00-0422-003 90111'11 FLORMA B m.DIN.CODE(REVISED 1994)
WOOD FENCE DESIGN DETAIL
N.T.S.
ALL NAILS AND CONNECTORS
SHALL BE GALVANQED
2X4 No.3 P.T.WOOD RAILS(3)
MIN. ATTACHED TO WOOD POST
W1TH MIN.(4)10d NAILS
4X4 No.2 P.T.WOOD POST
FENCE HEIGHT POST
ABOVE GRADE SPACING
4'-0"olc
S-0"o/c
4'-0" V-0"a/c
WOOD PICKETS,518'MIN.DRESSED
THICKNESS. ATTACH EACH PICKET
TO RAIL WITH(2)18 GA.STAPLES
1-314'LONG. `
1 Z'DIA.CONCRETE FOOTING = • `-
O
i
• 4
Supplement No.3 29-33-2