Loading...
00-0270-003 ❑ ❑ ARCHITECTURAL .ABBREVIATIONS ARCHITECTURAL SYMBOLS­ GENERAL NOTES CARL®S � � _ FIGUEROA ARC H ITECT AB ANCHOR BOLT IN INCH � BLDG. CORE WALL &/OR EXISTING CONSTRUCTION ABV ABOVE 1. THE WORK SHOWN ON THESE PLANS, (ALSO REFERRED TO AS CONTRACT DOCUMENTS), AND HEREIN SPECIFIED IS INCL INCLUDE(D)(ING) INTENDED TO INCLUDE ALL LABOR AND MATERIALS NECESSARY TO COMPLETE THE PROJECT IN ITS ENTIRETY, WHETHER A/C AIR CONDITIONING INS INSULATE(D),(ION) BASE BUILDING COLUMN SHOWN, DESCRIBED, REASONABLY IMPLIED, REQUIRED, OR INFERRED. ACOUS ACOUSTICAL INT INTERIOR ACT ACOUSTICAL TILE 2. THE CONTRACTOR SHALL VISIT AND INSPECT THE SITE TO FAMILIARIZE HIMSELF WITH EXISTING CONDITIONS PRIOR ADD ADDENDUM NEW INTERIOR GYP. BD. PARTITION TO BID. ANY CONFLICTS OR DISCREPANCIES BETWEEN OBSERVED EXISTING CONDITIONS AND THE PLANS SHALL BE ADH ADHESIVE JAN JANITOR SUBMITTED TO THE ARCHITECT IN WRITING PRIOR TO BID. ADJ ADJACENT JC JANITOR'S CLOSET REFERENCE TO TYPE ❑ ALT ADJUSTABLE LAB LABORATORY TO BE DEMOLISHED REGARDING OALLAPHASES OFLTHE WORK IINCBLUDINGRDEMOLITION, DEBRIS HREMOVAL,DELIVERY OF EWCMATERIALLSBWORK G ARCHITECTURE IR DEE ALT ALTERNATE HOURS, UTILITY HOOKUPS, ETC., AND SHALL MAKE ALL ARRANGEMENTS TO FACILITATE THE TIMELY COMPLETION OF THE INTERIOR DESIGN ALUM ALUMINUM LAM LAMINATED WORK.ANC ANCHOR, ANCHORAGE LAV LAVATORY A R o 0 0 9 8 4 4 NEW INTERIOR GYP. BD. PARTITION WITH 2x4 BLOCKING, SEE PLAN FOR ANOD ANODIZED LBL LABEL HEIGHT AND LOCATION 4. ANY DAMAGE TO THE EXISTING BUILDING INCLUDING ITS INTERIOR, PARKING AREAS, IMMEDIATE EXTERIOR PUBLIC 4080 sw 84th AVENUE . AP ACCESS PANEL LH LEFT HAND RIGHT-OF-WAYS, MECHANICAL SYSTEMS, ELEVATORS, FINISHES AT PUBLIC CORRIDORS, AND LOBBIES SHALL BE REPAIRED MIAMI, FLORIDA 33155 APPROX APPROXIMATE LT LIGHT ELEVATION DATUM POINT AT CONTRACTOR'S EXPENSE. 305 220 8997 ARCH ARCHITECTURAL 5. THE CONTRACTOR SHALL NOT DETERMINE ANY DIMENSION NOT SPECIFICALLY NOTED ON THE PLANS BY SCALING ASPH ASPHALT MACH MACHINE 25 DOOR NUMBER SUCH PLANS. WRITTEN DIMENSIONS SHALL PREVAIL IN THE EVENT OF CONFLICT. AUTO AUTOMATIC MAG MAGAZINE 6. ALL WORK SHALL BE CARRIED OUT IN ACCORDANCE WITH ALL APPLICABLE MUNICIPAL, COUNTY, STATE, AND FEDERAL AVG AVERAGE MAT MATERIALS) 2 ELEVATION LAWS REGULATING CONSTRUCTION, CONSTRUCTION SAFETY, AND LABOR. " MAX MAXIMUM t BD BOARD MECH MECHANICAL(AL) A_3 ALL WORK ORK SHALL CONFORM TO THE SOUTH FLORIDA BUILDING CODE AND THE CITY OF SOUTH MIAMI ZONING CODE. BKT BRACKET MFR MANUFACTURE(ER) ���• SHEET NUMBER 7 . ����'.• ��,� '; •;,�i�y�,; 8. ANY REVISIONS NECESSARY DUE TO A VARIANCE BETWEEN APPLICABLE LAWS, ORDINANCES AND REGULATIONS, AND BLDG BUILDING MIN MINIMUM THESE SPECIFICATIONS AND DRAWINGS SHALL BE SUBMITTED TO CARLOS FIGUEROA, P.A. FOR APPROVAL BEFORE SUCH BLKG BLOCKING MISC MISCELLANEOUS 6 SECTION - BM BEAM MTD MOUNTED A-2 SHEET NUMBER WORK Is PERFORMED. r J CAB CABINET NA NOT APPLICABLE CG CORNER GUARD L CLG CEILING NIC NOT IN CONTRACT (tc CLR CLEAR(ANCE) NO NUMBER (a—SHEET DETAIL CLO CLOSET NOM NOMINAL NUMBER NTS NOT TO SCALE CMU CONCRETE MASONRY UNIT OC ON CENTER /ALIGN COL COLUMN OD OUTSIDE DIAMETER ALIGN W/ESTABLISHED SURFACE cn COMP COMPRESS(ED),(ION),(IBLE) OFF OFFICE CONC CONCRETE OPNG OPENING 5 —DETAIL CONF CONFERENCE OPP OPPOSITE A-4 —SHEET NUMBER CONST CONSTRUCTION ►� CONT CONTINUOUS, CONTINUE cn CORR CORRIDOR PBD PARTICLE BOARD CTR COUNTER PERF PERFORATE(D) DETAILED AREA CPT CARPET P.LAM. PLASTIC LAMINATE CT CERAMIC TILE PLAS PLASTER CTR CENTER PNL PANEL PTD PAINT(ED) DBL DOUBLE PR PAIR PSF POUNDS PER SQUARE FOOT F DEMO DEMOLISH, DEMOLITION PSI POUNDS PER SQUARE INCH DEPT DEPARTMENT C DTL DETAIL PT PRESSURE TREATED DF DRINKING FOUNTAIN PTN PARTITION DIAG DIAGONAL PLYWD PLYWOOD DIA DIAMETER DIM DIMENSION QTY QUANTITY DISP DISPOSAL RAD RADIUS DN DOWN RA RETURN AIR DR DOOR RE REINFORCE(D),(ING) DW DISHWASHER REF RECESSED E N I N DWG DRAWING REF REFERENCE INDEY'X_ O F DRAWING-TS DWR DRAWER REFR REFRIGERATOR EA EACH REQ'D REQUIRED EL ELEVATION REV REVISIONS),REVISED ELEC ELECTRICAL RFL REFLECT(ED),(IVE),(OR) ELEV ELEVATOR RH RIGHT HAND SEE ENGINEERS DRAWINGS EMERG EMERGENCY RL RAILING EQ EQUAL EQUIP EQUIPMENT RM ROOM A— 1 C COVER EWC ELECTRIC WATER COOLER RO ROUGH OPENING EWH ELECTRIC WATER HEATER SC SOLID CORE A— 2 C ABBREVIATIONS, SYMBOLS, EXST EXISTING SCH SCHEDULE KEY PLAN, & INDEX EXT EXTERIOR SEC SECTION FA FIRE ALARM SHT SHEET Sim FAB FABRICATED SIM SIMILAR D 1 C DEMOLITION PLAN �' ;4 FAP FIRE ALARM PULL SNT SEALANT FD FLOOR DRAIN SPEC SPECIFICATION(S) A—3 C ARCHITECTURAL PLAN E-4 FE FIRE EXTINGUISHER SQ SQUARE FECR FIRE EXTINGUISHER CABINET REC. SS STAINLESS STEEL FECSR FIRE EXTINGUISHER CABINET SEMI-REC. STD STANDARD t FF FINISHED FLOOR STG . SEATING A-4C REFLECTED CEILING cn STL STEEL FHC FIRE HOSE CABINET STO STORAGE FIN FINISH(ED) A- 5 C DETAILS FIXT FIXTURE SUSP SUSPENDED STR STRUCTURAL (,� E �T l�i l �J A- 6 C FINISH SCHEDULES, FLAM FLAMMABLE SYM SYMMETRY(ICAL) C/� FLG FLASHING FLR FLOORING) DETAILS, & SPECIFICATIONS FOC FACE OF CONCRETE TEL TELEPHONE C� FOF FACE OF FINISH TEMP TEMPERED FLUOR FLUORESCENT THK THICK(NESS) M- 1 C MECHANICAL PLAN FO FRAME OPENING THR THRESHOLD FOM FACE OF MASONRY TKBD TACKBOARD FOS FACE OF STUDS TOIL TOILET M-2 C DETAILS, NOTES AND SCHEDULES FR FIRE RATED TV TELEVISION FS FULL SIZE TYP TYPICAL FT FOOT, FEET TZ TERRAZO 2' x 2' ACOUSTICAL TILE CEILING M- 3C; MECHANICAL SPECIFICATIONS Revisions FUR FURRED(ING) FWC FABRIC WALLCOVERING UC UNDERCUT GA GAGE, GAUGE UL UNDERWRITER'S LABORATORY GC GENERAL CONTRACTOR UNO UNLESS NOTED OTHERWISE E - 1C POWER FLOOR PLAN GD GRADE, GRADING 2x2 FLUORESCENT LIGHT FIXTURE GKT GASKET(ED) VB VINYL BASE E-2 C ELECTRICAL FLOOR PLAN GL GLASS, GLAZING VCT VINYL COMPOSITION TILE GMU GLASS MASONRY UNIT VERT VERTICAL GN GENERAL NOTES VEST VESTIBULE E — 3 C NOTES AND SCHEDULES. GWB GYPSUM WALLBOARD VWC VINYL WALLCOVERING GYP.BD. GYPSUM BOARD GALV GALVANIZED WC WATER CLOSET/TOILETS P — 1 C PLUMBING FLOOR PLAN. WD WOOD HC HOLLOW CORE WIN WINDOW HCP HANDICAPPED WO WITHOUT Job No. Sheet No. HDB HARDBOARD WSCT WAINSCOT HM HOLLOW METAL HR HOUR Date HT HEIGHT HVAC HEATING/VENTILATING/AIR COND. 02/00 A— 2 C Drawn by GSR Appr. by CF 2 of 6