00-0366-014 T1 : =71— -
r , - - -
r.r.
T--
i
a O
ELECTRICAL LOAD CALCULATION 3 Z
z
ELECTRICAL NOTES LEGEND $ o
�ECT. TYPE = SQUARE `D' MODEL'Q0142L225Cs MAIN BUS: 200 AMPS „ I I
A - GENERAL LIGHTING LOAD SERVICE NEUTRAL : 200 AMPS pp p
Wall Switch 15 A, 125 V _ VOLTAGE 240/120 v 1 0 -/3 w. PANEL—D MAINS 200 AMPS
_ WATTS
T5
2 3'(0 5F• 3W/SF r,u0 MOUNTING- 3Ut�ACE LOCATION S+•aowN
Iz
1. CONTRACTOR SHALL FURNISH ALL LABOR MATERIALS AND Duplex Receptacle 15 ,4125 V B - TWO SMALL APPLIANCE CIRCUITS X 1,500 = 1,500 WATTS o a
EQUIPMENT FOR COMPLETE ELECTRICAL INSTALLATION IN ® 220 v. Receptacle TOT COND CKT. CKT. COND TOT
C - FIXED APPLIANCES: COOK TOP 12,000 AMPS POLE V.A. SIZE+ WIRE REMARKS NO. NO. REMARKS SIRE SIZE+V.A. OLE AMPS
ACCORDANCE WITH THESE DRAWINGS, @M Monitor REFRIGERATOR 850 60 2 00 iii' 6 A.HU.-I 1 2 G.U.-I im 'is' 4200 1 2 30 a
2. COMPLY WITH THE NEC. AND THE SOUTH FLORIDA BUILDING CODE o Incandescent Lighting Fixture WATER HEATER 6000 '
3 4
3. PROVIDE EMPTY CONDUITS AS REQUIRED FOR TELEPHONE SYSTEM, l-0 Wall Bracket Light 30 2 5�m0 ,,` im A.HU.-z 5 a ELECT. WATER HEATE '�z' 60 2 3m R°II III Z 'I
CONNECTED LOAD LESS A/C = 21460 WATTS 7 g
4. OBTAIN ALL PERMITS FOR WORK UNDER THIS CONTRACT, Recessed N(-Nat 10000 W 1000 = 10,000 WATTS �� , S' � ) 1 20 1 I '
REST W 0 40io = 6,984
20 1 850 z 12 REFRIGERATOR 9 10 CFI, BATH REGEPTS• 12 �/
5. PROVIDE TEMPORARY POWER AND LIGHT OUTLETS FOR USE BY Floodli ht 20 1 1500 i2' n SMALL APPL. 11 lz EMERGENCY LIGHTS 12 1/ , 400 1 20
y
g � A/C (or heating) g 1000 19D0m WATTS � 'I �
OTHER TRADES. Junction BOx Duple Counter
Receptacle i KItCHEN/ BATH LIGHT. 13 14 MICROWAVE _
DEMAND LOAD = 31,984 /240 WATTS 133 AMPS �+ 240/120 Y 20 1 C ) �_' 12 12 iiz1 1200 1 2m p o
(o. NO APPLIANCE OUTLETS SHALL BE INSTALLED BELOW BASE FLOOD ELEV. SERVICE 812E = 2mm AMPS, 20 1 418 ii' 12 GEN. LIGHTING 15 18 GEN LIGHTING 12 1/2' 418 1 20
Q PH Phone Outlet Motion 17 18 ¢ m r
7• COORDINATE ALL OUTLET LOCATIONS WITH ARCHITECTURAL FEATURES. FAx Fax outlet Detector D - NEUTRAL LOAD 19 20 q Q o a
14 S. CONTRACTOR SHALL VISIT THE SITE TO FAMILIARIZE HIMSELF Electrical Panel LIGHTING AND SMALL APPLIANCE 8ro1(d WATTS 21 22
WITH ALL EXISTING CONDITIONS. FIRST 3,000 W1 1000°-= 39600 WATTS 23 24 0
1� Electrical Meter WATTS 25 26 .
9. A/C COMPRESSOR AND ALL ELECTRICAL CONNECTIONS SHALL BE RANGE x �0�0 = 8- WATTS o
INSTALLED ABOVE BASE FLOOD ELEV. L❑ Disconnectin Switch , 27 28 SPOT LIGHTS 12 C•) 1 z0
w
10. OUTDOOR CONDUITS SHALL BE SCHEDULE 40 PVC. s� Smoke Detector KEYPAD TOTAL NEUTRAL WATTS = 13364 WATTS = 5568 AMPS ze 30 C.U.-2 Im 4200 2 3m
0 31 32 J 01 M m
MINIMUM COYER SHALL BE 24°. ExhauBt Fan 33 34 EXT, RECEPTS. 12 ,z- C•) 1 20 o
11. ALL MOUNTING HARDWARE SHALL BE BY ELECTRICAL CONTRACTOR . �s Speaker 20 1 C.) t,2. >a MONITOR 35 36 MONITOR 12 12 �•) 1 20 W
A INSTALLED AT THE 20 1 C•) i�z� 12 ALAW PANEL 37 38 SPACE
12. ELECTRICAL OUTLETS BELOW BASE ELEV.. S LL BE LL Self-Contained Wall Mounted
HIGHEST POSSIBLE ELEY AND SHALL BE INSTALLED (SEPARATE) AS Battery Powered Emergency SPACE 39 40 j a
INDEPENDENT CIRCUITS FROM THOSE iN THE HABITABLE AREAS, 9 200 AMP I 41 42 o
ELECTRICAL
METER
DISC, BIRK
, z
= C4 -
T A O AS FLOOD ELEV. I h : 31984 w 133 AMPS ) "3/0 1N 2 GOND. I
13. MAIN CIRCUIT BRAKE PANELS SHALL BE LOCATED B YE BASE L � Wall Mounted Exit L g t 200 AMP. MGB DEMAND LOAD FEEDER
4 IT I UI THAT ELECT. CONTRACTOR CONFERS WITH F.P.L. TO LOCATE THE ELECT. ELECT PANEL
1 S REQ RED W
i Intercom (SEE LOAD CALCULATION) FED FROM • FPL SERVICE II I Z
' / `• 1 Z
METER TO COMPLY W/ FEDERAL EMERGENCY MANAGEMENT AGENCY REQUIREMENTS. ❑ 2'x 4 Flourescent I
15, DISTANCE BETWEEN RECESSED BOXES IN FIRE RATED WALLS OR CEILINGS Light Fixture w
Master intercom
1 - MANUFACTURERS SPECIFICATIONS
SHALL COMPLY WITH 10 3B NEC,
I
AND U.L. REQUIREMENTS. - --
I&. RECEPTACLES AND SWITCHES SHALL BE STANDARD TYPE, COLOR TO BE —C4) "3/o IN a' COND,
2' COND. TO 10,000 AIC a
SELECTED BY OWNER
POWER COMP I
I
N
1'1, ALL BATHROOMS, EXTERIOR AND GARAGE OUTLETS SHALL BE GFI,
~ I
ALL KITCHEN COUNTER RECEPTACLES SHALL BE GF.I.
I "6 G. IN 1/ ' G TO C.W. • AN o
FOUNDATION STEEL P D
I 16. 41C, � o
EQUIPMENT SHALL BE FUSED AS PER MANUFACTURERS
I �
SPECIFICATIONS.
19, ELECTRICAL PANEL AND BREAKERS SHALL BE RATED a 75°.
J I
L '
N C
LLEC RLS
ER NB. Z
z
U
i
CONCRETE-ENCA5ED ELECTRODE, An Electrode encased by at least 2' °
and near the bottom of a concrete N
of concrete, located within a
foundation or footing that is in direct contact w/ the earth, g
consisting of at least 20'of one or more steel reinforcing bars
or rods of not less than 1/2' diameter or consisting of at least 20' 11
of bare copper conductor not smaller than 6 AWCs.
ZI
o
I I
---- -
z
ER
-___ _s� ____ - -====
--__ -==i��
II
I
UP cu.-2 SU.-1 =
28 \ 31 31 3CsF 1.30/321 2/4
� II
ELECTRICAL
d'
EL I
-------- ---�- METER <`
------ 28
\`. IS �\ \�`\ \\�\ `. , • III
... - - -3 3w - ALARM
c
ELECTRICAL
31 W.H. �, STOR. 16 DISCONNECT. 29
UP KEYPAD o
31 6/8 _ OFFICE #1 OFFICE #3 / o _
ALARM 24 16 � 13o l3 I� / Z
PANEL
- ,
18 V l8 �l 0
z
1 A
1
,' 31 3 i BATH I '' _ -
I Ii
,
I
o
4 V
P I
I
I
I ,
. / G
DN. 5
WITCH IN
i
FAX
I
o
f,^ I � I
l I
U
II I
G _ FRONT ENTRACE 29 i Mai
.z 3w 3
� I
_ I I 3 I II
31
S
M I �
�
(SITTING AREA) II 2�
3� 35 16 29
I
I
I
6 l
I�
T
EEC .
111
L
31
I I
I
SPOT L IGHTS Z
GF
I
- 15 P
I I�I�II
'GF PNL
I I1 _ ^ � 12 � O ' . _ � 1. I 23 Imo •
_ 13 2m 6'-0' HEIGHT AFF 29 26 Motion 23 / ^W�i SITTING
�' _ _.-. - pA o
r-- - 14 CFI; - - 20U FOR ALA PANEL ((� _ _ Detector RE L
---- - III
Mot n 3 I� 34 tt27 ---� 1 23 ----- 3w 15 o
16 3w
SITTING De ctor �
GF l i WP. aw 21
1
AREA i ^ _ � I
1 RE IJ
I
GF.
OFFICE 4 ,
2m
OF CE
9 IS 33 Ig 34 O
Bl11LT-IN
, I GF I.
al
DISCONNECT. 1�
O FAX _
AHU
O
I
C
i
- 20 26
�. � 23
1/ 23 PH 19 UP v
1
U- 21
1
i
z ,
I
P
I
,- 20 kI 8
1
2
i CFI. HU, n --- -- - 18 � / \ SITTING *2� '
11 PORCH < 'I
;XITCNEN - A
2
I 2
I
FRONT
I� Iz
I RON
_ 1
li
- 8
s
DESK � SITTING /
22 --- , 18 2� �, � �' Detector
BUILT-IN AREA Motion
DISCONNECT.
---- OFFICE #2
I �\ � a 23
II
I 9
I --- I � . - - , - � CFI• � =20 � � ' FAx�
�_ I 24 ` � I � I
- • ----- y O ' — PH
24 10 �,
24 ! s` T 21
I I � ; PORCH I �' ,
I
T4� PH i8 ; ! MCI
22 O 22 —� 3� 18 21
25 23
P
t ,
- 24 CONFERENCE 13� I'
1 - 34
3w
rn ?�
I
fl
I 23 1
,
R
M 23 I
FAX I
4
24 f� 25
IM OFFICE "S Motion 12 17 -' _; o
a C
PH 33 33 25 C=
22
Detector o
, , r . O
I I J
I
J ?
---- —ANOE, t-------- U
--- ---- 1----- ------------- ---------- j - _ _ - / `'-f' '••..
28 sc
28 Ramp
I
` W s
I _
�J
I
IN
SWITCH
_ _ _ FRONT ENTRANCE o W
----- - ---- - - - - - --- X
(SITTING AREA) X
p� r
m
I w
w
li =
� L CTR'f GAL FLOOR PLAN ELECTRICAL FLOOR FLAN
w
zi
SECOND FLOOR PLAN SCALE: 1/4'= I'-01 FIRST FLOOR PLAN SCALE: 1/41° 1'-0'
T 77T777
I