Loading...
08-04-09 Item 8SOUT61 South Miami U IflCOHPORnTEO • � 1021 C o K 10 P 2001 CITY OF SOUTH MIAMI OFFICE OF THE CITY MANAGER INTER - OFFICE MEMORANDUM To: The Honorable Mayor Feliu and Member of the City Commiss1ioonn Via: W. Ajibola Balogun, City Manager _L'°` Jose Olivo, Public Works & Engineering Director ' Q From: Rodolfo de la Torre Assistant Public Works Director Date: August 4, 2009 Subject: Requesting purchase order for the renovation of irrigation system at Palmer Park. Resolution: A RESOLUTION OF THE MAYOR AND CITY COMMISSION OF THE CITY OF SOUTH MIAMI, FLORIDA AUTHORIZING THE CITY MANAGER TO ISSUE A PURCHASE ORDER TO SNG LOW VOLUME IRRIGATION SYSTEM INC. FOR THE RENOVATION OF EXISTING IRRIGATION SYSTEM AT PALMER PARK IN AN AMOUNT OF $18,000.00 TO BE CHARGED TO PARKS MAINTENANCE CONTRACTUAL ACCOUNT NUMBER 001 - 1750 -519 -3450; PROVIDING FOR AN EFFECTIVE DATE. Request: Authorizing the City Manager to execute a purchase order with SNG Low Volume Irrigation System Inc. for the renovation of existing irrigation system at Palmer Park. Reason/Need: The City of South Miami Palmer Park, located at 6100 SW 67th Avenue houses the City's main sports facility, consisting of 5 Baseball /Softball fields, football fields, soccer fields, La Crosse fields and serves as The City of South Miami Grey Ghost Football home field. The existing irrigation system at the Park is inadequate and does not provide proper irrigation coverage to all sports field areas, which is essential during the dry seasons. In addition, the existing system does not have the capacity to water the turf and clay infield areas separately, which is very .important not to cause damage to clay infields. The existing system has suffered numerous repairs through the years and is bandaged in most areas. New renovations to the irrigation system will include upgrading the main line from 3 inches to 4 inches, adding sprinkler heads, additional zones, separating of zones and the installation of rain sensor. These renovations will give us the capacity to properly irrigate the Park and manage water consumption more efficiently. SNG Low Volume Irrigation Inc. was selected as the lowest responsive bidder from the following three bids received: 1. SNG Low Volume Irrigation Inc. $18,000.00 2. Superior Landscaping $18,100.00 3. Research Irrigation, Inc. $28,200.00 Cost: $18,000.00 Funding Sources: Parks Maintenance Contractual Account number 001 - 1750 -519 -3450 with a current balance of $ 35,521.00. Backup Documentation: • Proposed Resolution. • Estimates from three vendors. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 RESOLUTION NO. A RESOLUTION OF THE MAYOR AND CITY COMISSION OF THE CITY OF SOUTH MIAMI, FLORIDA AUTHORIZING THE CITY MANAGER TO ISSUE A PURCHASE ORDER TO SNG LOW VOLUME IRRIGATION SYSTEM INC. FOR THE RENOVATION OF EXISTING IRRIGATION SYSTEM AT PALMER PARK IN AN AMOUNT OF $18,000.00 TO BE CHARGED TO PARKS MAINTENANCE CONTRACTUAL ACCOUNT NUMBER 001 - 1750 -519 -3450; PROVIDING FOR AN EFFECTIVE DATE. WHEREAS, the Mayor and City Commission wishes to renovate the irrigation system at Palmer Park. WHEREAS, the renovation of the irrigation system is essential to properly maintain the Sports Fields located in the Park. NOW, THEREFORE, BE IT RESOLVED BY THE MAYOR AND CITY COMMISSION OF THE CITY OF SOUTH MIAMI, FLORIDA THAT: Section 1: The Mayor and City Commission authorizes the City Manager to issue a purchase order to SNG Low Volume Irrigation System Inc. for the renovation of the irrigation system at Palmer Park in an amount of $18,000.00. Section 2: That the expenditure will be charged to Parks Maintenance Contractual Account 001- 1750 -519 -3450 with a current balance of $ 35,521.00 before this request. Section 3: This resolution shall be effective immediately. PASSED AND ADOPTED this _day of 2009. ATTEST: CITY CLERK READ AND APPROVED AS TO FORM: CITY ATTORNEY APPROVED: 1/ : • Commission Vote: Mayor Feliu: Vice Mayor Beasley: Commissioner Palmer: Commissioner Newman: Commissioner Sellars: SNG Low Volume Irrigation System INC. 12241 SW 10 terrace, Miami, Fl, 33184 Phone: 305 926 -8645, Fax: 305- 226 -6520 June, 18, 2009 Att. Mr. Jorge gonsalez Palmer Park PPS Miami FL 33 1 -- Ref: PPS Replacement & Renovation of Existing Irrigation System Replacement Existing 3" main line with new 4 "Main Line, ADD PVC conduit, control wires & New Controller & Main Sensor. PROPOSAL SNG Low Volume Irrigation is pleased to submit the following PROPOSAL for our professional services for the above listed Park. We will provide all labor, materials and equipment necessary for the replacement & renovation of the existing system. Scope of work: 56- 96504 Rain Bird pop -up sprinkler. 56 -1' pre fab swing joint. 7- #200 PEB Rain Bird Automatic Valve. 7- #VB -12 valve box *Cap heads in clay field zones (outside clay) *Moved (4) heads on field 41 'ADD (3) heads on Field #2 *Cap (5) heads 600'- 4` SCH 40 PVC PIPE. 600'- 1" PVC Conduit. 1- ESP- LX- 12 M rain Bird Controller. t- Rain sensor 5,00o- $14 THWN Control wire * Misc. fittings. Warranty: If there is a defect in any of the manufactured parts, it ,,fill be replaced within one year of its purchase and 90 days of labor will be provided during the time in which the certain part is replaced. Total Cost: $18,000.00 Method ofPavment Find 118.46 -0.00 Upon completion of the work as detailed above. Checks should be made payable to: SNG LOW VOLUME IRRIGATION SYSTEM INC. Interest at the highest lawful rate of interest per collection costs, including reasonable attorneys fees, will be charged on past due accounts. This PROPOSAL may be withdrawn if not accepted within 30 days from this date. ACCEPTANCE OF THIS PROPOSAL This PROPOSAUCONTRACT is satisfactory and is approved. You are authorized to do the work as specified above. Payment will be made as shown above. Authorized Signature: DATE Jul 241 . 2000, 3:55PM No. 7931 P, 1/1 SUPERIORPO BOX 35.0095, Miamt, F4 35135 -0055 LANDSCAPING & LAWN SERVICE, INC Ph1 (305) 634-0717 Fx:(305) 6340744 Proposal i:: 11299 Date: 7/19/09 Submitted to: City of South Mlsml Jorge Gonudez 6130 Sunset Drive South Miami, Florida 33143 Tat 305.796.1568 Fax, 305. 08,7208 Project: Palmer Park DESCRIPTION OFSMICE: Pmnsmg Includes 39 7 600, 600' 5000 I 1 Replaet existing 3`mafnfine with new Cmainlinc with Conduit, control v,4re & new controller & rain sensor, and add 5 zones Falcon heads with I' awing jainra 3' Valves with Votive boxes Lateral PVC Pipe 4'seh 40 ,\fain line 1' Conduit Wire ESP 12 L\ Rain Sensor Mire Flaings Irrigation Toral b. " 10,100.00 Proposal Toml $ 18,100.00 The purpose of this proposal it to furnish irrig2s5on services at the above project in srcordmce with the attached scope and tatterials that is bard on pLsnsand specification stated ardaceording m srndsrdpnedces. The price of this proposal is valid for" (60) 6ys from the date of rhis proposal I €ynuhneenyquestions,picatconvict: jmusAcosm As- 305,634,0717 Guarartue Superb, Iacdsespiog or tasrn Service, tae. M "I cable cr atpo,uible Imtny knot, tepah of replacement of say of the abov emmloted due toblg b Hinds. ha0, 0ghmtngaconns, heavy mimvandalkm .Qoodtheat,coostr mon,meccap`egvea or odceradon. Inadequate irrdgadea, tammdaer, launct ea or ocher Atrsof(iod Psymmr Terms: Pgwcac sot per ConnatrTmn& Patr due atoounta will sequm an eighteen percent (ft) iarc= per, pen. Sbenld eollectton amvnits be naemrcd, she chmt dvall be respowbit for nay refired exinoses 4:ludieg but rot limircd to actbmey. ftes and court cwm There is a Of) doll r (sm.00) fee for oth dwk wrumed for non -su0mm funds. Any phattems mode to,t& d=m:r,..0meke it vob1. , ACCEPTANCE OF PROPOSAL Wberefam,ConnsemrandOn u, erCrmer' sA,% Mr, laveaccepted the top- gad [tunsoftbisproposal0%*,Wrm Oann's Agent givts express perntdrrion to Contractor to enter said property and confirms that is clear from any hidden danger or defects. Owner or Owner's Agent Con tram r. ' Stgxdor Lmdsesf ft Sr lawn Scr lm fete By. k: I Name.. Namt: Title: Tide Dart: LMrt: RESEARCH IRRIGATION, INC. 11 700 t.W. 102nd RD i'• 10 • MTAM1, r•L0111D.A 33173 PT101:13: 303- 863 -939U • 1=A:{: 3305- 863.9221 PROPOSAL PROPOSAL SUIPMnTED TO: PHONE 047E GIN OF SOUTH MIAMI 4109109 STREET: JOBNFxtE PALMER PARK c" STATE. JOBL=71OY SW 67TH AVE Arrmox CM n0 . ATTN: GEORGE GON7ALEZ (305 ) 668.7208 We hereby submit specifications and estimates for: REPLACEMENT & RENOVATION OF EXISTING IRRIGATION SYSTEM INCLUDES: - (NEW IRRICATION SYSTEM FOR OUT FIELD AREAS) 56 - #6504 RAIN POP -LIP SPRINKLER 56- I" PRE FAB SWING JOINT 7- #200 PEB RAIN BIRD AUTOMATIC VALVE 7- #VB -12 VALVE BOX CAP aEADS ON CLAY INFIELD ZONES — (OU'T'SIDE CLAD • MOVE (4) HEADS ON FIELD #I • ADD (3) HEADS ON FIELD #2 • CAP (5) CAP HEADS • UTILIZF. EXISTING MAIN LINE AND CONTROL WIRE * MISC. PVC SCH 40 PIPE & FITTINGS We I'ropoSe, hereby to furnish material and labor — complete in accordance with above specifications, for the sum of: TWT -NrY- THREE TBOUSAND, 'TWO HUNDRED FIFTY DOLLARS gars �S 23.250-00 Pd7' -'I1. L=ade r. mlw.. III All metetiai is guaramee<i to be as APrxified. All work to be cmnpleltw In s vrononanri S Authorised manner aacOrding to standard practices. Any altarallon or deviation from above Signature — AlAff spacificatlOns invoking extra costs will be executed ony'upoi wdttan orders, and will KENNETH ,, PRIESIMN T become an extra charge over and above the estimate, All agreements r riftem upon stlkes, scoideft or delays began¢ our eontrol. Omer to carry rim tomado and oiher Note: This proposal may be withdrawn by us if not accepted within 30 days, ne=aty Insurance. Our workers are fully covered by Worlmn's compensation Insurance, Acceptance of Proposal— Signature rhe above prices, specifications and conditions arc satisfactory and — - ire hereby accepted, You are authorised to do the work as specified, 'ayment d] be made as outlined as above. ilgnature Signature .-R01 DMGATCON, WC. NO M 1 1700 NX 102nd RD r' l It • NTW41, FLORIDA 33175 PAOtvG: ?� ?� 56:i -9 ?90. FAX: 305- E63 -9221 a PROPOSAL FROPOSAt aUaMTEO T0: PHM DATC ; 4109!09 CITY OF SOUTH MIAMI aTAEE: JOa MP7JE PALMER PARK C , TATB. ZIP CME JOB Loc,1 N . SW 67TH AVE nuie ATTENIIOk FAX ATTN: GEORGE GONZALEZ (305) 668.7208 t vve nereay buuunt *wvuwt,auuna anu REPLACE EXISTING 3" MAIN LINE WITH NEW 4" MAIN LINE, ADD pVC CONDUIT, CONTROL, WIRES & NEW CONTROLLER & RAIN SENSOR. INCLUDES: - 600' - 4" SCH 40 PVC PIPE 600' - 1" PVC CONDUIT 1 - #ESP -LX -12 M RAIN BIRD CONTROLLER 1 - RAN SENSOR 5.000- X14 THWN CONTROL WIRE * MISC. FITTINGS We Fropose hereby to furnish material and labor — complete in accordance with above specifications, for the sum of PM, r- tm be raft s tat== All material is Ouarentand to be as apecffaod. An work to be want-led rn a workmanlike Authorized /All manner acwrd'mg to standard practices. Any alteration or deviation from Above Signature N HR-8N 1 a specifications involving extra costs will be executed only upon ttdtten orders, and wel become an extra onange over and above the estimate. All carp ?menu contingent upon strft% accidents or delays beyond our control. Owner to carry fire, tomado And over Note: This proposal may be withdrawn by us V not accepted within 30 days. necessary insurance. Our workers are fully covered by Workmen's compensation Insurance. Acceptance of Proposal— Signature The above prices, spo..rifiC2tions and oonditioas are satisfactory and are hereby accepted. You are authorized to do the Work as specified. Payment will be made as outlined as above. Signature Signature