00-1226-016 - - v N c
PLUMBING NOTES: .cc
I. ALL WORK TO BE IN ACCORDANCE WITH THE LOCAL PLUMBING CODES.
LUM�I NCB
fi� FIXTURE SGHDUL
2. BUILDING DRAINAGE SYSTEM BASED ON 1/8" / FT. MINIMUM FALL. ANY DEVIATIONS
" SHALL BE APPROVED BY ARCHITECT AND ENGINEER. SYMBOL FIXTURE TYPE TRAP C. P. H. P. DESCRIPTION
SIZE FACE OF WALL.
5. CONTRACTOR TO PROVIDE I" (MIN) WATER PIPE GAPPED AT EVERY ELECTRICAL P-1 WATER GLO5ET 4" 1/2" - STAINLESS STEEL COVER 5GREWED .
SWITGHGEAR ROOM OR METER ROOM TO BE USED AS GROUND. TO THREADED G.O. PLUG.
4. ALL VALVES UNDERGROUND TO BE INSTALLED IN PRECAST CONCRETE BOXES, BROOKS, P-2 LAVATORY 1-1/211 ti
OR EQUAL. I/2" I/2" w/ ANTI-SCALD VALVES
P-3 BATH TUB 2" ..� N
5. PLUMBING CONTRACTOR TO FURNISH ALL REQUIRED FLASHING FOR PIPES TO ROOFING Ln m
"ZURN" #Z-1446-BP-VP FOR EXPOSED v O cfl
CONTRACTOR. P-4 WHIRLPOOL 2" 1/2" 1/2" w/ ANTI-5GALD VALVES BLOCK AND GYPSUM BOARD WALLS.
6. MATERIALS SHALL BE ALL NEW AND AS FOLLOW5: I I "ZURN" #ZN-1447-BP-VP FPR TILE �: C=
A) DRAINAGE PIPING - NO HUB CAST IRON STD. 301 OR PVG-DWV 5GH. 40 P-5 SHOWER 2" 1/2" 1/2" w/ ANTI-5GALD VALVES WALLS. "ZURN" #ZN-1448-BP-VP L C6
B) WATER PIPING - TYPE L COPPER (UNDERGROUND). TYPE M COPPER (ABOVE FOR PLASTER WALLS.
O _
GROUND). PIPES GOATED WITH ASPHALT. w
P-6 BIDET 2" 1/2" 1/2" w/ VACUUM BREAKER WALL
G) A/G CONDENSATE DRAIN - SCHEDULE 40 PVC. cc
D) PLUMBING FIXTURES - AMERICAN STANDARD, KOHLER, CRANE, OR EQUAL.
E) FLOOR AND ROOF DRAINS IF USED, J05AN OR EQUAL. P-7 BAR SINK 1-1/2" 1/2" 1/2"
F) ELEGTRIG WATER HEATERS - GLASS LINED - 5 YEAR GUARANTEE - MORFLO OR
EQUAL' P-8 KITCHEN SINK 1-1/2" 1/2" 1/2" w/ GARBAGE DISPOSAL
G) VALVES - 125 P51 - NIBGO, SCOTT, OR EQUAL.
H) HOSE BIBS - CHICAGO G52 OR EQUAL. "ZURN"
P-9 DISHWASHER - I/2" D150HARGE INTO GARBAGE #ZN-1400-BP-T-VP GONGRETE PAD "ZURN" #Z-1404-VPIRON BOX W/
7. PROVIDE ALL EXCAVATION, BACK FILL AND COMPACTION REQUIRED BY ALL PLUMBING DISPOSAL UNIT. FLOOR GLEANOUT. 2'x2'x8" W/ 4# COYER MARKED "G.O."
�� 3EW.
WORK.
P-10 SINK 2" 1/2 - FIN. FLR. FIN. GRADE
8. PERFORM THE FOLLOWING TE5T5:
A) WATER PIPING SHALL BE SUBJECTED TO HYDROSTATIG PRESSURE TEST OF 100 P-11 LAUNDRY SINK 1/2" 1/2"
P516 FOR A PERIOD OF TIME SUFFICIENT TO EXAMINE ENTIRE SYSTEM BUT NOT LESS THAN
ONE HOUR. P-12 WASHING MAGHI. 2" 1/2" 1/2"
B) DRAINAGE PIPING - BEFORE INSTALLATION OF ANY DRAINS, THE ENDS OF SYSTEM FILL VOIDS W/ OILED SAND. Q
SHALL BE GAPPED AND ALL LINES FILLED WITH WATER TO HIGHEST POINT AND ALLOWED TO P-13 REFRIGERATOR - - PROVIDE VALVE CONTROL SECTION VIEW COMPACTED FILL L J 0
STAND UNTIL INSPECTION IS MADE AND WATER LEVEL REMAINS CONSTANT. FOR GLAR1111 —�
G) CORRECT ALL DEFECTS DISGL05ED BY ABOVE TESTS.
ELEVATION VIEW GLEANOUT FITTING W/ BRA55 PLUG. Q w
q. STERILIZE ALL WATER LINES WITH A MIXTURE OF (2) TWO POUNDS OF CHLORINATED NOTE: ALL DRRAIN PIPING UNDER SLAB SHALL BE 2" MIN �- �/ 0
LIME TO EACH 1000 GALLONS OF WATER (50 PPM OF AVAILABLE CHLORINE). RETAIN 2" 4 LESS DIA DRAIN ® 1/4" DROP / \ / \ w Q [-- -i
MIXTURE IN PIPES 2 114 HORS AND FLUSH THOROUGHLY WITH POTABLE WATER BEFORE 3" $ 4" DIA DRAIN ® 1/8" DROP I-
PLAGING IN 5ERVIGE. z CN
10. COMPLETE SYSTEM, FIXTURES AND EQUIPMENT SHALL BE G 1 VEN AN IN-5ERVIGE TEST W w
AFTER COMPLETION OF THE INSTALLATION. (n (D
LOOK TO GRADE {
11. PLUMBING CONTRACTOR SHALL FURNISH A WRITTEN GUARANTEE THAT ALL PLUMBING TWO-WAY GLEANOUT TEE OR 0 Q p
WORK SHALL BE FREE FROM DEFECTS OF MATERIALS AND WORKMANSHIP FOR A PERIOD OF LONG SWEEP QUARTER BEND. _
ONE YEAR FROM DATE OF FINAL ACCEPTANCE, AND THAT THEY WILL, AT THEIR EXPENSE 0 N l
REPAIR AND REPLACE ALL WORK WHIGH BEGOME5 DEFECTIVE DURING GUARANTEE PERIOD. NOTE: REFER TO SPECIFICATIONS FOR MATERIALS N
AND REQUIREMENTS FOR INSTALLATION.
Lo 0
(f) .
CLEAN OU T DETAILS N.T.S. `~
y
4.4..r7
r �1
i
w
wo
TMas dna ng ntl lM1n—g—M1nrc
Illuavvtvtl vm We solo POpody or
Nfrodo Julian vntl mvy nat be
oPmtlucvd In wlwle or In part wlgwul
na Purtnieabn
JO B NUM B ER
00038
EXIST. OFFICE AREA EXIST. RETAIL SPACE
R E V I S 1 0 N S
Al BLD.DERREV. 10/19/00
CONNECTED EXISTING
' SANITARY LINE TO
NE 4" SANITARY LINE
VER EXISTING
LOG TION ff SIZE
NEW BATH 4"
5FU
P-1 F 1 L E
WG 3.. 2.. P-2
LAY. P L O T : 100%
DRAWN : M.C.
EXISTING I" WATER
CHECKED : A.J.
LINE VERIFY EXI5TI G 3„VTR 2„VTR
LOCATION � SIZE
D A T E 10/12/00
SHEETINDEX
Gtl�
PLUMBING
PLAN ; t. �
PLUMBING PLAN SHEET NUMBER't,, ,r
l ,
SCALE: 1 4” = 1'-0” � C31 .
OF. ""