Loading...
00-0366-014 T1 : =71— - r , - - - r.r. T-- i a O ELECTRICAL LOAD CALCULATION 3 Z z ELECTRICAL NOTES LEGEND $ o �ECT. TYPE = SQUARE `D' MODEL'Q0142L225Cs MAIN BUS: 200 AMPS „ I I A - GENERAL LIGHTING LOAD SERVICE NEUTRAL : 200 AMPS pp p Wall Switch 15 A, 125 V _ VOLTAGE 240/120 v 1 0 -/3 w. PANEL—D MAINS 200 AMPS _ WATTS T5 2 3'(0 5F• 3W/SF r,u0 MOUNTING- 3Ut�ACE LOCATION S+•aowN Iz 1. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND Duplex Receptacle 15 ,4125 V B - TWO SMALL APPLIANCE CIRCUITS X 1,500 = 1,500 WATTS o a EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ® 220 v. Receptacle TOT COND CKT. CKT. COND TOT C - FIXED APPLIANCES: COOK TOP 12,000 AMPS POLE V.A. SIZE+ WIRE REMARKS NO. NO. REMARKS SIRE SIZE+V.A. OLE AMPS ACCORDANCE WITH THESE DRAWINGS, @M Monitor REFRIGERATOR 850 60 2 00 iii' 6 A.HU.-I 1 2 G.U.-I im 'is' 4200 1 2 30 a 2. COMPLY WITH THE NEC. AND THE SOUTH FLORIDA BUILDING CODE o Incandescent Lighting Fixture WATER HEATER 6000 ' 3 4 3. PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM, l-0 Wall Bracket Light 30 2 5�m0 ,,` im A.HU.-z 5 a ELECT. WATER HEATE '�z' 60 2 3m R°II III Z 'I CONNECTED LOAD LESS A/C = 21460 WATTS 7 g 4. OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT, Recessed N(-Nat 10000 W 1000 = 10,000 WATTS �� , S' � ) 1 20 1 I ' REST W 0 40io = 6,984 20 1 850 z 12 REFRIGERATOR 9 10 CFI, BATH REGEPTS• 12 �/ 5. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY Floodli ht 20 1 1500 i2' n SMALL APPL. 11 lz EMERGENCY LIGHTS 12 1/ , 400 1 20 y g � A/C (or heating) g 1000 19D0m WATTS � 'I � OTHER TRADES. Junction BOx Duple Counter Receptacle i KItCHEN/ BATH LIGHT. 13 14 MICROWAVE _ DEMAND LOAD = 31,984 /240 WATTS 133 AMPS �+ 240/120 Y 20 1 C ) �_' 12 12 iiz1 1200 1 2m p o (o. NO APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEV. SERVICE 812E = 2mm AMPS, 20 1 418 ii' 12 GEN. LIGHTING 15 18 GEN LIGHTING 12 1/2' 418 1 20 Q PH Phone Outlet Motion 17 18 ¢ m r 7• COORDINATE ALL OUTLET LOCATIONS WITH ARCHITECTURAL FEATURES. FAx Fax outlet Detector D - NEUTRAL LOAD 19 20 q Q o a 14 S. CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF Electrical Panel LIGHTING AND SMALL APPLIANCE 8ro1(d WATTS 21 22 WITH ALL EXISTING CONDITIONS. FIRST 3,000 W1 1000°-= 39600 WATTS 23 24 0 1� Electrical Meter WATTS 25 26 . 9. A/C COMPRESSOR AND ALL ELECTRICAL CONNECTIONS SHALL BE RANGE x �0�0 = 8- WATTS o INSTALLED ABOVE BASE FLOOD ELEV. L❑ Disconnectin Switch , 27 28 SPOT LIGHTS 12 C•) 1 z0 w 10. OUTDOOR CONDUITS SHALL BE SCHEDULE 40 PVC. s� Smoke Detector KEYPAD TOTAL NEUTRAL WATTS = 13364 WATTS = 5568 AMPS ze 30 C.U.-2 Im 4200 2 3m 0 31 32 J 01 M m MINIMUM COYER SHALL BE 24°. ExhauBt Fan 33 34 EXT, RECEPTS. 12 ,z- C•) 1 20 o 11. ALL MOUNTING HARDWARE SHALL BE BY ELECTRICAL CONTRACTOR . �s Speaker 20 1 C.) t,2. >a MONITOR 35 36 MONITOR 12 12 �•) 1 20 W A INSTALLED AT THE 20 1 C•) i�z� 12 ALAW PANEL 37 38 SPACE 12. ELECTRICAL OUTLETS BELOW BASE ELEV.. S LL BE LL Self-Contained Wall Mounted HIGHEST POSSIBLE ELEY AND SHALL BE INSTALLED (SEPARATE) AS Battery Powered Emergency SPACE 39 40 j a INDEPENDENT CIRCUITS FROM THOSE iN THE HABITABLE AREAS, 9 200 AMP I 41 42 o ELECTRICAL METER DISC, BIRK , z = C4 - T A O AS FLOOD ELEV. I h : 31984 w 133 AMPS ) "3/0 1N 2 GOND. I 13. MAIN CIRCUIT BRAKE PANELS SHALL BE LOCATED B YE BASE L � Wall Mounted Exit L g t 200 AMP. MGB DEMAND LOAD FEEDER 4 IT I UI THAT ELECT. CONTRACTOR CONFERS WITH F.P.L. TO LOCATE THE ELECT. ELECT PANEL 1 S REQ RED W i Intercom (SEE LOAD CALCULATION) FED FROM • FPL SERVICE II I Z ' / `• 1 Z METER TO COMPLY W/ FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ❑ 2'x 4 Flourescent I 15, DISTANCE BETWEEN RECESSED BOXES IN FIRE RATED WALLS OR CEILINGS Light Fixture w Master intercom 1 - MANUFACTURERS SPECIFICATIONS SHALL COMPLY WITH 10 3B NEC, I AND U.L. REQUIREMENTS. - -- I&. RECEPTACLES AND SWITCHES SHALL BE STANDARD TYPE, COLOR TO BE —C4) "3/o IN a' COND, 2' COND. TO 10,000 AIC a SELECTED BY OWNER POWER COMP I I N 1'1, ALL BATHROOMS, EXTERIOR AND GARAGE OUTLETS SHALL BE GFI, ~ I ALL KITCHEN COUNTER RECEPTACLES SHALL BE GF.I. I "6 G. IN 1/ ' G TO C.W. • AN o FOUNDATION STEEL P D I 16. 41C, � o EQUIPMENT SHALL BE FUSED AS PER MANUFACTURERS I � SPECIFICATIONS. 19, ELECTRICAL PANEL AND BREAKERS SHALL BE RATED a 75°. J I L ' N C LLEC RLS ER NB. Z z U i CONCRETE-ENCA5ED ELECTRODE, An Electrode encased by at least 2' ° and near the bottom of a concrete N of concrete, located within a foundation or footing that is in direct contact w/ the earth, g consisting of at least 20'of one or more steel reinforcing bars or rods of not less than 1/2' diameter or consisting of at least 20' 11 of bare copper conductor not smaller than 6 AWCs. ZI o I I ---- - z ER -___ _s� ____ - -==== --__ -==i�� II I UP cu.-2 SU.-1 = 28 \ 31 31 3CsF 1.30/321 2/4 � II ELECTRICAL d' EL I -------- ---�- METER <` ------ 28 \`. IS �\ \�`\ \\�\ `. , • III ... - - -3 3w - ALARM c ELECTRICAL 31 W.H. �, STOR. 16 DISCONNECT. 29 UP KEYPAD o 31 6/8 _ OFFICE #1 OFFICE #3 / o _ ALARM 24 16 � 13o l3 I� / Z PANEL - , 18 V l8 �l 0 z 1 A 1 ,' 31 3 i BATH I '' _ - I Ii , I o 4 V P I I I I , . / G DN. 5 WITCH IN i FAX I o f,^ I � I l I U II I G _ FRONT ENTRACE 29 i Mai .z 3w 3 � I _ I I 3 I II 31 S M I � � (SITTING AREA) II 2� 3� 35 16 29 I I I 6 l I� T EEC . 111 L 31 I I I SPOT L IGHTS Z GF I - 15 P I I�I�II 'GF PNL I I1 _ ^ � 12 � O ' . _ � 1. I 23 Imo • _ 13 2m 6'-0' HEIGHT AFF 29 26 Motion 23 / ^W�i SITTING �' _ _.-. - pA o r-- - 14 CFI; - - 20U FOR ALA PANEL ((� _ _ Detector RE L ---- - III Mot n 3 I� 34 tt27 ---� 1 23 ----- 3w 15 o 16 3w SITTING De ctor � GF l i WP. aw 21 1 AREA i ^ _ � I 1 RE IJ I GF. OFFICE 4 , 2m OF CE 9 IS 33 Ig 34 O Bl11LT-IN , I GF I. al DISCONNECT. 1� O FAX _ AHU O I C i - 20 26 �. � 23 1/ 23 PH 19 UP v 1 U- 21 1 i z , I P I ,- 20 kI 8 1 2 i CFI. HU, n --- -- - 18 � / \ SITTING *2� ' 11 PORCH < 'I ;XITCNEN - A 2 I 2 I FRONT I� Iz I RON _ 1 li - 8 s DESK � SITTING / 22 --- , 18 2� �, � �' Detector BUILT-IN AREA Motion DISCONNECT. ---- OFFICE #2 I �\ � a 23 II I 9 I --- I � . - - , - � CFI• � =20 � � ' FAx� �_ I 24 ` � I � I - • ----- y O ' — PH 24 10 �, 24 ! s` T 21 I I � ; PORCH I �' , I T4� PH i8 ; ! MCI 22 O 22 —� 3� 18 21 25 23 P t , - 24 CONFERENCE 13� I' 1 - 34 3w rn ?� I fl I 23 1 , R M 23 I FAX I 4 24 f� 25 IM OFFICE "S Motion 12 17 -' _; o a C PH 33 33 25 C= 22 Detector o , , r . O I I J I J ? ---- —ANOE, t-------- U --- ---- 1----- ------------- ---------- j - _ _ - / `'-f' '••.. 28 sc 28 Ramp I ` W s I _ �J I IN SWITCH _ _ _ FRONT ENTRANCE o W ----- - ---- - - - - - --- X (SITTING AREA) X p� r m I w w li = � L CTR'f GAL FLOOR PLAN ELECTRICAL FLOOR FLAN w zi SECOND FLOOR PLAN SCALE: 1/4'= I'-01 FIRST FLOOR PLAN SCALE: 1/41° 1'-0' T 77T777 I