Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-1414-016
ERA(3 A E N1 ER ASSOCIATED , ENGINEER 3830 SHIPPING AVENUE TYPE: EXISTING PANEL_ H VOLTS: 1 20/208V-30-4W MIAMI, FLORIDA 33146 : MOUNTING: SURFACE BUS: 200 A EB 0004473 444-8210 MAIN: M.L.O. LOAD: 148 A CLIENT CKT. DESCRIPTION POLES TRIP VOLTS WIRE COND. LOAD REMARKS 1 WATER HEATER 2 30 208 #10 3/4" 3000 EXISTING ' LEGEND : ELECTRICAL GENERAL NOTES 2-6 LIGHTS OUTSIDE (T.C.) 1 20 120 #12 3/4" 6920 EXISTING America's TOGGLE SWITCH, SINGLE POLE. (+48" AFF UNLESS OTHERWISE NOTED.) 1. SITE INVESTIGATION: IT SHALL BE THE RESPONSIBILITY OF BIDDERS TO 7 L,IGHTS LOBBY 1ST FLOOR 1 20 120 #12 3/4" 1200 EXISTING Capital VISIT THE SITE OF THE WORK AND TO ACQUAINT THEMSELVES WITH 8 LIGHTS CORRIDOR 1 20 120 #12 3/4" 925 EXISTING ALL INFORMATION REGARDING THE NEW BUILDING. $3 TOGGLE SWITCH, THREE POLE. (+48" AFF UNLESS OTHERWISE NOTED.) 9-13 LIGHTS PARKING (T.C.) 2 20 208 1 #12 3/4" 1 9100 EXISTING Partners 2. DESIGN: THE INSTALLATION OF THE WIRING SYSTEM SHOWN ON THESE DIMMER SWITCH. (+48" AFF UNLESS OTHERWISE NOTED.) DRAWINGS SHALL CONFORM TO THE REGULATIONS OF LOCAL CODES 14 EXHAUST FAN 1 20 120 #12 3/4" 670 EXISTING D DUPLEX RECEPTACLE, WALL. (+18" AFF UNLESS OTHERWISE NOTED.) AND ORDINANCES, N.E.C. AND LOCAL UTILITY COMPANIES. 15 ROOF KEPT. G.F.I. 1 20 120 #12 3/4" 180 EXISTING 444 Brickell Avenue "GFI" GROUND FAULT TYPE, "WP" WEATHER PROOF. 3. MINIMUM STANDARDS: THE MATERIAL, INSTALLATIONS, AND WORK- 16 LIGHTS LOBBY 2ND FLOOR 1 20 120 #12 3/4" 1280 EXISTING Suite 900 MANSHIP FURNISHED UNDER THIS SECTION SHALL,CONFORM AT TWO DUPLEX RECEPTACLES IN TWO GANG OUTLET BOX "D" DESIGNATION MEANS LEAST TO THE REQUIREMENTS OF LOCAL CODES AND N.E.C. ALL 17 LIGHTS HALL 3RD FLOOR 1 20 120 1 #12 3/4" 1060 EXISTING Miami, FL DEDICATED. (+18" AFF UNLESS OTHERWISE NOTED.) MATERIALS USED SHALL BE LISTED OR BEAR U.L. APPROVAL. 18 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING O DUPLEX RECEPTACLE. FLOOR. 4. GUARANTEE: THIS SUBCONTRACTOR SHALL FURNISH A WRITTEN 19 LIGHTS HALL 4TH FLOOR 1 20 120 #12 3/4" 1060 EXISTING DUPLEX RECEPTACLE IN CAST IRON BOX MOUNTED ON CONDUIT FROM FLOOR. GUARANTEE THAT ALL WORK EXECUTED UNDER THIS CONTRACT SHALL BE FREE FROM DEFECTS OF WORKMANSHIP AND MATERIALS 20 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING FOR A PERIOD OF ONE YEAR FROM THE DATE OF FINAL ACCEPTANCE 21 LIGHTS HALL 5TH FLOOR 1 20 120 1 #12 3/4" 1060 EXISTING SINGLE RECEPTACLE, WALL. (+18" AFF UNLESS OTHERWISE NOTED.) AND THAT HE WILL AT HIS OWN EXPENSE, REPAIR AND REPLACE ALL 22 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING Interior Renovations for Q_ JUNCTION BOX, WALL. WORK WHICH BECOMES DEFECTIVE DURING' THE TIME OF THE GUARANTEE. 23 LIGHTS HALL 6TH FLOOR 1 20 120 #12 3/4" 1060 EXISTING Main Lobby and 5. RACEWAYS AND FITTINGS ARE TO BE USED FOR ALL RACEWAYS. Elevator Cabs at JUNCTION BOX, FLOOR. COMPRESION TYPE FITTING ARE TO BE USED ON E.M.T. SYSTEM. 24 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING 6. CONDUCTORS: THE MINIMUM CONDUCTOR NO. 12 SOLID CU "TW"IN- 25 LIGHTS HALL 7TH FLOOR 1 20 120 #12 3/4" 1060 EXISTING Sunset JUNCTION Box, CAST, MOUNTED ON CONDUIT FROM FLOOR. SULATION. NO MORE THAN THREE CURRENT CARRYING CONDUCTORS SHALL BE INSTALLED IN A RACEWAY. Professional Center 26 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING 0 JUNCTION BOX, CEILING. 27 LIGHTS HALL 8TH FLOOR 1 20 120 #12 3/4" 1060 EXISTING 59'75 Sunset Drive 7. ALL EQUIPMENT LISTED ON THE DRAWINGS BY CATALOG NUMBERS South Miami, FL ` ' O LIGHTING FIXTURE TYPE DESIGNATION. SHALL BE LIMITED TO THE KIND/MANUFACTURE LISTED. NO 28 LIGHTS TOILET 1 20 120 #12 3/4" 1200 EXISTING • SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE 29 RECEPTACLES 1ST 12 1 20 120 3/4" ENGINEER A WRITTEN GUARANTEE OF THREE YEARDS AND CREDIT THRU 4TH FLOOR # 1800 EXISTING . CEILING MOUNTED FLUORESCENT LIGHTING FIXTURE. RECEPTACLES 5TH � (SIZE MAY VARY SEE LIGHTING FIXTURE SCHEDULE.) FROM BASIC BID SHALL BE SUBMITTED WITH BID. 30 THRU 6TH FLOOR 1 20 120 #12 3/4" 1440 EXISTING �... RECEPTACLES 7TH WALL MOUNTED FLUORESCENT LIGHTING FIXTURE. 8. ELECTRICAL INSTALLATION OF THIS PLAN IS IN COMPLIANCE AS SET 31 THRU 8TH FLOOR 1 20 120 #12 3/4 " 1440 EXISTING , FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY 32-3 DRINKING FOUNTAINS 1 20 120 #12 3/4" 4020 EXISTING FLUORESCENT LIGHTING FIXTURE STRIP. CODES 38 EXHAUST FANS 1/6 1 20 120 #12 3/4" 500 EXISTING Project NO . SMOKE DETECTORS IN SUPPLY AND RETURN DUCTWORK OF H.V.A.C. •'} '± O CEILING MOUNTED INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. 9. SHALL BE WIRED TO SHUTT OFF UNIT AND ANNUNCIATE AT ALARM. 39 EXHAUST FANS 1/2 1 20 120 #12 3/4;i 1100 EXISTING 00 -410 ` 40 EXHAUST FANS 1 2 20 208 #12 3/4 WALL MOUNTED INCANDESCENT, CIRCLE OR HID LIGHTING FIXTURE. 10. CONTRACTOR SHALL IDENTIFY BREAKERS IN PANELS BY MEANS OF 1800 EXISTING A TYPED, PLASTIC COVERED DIRECTORY. 41 EXHAUST FANS 1 2 20 208 #12 3/4" 1800 EXISTING = •;, CEILING MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON ® DRAWINGS.) 11. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR 42-43 RECEPTACLES 1 20 120 #12 3/4" 1260 EXISTING WALL MOUNTED EXIT LIGHT SIGN. (PROVIDE ARROWS AS INDICATED ON IN A WORKMANLIKE MANNER AND SHALL BE COMPLETED AND FULLY 44,4 SECURITY DESK 1 20 120 #12 3/4" 1200 EXISTING SPARE E , DRAWINGS.) OPERATIVE TO THE ACCEPTANCE OF THE OWNER AND ENGINEER. 46-47 SPARES 1 20 120 #12 3/4" - EXISTING 4C4,. SELF-CONTAINED EMERGENCY LIGHTING UNIT, WALL. 12. THE DRAWINGS ARE DIAGRAMMATIC INDICATING GENERAL ARRANGEMENT OF INTENTION OF WORK. THEY ARE CONSIDERED SUPPLEMENTARY TO ONE AND 48-52 SPACES 1 - - - TELEPHONE/DATA OUTLET, WALL. THE OTHER. MATERIALS OR WORK NOTED, INDICATED, OR IMPLIED BY ONE O TRADE AND NOT THE OTHER, SHALL BE FURNISHED AND INSTALLED AS j ..,. DATA OUTLET, FLOOR. THOUGH SPECIFICALLY NOTED BY BOTH. VERIFY SPACE CONDITIONS. AN ATTEMPT HAS BEEN MADE TO SEPARATE AND COMPLETELY DEFINE THE CEILING MOUNTED SMOKE DETECTOR. WORK IN SEPARATE DIVISIONS, HOWEVER, SUCH SEPARATION SHALL NOT TOTAL CONNECTED LOAD 53,195 RELIEVE THE CONTRACTOR FROM FULL RESPONSIBILITY OF COMPLIANCE SMOKE DETECTOR, DUCT TYPE. IF THERE ARE CONFLICTS BETWEEN HIS SUB CONTRACTORS/TRADES. �• '�4' COORDINATE WITH OTHERS AS WELL AS PROVIDE TEMPORARY POWER AT OO CEILING MOUNTED HEAT DETECTOR. PROJECT SITE IF NEEDED. 0 FIRE ALARM MANUAL PULL STATION. (+48" AFF UNLESS OTHERWISE NOTED.) 13. CONTRACTOR SHALL BE RESPONSIBLE FOR THOROUGH REVIEW OF ALL PLANS AND SPECIFICATIONS AFFECTING THIS PROJECT AND SHALL D FIRE ALARM FLASHING LIGHT. COORDINATE WITH OTHERS BEFORE THE COMMENCEMENT OF WORK TYPE: EXISTING PANEL_ E VOLTS: 1 20 208V-30-4W r F / - �; . .: SO THAT THE ROUTING OF SYSTEMS AND CLEARANCES SHALL BE MOUNTING: SURFACE BUS: 100 A F FIRE ALARM AUDIO/VISUAL DEVICE. ADEQUATE. ANY CONFLICTS OR DEVIATIONS SHALL BE CALLED TO THE ATTENTION OF THE ENGINEER IMMEDIATELY BEFORE PROCEEDING. MAIN- M.L.O. LOAD: 54 A DISCONNECT SWITCH. Gonzalez—Abreu 14. PRIOR TO COMMENCEMENT OF WORK, VERIFY MEASUREMENTS AT SITE. MAGNETIC MOTOR STARTER. SUBMIT DISCREPANCIES AND DIFFERENCES TO ARCHITECT-ENGINEER FOR CKT. DESCRIPTION POLES TRIP VOLTS WIRE COND. LOAD REMARKS Alas, Inc. CONSIDERATION AND DECISION BEFORE PROCEEDING. VERIFY ALL Architecture IDf COMBINATION MAGNETIC MOTOR STATER & DISCONNECT SWITCH. DIMENSIONS PRIOR TO ANY FABRICATION OR INSTALLATION. 4275 Aurora Street 1-3 LIGHTS EMERGENCY STAIR 1 30 208 #10 3/4" 2640 EXISTING 15. VERIFY EXACT LOCATION OF ELECTRICAL OUTLETS, FIXTURES, PANELS Suite F 0 CEILING MOUNTED SPEAKER, SOUND SYSTEM. AND/OR EQUIPMENT RELATED TO THIS INSTALLATION. COORDINATE WITH 4 ILIGHTS CORRIDOR 1ST FL 1 1 20 120 #12 1 3/4" 1350 EXISTING Coral Gables, Fl. 33146 1 GROUND CONNECTION. ARCHITECTURAL AND MECHANICAL TRADES DESIGN DRAWINGS, AND WITH 5 LIGHTS BALCONY (T.C.) 1 20 120 #12 3/4" 1060 EXISTING ( 305 ) 461 -4573 THE OWNER. FOR EXACT LOCATION OF NEW EQUIPMENT/FIXTURES ETC. SEE RELATED TRADE AND/OR ARCHITECTURAL DRAWINGS. VERIFY VOLTAGE 6 LIGHTS EQ ROOM 1 20 120 #12 3/4" 1000 EXISTING Lie: AA0002495 CONDUIT CONCEALED IN OR UNDER FLOOR SLABS. AND CURRENT CHARACTERISTICS, ETC., OF ANY EQUIPMENT SUPPLIED BY OTHER DIVISION, AND BEFORE ROUGHING-IN FOR ALL EQUIPMENT. 7-8 LIGHTS PARKING 2 20 208 1 #12 3/4" 3475 EXISTING CONDUIT CONCEALED ABOVE CEILING OR IN WALL. NOTIFY ENGINEER OF ANY CONFLICTS. 9 FUEL OIL TRANSFER PUMP 2 20 208 1 #12 3/4" 830 EXISTING HOMERUN TO PANEL. 16. CUT ALL OPENINGS REQUIRED TO ACCOMMODATE THE WORK UNDER THIS 10 LIGHTS HALL 2ND 2 20 208 #12 3/4" 720 EXISTING REVISIONS CONTRACT, AND REPAIR ALL SURFACES, ETC., DAMAGED BY SUCH 11 LIGHTS HALL 4TH FLOOR 2 20 208 #12 3/4" 570 EXISTING FLEXIBLE CONNECTION TO EQUIPMENT. CUTTINGS. GROUT EACH PENETRATION TO RESTORE THE WALL/FLOOR ELECTRIC MOTOR CONNECTION. FIRE RATING INTEGRITY. 12 LIGHTS HALL 5TH FLOOR 2 20 208 #12 3/4" 570 EXISTING 17. PROVIDE GROUNDING CONDUCTOR(S) FOR THE ENTIRE LENGTH OF NON- 13 LIGHTS HALL 6TH FLOOR 2 20 208 #12 3/4" 570 EXISTING © PANEL METALLIC RACEWAYS RUNS. PROVIDE GROUND BUSHING AT EACH END 14 LIGHTS HALL 7TH FLOOR 2 20 208 #12 3/4" 570 EXISTING OF RACEWAY TRANSITION TO METALLIC RACEWAYS. THE GROUNDING 15 LIGHTS HALL 8TH FLOOR 2 20 208 #12 3/4" 570 EXISTING CONDUCTORS SHALL BE TERMINATED IN THE GROUND BUSHINGS. 16-23 TELE. TERM. BD. 2 20 208 #12 3/4" 1440 EXISTING 18. ALL EQUIPMENT LISTED ON THE DRAWINGS BY CATALOG NUMBERS SHALL BE 24 ELEVATOR PANEL 2 20 208 #12 3/4" 3000 EXISTING LIMITED TO THE KIND/MANUFACTURE LISTED. NO SUBSTITUTION SHALL BE ALLOWED UNLESS APPROVED BY THE ENGINEER. A WRITTEN GUARANTEE OF 25 FIRE ALARM PANEL 2 20 208 #12 3/4" 300 EXISTING THREE YEARS AND CREDIT FROM BASE BID SHALL BE SUBMITTED WITH BID. 26 BATTERY CHARGER 2 20 208 #12 3/4" 115 EXISTING 19. CONTRACTOR SHALL SECURE AND PAY FOR ALL FEES, PERMITS, TEST, 27 ELEV. PIT LIGHTS & RECT. 2 20 208 #12 3/4" 750 EXISTING INSPECTIONS, FINES ETC. APPLICABLE TO THIS WORK. 28-29 SPARE 2 - - - - - EXISTING . .3o-,38 SPACES 2 - - - TOTAL CONNECTED LOAD 51,995 File name: DATE IRENE F. FRAGA. « 11-20-00 3830 SHIPPING kV�',hl+ e- . a, MIAMI FLORIDA TEL: (305)44 `f 1� :i y _ SHEET ELECTRI S , iE ` p E — 2 FLA. G 1992 �, 1 l 0 R I � / 3 G.A.A. Inc. 2000 S