00-0270-023 CARLO S FIGUEROA -L...__.---_• -_:_"----------_.-.__.__.'I it I, ALL WORK SHALL BE DONE IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE, DADE COUNTY EDITION, AND ALL APPLICABLE LOCAL ORDINANCES. i� CONNEGT.TO EXIS7.ING. . j 7o9B CONDENSATE DRAIN I 2. ALL WORK SHALL BE PERFORMED BY A LICENSED PLUMBING CONTRACTOR PIPING IN MECHANICAL ROOM i IN A FIRST CLASS WORKMANLIKE MANNER. THE COMPLETE SYSTEM SHALL BE FULLY OPERATIVE. (._____... _-__.___. ___.._------_-----.-_:j ' I i 3. PLUMBING CONTRACTOR SHALL FURNISH WRITTEN GUARANTEE THAT ALL ! I ! ❑ ❑ ! I PLUMBING WORK SHALL BE FREE OF DEFECTS OF MATERIALS AND i WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM FINAL ACCEPTANCE. I 1 I A R C H I T E CT U R E i INTE=RIOR DESIGN it 4_ CONTRACTOR SHALL VISIT THE 51TE AND FIELD VERIFY LOCATION OF EXISTING I POINTS OF CONNECTIONS BEFORE SUBMITTING BID AND OBTAIN CLARIFICATION I =aEi-' I'''' i "- "-" "-' -- - °---iij rq4 .�_..._...__._...__.I. ;. i j� A R b O O 9 8 4 4 j �..I I �......_ j - - -'- BEFORE COMMENCING WORK I'll _•-, I 70; B 4080 SW 84th AVENUE r'----.-. I si_. i MIA FLORIDA 33155 5. CONTRACTOR SHALL BECOME FAMILIAR WITH ALL EXISTING CONDITIONS -- -----------------.-:-----.__-._..._; L__-- 305 220 8997 --------'-- - - ----- - --- I., AND NOTIFY ARCHITECT/ENGINEER OF ANY DEVIATION DUE TO FIELD CONDITIONS BEFORE PERFORMING WORK. 6. CONTRACTOR SHALL COORDINATE LOCATION AND 51ZE OF ALL PENETRATIONS THROUGH WALLS, CEILINGS, FLOOR AND ROOFS WITH OTHER TRADES AND 4 - -'- - -'- -- - '- - --- - '- REPORT ANY DISCREPENCIES t0 ARCHItECT/ENGINEER. ' . C 11/2"al/4'/Ft I ;i ! I ..��1 �. DRAWINGS ARE DIAGRAMMATIC. DO NOT SCALE DRAWINGS FOR THE EXACT / I /� ,j `� u 6 • u�' IJ LOCATION OF FIXTURES AND PIPING. I! �! A4-4U-10 it AHU-II ;� a. CONTRACTOR SHALL BE RESPONSIBLE FOR ALL PERMITS, TAXES, INSPECTION -- `!I iI '! j' '` U- r AND TEST FEES. i ' - S. MATERIALS SHALL BE NEW, FREE OF DEFECTS AND OF AMERICAN I i PROVIDE A CONDENSATE ;; `` o arc, MANUFACTURE, AS FOLLOWS: DRAIN PUMP EQUAL TO LITTLE ji GIANT vCM I5UL-50Gf::5H 0 5' A. ABOVE GROUND WASTE AND VENT PIPING SHALL BE BELL AND SPIGOT 7pH-115V/I4,160 30 WATTS OR "NO HUB' STANDARD WEIGHT CAST IRON, WROUGHT IRON OR COPPER " (SUPPORT FROM WALL ABOVE PIPE. IF PERMITTED BY GOVERNING CODES AND ACCEPTED BY OWNER, ,Ij CEILING) I !j SCHEDULE 40 A55 OR (DWY) PVC MAY BE USED. _ I ................. j B. WASTE PIPING SHALL BE BELL AND SPIGOT STANDARD WEIGHT CAST IRON, WROUGHT IRON OR COPPER PIPE. IF PERMITTED BY GOVERNING !j l CODES AND ACCEPTED BY OWNER, SCHEDULE 40 ABS OR (DWV) PVC MAYBE USED .IN LIEU OF CAST IRON.. i C. WATER PIPING: COPPER TYPE "L" WITH A5TM 8-16, LEAD-FREE SOLDER. ?I jl !� 4 10- P. WALL CLEANOUTS: JOSAM SERIES 5850 WITH ACCESS COVER OR it r------- - - — - - - ---� I EQUAL. ! i j!j ! j E. VALVES: 125 PSI NIBCO SCOTT, STOCKHAM OR EQUAL. ! !� 10. PERFORM THE FOLLOWING TESTS: A. NEW WATER PIPING SHALL BE HYDROSTATICALLY TESTED AT 100 i! !` _._-_--- --- __.. P51G FOR A PERIOD OF NO LESS THAN ONE HOUR.' i i G ;i B. WASTE AND VENT PIPING SHALL BE FILLED WITH WATER TO A 10 FOOT °°° v.,,,n. ,. .: v_:,, v.e4 x .. v,._ �,,, ,.. ,� ,,. .`a -,: _,.I,.,,x ,.Rn, :,_ :.., ,,. -,.� m :,.. ,. , ,.x ,.. .., ..., �. . ._, m HEAD AND ALLOWED TO STAND UNTIL THE WATER LEVEL REMAINS a CONSTANT. 701( 702( 703( 704( C. CORRECT ALL DEFECTS DISCLOSED BY ABOVE TESTING. D. STERILIZE ALL NEW WATER PIPING WITH A MIXTURE OF TWO (2) ' 4 POUNDS OF CHLORINATED LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN MIXTURE IN PIPE FORA PERIOD OF 24 HOURS AND FLUSH THOROUGHLY WITH POTABLE. WATER BEFORE PLACING SYSTEM IN SERVICE. � f' �` , %' ;' ,:: ,` 11. WASTE PIPING 2' AND SMALLER SHALL BE SLOPED AT 1/4" PER FOOT MINIMUM, PIPES LARGER THAN 2' SHALL BE SLOPED AT I/8' PER FOOT MINIMUM ® �' FALL. ANY DEVIATION SHALL BE APPROVED BY ARCHITECT/ENGINEER 12, INSULATE ALL .AIR CONDITIONING AND REFRIGERATION CONDENSATE N 7TIf FLOOR PLUMBING PLAN (AREA C DRAIN WITH 3/4' INCOAFLEX. FINISHED WHERE EXPOSED WITH 2 COATS ` OF WHITE LATEX PAINT ALL AS PER MANUFACTURER'S INSTRUCTION. SCALE: 1/8" _ ' 1 ' - 0'" 13. PIPING PENETRATIONS AT ROOFS, CEILINGS, FLOORS AND WALL SHALL BE SEALED AIR AND WATER TIGHT. WHERE PENETRATING FIRE RATED CONSTRUCTION, FIRE 5AFED TO PROVIDE PROTECTION MATCHING REQUIRED RATING. ~� F-'-d 14. ALL VENT PIPING SHALL BE SO GRADED AND CONNECTED AS TO DRAIN DRY, NO POCKETS OR LOW POINTS SHALL BE CREATED IN THE VENT LINES WHICH MAY PREVENT VENTING IF FILLED WITH CONDENSATION. 9 10 15. CEILING ACCESS PANELS SHALL BE PROVIDED FOR VALVES INSTALLED � 1--4 ABOVE OTHERWISE NON-ACCESSIBLE CEILINGS, 1 2 2' MIN { 1' MINIMUM 16 ALL AROUND . PRECAUTIONS SHALL BE TAKEN t0 PREVENT CONTAMINATION OF OWNER. I EQUIPMENT, FURNITURE AND CARPETING WITHIN THIS BUILDING. COVER AND WRAP EQUIPMENT, FURNITURE AND CARPETING AS CD NECESSARY. DUST AND DEBRIS SHALL BE STRICTLY CONTROLLED. -•-- p W �y CLOSE COORDINATION WITH OWNER WILL BE REQUIRED. I-1. WHERE REQUIRED, EXISTING CEILINGS SHALL BE REMOVED TO MODIFY SLOPE 1/8' /FT 5 4 8 3 THE EXISTING PLUMBING SYSTEMS_ THESE CEILINGS SHALL BE 6 ►-�1 REPLACED TO MATCH ADJACENT SURFACES. I-Ld A /C UNIT DRAIN PAN 8c W E-4 CONDENSATE TRAP DETAIL N.T.S. NOTES: OREFER TO PLAN FOR CONDENSATE DRAIN PIPING SIZES OCONDENSATE DRAIN FROM A/C UNITS SHALL BE ADEQUATELY INSULATED IN ATTICS AND PLENUM SPACES AND/OR WHEREVER DAMAGE TO PROPERTY OR Revisions EQUIPMENT MAY RESULT FROM SWEATING. OAUXILIARY DRAIN PIPING TO TERMINATE.OVER SINK,LAVATORY,OR OTHER.APPROVED LOCATION WHERE DISCHARGE WOULD BE NOTICED WITHOUT CAUSING DAMAGE AND/OR HAZARD.TERMINATE FLUSHED WITH CEILING. ® FLOAT SWITCH WHEN USED INSTEAD OF OR IN ADDITION TO AUXILIARY PAN DRAIN SHALL BE.WIRED TO SHUT DOWN.THE AIR CONDITIONING SYSTEM WHEN THE . FLOW SWITCH OPENS. OP-TRAP(2'MINIMUM WATER SEAL UP TO 3 TONS,3' MINIMUM SEAL OVER 3 TONS OF A/C) OFLOAT SWITCH OAUXILIARY PAN DRAIN 3/4' MINIMUM DEPTH,24 GA GALVANIZED SHEET METAL. OREMOVEABLE THREADED PLUG OR DRAIN COCK ONLY WHEN ALTERNATE FLOAT SWITCH I5 PROVIDED. O Job No. Sheet No. REMOVEABLE CAP. IO UNION (TYPICAL) Date 11 MATERIALS AND INSTALLATION TO BE AS INDICATED AND PER SOUTH 09/09/99 p ® 1 1 FLORIDA BUILDING CODE,DADE EDITION AND LOCAL AUTHORITIES. Puga .and Associates, Inc. Engineers/Consultants Drawn by C # EB 0005813. GSR/GLM 4970 S.W. 72 Avenue, #107 Appr. by Miami, Florida 33155 JDP of (305) 661-7700 .J