00-0404-011 I LL F- ELECTRICAL NOTES: ----------v 1. DO NOT SCALE ELECTRICAL DRAWINGS. REFER TO ARCHITECTURAL PLANS o AND ELEVATIONS FOR EXACT LOCATIONS OF ALL EQUIPMENT AND CONFIRM a WITH OWNER'S REPRESENTATIVE. 2. ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE N.E.C. AND SHALL 4 _ COMPLY WITH ALL LOCAL RULES AND ORDINANCES. O U 0 ° 3. MINIMUM WRE SIZE SHALL BE NO. 14 AWG., EXCLUDING CONTROL WIRING. 0 N UNLESS OTHERWISE INDICATED, ALL CONDUCTORS SHALL BE COPPER WTH w TW INSULATION FOR SIZES NO. 6 AND SMALLER. CONDUCTORS LARGER oc THAN NO. 6 SHALL HAVE TYPE THW INSULATION. ALL CONDUCTORS N0. 10 AND SMALLER MAY BE SOLID. ALL THOSE No. $ AND LARGER KITCHEN FAMILY BATH ® BATH MASTER ° SHALL BE STRANDED. EQUIVALENT ALUMINUM CONDUCTORS CAN BE USED z I IN SUBFEEDERS NO. 6 OR LARGER IF APPROVED BY LOCAL REGULATIONS. Lw CONTRACTOR TO VERIFY. 4. ALL RACEWAYS AND PIPES PLACED IN OR THRU ANY CONCRETE SLAB SHALL BE SPACED A MINIMUM OF 3 DIAMETERS OF THE LARGEST CONDUIT OR PIPE OF ANY OTHER SERVICE. 5. ALL RACEWAYS UNDERGROUND AND/OR LARGER THAN 2 INCHES IN I I O DIAMETER, SHALL BE GALVANIZED RIGID STEEL PVC PIPE SCH.40 WILL BE J w N N C ACCEPTABLE IF APPROVED BY LOCAL REGULATIONS. CONTRACTOR TO VERIFY. ALL OTHER RACEWAYS 2 INCHES AND SMALLER IN DIAMETER MAY Wo� �C BE E.M.T. i LOW WALL . N N E 6. OUTLET BOXES SHALL BE PRESSED STEEL IN DRY LOCATIONS, AND CAST _ ALLOY WTH THREADED HUBS IN WET OR DAMP LOCATIONS. . _ _O 7. NOT USED. - ! 39 --- ' — Q _ W 0 0 8. IT IS NOT THE INTENT OF THESE PLANS TO SHOW EVERY MINOR DETAIL ; � � Z = OF CONSTRUCTION. THE CONTRACTOR IS EXPECTED TO FURNISH AND 010 INSTALL ALL ITEMS FOR A COMPLETE ELECTRICAL SYSTEM, AND PROVIDE GARAGE DINING LIVING RM. BEDROOM 2 ' ' C� rn O 0 ALL REQUIREMENTS NECESSARY FOR EQUIPMENT TO BE PLACED IN PROPER ® i i a� O Q 9. WORKING ORDER. � BEDROOM 3 � NOT USED. O 0 41 i Z 10. THE ELECTRICAL SYSTEM SHALL BE COMPLETELY AND EFFECTIVELY e i i • i GROUNDED AS REQUIRED BY THE LATEST EDITION OF THE N.E.C. 0 11. NOT USED. W 0 I-- � U) N 39 U J o>I 39 LL 0) o 12. ALL MATERIAL SHALL BE NEW AND SHALL BEAR UNDERWRITERS AND w UNION LABELS WHERE APPLJCABLE. w • L) 13. ALL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR I COV. ENTRY Q IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETED SYSTEM 3 0 0 SHALL BE FULLY OPERATIVE AND ACCEPTANCE BY ENG./ARCH. MUST BE A CONDITION OF THE CONTRACT. 39 U Z 14. ALL WORK SHALL BE COORDINATED WITH OTHER TRADES TO AVOID O INTERFERENCE WTH PROGRESS OF CONSTRUCTION. ry 06X _ 15. CONTRACTOR SHALL GUARANTEE ALL MATERIALS AND WORKMANSHIP FREE COJLL OF DEFECT FOR A PERIOD OF NO LESS THAN ONE YEAR FROM THE DATE OF ACCEPTANCE. a MEX IS AN ACCEPTABLE OPTION. f�.• � o A �j• 17. NOT USED. r .`p E I- ELECTRI CAL PLAN ECt . 1 /4 W U SUIVICE TYPE NEUTRAL,BUS: 200 AMP. ELECTRICAL PLAN LEGEND z VOLTAGE : 240/120V 1/ - 3w PANEL: A MSS' : 2� AMP MOUNnNG: LOCATION ; SHOYN Q DUPLEX RECEPTACLE LIGHT SWITCH W AMPS POLES HARE DESCRIPn0N CKT. CI(T. DESCRIPnON VARE POLES AMPS SINGLE RECEPTACLE 3-WAY LIGHT SWITCH EXSTING 1 2 EXISTING W EXISTING 3 4 EXISTING 1p POLED DUPLEX RECEPTACLE CEILING MOUNTED FIXTURE EXISTING 5 6 EXISTING V) w EXISTING 7 8 EXISTING SPECIAL RECEPTACLE Q WALL MOUNTED FIXTURE 11// �� ly- DOSTING 10 ENSTING GA W EXISTING 9 12 D OSTING GRND. FAULT INTERRUPT DUPLEX ® RECESSED CEILING FIXTURE Q EXISTING 13 14 EXISTING 0 EXSTING 15 16 EXISTING GARAGE DOOR OPENER T TELEPHONE JACK fy EXISTING 17 18 EXISTING 0 EXISTING 19 20 EXISTING Z EXHAUST FAN TELEVISION JACK 0 0 EXISTING 21 22 EXISTING EXISTING 23 24 EXISTING tl ELECTRIC PANEL SMOKE DETECTOR EXISTING 25 26 EXISTING LL EXISTING 27 28 EXISTING M3 ELECTRIC METER 4 PUSH BUTTON z (n — EXISTWG 31 30 EXISTING C' DISCONNECT SWITCH 1� DOOR BELL EXiSTWG 31 32 EXISTING 0 LO E OSTING 35 36 DOSTWG } HOSE BIB (GROUND) WP WEATHER PROOF Q EXISTING 37 38 EXISTING 20 1 12 1 RECEPTACLES 39 20 70 EXTERIOR LIGHT J BOX E=.3 UNDER CAB. LIGHT Q REC. +102' JOB No. 0009�� rCAD FILE: MONTI DATE: 4-12-00 r