00-1397-010 ZD HVAC DESIGN REQUIRES: YES NO AIR CONDITIONING ZUBILLAGA DESIGN Inc. GENERALNOTES 3191 CORAL WAY, SUITE 403 Duct Smoke Detector X MI TEL 305-44336160 Fire Damper(s) Smoke Damper(s) X 1. ALL EXHAUST DUCT SHALL BE CONSTRUCTED OF SHEET 2„ Fire Rated Enclosure X METAL, TERMINATE OUTSIDE THE BUILDING, AND BE FAMILY ROOM Fire Rated RZCeiling Assembly X EQUIPPED WITH A BACK DRAFT DAMPER. ARCHITECTURE Fire Stopping X (NO T—FIN ALLOWED) CERTIRCAMON No. M0003002 Smoke Control X 2. DUCTS FROM TOILET ROOMS SHALL DISCHARGE TO THE OUTSIDE OF THE BUILDING, SHALL BE TERMINATED NOT LESS THAN 6 INCHES ABOVE THE FINISH FLOOR SURFACE, AND SHALL BE SCREENED WITH A CORROSION RESISTANT MATERIAL HAVING A MESH SIZE NOT LARGER THAN 1/2 INCH. (PROVIDE GOOSE NECK OR RAIN CAP ON ROOF TERMINATIONS) 3. CLOTHES DRYER EXHAUST DUCT SHALL NOT BE SCREENED. 4. CLOTHES DRYERS EXHAUST DUCT (OR VENTS) SHALL A/C EQUIPMENT SCHEDULE COMPLY WITH MANUFACTURERS INSTALLATION INSTRUCTIONS, BE CONSTRUCTED OF A MINIMUM 26 GAUGE METAL PIPE, UNIT NUMBER A/H HAVING A SMOOTH INTERIOR SURFACE WITH JOINTS AREA SERVED SEE PLAN RUNNING IN THE DIRECTION OF THE AIR FLOW. DUCTS JOINTS SHALL NOT BE ASSEMBLED WITH SHEET METAL SCREWS OR OTHER FASTENERS WHICH WOULD LL_ KITCHEN TOTAL AIR SUPPLY 1000 EXTEND INTO THE DUCT. DINING ROOM BATH BEDROOM OUTSIDE AIR CFM 0 GENERAL �P �E PA PROVIDE FURNISH AND INSTALL ALL NECESSARY 160CFM 160CFM EXTERNAL STATIC PRESSURE -IN W.G.- 2 ( ) g MATERIALS AND LABOR FOR A COMPLETELY OPERATIONAL 10X6 10X6 1/3 AIR CONDITIONING, HEATING AND VENTILATING SYSTEM AS cn FAN MOTOR HP/FL.A 4.4 SHOWN ON THE DRAWINGS AND HEREIN SPECIFIED ELEC. CHARACTERISTICS V/ Hz/0 208/230-60-1711 INSTALL IN ACCORDANCE WITH THE SOUTH FLORIDA BUILDING CODE, ASHRAE, SMACNA, NFPA, AND LOCAL j J 29600 ORDINANCES. W p COOL. COIL CAP. -BTU/HR- ♦, 75CFM exhaust fan with back towels U SCOPE OF WORK : •� cn 06"flex __ 06"flex draft damper. Provide a 06° z TOTAL SENSIBLE HEAT - BTU/HR- 21200 PROVIDE THE FOLLOWING COMPLETE SYSTEMS o -C i --12.4,x 24 sheet metal duct gauge 26 to ex. J ENT. AIR TEMP. -F DB/ F WB-° d' I I�� , �e�v�N BATH O A. SUPPLY DUCT SYSTEM. 00 LAUNDRY ROOM I , g roof cap. SEE DETAIL. a.h.u. O U MODEL NUMBER RCHA36A1 136 flex B. EXHAUST SYSTEM FOR BATHROOMS o �H ® UNIT MANUFACTURER RHEEM C. AIR CONDITIONING UNITS WITH REFRIGERANT PIPING ; In AND CONTROLS. � / Q18"flex Sx6x6" duct board MODEL NUMBER RBHA-17J07 PAY FOR ALL FEES, INSPECTIONS AND CONNECTION J 40CFM r CHARGES REQUIRED. o LO / 06"flex 220CFM Q WEIGHT -lbs.- 92 / 10X8" 04"flex 8X4 MCA/MFS COOLING VERIFY AT JOB SITE ALL SPACE CONDITIONS, DIMENSIONS / 87CFM MCA/MFS HEATING AND EQUIPMENT SIZES PRIOR TO DUCT FABRICATION OR a refrigerant and drain lines. / 10X6 BEDROOM INSTALLATION. COORDINATE REQUIREMENTS TO AVOID SEEA/H INST. DETAIL. / 06"flex LIVING ROOM UNIT NUMBER C/U INTERFERENCE WITH OTHER TRADES. Z LOCATION ON SLAB GUARANTEE ALL WORK FREE OF DEFECTS IN MATERIALS AND WORKMANSHIP FOR A PERIOD OF ONE YEAR FROM CD AMBIENT TEMP. °F 92 DATE OF ACCEPTANCE. w Z MATERIALS = anchored to z REFRIGERANT a ALL DUCTWORK TO BE R-6. concrete slab. 1-08"flex 04"flex z COMPR./COND. FAN FLA ALL DUCT SIZES SHOWN ARE CLEAR INSIDE DIMENSIONS. EE DETAIL. 87CFM 2 CFM PROVIDE HANGERS, FOR FLEXIBLE DUCTS OF SHEET METAL S 20 STORAGE 10X6" 10X8" O ELEC. CHARACTERISTICS V/Hz/0 208/230-60-01 26 GAUGE, 1-1/2" WIDE AT 5 MAX. SPACING BETWEEN DATE: 10-25-00 wall type dryer exhaust. 26CFM p SUPPORTS. SEE DETAIL. PLAY ROOM 8X4" BATH J UNIT MANUFACTURER RHEEM PROVIDE HANGERS FOR FIBROUS GLASS DUCTS OF SHEET METAL GAUGE 26 OR ANGLE IRON, ADEQUATELY SPACED. REVISIONS: WIN O MODEL NUMBER RALB-030JAZ PROVIDE DOUBLE THICKNESS TURNING VANES AT ALL d W.I.C. WEIGHT -Ibs.- 169 SQUARE ELBOWS. WHERE THE ELBOWS ARE RECTANGULAR D 03-29-01 Q INSTALL SINGLE THICKNESS INSTEAD. FRONT PORCH REMARKS PROVIDE VOLUME EXTRACTORS BEHIND EACH SUPPLY OUTLET AND AT EACH DUCT BRANCH. SYSTEM (S)EER 11.4 REFRIGERANT PIPING. SEAMLESS COPPER TYPE "L" AND II t_ tt LIQUID/SUCTION SIZE-IN 3/8" X 3/4" HARD OR SOFT DRAWN ON ACR COPPER TUBING WITH 1 _ — MLCHANICAL PLAN )4 —1 O WROUGHT COPPER SOLDER. = ELECTRIC HEATER -KW- 7 INSULATE ALL REFRIGERANT SUCTION PIPING WITH 1/2" SCALE: NOTED CLOSED CELL POLYETHYLENE PRE MOLDED PIPE INSULATION, WITH AN APPROVED PIPE AND SMOKE BEDROOM JACKET. PAINT ALL EXPOSED INSULATION WITH TWO BY: O.D. COATS OF WHITE LATEX PAINT. PROVIDE AIR CONDITIONING UNITS WITH MATCHING LOW JUAN J. ZUBILLAGA' VOLTAGE HEAT—COOL THERMOSTATS WITH ON—OFF AUTO AIR HANDLER INSTALLATION n.t.s. SUB—BASE SWITCH, FURNISHED BY THE EQUIPMENT REG. ARCHITECT\ MANUFACTURER. AR 14147 ALL AIR CONDITIONING COMPRESSORS SHALL BE 03/8" OD liquid line 16"X10" R-6 ductwork WARRANTED FOR A MINIMUM OF FIVE YEARS AFTER DATE 3' up to main trunk OF ACCEPTANCE OF THE PROJECT. 03/4 OD suction line AIR DISTRIBUTION PRODUCTS underground in 04" pipe chase to C/U, PROVIDE SUPPLY AND DIFFUSERS ` insulated with 2" PVC drain line with P trap AS INDICATED ON THE DRAWINGS. armaflex 314"x1/2". L underground to soil area • , r �> PROVIDE FINISHES AND TYPES OF MOUNT IN COORDINATION aluminum stand: 23"W-22"H-23"L WITH THE CEILING TYPES AS SHOWN ON ARCHITECTURAL Dade County Product Control Approval. DRAWINGS. ..1.•. '''`'�''' `� INSTALLATION INSTALL ALL EQUIPMENT IN ACCORDANCE TO THE CONSULTANT: DRYER EXHAUST WALL CAP DETAIL n.t.s. MANUFACTURERS MANUAL AND RECOMMENDATIONS, PAYING SPECIAL ATTENTION TO REQUIRED CLEARANCES FOR INSTALLATION, OPERATION AND SERVICE. EXTERIOR WALL BATH EXHAUST ROOF CAP DETAIL n.t.s. 1"EMBEDMENT CONDENSING UNIT INSTALLATION n.t.s. •� (44"-EXPANSION BOLTS (TYP) f(4)REQUIRED EXHAUST FAN SCHEDULE: 'ic exhaust cap co METAL WALL CAP ° o MOD: APOLLO EB80 bird screen o ° flashing. o ° RPM: 1080 = _ 6' g 4(3/8x1-1/2") o o roof file 4"METAL DUCT AMPS. 0.35 anchor bolts ° ° J= - - - - -- = GE,FROM � H.P. 1/20 DRYER 4" CLOTHES DRYER WALL CAPS PAGE 2"X BACKDRAFT SHALL NOT BE SCREENED v CFM: 75 blk'g DAMPER 1 120 V AC concrete slab 4" y gauge 26 from exhcfan. 6-6