00-1397-024 lice .. n n FEKiCi.. �' ON^� N G No AIR CON u HVAC DESIGN REQUIRES. YES n ^ ^ ^fin^ N TES : ZUBILLAGA DESIGN Inc.G E N E R � _ 3191 CORAL WAY. SUITE 403 Duct Smoke Detector X ^ _ ___ ^ MIAMI. FLORIDA . 33145 Fire Damper(s) TEL, 305,-443-8180 Cam, Smoke Damper(s) 1. ALL EXHAUST DUCT SHALL BE CONSTRUCTED- OF SHEET ? Fire Rated Enclosure METAL, TERMINATE OUTSIDE THE,•BUILDING, AND BE 43 2�. Fire Rated. R Ceilin Assembly X EQUIPPED :T—FIN ALLOWED)-A BACK DRAFT DAMPER., FAMILY ROOM Fire Stopping X ARCHITECTURE Smoke Control ` X 2. DUCTS FROM TOILET ROOMS SHALL DISCHARGE TO THE CER71FlC11TION No. AA0003o02 OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH FLOOR SURFACE, a AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2 INCH. (PROVIDE NATIONS)GOOSE NECK OR RAIN CAP ON ROOF - 3. CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. n '�+ ��++ 4. CLOTHES DRYERS EXHAUST DUCT (OR VENTS) SHALL A/C EQUIPMENT SCHEDULE COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS, " BE CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, I I UNIT NUMBER A/H HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS RUNNING IN THE DIRECTION OF THE AIR FLOW. d�- I I AREA SERVED SEE PLAN DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET I I METAL SCREWS OR OTHER FASTENERS WHICH WOULD M TOTAL AIR SUPPLY 1000 EXTEND INTO THE DUCT. J KITCHEN BATH BEDROOM u< OUTSIDE AIR CFM 0 GENERAL I I DINING ROOM u- - i I PROVIDE ( FURNISH AND INSTALL ) ALL NECESSARY g EXTERNAL STATIC PRESSURE -IN W.G.- 2 MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL Q 160CFM I I 160CFM " i I 10X6" FAN MOTOR HPIFLA 1/3 4.4 AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS g 10X6 SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED i I ELEC. CHARACTERISTICS V/ HZ/0 208/230-60-01 INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA o BUILDING CODE, ASHRAE, SMACNA, NFPA, AND LOCAL � ORDINANCES. "till 29600 ____ p COOL. COIL CAP. -BTU/HR- w " .�" 75CFM exhaust fan with back towels SCOPE OF WORK w ' LAUNDRY ROOM Q6 flex U TOTAL SENSIBLE HEAT - BTU/HR- 21200 �. �� PROVIDE THE FOLLOWING COMPLETE SYSTEMS draft damper. Provide a 06 z sheet metal duct gauge 26 to ` ex. p ENT. AIR TEMP. -F DB/ F WB-° A. SUPPLY DUCT SYSTEM. roof cap. SEE DETAIL. BATH a.h•u• o RCHA36A1 B. EXHAUST SYSTEM FOR BATHROOMS U MODEL NUMBER C. `AIR CONDITIONING UNITS WITH REFRIGERANT PIPING 0 00 220CFM UNIT MANUFACTURER RHEEM AND CONTROLS. *�`° ►�~ 87CFM 10X8" - MODEL NUMBER RBHA-17J07 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION o 06 flex 10X6 = CHARGES REQUIRED. 92 p` 40CFM wall type dryer exhaust. • 8x6x6" duct board ¢ WEIGHT -Ibs.- • ,� 04"flex 8X4" VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS o � � .�,��• SEE DETAIL t, MCA/MFS COOLING AND EQUIPMENT SIZES PRIOR TO DUCT FABRICATION OR E 06 ex �-Q18"flex MCAIMFS HEATING INSTALLATION. COORDINATE REQUIREMENTS TO AVOID " BEDROOM C/U INTERFERENCE WITH OTHER TRADES. .. refrigerant and drain lines. d 06"flex LIVING ROOM UNIT NUMBER SEE A/H INST.DETAIL. r,: H GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALSa ' y' z LOCATION ON SLAB WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM .,. . ..�,: M AND W DATE OF ACCEPTANCE. 20x20"wall type grille c0' AMBIENT TEMP. °F 92 0 AM to return plenum. ? MATERIALS w m ` 26CFM Z ALL ALIT_ DUCTWORK TO BE R-6. ° s „ 4"flex 8X4" D COMPR./COND. FAN FLA ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. °- D6 flex z PROVIDE HANGE S FOR FLEXIBLE DUCTS OF SHEET METAL p 26 GAUGE, 1-1/2 WIDE AT 5' MAX. SPACING BETWEEN 220CFM U ELEC. CHARACTERISTICS V/Hz/0 208/230-60-01 �� O SUPPORTS. anchored to 10X8 RHEEM PROVIDE HANGERS FOR FIBROUS�,G ASS DUCTS OF SHEET ' DATE: 10-25-00 87CFM w UNIT MANUFACTURER concrete slab. 10X6" 08 flex PLAY ROOM BATH O METAL GAUGE 26 OR ANGLE IRON, `ADEQUATELY SPACED. SEE DETAIL. p MODEL NUMBER . RALB-030JAZ PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL REVISIONS: M r s WIN U SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR 0Y WEIGHT -lbs.- 169 INSTALL SINGLE THICKNESS INSTEAD. W.I.C. Q A„ STORAGE PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY FRONT PORCH REMARKS OUTLET AND AT EACH DUCT BRANCH. SYSTEM (S)EER 11.4 REFRIGERANT PIPING. SEAMLESS COPPER TYPE L AND P HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH - LIQUID/SUCTION SIZE-IN 3/8” X 3/4" WROUGHT COPPER SOLDER. INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2" = ELECTRIC HEATER -KW- 7 CLOSED CELL POLYETHYLENE PRE MOLDED PIPE SCALE: 1/4" = V-0" INSULATION, WITH AN APPROVED PIPE AND SMOKE �� 1 /4�� = 1 d� JACKET. PAINT ALL EXPOSED INSULATION WITH TWO E C H � ` N I C A L P BEDROOM COATS OF WHITE LATEX N PROVIDE AIR ND T 0NING (UNITS WITH MATCHING LOW BY: VOLTAGE HEAT—COOL THERMOSTATS WITH ON—OFF AUTO SUB—BASE SWITCH, FURNISHED BY THE EQUIPMENT JUAN J. ZUBILLAGA MANUFACTURER. REG. ARCHITECT AIR HANDLER INSTALLATION n.t.s. ALL AIR CONDITIONING COMPRESSORS SHALL BE AR 14147 -- WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE 03/8" OD liquid line 16"X10" R-6 ductwork OF ACCEPTANCE OF THE PROJECT. f' 3 u to main trunk 03/4" OD suction line p AIR DISTRIBUTION PRODUCTS underground in 04" PROVIDE SUPPLY AND DIFFUSERS mss," 9 AS INDICATED ON THE DRAWINGS. '` •�� '`` ' pipe chase to C/U, insulated with 2" PVC drain line with P trap t underground to soil area. armaflex 3/4"x1/2". PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION ' WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL aluminum stand: 23"W-22"H-23"L DRAWINGS. Product Control A royal. Dade County P pp INSTALLATION INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE DRYER EXHAUST WALL CAP DETAIL n.t.s.. MANUFACTURER'S MANUAL AND RECOMMENDATIONS, PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES CONSULTANT' FOR INSTALLATION, OPERATION AND SERVICE. EXTERIOR WALL BATH EXHAUST ROOF CAP DETAIL n.t.s. 1"EMBEDMENT 114"-EXPANSION BOLTS (TYP) (4)REQUIRED - CONDENSING UNIT INSTALLATION n.t.s. � exhaust cap _ -- EXHAUST FAN SCHEDULE: � �METAL WALL CAP P iA MOD: APOLLO EB80 bird screen ® ® flashing — — RPM: 1080 : ® ® 6 roof the 4"METAL DUCT 4(3/8x1-1/2") ® .e AMPS. 0.35 DRYERGE,FROM CLOTHES anchor bolts H.P. 1/20 2"X4" BACKDRAFT SHALL NOT D BE SCREENED Ps PAGE #: ® — CFM: 75 blk'g DAMPER M-1 06" sheet metal duct ,, 120 V AC gauge 26 from exh. fan. concrete slab 4" . {(yy