00-1414-015 -� FRAGa ENGINEERS
ASSOCIATED
--- ENGINEER
3830- _ SHIP-OINCr AVENUE
MIAMI, - -FLORIDA, 33146
EB 0004473 444-8210
CLIENT
.... .....
GENERAL DEMOLITION NOTES:
CONNECT TO
LOCAL 1. WHERE ELECTRIC LIGHTING FIXTURES, SWITCHES, RECEPTACLES, BOXES, CABINETS, DEVICES, ETC. ARE
EMERGENCY TO BE REMOVED, AND BOXES AND CONDUITS ARE TO REMAIN, ALL CONDUCTORS SHALL BE DE— AmeriCa' S
CIRCUIT E-4 ENERGIZED, DOSCONNECTED AT BOTH ENDS, REVERSED INTO THE BOX, AND THE BOX PLUGGED WITH
CEMENT TER OR OTHER APPROVED MATERIAL AND THE WALL, FLOOR, CEILING AND THE LIKE •
-........ RESTORED TO MATCH THE SURROUNDING FINISH TO THE SATISFACTION OF THE OWNER. WHERE ANY apl al
. ...............-- .. ......... ........ MECHANICAL ITEMS ARE TO BE REMOVED, ALL ABOVE FINISHES TO BE RESTORED ALSO.
,; T
p FQ F E 2. WHERE ELECTRICAL FIXTURES, SWITCHED, OUTLETS, RECEPTACLES, BOXED, CABINETS, DEVICES, ETC.
a ❑ ARE TO BE REMOVED, AND THEIR REMOVAL AFFECTS THE OPERATION OF ANY EQUIPMENT, FIXTURE, Partners
® RECEPTACLE, ETC. THAT IS TO REMAIN (INCLUDING ITEMS THAT MAY NOT BE SHOWN IN THE
CONNECT TO DRAWINGS BUT ARE PRESENTLY EXISTING IN PLACE) THE CONTRACTOR SHALL RECRUIT THEM (INCLUDING
LOCAL LIGHTING BOXES, CONDUIT, WIRES, ETC.) TO RESTORE THEM TO THE ORIGINAL OPERATING CONDITION, ALL AT 444 Brickell Avenue
CIRCUIT I
ADDITIONAL
.... .........
.............................. -1 3 NAL COST TO THE OWNER. Suite 9OO
SD E ......... OPENINGS IN BOXES, CABINETS, PANELBOARDS, ROOFS, WALL, ETC., WHERE SOMETHING IS
UNUSED
......::::::........................ ....................... REMOVED OR PREVIOUSLY EXISTS, SHALL BE PLUGGED OR BLANKED OUT BY APPROVED METHODS, IF Miami, FL
.... ARM REMAIN.
4
FIRE AL THE OPENING IS TO
VOICE ALL EXPOSED CONDUIT, WIRES, OUTLETS, ETC. NOT TO BE REUSED IN THE NEW REMODELED
O o CONTROL. LAYOUT, SHALL BE REMOVED.
E 5. EXISTING PIPE OR CONDUIT RUNS, STUBBING UP THRU FLOORS, IN AREAS WHERE WALLS ARE TO BE
REMOVED, SHALL HAVE THEIR CONDUCTORS DE—ENERGIZED AND REMOVED. CONDUIT CUT—OFF GROUND
E o o FLUSH WITH FLOOR AND PLUGGED WITH CEMENT MORTAR OR ANY OTHER APPROVED MATERIAL. THE
SAME APPLIES WITH EXISTING CONDUITS OR PIPES THAT ARE STUBBING OUT OF WALLS AND FLOORS. Interior Renovations for
6. WHERE PRACTICAL, EXISTING CONDUCTORS AND WIRES THAT ARE IN GOOD CONDITION, MAY BE REUSED Main Lobby and
SD o 0
IN PLACE A N L
INCORPORATED IN THE REMODELED LAYOUT, PROVIDED IT IS OF PROPER SIZE, TYPE OF
E CONDUCTOR AND WITH THE APPROVAL OF THE OWNER. Elevator Cabs at
7 ABANDONED CIR CUI T CONDUCTORS IN PANELBOARDS, SHALL BE DISCONNECTED, TA PED AND IDENTIFIED.
Sunset
® 8. SALVAGED ITEMS SHALL BE RETURNED TO THE OWNER, AND DELIVERED WHERE DIRECTED BY HIM. ITEMS
AND MATERIALS CONSIDERED UNSALVAGEABLE BY THE OWNER, SHALL BE DISPOSED OF AS DIRECTED BY Professional Center
. .... SWITCHES, DIFFUSERS, RECEPTACLES AND LIGHTING OR PLUMBING
:
p p FIXTURES SHALL NOT BE REUSED CIN NEW CONSTRUCTION. 5975 Sunset Drive
0 0' 9. ALL ROOF OPENINGS OR WALL OPENINGS WHERE MECHANICAL OR ELECTRICAL DEVICES OR OTHER
....... South Miami,
L
FINISHED TO A FINAL FIN
ISH, AND 1711, F
ITEMS ARE TO BE REMOVED SHALL BE RESTORED AND FIN h .
0 0 0 0 10. IN
WATER GENERAL,PROOFED. LIGHTING, SWITCHES, PO E
.. CES,MTOGETHER WILL
WITH ASSOCIATED WIRE AND FCONDUIT PER THE (ABOVE DESCRIPTION IN
THE ALARM DEVICES,
ENTIRE AFFECTED AREA.
o o' o 0 11 THE ELECTRICAL DEMOLITION IS FURTHER..
............................... .,;..........................................? DESCRIBED IN THE GENERAL DEMOLITION PLANS.
Project No.
10
CONNECT NEW
FIXTURES TOII `,
CIRCUIT FEEDING
......... ......... . ..:.::::::::::::::::::::::::::::::::........... ......:::::::::::::::::::::...............
EXISTING CABS
LIGHTS (TYPICAL OF
3 CABS)
i
T
�f
H-44,45
VC TO TELECOM.
J CLOSET
1.5
NOTES;
j N
1• "E" DESIGNATION INDICATES AN EXISTING
DEVICE. ALL EXISTING DEVICES SHOWN
SHALL REMAIN, IF POSSIBLE. IF NOT, THEY
SHALL SE REPLACED IN THEIR EXISTING
LOCATIONS.
2.
EXIT SIGNS SHALL 13E LITHONIA Gonzalez
LRP-X-RW-X-120 WITH MOUNTING AS CENTRAL CONTROL
REQUIRED.
STATION- Alas, Inc .
3 FIXTURE TYPE "A" SHALL BE LIGHTOLIER E
Architecture
CAT. NO. 31124-103�o WITH 15 W MR16 LAMP. 4275 Aurora Street
4• FF Suite F
FIXTURE " " '>u
RE YPE 8 TO BE SPECIFIED. Coral Gables, FI. 33146
5 ( 305 ) 461 —4573
REFER TO ARCHITECTURAL DRAWINGS FOR
DEMOLITION PLANS. ", Lie: AA0002495
REVISIONS
DO NOT PJ,—TA-T L FipE A
LARK
1 ?ar2r r�F
4 vN
Fire Ai sI aIF
be sup 1e c 2Ya
Dad:,
-._
rev c�raYuili�.�; rirut e ily!
File name:
I NE;;F FRAGA
383,0 SHIPPING -AVENUE DATE
MIAMI_. FLORID�A,�-33I4 p 11-20-00
NEW ELECTRICAL PLAN TEL: (305)`4v -� � ,'� t
j
N ELECTRICAL SHEET
1/4"=11-0" FLA. RrG` 1 *.
di
E - 1
G A A Inc 2000
a
..:�j"p�
, A t
1