7000 SW 62 AVE EB-96-049-003 NOTES
Automatic Irrigation System
Water Demand/Zone Refer to Plan
Water Source Well
Pressure Required 40 psi
Pumping Capacity 40 gpm @ 92 FT HD
Pump Spec (Typical ) 2 HP High• Head Self-Priming Centrifugal
PLASTI E BOX
GENERAL OVER
SPRAY HEAD 6' ABOVE WALK, CURB,WALL,ETC. WITH COVER MARKED
•RCV' EPDXY FILLED
CONNECTORS
System shall be installed in accordance with local codes, Contract Drawings , PLANT MATERIAL
a' MAX.
and Contract Specifications. 12' FROM WALL, FENCE
•This irrigation design shall be used as a guide only. Contractor shall FINISH GRADE
e to match on site conditions . . s• MIN. 1/2'NTURCOVER
install the system µ
AREAS
OUNDCOVER
This system has been designed as a typical block valve type using Toro 570 FINISH GRADE
FINISH GRADE
series sprinklers, Toro 252 series in-line valves , and a Toro Vision controller. \
Serve SOLENOID ACTUATED a „ LATERAL LINE
The water source shall be a well . A rain switch shall be installed to con PLASTIC POP-UP SPRINKLER REMOTE CONTROL S (COVER D NOTED
- 4 VALVE ,,F N LEGEND
water. SCH 40 PVC RISER t CU.FT,PEA GRAVEL COMMON WIRE
Contractor is advised to study the plans for additional information and to PVC LATERAL WOVER (PIRt IN A COIL)
visit the site to become familiar with existing conditions . AS NOTED IN LEGEND ) NOMINAL WF1�INACOIL)
' 4'x21/a'x8"SOLD
318'POLY TUBING FOR BRICK AT EACH CORNER >
NOZZLES a GPM AND LESS SCH 80 PVC NIPPLE
To insure proper operation of this system, pumping capacity, valve sizes , zone V
/i COMMON AND CONTROL
capacities , sprinkler spacing, pipe and wire sizes , installation notes and PVC LATERAL (COVER AS �. WIRES (PROVIDE A COL A.)
details ,.: and specifications shall be followed as shown . ` � • NOTED IN LEGEND) WIRENACOIVER
MAINLINE (COVER AS
NOTED N LEGEND)
NOTE:USE 4b°ELLS IMMEDIATELY OUTSIDE OF VALVE BOX,AS NECESSARY,
PIPING
• FOR TRANSITION TO REQUIRED tATERAL LINE DEPTH.
Pipe routing is schematic only and shall be adjusted for on site conditions . PVC FITTING
Lawn Pop-up Sprinkler Remote Control Valve
Pipe shall be installed in accordance with local codes and pipe manufacturer ' s
recommendations.
Shrub Spray Sprinkler
Pipe routed under pavement shall be sleeved in SCH 40 PVC. Contractor shall
verify the size, depth, and location of all existing sleeves.
Pipe installed above grade at the pump station shall. be SCH 40 galvanized
steel . All other piping shall be Type 1120 PVC. The main line and suction
line shall be SCH 40. Laterals sized 1 " to 2 11. shall be SDR 26 , Class 160.
Laterals sized 3/4" shall be SDR 21 , Class 200.
Pipe sized to maintain flow velocities below 5 feet/second and to limit the
friction loss in the piping network.
Pipe shall be installed so backfill depths are maintained at 12" for the main -
and all laterals routed under pavement , and at 8" for all other laterals . _
Backfill shall be of suitable material free of rocks , stones , or other debris
that • would damage components of the system.
A gate valve shall be installed at the source for isolation. This gate valve
shall be installed in a valve box. INSTALLATION DETAIL - RAINSWITCH AUTOMATIC CONTRc-)L
CONCRETE VALVE BOX WIT
COVER MARKED'GATE VALVE'
�f
SPRINKLERS .A.., _ M
_
1/2" N TURF,Y N
GROUND COVER . INSIDE WALL -
Sprinkler locations are schematic only and shall be' adjusted for landscaping, - � Y •
mounding , prevailing wind , site lighting, etc. , to insure proper coverage with
minimal undesirable overthrow.
ELECTRICAL CONDO
FNISH GRADE l
_
�'�� f(7 .•o Q,
a' MAX. PER LOCAL CODE'
Pop-up spray heads shall be Toro 570 series which shall be installed on flexible
swing joints consisting of Toro thickwalled poly pipe and 2" insert elbows . j t y' '� r f PvcMALEAOAPTER 1�LOC �E
GATE VALVE 1 - CODE -
Shrub type spray heads shall be Toro 570 series which shall 'be installed a -
standard height of 6" above plants , and shall be installed within planted --- — ---'- PVC MALE ADAPTER t
masses to be concealed from view. SCH 40 PVC risers shall be painted "flat l� I L E I;
AS NOTED W
LEGEND) j'1• '--' `.
black" to be less visible .
Adjustment features of sprinklers specified shall be utilized .to insure proper
coverage with minimal undesirable overthrow. Low angle nozzles and adjustable `'
arc nozzles shall be used where possible to minimize overthrow. SOD SOMi DBBRICK AT EACH
B~
EACH
1 CU.FT.PEA GRAVEL CORNER
Sprinklers located adjacent to pavement, shall be installed away from pavement
to minimize overthrow and the chance of damage by. vehicles , pedestrians , and NOTE FOR TRANSITION RELY ED MAE OF VALVE BOX,AS NECESSARY,
lawn maintenance personnel . As a general rule, pop-up spray heads shall be FOR 7RANSmON TO REQUIRED MANLNE DEPTH. 24 VOLT WIRE S !
REMOTE VALVES
installed in 6" and shrub heads shall be installed in 1211 .
Gate Valve ELECTRICAL CONDUIT
LONG SWEEP ELBOW
CONTROL SYSTEM
A Toro Vision 24 VAC electric control system shall be installed . One 6 station
controller shall activate 4 in-line valves . One valve shall be controlled
per station except where noted. A rain switch shall be installed to conserve
water.
Control system shall be installed in accordance with local codes and manufac-
turer ' s instructions . Proper grounding equipment shall be provided .
Controller location shall be approved by the Owner ' s Representative . A 1.15 .
VAC electric source is required per location. -
MNt OH ,UNUUI I l I 'Y H.1
Control lines from automatic controller to, in-line automatic valves shall be
SPRINKLER LOCATION DETAIL
#14 AWG direct burial underground feed type which shall be ( 1 ) installed in - / FINISH GRADE
accordance with local codes, ( 2 ) routed in the main line trench , and ( 3 ) POP-UP AND . SHRUB HEADS
buried to a minimum depth of 10 inches. Splices shall be made waterproof -
using approved methods : Ic, s"`u' "E"D TOP SOIL iljl 3'
valve a I� I �
An individual control wire shall be routed to each v al and valves which i - /
operate simultaneously shall be teed together at the controller . BACKFILL WITH
�� �C PREVIOUSLY
/ \ \ suLue MASS PREVIOUSLY
MATERIAL COVER AS
Automatic valve locations are schematic only and shall be adjusted for on If/ NOTEDAN
site conditions. Each valve shall be installed in a valve box. L�I.{ SPECS.
SAND OR FINE
i I \ MATERIAL PASSING _• .__.... • ,..: .::•.-.' 3'
Water conservation equipment shall be installed in accordance with manufac- I �•oa:
y / i2"- ROTOR)
1/4 SIEVE
turer ' s recommendation. 19
BUNDLE IRRIGATION °`'"' ~�''' ''
CONTROL WIRES AT
10' INTERVALS AND
�3 3'
PUMP STATION _ - - • -• • _ PROVIDE 1' EXPANSION 4. FOR PIPE OR CONDUIT 2' AND
Location of pump station shall be approved by the Owner's Representative . � ' LOOP AT 50'•INTERVALS SMALLER AND 12' FOR PIPE
Nuu 2 1/2' AND LARGER
Oa ROAD POP-UP 5PRIAIKLER•
Pump shall be a 2 HP high head self-priming centrifugal with a capacity of 6" FOR PIPE 2" AND SMALLER AND 12" FOR
40 gpm @ 92 FT HD for a 10 ' lift. A typical pump is a Sta-Rite #DS2HG. PIPE 2 1/2" AND LARGER WHERE CONThOL
WIRE IS IN SAME TRENCH -.IF ONLY ONE PIPE
IN TRENCH, PROVIDE 5" TO TRENCH WALL
Pump shall be housed in a well ventilated lockable pre-fabricated enclosure.
Pump shall be activated via. the controller.
lAT91UL •. _ Pipes in.Trench
The water source for this system shall be a well which shall be developed for
a minimum flow of 75 gpm and so the water available contains no harmful
material that would damage components of the irrigation system.
SCALE:
AS SHOWN
DRAWN BY. IL, M. ID- I
CHECKED BY ��- CONSULTING ENGINEERING SCIENCE, INC. -IL � , Dr D-'' ` �.�, TO QO BUILDING PARKING LOT
HEALT HSOUTH CORPORATION h ?0092
APPROVED BY' SUITE 100 '� T� � F '
2 PERIMETER PARK SOUTH 89 Z S SW 148th STREET IRRIGATION PLAN
DATE. APRIL 15, Iggd BIRMINGHAM, ALABAMA 35243 �—� MIAMI, FLORIDA 33176 (305) 378-5555 jl�4.0R•%.... N0. DATE REVISION SH.NO. OF
o PROJECT NO.: 93.30 � �