00-0270-014 CARLO S FIGUEROA HEAT F::>Ul-lf= UNIT '5CHE-RULE GAUGE CONNECTION LEGEND UNIT NUMBER EXISTING HVAC DE5IG�N fREOUIIRES- 'T'ES NO AHU-6 AHU-10 AHU-II VENT TYPE WATER WATER WATER DUCT SMOKE DETECTOR \\ 12x12 RECTANGULAR DUCT INSIDE DIMENSIONS ' COOLED COOLED . COOLED Q THERMOMETER WELLS (TYP) GWR MODEL NO. HE-1200 H5-120 HS-120 4_5�n FIRE DAMPER(S)FLEXIBLE ROUND DUCT INSIDE DIMENSIONS SEE SEE SEE BALANCING VALVE � ISOLATION AREA SERVED 1 .VALVES ,0,00-- PLAN PLAN PLAN� —� VOLUME DAMPER SMOKE-DAMPER(6) Q CWS o VD TOTAL AIR SUPPLY CFM 3400 3200 3500 ❑ ❑ ' I FIRE RATED ENGLOSGRE ' ./ SUPPLY AIR, CEILING MOUNTED REGISTER OUTSIDE AIR GFM 460 360 480 ® ARCHITECTURE I ® FIRE RATED ROOF/FLOOR I N-T E R I O R DESIGN TOTAL STATIC PRESSURE W.G. --- --- --- CEILING ASSEMBLY RETURN AIR, CEILING MOUNTED REGISTER ___ .a R o 0 0 9 s 4 4 FIRE STOPPING 4080 SW 84th AVENUE EXTERNAL STATIC PRESSURE W.G. 1.25 1.25 0 MIAMI, FLORIDA 33155 �\ I J �A THERMOSTAT 305 220 8997 j� I � MOTOR HORSEPOWER HP --- 3 3 SMOKE CONTROL Q / GAUGE CONNECTION —o COMBINATION FIRE DAMPER AC UNIT �1/ I FD ELECTRICAL CHARACTERISTICS V/O/Hz 4aO13160 48013160 48013160 -! E DRAIN O/A OUTSIDE AIR r i DN. DOS I IR D15TfRIE3UTION 5 F HEATING CAPACITY BTUH --- --- --- <: J UNION OR FLANGES (TYP) -- 21.6 21.6 r,•�� r •• J' •. S/A SUPPLY AIR MCA/MOCP N-V� ' r, ••' *'' SYMBOLS SIZE. MFGR MODEL SERIES REMARKS C CW5 CONDENSING WATER SUPPLY PIPING GRAND TOTAL HEAT BTU/HR 120,000 119,000 119,005 " iL O 24x24 TITUS PAS-AA-O5D-5'0 NK SUPPLY CONDENSER CONNECTION � TIL CWR CONDENSING WATER RETURN PIPING TOTAL SENSIBLE HEAT BTU/HR 109,600 85,100 85,100 NTS MD MANUAL DAMPER ENTERING AIR TEMPERATURE OF DB/°F WB 85 _10.1 161.1 BO 24x24 TITUS PAS-AA-050-10"O NK SUPPLY 6I 63.4 63.4 HEATING ENTERING WATER °F /°F -- -- -- O 24x24 TITUS PA6-AA-O5D-12",P NK SUPPLY 'CJ SD SMOKE DETECTOR WATER TEMPERATURE -- -- -- �, WATER FLOW GPM 34 15.5 15.5 ( p j 24x24 TITUS PAS-AA-05D-14`0 NK SUPPLY NEW FULLY CONCEALED TYPE SPRINKLER HEADS. 85 85 85 O RELOCATED EXISTING SPRINKLER HEAD DROPS AT WATER TEMP. ENT./LEAV. °F AT NEW LOCATIONS AS INDICATED. ADD.NEW HEADS 95 95 95 E 24x24 TITUS PAS-AA-05D-16'O NK SUPPLY AND DROPS WHERE REQUIRED. ADJUST TO NEW MAXIMUM COIL PRESSURE DROP FT. H2 O 7 5.4 5.4 CEILING HEIGHT AND LAYOUT AS REQUIRED. O EER / GOP 10.3 11.2 11.2 3.3 4.5 4.5 D 0 . ESIGN MANUFACTURER FHP CLIMATE CLIMATE MASTER MASTER O MINIMUM ROWS / MAXIMUM FINS PER INCH 3 3 3 14 . 14 14 COMPRESSOR FLA --- 19.E 19.E 1 24x24 TITUS SOFF-AA RETURN NOTES: NOTES: I. COMPRESSORS SHALL HAVE A 5-YEAR EXTENDED WARRANTY. . 2. A SMOKE DETECTOR SHALL BE INSTALLED IN THE S/A DUCT OF UNITS IN ACCORDANCE WITH 1 REFER TO PLAN FOR QUANTITY, LOCATION AND AIR THROW PATTERN. NFPA 95A. SMOKE DETECTORS ARE SPECIFIED UNDER ELECTRICAL. F 3. THERMOSTATIC EXPANSION VALVES SHALL HAVE A BROAD MODULATING RANGE. EXTERNAL EQUALIZING LINES SHALL BE TAPPED INTO SUCTION LINES DOWNSTREAM OF THE EXPANSION I I VALVE G BULBS. OUT 5 r 1D AIR R C A P I T U L A T I O N � 4. UNITS SHALL ALL HAVE 1° THICK FLAT THROWAWAY FILTERS LOCATED IN UNIT MOUNTED FILTER RACK. 5. INSTALL UNITS ON EXTERNAL SPRING. ISOLATORS. Co. UNITS SHALL BE COMPLETE WITH LOW PRESSURE SWITCH, ANTI-SHORT CYCLE TIMER AND TOTAL OUTSIDE ROOM THERMOSTAT WITH AUTOMATIC CHANGEOVER NET.5Q.FT. OUTSIDE AIR UNIT NO. AREA SERVED NO-PEOPLE, CFf1/PERS'ON AIR/UNIT CGFM) REMARKS 7. UNIT AHU-6 15 EXISTING TO REMAIN. MIN. USED EXISTING AHU-6 --- 23 20 460 465 NEW AHU-10 --' 18 20 360 360 NEW AHU-11 '-- 24 25 480 480 LOW VELOCITY SUPPLY AIR DUCT (SEE PLAN VIEW) �I MANUAL VOLUME DAMPER AIR SEAL JOINT FLOW 6� WITH DUCT INSULATE FLEXIBLE DUCT SEALER 4 SUPPORT AS REQUIRED W TAPE FOR LENGTH SAG. MAXIMUM 1 OUTDOOR AIR-PROVISIONS FOR VENTILATION SHALL SATISFY THE MINIMUM MANUAL VOLUME LENGTH 15'-O O DAMPER REQUIREMENTS FOR ACCEPTABLE INDOOR AIR QUALITY PER ASHARE 62-1989. SUPPORT CROSS p'-d ANGLE (2 1/2"x2 1/2'x1/4") DRAW BAND AIR FLOW SPIN COLLAR FITTING WITH 1� p EXTRACTOR t DAMPER W/ E-+ ' DOUBLE LOCKING NUTS QUADRANT OPERATOR TO BE 12 GAGE (MIN) WIRE ' (TYPICAL) OUTSIDE INSULATION PROVIDE INSULATION GUARD WHERE STRUCTURE 1 1/2" MIN. HANGER STRAPS SUPPORT FROM EXISTING INSULATED s VAPOR NECESSARY. SUPPORT FROM EXISTING SPIN COLLAR W/ SEALED COLLAR t DIFFUSER 1/2" EXPANTION BOLT DAMPER AND BACK PANEL STRUCTURE (26 GAUGE) y� INTO EXISTING STRUCTURE HANGER ROD EXTRACTOR . SEAL JOINT WITH DUCT . p� (3/44 THREADED) SEALER 6 TAPE ii o A.H.0 BELLOW DIFFUSER FIBROUS DUCT VIBRATION t ISOLATION m 61 ` FIBROUS ROUND AND FLEXIBLE SHEET METAL DUCT ` Revisions f A.H.0 BELLO SADDLE MIN.- R 5'-0" ON CENTER 6' MIN. NOTE: PLACE SUPPORT AT S'-0" (2) 1 1/2' xl 1/2' (12ga) DUCT ON CENTER FOR DUCTS UP NOTE:UN16TRUT GALVANIZED FL E X 15L E GOV V EECT O N DETAIL TO 35" AND 6'-O" FOR DUCTS DOUBLE LOCK STEEL ANGLE UP TO 59", AS PER SMACNA HANGERS SHALL BE LOCATED AT NUTS N.T.S. 2 x2 xl/8 DUCT JOINTS OR AS CLOSE AS GALVANIZED POSSIBLE. TOP HUNG BOTTOM HUNG CHANNEL A.H.U. MANGER PETAIL5 FECTAN_:;ULAR DUCT SUFFORT DETAIL F�,'®UNIT DUCT SUFFOST [DETAIL N.T.S. N.T.S. N.T.S. Job No. Sheet No. Date 09/09/99 M® 2 Puga and Associates, Inc. Engineers/Consultants Drawn by # EB 0005813 GSR/GLM 4970 S.W. 72 Avenue, #107 Appr. by Miami, Florida 33155 JDP 2 of 3 (305) 661-7700