.937 A) 0.5080 • LU LU a SIGNAL CIRCUIT#2 CANDELA NEW DEVICES BE ADDED AUDIBLE 4 0,0270 0.1080 SYSTEM SENSOR ZONE 3 SMOKE DETECTORS TO EXISTING FIRE ALARM SYSTEM NEW DEVICES TO BE ADDED sD SD sD SD SD sD SD VISUAL(S 15 6 0.0530 0.3180 SYSTEM SENSOR at TO EXISTING FIRE ALARM SYSTEM VISUAL(S) 75 1 0.1230 0.1230 SYSTEM SENSOR VISUAL(S) 110 3 0.1400 0.4200 SYSTEM SENSOR ZONE 4 PULL STATI❑NS V\I- F F F� F F F L L L L L L H H H -j H M .«�^"`° TOTAL 2 MAXIMUM 125 amps(75%LOAD=0,937A) 0.9690 j a � ds o SD SD SD SD SD SD SD SD SD SD L L L H H H H � TOTAL 1 +2 MAXIMUM 2,50 amps(75%LOAD=1.875 A) 1,4770 ZONE 2 SMOKE DETECTORS SD SD SD SD SD .i TOTAL CURRENT U (S) STANDBY 0,079 ALARM 1,477 M NFPA STANDBY BATTERY CALCULATIONS r w ZONE 1 SMOKE DETECTORS Th SD SD SD SD SD �,i, C4 ((TOTAL STANDBY CURRENT x 60 hours)+(TOTAL ALARM CURRENT FOR FACP x 0.084)} + 201/o CONTINGENCY FACTOR Ld STANDBY HOURS REQUIRED/REMOTE STATION 60 Hours STANDBY CURRENT TOTAL 0.079 Amperes FIRELITE MS-4024 z ° FIRE ALARM CONTROL STANDBY BATTERY REQUIRED IN Ah 5,9 A,H � BATTERY SUPPLIED 7 A.H RESERVE CAPACITY OVER MINIMUM REQUIREMENT 1,1 A,H z 17 Ah BATTERY o 0 0 0 GROUND _EL110 VAC DEDICATED 20 Amp CIRCUIT I LL.I O W E— O O �- = c yes SCALE: Sc FILE NO. ` PROJECT NO. � m FIRE ALARM PLAN / RISER / CALCULATIONS SCALE: I/8" = I ' PROJECT NAME: SHEET NO.