Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-0441-028
- REVISIONS BY ZE 04/14/00 Z _ 0 P1t1- P1`1L _ 122000 AZC) A AA = W 0 J9 2 200 �� --------------------- 200 3% THM (CU) - 1"C - ------ wp OW rA Ld 00 LZ 1 L1 /GFI A-11 A-11 o A-11 Cf) � 3 A-8 A-9 © I O 't 1= A-8 T_ N 303/0 TI•NAd (CU) - 2"C i�t (CU) 0 BE D R #3 Q A-13 A-9 � to 1 0 La 120/24OV, Its,3W BED 04 CV ^ � p o Lo 3 3/0 n0l (CU) - 20C _8 A-41 J A-9 AN BOX A-10 A-10 f— QD W W / ) O f/1 FAN BOX 6 J W Z La © A-41 ------------ ----------------------� A-10 = O W o O U 5/8°x10 F1: -14 � I I � � Z v -� � DA-8 A-8 ® A-9 A-11 FAN BOX O = O 01IF(METAL) (�► v -13 A-9 � ; A-41 � Z < = X � Z Q A-13 S MAST SUITE O � w LL p E A-13 ® I M J ......_. w U CATION 4 W O A-10 Z _._._._._.—._:_._.—. o -14 L-----------------------------------J O \_� A-8 RISER DIAGRAM A-11 GALLEP 0 S 1 :D 311 H :D d V103103 12 0 N TS A-13 O O A-11 i i A-10 A-10 O 8 I � Z = EL_ ECTF� ICAL. NOTES - - - - - - - - - - - - = oN W f = I. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE - --- 1 A-1 1 A A-41 1 O NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. A-11 I L'— A-12 I N ALA i1 TOP A-12 =_ __'i 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT v Z COMPANY. O 4A� B LGO 1' _ _ _ _ _ _ _ _� o r N 3. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIANCE AS SET FORTH BY STATE OF FLORIDA STATUTES MODEL D 0 $._ ENERGY EFFICIENCY CODES. 120/240V DO ISLE VOLU -1: "_ 1RFA M.L.O. 1 PH, 3W PANEL AA SURFACE MTD \ I 0 W 4. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED A-14 o ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO CKT. NO. DESCRIPTION C/B TRIP LOAD WIRE CONDUIT REMARKS J w = SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION, A-1i \ A_12 3 AS REQUIRED. 1,3 GARAGE/OPENERS 1P-20 1200 #12 ROMEX FAN BOX \ ZZ � STER ATHROOM � O METHODS SHALL NOT BE 2 GARAGE/OUTSIDE LTG 1P-15 800 #14 ROMEX Q 5. SUBSTITUTE MATERIALS EQUIPMENT R M GARAGE/O E \ Q � u- o MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A I P– / LH t-4 4 WH RPOOL 1 20 1200 #12 ROMEX GFI ^t SUBSTITUTE REQUIRES ANY CHANGE IN WORK THE NECESSARY FOR O VP SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- 5,6 LTG/REC 1P-15 #14 ROMEX A 12 A - O 9 NEER AND IF APPROVED, SHALL BE MADE AT NO COST TO THE A-12 ® o , A- 2 --� W W OWNER 7,9 POOL EQUIP. 2P-20 1600 #12 IN 1/2" COND. TIMER I 8 POOL LIGHT 1 P-20 600 12 IN 1 2" COND. GFI � � 3 w U 6. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND # / ; 2"x18" ; I —� t--t ° LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED ACCESS ; I QC u" CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, 10-12 SPACE UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. oMyI 1 I 1 , W I I 1 , � w Q v I I I I A--Y--�L 0 . 0 J � MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET w, , , � Q WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- O TOTAL: � O TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, 5soo (23A) I I I I f VI' z Z UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER. z I I I I W = I I I I O r 8. ALL CONDUCTORS SHALL BE COPPER AND RUN IN CONDUIT. WIRE I I I o SIZE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE Q ° GROUND CONDUCTOR PER NEC 250-95. ; ; O Ti cn I f— Q #--1 = q a. I Z W 9. LOCATION OR OULETS IN ELECTRICAL DRAWINGS IS DIAGRAMMATIC: i i i 1 U H W CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 11 I � w z Z a 10. PROVIDE TYPEWRITTEN SCHEDULES FOR ALL PANELBOARDS. ' ' ' ~ w I � 3 dJ W 11. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON A/C EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- I I I a REVERSE TRACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER " AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, ; ------------------------------------;---------------------- ; W IL Lo MODEL AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. '--'-----'-----'--""---'-------------L-----------------------' CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA Wr 4 COST. HACK CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE ,! o NON-AUTOMATIC SWITCH FOR A/C COND. DISCONNECT. AHU TO HAVE -A SCALE BUILT-IN DISCONNECT (COMPLY NEC 110-16) V 12. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CHECKED BY R.C . o GKT (KITCHEN OR BATH LTG.) 5 COI D FL OO FL AN _ L CTF 1CAL m y `� I DRAWN BY G.C . _ 13. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL GROUNDING � W WIRE PER NBC: 250-60 Zn CZn �/`"1'll = 11—OIL i DATE 1 ve 06/01/99 W 14. APPLIANCES LOAD ARE SHOUN AS MAXIMUM TO BE INSTALLED o JOB 9(028 W J - WIRES TO BE SIZED ACCORDING TO NAME PLATE DATA. a IT SHALL BE PERMISSIBLE TO CHANGE GKT. NO. WITHOUT CHANGING i W QUANTITY OF CIRCUITS SHEET 1n w W S Cc w LL W Z S OF SHEETS (� W `O r 0� GUERRERO/GONZALEZ ENGINEERS, INC. - � , Michael C. Guerrero, P.E. Mechanical Eng. Lic. #15235 Rafael L. Gonzalez, P.E. fY Electrical Eng. Lic. #11057 , 11420 N. Kendall Dr., Suite 200 } t �� Miami, Florida 33176/-�� ; sE' Tel. (305) 595-8525, Fax (305) 596-9077 &ANA +iL No ''`7: 7 1 2,+ i