Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
00-1291-002
O V C p � I O • DOOR SCHEDULE - :-- _ CO SQUARE FOOTAGE CALCULATIONS Door WT. HT. THK. MATERIAL TYPE THRESHOLD WEATHER STRIP HARDWARE LOCK FIRE RATING ROUGH OPENING REMARKS o KEY NOTES 1 6'-0" 8'-0" 1-3 8" MTL. CLA SWING MTL. Y EXT. KEY L DEADBOLT - DBL „ hI AT A MAXIMUM. F REINFORCEMENT BAR (SEE ADJACENT ENGINEERING CALCULATIONS COVERED AND SPACED COVEREDOO�VRrnLMNG AREA: 2,159 8 67Q SQ. FT _ _ - _ _ _ = _ - ISS ANCE FOR 2 2'-8" 6'-8" 1-3/8" MTL. CLA SWING MTL. Y DEADBOLT 45 MIN. C LABEL/SELF CLOSER, RABETTED JAMG� 3 2'-8" 6'-8" 1-3/8" WOOD H.0 SWING _ j TIE BEAM ABOVE SEE ROOF OR FRAMING PLAN FOR SIZE AND REINFORCEMENT GARAGE: 376.21 SQ. FT: 4 2 2'-6" 6'-8" 1-3 8" WOOD H.0 SWING - - - - - - 7 ❑BIDDING SET ONLY EGRESS TYPE WINDOWS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF TOOLS AND TERRACE : 52.00 SO. FT. 5 2'-0" 6'-0" - LASS SHWR SWING PROVIDE A CLEAR OPENING OF NOT LESS THAN 20"x24" IN HGT. AND 5.7 SQ. FT. IN AREA. THE TOTAL BUILDING AREA : 2,655 SO. FT. 6 8'-0" 6'-8" 1-3/8" ALUM./GL SLIDING MTL. Y - - - -- - []CONSTRUCTION SET ONLY BOTTOM OF THE OPENING SHALL NOT BE MORE THAN 44' FROM THE FIN. FLR. LEVEL NOR SHALL _ ANY PART OF THE OPERATING MECHANISM BE PLACED HIGHER,THAN 54" FROM THE FIN. FLR.. SEE 7 5'-0" 6'-8" 1-3/8" ALUM./GL SLIDING MTL. Y ' - ❑BUILDING PERMIT SET ONLY 8 2'-0" 6'-8" 1-3 8" WOOD BIFOLD N.F.P.A. 101, 21-2.2.3 (C) s REV1 ® ALL WINDOWS SHALL BE COLONIAL AND THE FRAME SHALL BE E.S.P. (COLOR WHITE) 9 4'-0" 6'-8" 1-3 8" WOOD BIFOLD _ _ _ _ _ _ REV2 11/2�ROUND ARCF� WINDOW ABOVE SEE ELEV. SHT.`'' 10 6'-0" 6'-8" 1-3/8" WOOD BIFOLD - 10 h 11 7'-0" 6'-8" 1-3/8" WOOD BIFOLD - REV3 12 8'-0" 8'-0" 1-3/4' MTL. CLA OVRHD MTL, Y EXT.LATCH - GARAGE 11 ELLIPTICAL ARCH WINDOW ABOVE SEE ELEV. SHT 13 2 2'-6" 8'-0" 1-3 4" MTL. CLA SWING MTL. Y EXT.LATCH 12 TRANSOM WINDOW ABOVE SEE ELEV. SHT. 14 2'-6" - 8'-0" 1-3/4" WOOD H.0 SWING MARBLE - NUMBERS OF ADDRESS SHALL BE VISIBLE AND LEGIBLE FROM THE STREET FRONTING THE 13 PROPERTY AND SHALL BE A MIN. OF 3' IN HGT. NOTE: *3 ALL BATHROOM DOORS TO HAVE A MARBLE THRESHOLD. ENTRY PORCH AREAS OR TERRACES SHALL BE CLAD WITH 5/8' STUCCO FINISH ON METAL LATH OVER 14 R OVER 1 2 C.D.X. PLYWOOD NAILED AT 4" ON CENTER TO TRUSSES. AFFIX SEAL HERE ONE LAYER OF 301b. FELT PAPER / USE 10d NAILS 16 ALUMINUM GUTTER AND DOWNSPOUTS. PROVIDE CONC. SPLASH BLOCK AT ALL DOWNSPOUTS 22 20"x22" KNEE SPACE AT BATHROOM CABINET I Li Li 25 30" HGT. BATHROOM MICA CABINET WITH 4" TOE SPACE 26 PROVIDE FULL LENGTH MIRROR ABOVE BATHROOM CABINET WITH BEVELED EDGE FINISH 27 BATHROOM FLOORS SHALL BE OF IMPERVIOUS MATERIAL -- _ 90-8 - EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT E OPENING OF THE 29 LOCKED DOOR FROM THE OUTSIDE IN AN EMERGENCY SEE NFPA 01, SECT. 21-2.4.4. SAFETY GLASS CATEGORY 2 AT ALL GLAZING WITHIN 60 ABOVE FINISHED FLOOR AT 42'-1" _ 16'-1" 3L'-7" N 30 TUB AND SHOWER SEE N.F.P.A. 101, 21-2.4.4 7'-7" 1 '-9" 2'-8" 5'-3" 9'-2" 5''-4" -4' 4'-3" 3-5 8'-5" 2'-3 10-5 _ 16-6 3-5 31 WINDOW SHALL HAVE OBSCURED GLASS _ 32 FURRED OUT DRYWALL WALL 3' FOR PLUMBING STACK 55 ALL PLUMBING FIXTURES MUST COMPLY WITH WATER CONSERVATION ORDINANCE No.91-15 58 DISC. F+� 33 I ' 38 DRYWALL PARTITION BENEATH CABINET COUNTERTOP (34 1/2" HGT.) H HR 50 ao _ HR 40 0 oO SPACED 12" O.C. PROVIDE MID HGT. o � _ © 13 a W DRYWALL PARTITION 7'-6- HGT. WITH WD. STUDS ROW OF 2x WD. BLOCKING 8' 13' 10" 4" . . F I 4» �. 41 39" CLEAR SPACE FOR FUTURE REFRIGERATOR II I F5& 1�, 3 7 SH AT KITCHEN CABINETS 59 I I 11 0 O D—2 I I I O W 42 PROVIDE FULL MICA BACKSPLA W PROVIDE SLIDE-IN ELECTRIC RANGE, OVEN, MICROWAVE COMBINATION UNIT 0 60 II _ o 17'-1" II"' 8" 72" X172" O ^ 4� 44 P II CLOSET OD ABOVE RANGE ELEC . ' 61 I I PICTU E WINDOW HR 4030 0 45 PROVIDE SELF CIRCULATING EXHAUST HO 57 = II I a o II OBSCURE . ® PROVIDE DOUBLE SINK WITH STAINLESS STEEL FINISH WITH GARBAGE DISPOSAL MAIN �, II 74 ^ 3 ° II °' R 3050 00 HR 305 II ao I�oo SAF. GL. C T. II �..�11 12" WIDE BY 30" HGT. KITCHEN CABINETS PROVIDE 2x BACKING AT WALL 52 DISC. 56 li 11 ? 30 FAMILY R 0 0 M I I N 0 0 0 0 0 o v a 013 • • 47 o I I 26 I I ° I I W. C. 72 C2O . .PANTRY WITH 5 EQUALLY SPACED SHELVES IN DRYWALL FINISH II 25 II27 i j o w I I r-----_ ---° II , NOOK ELECTRIC METER MAIN DISCONNECT II 18 29 I I r 53 DRYER VENT SHALL NOT EXCEED MANUFACTURER'S RECOMMENDATION AND/OR 25' L -F � II 2r_q» » g'_g" 3'-0" II 12'-0" 8" o0 8'-5" �t 8" 13 7" 4'' I 6'-6" I 4" it 5'-2" 4„ 2'-3" 8" ol' R 0 0 M V 38 I I !! ; i cnl( 24 27 2 95 1 aAIR CONDITIONER COMPRESSOR SEE MECH. PLAN FOR TYPE COMPRESSOR SHALL BE 0 u C1 54 BOLTED TO 42"x42" CONCRETE PAD WITH 6 REMINGTON POWER ACTUATED FASTENERS. -� 5 `� OI 26 30 29 COMPRESSOR SHALL BE INSTALLED AT FLOOD LEVEL SEE SITE PLAN FOR HGT. REQUIRED �, 108 I I 75 74 ���_4- 7s - -I (6� I �I I MASTER Q+_.$ a SEPARATION OF 18" II : 14 i i \/ I I \ 38 g I I I I I I O co * �' N 5� COMPRESSOR MAIN DISSCONNECT SHALL BE INSTALLED AT A MIN. N 78 0 , I I \ / I I 11 I wl I.I BATH _ it 64 I I i\ II °�\\ ii/ III !.,. N 0 �, c 56 ELECTRICAL SERVICE PANEL AT 60" ABOVE FINISH FLOOR ® II i i \ / ii 9 j g - / 57 ELECTRICAL METER SHALL BE INSTALLED 48" BEHIND FRONT WALL II 0 0 10 `I ! I O \\ �, � r i t A R O O NI -- - \ � PROVIDE HOSE BIBS SEE DETAIL ON PLUMBING SHT 1 rY `° `� W 72 - I I < I " iV V. I .C I o i l (�4 !�W 58 ( 0 1 I I K I II HEN I I ` z 59 ELECTRIC WASHER MIN. REQUIRED CLEAR DEPTH IS 30" IN CLOSET ° II IMP 317'-4"� I -- II II o ' ELECTRIC DRYER MIN. REQUIRED CLEAR DEP�I IS 30" IN CLOSET PROVIDE 6" WALL BEHIND >; II 4 11 0 4' 1 10 - 9 MI6' 4" __ 13'-6' _ 4" 13-7' 4 II ,I_._ 6-6 I 4 I ` i M 0 W rT, 60 FOR DRYER VENT i, 4" II f I - I IF,F.E.=-0.583 72. 5,-0„ 4» 5'-2 N � z €''^ Q M--� I PROVIDE 50 GALLON WATER HEATER WITH A ENERGY FACTOR OF .87 SEE ENERGY CALC. N k NOTE: �+ 41 44 46 `(' 11 j o A a I--1 A4 61 PROVIDE HEAT TRAP AND STUB OUT FOR FUTURE SOLAR OR H.R.U. II SHALLLMEETE IN FLOODYROOM BEDROOM 4 � 42 45 48 i I �° LIVING R 0 0 M 64 (14�v v v v o RECESS ELECTRICAL OUTLETS AND SWITCH BOXES IN ONE HOUR FIRE RATED PARTITION II LEVEL ELEVATT N. I O3 97 II °° _ F HB 63 SHALL BE METALLIC WITH A SURFACE NOT TO EXCEED 16 SQ. IN: AND THE SURFACE AREA ® 109 "' II i 30 Co E87 OF THE BOXES SHALL NOT EXCEED 100 SO. IN. PER 100 SO. FT. OF WALL SURFACE 7 GIRDER TRUSS ; 26 58 BOXES LOCATED ON OPPOSITE SIDE OF PARTITION SHALL BE SPACED 24" APART OF 13 a _ ; o , 25 6 � HORIZONTAL DISTANCE --- 12 ----- ---- ---------_-- -------------- - = z =_ - a� --- o I- -----� N I I D-2 ATH`� 27 . 4 TC 2 110 11 TC Co HR 4C50 II I .—� M 64 ALL APPLIANCES AND CARPETS SHALL BE INSTALLED AT THE TIME OF CLOSING 1 n 1 &2 O III N II 29 0 cn 22"00- METAL CLAD PLYWOOD CEILING SCUTTLE. THE SCUTTLE SHALL BE PROTECTED ON 66 GARAGE SIDE WITH NOT LESS THAN 25 GAUGE SHEET METAL SEE DTL No. 18 SHT. D-1 0 `� 68 LINEN CLOSET PROVIDE 5 EQUALLY SPACED WIRE SHELVES 12" DEEP ______ 3'-2" _ 4&g 10-2' I I 13'-6" �:,�r 4„ 72--� --5_=1J'�- 4„ --II--72--- - 71 SEE DETAIL No. 8 SHL No. D-1 FOR METAL STUD PARTITION DETAIL D-2 _ _ 0 O O I F�-� c n 72 PROVIDE 12" WIDE WIRE SHELF SHELF 72' ABOVE FIN. FLR. 11 2 10 0 ^� n r n " I r » " r » N W 74 ONE HOUR FIRE RATED WALL WITH 5 8 TYPE x DRYWALL ON METAL STUDS 24 O.C. 16'-p" T-3" 6'-4" ,8" 14'-5" 8" " 9'-8" 4" 8'-0 4" 3 4 -2 4 FU' 8-0 8 10-0 �g xA _ W.P. 1200 FROM THE DESIGN MANUAL OF THE GYPSUM ASSOCIATION SEE DTL. 'Ns. 9 SHT. D-1 ONE HOUR FIRE RATED CEILING WITH 5/8- TYPE x DRYWALL ON 1x3 FURR. STRIPS AT 1'-4" D I N I N G I I 0 0 M 107 I! 2 75 16 O.C. AND 3.5 BATT INSULATIONS DETAIL No. 10 SHT D-1 = F 0 Y R I I D 4 POST DANGER SIGN IN GARAGE TO READ: DANGER DO NOT OPERATE ENGINES WITH DOOR I rcD _< 76 CLOSED CARBON MONOXIDE EMISSION IS LETHAL THIS SIGN SHALL HAVE 1/2 HGT. © II'� o 0 o a o TC o � y II� o �C. TC v LETTERS. O 64 I I '� k 0 77 2x6 P.T. WOOD PLATE WITH 1/2" DIA. ANCHOR BOLTS SEE DET. No. SHT. No. O ti� it F BED OOM 2 BEDRG)OM 3� CDP z C 60 SO. IN. SCREENED VENT BETWEEN GARAGE FLOOR LEVEL AND NO HIGHER THAN 7 :� OS `"'= � = 78 ABOVE GARAGE FLOOR LEVEL PROVIDE 1 VENT PER EVERY 8 WIDTH OF GARAGE DOOR O' " '� » �' 11 n " "' EVERY CLOSET DOOR LATCH SHALL BE SUCH THAT CHILDREN CAN OPERATE THE DOOR °O _6 — —6_4 _ — — _6 8 11_6— — — — — — — 4 — — — 1' -6 — — — 8 ;° ^ ►—a O — — — 79 FROM THE INSIDE OF THE CLOSET SEE NFPA. 101. SECT. 21-2.4.3. - - - - - - - - i= - - - - - - - -- - - - - - - - - -r - - - - - - — _ IF M Y CENTERLINE OF GIRDER TRUSS ABOVE SEE ROOF PLAN OR FRAMING PLAN. PROVIDE A TC HR 4010 I I C° '.h. 4, Co En 80 MIN. 2 FILLED CELLS AT ALL GIRDER TRUSSES 2 7 � 10 o PROVIDE 1x2 FURRING STRIPS 24 ON CENTER WITH ONE CUT NAIL EVERY OTHER COURSE i I I�" I _ o M con rn o � 83 OF MASONRY WALL � I ENTRY o 0 0 0 0 0 T- o - - - _� — HR 3 50 HR 0 0 i0 d ,u: o C� 0 86 16" WIDE WIRE SHELF ABOVE WASHER/DRYER —— — I , a N 89 1/2" DRYWALL WALLBOARD FINISHED AND PAINTED WITH 2 COATS LATEX WALL PAINT 11 rpw a-� _. C7 �r 94 CLOSER "C" LABEL DOOR RABETTED JAMB SEE DOOR SCHEDULE ctii o 4-6 2-10" 7'-4" 11 -4 91-110 4-6 lot—ill 10'-0" W '� �' a a 95 13" X 24" MEDICINE CABINET 60" ABOVE FINISH FLOOR 30-11 n _ " ELECTRIC DISHWASHER BY OTHERS 97 `` 00000000 ', C) ~ n 99 EXPOSED KEYED MASONRY BLOCK PAINT FINISH 15'-9" 9'-4" 24-8 4��€ ., � HIM tj J � 100 1 HR. RATED CAULKING AT DRYWALL PARTITION SEE DETAIL NO. 1 SHT. D-4 " 000a00000 w 102 R-11 INSULATION AT WALL 90'-8" -- M c- 107 CONCRETE PAVERS SEE DETAIL NO. 5 SHT. D-4 , o ro 148 CEMENT FINISH PAINTED " ' " o CL 109 6" DRYWALL FLOOR P L_ A f�I SCALE: 1 /8 = 1 — 0 cr 110 FIXED IN PLACE GARAGE DOOR. A-I H ,1] -.. U = S Q � i U O LU LO Im Of U3 G