00-0270-003 ❑ ❑
ARCHITECTURAL .ABBREVIATIONS ARCHITECTURAL SYMBOLS GENERAL NOTES CARL®S
� � _ FIGUEROA
ARC H ITECT
AB ANCHOR BOLT IN INCH � BLDG. CORE WALL &/OR EXISTING CONSTRUCTION
ABV ABOVE 1. THE WORK SHOWN ON THESE PLANS, (ALSO REFERRED TO AS CONTRACT DOCUMENTS), AND HEREIN SPECIFIED IS
INCL INCLUDE(D)(ING) INTENDED TO INCLUDE ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE PROJECT IN ITS ENTIRETY, WHETHER
A/C AIR CONDITIONING INS INSULATE(D),(ION) BASE BUILDING COLUMN SHOWN, DESCRIBED, REASONABLY IMPLIED, REQUIRED, OR INFERRED.
ACOUS ACOUSTICAL INT INTERIOR
ACT ACOUSTICAL TILE 2. THE CONTRACTOR SHALL VISIT AND INSPECT THE SITE TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR
ADD ADDENDUM NEW INTERIOR GYP. BD. PARTITION TO BID. ANY CONFLICTS OR DISCREPANCIES BETWEEN OBSERVED EXISTING CONDITIONS AND THE PLANS SHALL BE
ADH ADHESIVE JAN JANITOR SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BID.
ADJ ADJACENT JC JANITOR'S CLOSET REFERENCE TO TYPE ❑
ALT ADJUSTABLE LAB LABORATORY TO BE DEMOLISHED REGARDING OALLAPHASES OFLTHE WORK IINCBLUDINGRDEMOLITION, DEBRIS HREMOVAL,DELIVERY OF EWCMATERIALLSBWORK G ARCHITECTURE IR DEE
ALT ALTERNATE HOURS, UTILITY HOOKUPS, ETC., AND SHALL MAKE ALL ARRANGEMENTS TO FACILITATE THE TIMELY COMPLETION OF THE INTERIOR DESIGN
ALUM ALUMINUM LAM LAMINATED WORK.ANC ANCHOR, ANCHORAGE LAV LAVATORY A R o 0 0 9 8 4 4
NEW INTERIOR GYP. BD. PARTITION WITH 2x4 BLOCKING, SEE PLAN FOR
ANOD ANODIZED LBL LABEL HEIGHT AND LOCATION 4. ANY DAMAGE TO THE EXISTING BUILDING INCLUDING ITS INTERIOR, PARKING AREAS, IMMEDIATE EXTERIOR PUBLIC 4080 sw 84th AVENUE
.
AP ACCESS PANEL LH LEFT HAND RIGHT-OF-WAYS, MECHANICAL SYSTEMS, ELEVATORS, FINISHES AT PUBLIC CORRIDORS, AND LOBBIES SHALL BE REPAIRED MIAMI, FLORIDA 33155
APPROX APPROXIMATE LT LIGHT ELEVATION DATUM POINT
AT CONTRACTOR'S EXPENSE. 305 220 8997
ARCH ARCHITECTURAL 5. THE CONTRACTOR SHALL NOT DETERMINE ANY DIMENSION NOT SPECIFICALLY NOTED ON THE PLANS BY SCALING
ASPH ASPHALT MACH MACHINE 25 DOOR NUMBER SUCH PLANS. WRITTEN DIMENSIONS SHALL PREVAIL IN THE EVENT OF CONFLICT.
AUTO AUTOMATIC MAG MAGAZINE 6. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL, COUNTY, STATE, AND FEDERAL
AVG AVERAGE MAT MATERIALS) 2 ELEVATION LAWS REGULATING CONSTRUCTION, CONSTRUCTION SAFETY, AND LABOR. "
MAX MAXIMUM t
BD BOARD MECH MECHANICAL(AL) A_3 ALL WORK ORK SHALL CONFORM TO THE SOUTH FLORIDA BUILDING CODE AND THE CITY OF SOUTH MIAMI ZONING CODE.
BKT BRACKET MFR MANUFACTURE(ER) ���•
SHEET NUMBER 7 . ����'.• ��,� '; •;,�i�y�,;
8. ANY REVISIONS NECESSARY DUE TO A VARIANCE BETWEEN APPLICABLE LAWS, ORDINANCES AND REGULATIONS, AND
BLDG BUILDING MIN MINIMUM THESE SPECIFICATIONS AND DRAWINGS SHALL BE SUBMITTED TO CARLOS FIGUEROA, P.A. FOR APPROVAL BEFORE SUCH
BLKG BLOCKING MISC MISCELLANEOUS 6 SECTION -
BM BEAM MTD MOUNTED A-2 SHEET NUMBER WORK Is PERFORMED. r J
CAB CABINET
NA NOT APPLICABLE
CG CORNER GUARD L
CLG CEILING
NIC NOT IN CONTRACT (tc
CLR CLEAR(ANCE) NO NUMBER (a—SHEET DETAIL
CLO CLOSET NOM NOMINAL NUMBER
NTS NOT TO SCALE
CMU CONCRETE MASONRY UNIT OC ON CENTER /ALIGN
COL COLUMN OD OUTSIDE DIAMETER
ALIGN W/ESTABLISHED SURFACE cn
COMP COMPRESS(ED),(ION),(IBLE) OFF OFFICE
CONC CONCRETE OPNG OPENING 5 —DETAIL
CONF CONFERENCE OPP OPPOSITE A-4 —SHEET NUMBER
CONST CONSTRUCTION ►�
CONT CONTINUOUS, CONTINUE cn
CORR CORRIDOR PBD PARTICLE BOARD
CTR COUNTER PERF PERFORATE(D) DETAILED AREA
CPT CARPET P.LAM. PLASTIC LAMINATE
CT CERAMIC TILE PLAS PLASTER
CTR CENTER PNL PANEL
PTD PAINT(ED)
DBL DOUBLE PR PAIR
PSF POUNDS PER SQUARE FOOT F
DEMO DEMOLISH, DEMOLITION PSI POUNDS PER SQUARE INCH
DEPT DEPARTMENT C
DTL DETAIL PT PRESSURE TREATED
DF DRINKING FOUNTAIN PTN PARTITION
DIAG DIAGONAL PLYWD PLYWOOD
DIA DIAMETER
DIM DIMENSION QTY QUANTITY
DISP DISPOSAL RAD RADIUS
DN DOWN RA RETURN AIR
DR DOOR RE REINFORCE(D),(ING)
DW DISHWASHER REF RECESSED E N I N DWG DRAWING REF REFERENCE INDEY'X_ O F DRAWING-TS
DWR DRAWER REFR REFRIGERATOR
EA EACH REQ'D REQUIRED
EL ELEVATION REV REVISIONS),REVISED
ELEC ELECTRICAL RFL REFLECT(ED),(IVE),(OR)
ELEV ELEVATOR RH RIGHT HAND SEE ENGINEERS DRAWINGS
EMERG EMERGENCY RL RAILING
EQ EQUAL
EQUIP EQUIPMENT RM ROOM A— 1 C COVER
EWC ELECTRIC WATER COOLER RO ROUGH OPENING
EWH ELECTRIC WATER HEATER SC SOLID CORE A— 2 C ABBREVIATIONS, SYMBOLS,
EXST EXISTING SCH SCHEDULE KEY PLAN, & INDEX
EXT EXTERIOR SEC SECTION
FA FIRE ALARM SHT SHEET Sim
FAB FABRICATED SIM SIMILAR D 1 C DEMOLITION PLAN �' ;4
FAP FIRE ALARM PULL SNT SEALANT
FD FLOOR DRAIN SPEC SPECIFICATION(S) A—3 C ARCHITECTURAL PLAN E-4
FE FIRE EXTINGUISHER SQ SQUARE
FECR FIRE EXTINGUISHER CABINET REC. SS STAINLESS STEEL
FECSR FIRE EXTINGUISHER CABINET SEMI-REC. STD STANDARD t
FF FINISHED FLOOR STG . SEATING A-4C REFLECTED CEILING cn
STL STEEL
FHC FIRE HOSE CABINET STO STORAGE
FIN FINISH(ED) A- 5 C DETAILS
FIXT FIXTURE SUSP SUSPENDED STR STRUCTURAL (,� E �T
l�i l �J A- 6 C FINISH SCHEDULES,
FLAM FLAMMABLE SYM SYMMETRY(ICAL) C/�
FLG FLASHING
FLR FLOORING) DETAILS, & SPECIFICATIONS
FOC FACE OF CONCRETE TEL TELEPHONE C�
FOF FACE OF FINISH TEMP TEMPERED
FLUOR FLUORESCENT THK THICK(NESS)
M- 1 C MECHANICAL PLAN
FO FRAME OPENING THR THRESHOLD
FOM FACE OF MASONRY TKBD TACKBOARD
FOS FACE OF STUDS TOIL TOILET M-2 C DETAILS, NOTES AND SCHEDULES
FR FIRE RATED TV TELEVISION
FS FULL SIZE TYP TYPICAL
FT FOOT, FEET TZ TERRAZO 2' x 2' ACOUSTICAL TILE CEILING M- 3C; MECHANICAL SPECIFICATIONS Revisions
FUR FURRED(ING)
FWC FABRIC WALLCOVERING
UC UNDERCUT
GA GAGE, GAUGE UL UNDERWRITER'S LABORATORY
GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE E - 1C POWER FLOOR PLAN
GD GRADE, GRADING 2x2 FLUORESCENT LIGHT FIXTURE
GKT GASKET(ED) VB VINYL BASE E-2 C ELECTRICAL FLOOR PLAN
GL GLASS, GLAZING VCT VINYL COMPOSITION TILE
GMU GLASS MASONRY UNIT VERT VERTICAL
GN GENERAL NOTES VEST VESTIBULE E — 3 C NOTES AND SCHEDULES.
GWB GYPSUM WALLBOARD VWC VINYL WALLCOVERING
GYP.BD. GYPSUM BOARD
GALV GALVANIZED WC WATER CLOSET/TOILETS P — 1 C PLUMBING FLOOR PLAN.
WD WOOD
HC HOLLOW CORE WIN WINDOW
HCP HANDICAPPED WO WITHOUT
Job No. Sheet No.
HDB HARDBOARD WSCT WAINSCOT
HM HOLLOW METAL
HR HOUR
Date
HT HEIGHT
HVAC HEATING/VENTILATING/AIR COND. 02/00 A— 2 C
Drawn by
GSR
Appr. by
CF 2 of 6