00-1397-020 ' TYPE MAIN BUS: A ZUBILLAGA DESIGN Inc.
SERVICE : 240V - 10 - 3W NEUTRAL: FULL 3181 CORAL WAY, SUITE 403
MOUNTING FLUSH PANEL ' A MIAMI, FLORIDA . 33145
MAINS: M.L.O.
POLES TEL 305-443-8180
EXIST'G. 2» DEM TRIP CON CKT C A.I.C: 10 K
CON TRIP DEM
WOOD DECK FAMILY ROOM K.V.A. POLE DUIT WIRE REMARKS No No REMARKS WIRE DUIT POLE K.V.A.
6.� 33 ' 2 10 �l� f�(IS( 1 2 G 2 In 1l7 -,o �5,5
3 4
ARCHITECTURE
60 �� (p ,WU, 5 6 14,0,2 ,5 CERTIFICATION No. AA0003002
7 1 8
2a
U/p .1Not MTel p ISG, 1 2 4 ,W. 4. 9 10 t�.N(ti E ca 3x &0
bFl
2'J arc I L 11 1 12
111111111 oil FF P1� ' i=1 f► 6�� �� 2.� � t 13 1 14
15 16 IA
2fl 2 IZ VJA t � 17 18 6H&LIL
I I ,1I�1 19 20
I I
\ � 8 Iz��, 211 1 22 131( TL146 &r- 1,h 1 ,0 I j
P\DI�� I I 1.0 I �� Llt?t�ZS I� G-�f� 23 24 I fl� ►�
I K HEN f D"ft4f:t? � 1 �y
BATH 25 2 6 l-I G l 1"�S I�
DINING ROOM BEDROOM 27 28 LL_
pews -
� 291 1 30
311 32
pA t�
33 34 b6
�✓ P►��� 35 36
�Z� o
37 38 V)
7"
„ �2� towels 6„ 6„ 39 40 -�-+"
LF
�,
4 4 PX_ 41 42 N
Tru
ex. � �
v
LA rNDRY ROOM 100 - 10,D k\/A aEE
. �X 15T1 t•I G ��EG. L-A`(ovT To Fah-li�.l V�
WQ wh I I�Ptd'- G'- ca%a I J9 1 2 t�C V r4 00
,
BBL UNti � o-c��1< ?► �1�� D, _
60 Ps 191\1 7�zFM C) 2� `r����- 37,0. v<��r V
• WA I 1r A��o A � P��JJ
�I C I t
,
i
y j
L.
d\�l BEDROOM ® 220 V. Spacial purpose receptacle `
G LIVING ROOM '` o
LO
R2 f A - 110 V. Duplex receptacle t. p •v
k' cx e ; ati PLAY R ELECTRICALS '
0 M f� 110 V. Over the counter duplex recep. NOTES:
Q Wp 110 V. Duplex water proof receptacle
00
R ` z&GFl 110 V. Ground fault receptacle
�•� I I DLL. ; ® Motor 1. All work shall conform, with the south FLORIDA building code and with the National .. VJ
new a/c- . ��2 �- �----- O Electrical code 1994 edition.
I ----- Smoke detector W D
6�} Switch 2. All work shall be done y'
workmen skilled in the Electrical trade. A foreman shall I
bq-3W Three way switch Y Y C
R�1
W.1. - be on the job at all times when work is being done.
_ D Dimmer switch 1 g f
�d I
�l STO GE '
❑ Electric mater . 3. All receptables shall be' of at Ileast 15 Amps, all others as
p per the panel
J - BATH I!� Electrical panel schedule. Install receptables 18 IN. Above finish floor
4' �-- -� 1 "_ %o/ Exhaust fan DATE: 10-25-00
W IN 4. There shall be ground :fault interruptors (G.F.I.) in receptables at Bathrooms, at
� � y. -/- — Ceiling mounted light fixture the exterior of building, and at those receptables at or closer than 6 feet from REVISIONS: t-
❑, Disconnect switch any water source.
FRONT PORCH \ Incond. recessed vapor proof flxt.
v A 1 ® 5. All Electrical panels shall be accessible and shall have clearance of at least 36 IN.
A260 Provide circuit breaker directories for all ponelboards.
Ceiling fan w/ light
6. Install toggle switches 48 in. Above finish floor.
5"_ Q Telephone outlet 7. Raceways inside building shall be emt, min 3/4" in size. Raceways exposed
TX outlet attached building shall be rigid to the galvanized conduit threaded 3/4' min. SCALE: NOTED .
BEDROOM O HI - hat light fixture size. Raceways underground shall be P.V.C. schedule 40, encase in 3" concrete
envelope.
Wall mounted light fixture BY' O.D.
8. Conduit fittings shall be stell threaded type for rigid conduit and stell compression
.0 Low voltage hl—hat fixture
type for emt. ZUBILLAGA
JUAN J.
y n Q- Door sell RAG: 'ARCHITECT
ELECTRICAL PLAN 1/4"=1'-VI' 9. Notching and boring of wood members shall be limite to the provision of chapter
24" x 48" Flourescent fixture 29 of the south Florida building code. ,�� AR .14147;;0I t
10. Electrical drawings are essentially diagramatic.
��'� � 2t�-l�jJ� ��1 1`7�•T�r�1G\`/Cc�4�:�/' (��--�Vl�aT�T'' C�� V�ll�-�� �c7 ,�, {`
p�\� Y""1C'S�"�-~\•I 1'.]l.�` G✓�l'•'"�'V� 1 i , � ;�ri) ^ f�c�l�,, 'i' Itr,Y'+�� C ,�,q,�
11. Seal all walls, floors, ceiling and roof penetrations back to original fire rating using 4
approved ul compound materials.
FROtA F.PL.LINF5
12. All electrical control items mounted outside shall be weatherproof. ►'"
�. .
MAIN DISCONNECT
2 POLES yCJta AMPS.
120/240 VOLTS 13. Any lighting directly over humidity produced by any equipment or appliance shall '� •`
be vapor proof.
USE 3 #3wTHHN J �
IN 2" CONDUIT MIN. PANEL 14. Electrical outlett (receptacles and lighting) below base flood Elevation shall be
3 #I/OTHHN CU "A°
IN 2' CONDUIT a2 CKTS. installed at the highest: permited elevation and shall be installed on (separate)
2Qo AMPS. 120/240 V independent circuits from those in the habital area.
CONSULTANT:
15. No appliances or appliance outlets shall be intalled bellow base flood elevation.
METER
O16. A/C compressors shall be installed above base flood elevation.
17. Main circuit breaker panels shall be located above base flood elevation.
18. It is suggested that contractor confer with FLORIDA POWER & LIGHT ,co. to
C TUC GNIN locate the electrical meter to comply with federal emergency mana ement ago
n,c
' CONDUCTOR IN p y g y
IN A 3/4" P.V.C. requirements
CONDUIT
' 3/4" W.P. 19. Contractor shall prewire all telephone outlets with 4/c #24 telephone cable run
in partition and dropped ceilings from incoming telephone junction box.
(MIN.)
2 GALVANIZED 20. Contractor shall prewire all television outlets. with RG59U coaxial cable run in
GROUND RODS partitions and dropped ceilings from incoming cable TV unction box.
• 5/8 x 10 FT. 9 9 j
21. Romex is an alternate wiring method if approved by owner PAGE #:
ELECTRICAL RISER n.t.s. _ E-1