04-07-09 Item 25 PlanAWiliate of Baptist Health
a
1,- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF
DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING
SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT
IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH
UTILITY CONNECTIONS AS REQUIRED FOR OPERATION.
EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS,
THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS
CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS
IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF
THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO-
VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW-
NER.
2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING
THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE
AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO
BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS.
CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE,
AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE
CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER.
3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE
AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND,
NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON-
TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS
RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE _
TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE
RE -DONE,
4.- SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER-
FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAG
TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA-
IN APPROVAL IN WRITING PRIOR TO PROCEEDING.
5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND
USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES
TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT
NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE
FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND
SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER.
6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE
SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION
DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP
DURING THE CONSTRUCTION,IT IS ASSUMED THE CONTRACTOR BID
THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE
DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST
TO THE OWNER.
7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM-
MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION.
8; THE, CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY
BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER
EQUIPMENT TO PROTECT THE SAFETY OF ALL PFRSONS AND-T14 -2
PG ?OrEFPTY T HROUGHOU r THE ENTIRE PERIOD Or-- THE CONSTRUC _
TION CONTRACT.
9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL
OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT
WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED
BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK.
10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED
HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES
AS TO APPLICATION AND USE.
II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL
AND ALSO BETWEEN CEMENT AND METAL.
12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL
PERMITS TO COMPLETE THE PROJECT.
13: CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR
COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY
NONCONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION.
14: GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO
WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK,
EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/
REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED).
15: DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND
CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME.
16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE -
RETARDANT TREATED AS PER SPECIFICATIONS.
17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS /
PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE
EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY
OF THE DESIGNATED RATING.
18.- ELEVATION AND LEVELS,
A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB.
UNLESS NOTED OTHERWISE.
19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL
STUDS OR FURRING CHANNE!LS UNLESS NOTED OTHERWISE. SIZES AS
DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF
WATER RESISTANT G.W.B.
20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS.
AND JANITOR'S CLOSETS.
21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY
EXPOSED CELLS SOLID WITH GROUT.
22,- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK
23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE
DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND
ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL
COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND
APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO
INSTALLATION.
24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE
OR OTHER OUTLETS.
25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE
FURRED WITH METAL STUDS AND DRY WALL AND FINISI -ED TO MATCH
ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS
A. ELECTRIC CLOSETS C. MECHANICAL ROOMS
B. TELEPHONE CLOSETS D. STAIRS
26: WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS
PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO
STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL
PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE
FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH
APPROPRIATE FIRE S.T.0 MATERIAL.
27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR
SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR
ACOUSTICAL TILE FINISH.
28. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF
CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES.
29. STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS
EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2' -O".
UNLESS OTHERWISE NOTED.
30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED
STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE-
MENTS. CONT12ACTOIRSWALL PROVIDE ALL NECESSARY INSULA-
TION/FIRE PROTECTIVE COATING$.
31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND
THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES,
WINDOWS, ETC.)
32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT,
of South
A TT Y)ON PAIN R
L) A %.j J
t S AURAN't
EB0000924
LOUIS J. AGUIRRE & ASSOCIATES P.A.
CONSULTING ENGINEERS
2600 DOUGLAS RD. SUITE 605
CORAL GABLES, FLORIDA 33134
TELEPHONE: (305) 444 -1679
FAX: (305) 448 -1405
E -MAIL ADDRESS: GRALMAIL@LJAAPA.COM
INTERIOR REMODELING ONLY
FEBRUARY 18, !18
ARCHITECTURAL
A -1 DEMOLITION PLAN, LEGEND AND NOTES.
A -2 FLOOR PLAN, LEGEND AND NOTES.
A -3 REFLECTED CEILING PLAN, LEGEND AND NOTES.
A -4 EQUIPMENT PLAN, INTERIOR ELEVATIONS, LEGEND AND NOTES.
A -5 DOOR SCHEDULE, NOTES AND DETAILS.
A -6 FINISH SCHEDULE, DETAILS, NOTES AND PARTITION TYPES.
A -7 PENETRATIONS AND FIRE RATING DETAILS.
A -8 PENETRATIONS AND FIRE RATING DETAILS.
A -9 PENETRATIONS AND FIRE RATING DETAILS.
m 01114 *0 f4l Of 0 T_!'
MO.00 SYMBOLS LEGEND, AND GENERAL NOTES - HVAC.
M3.00 DEMOLITION FLOOR PLAN - HVAC.
M3.01 DEMOLITION FLOOR PLAN - CHILLED WATER PIPING - HVAC.
M3.02 FLOOR PLAN - HVAC.
M3.03 FLOOR PLAN - CHILLED WATER PIPING - HVAC.
M7.00 DETAIM - RVAC.
PLUMBING
PO.00 SYMBOLS LEGEND, AND GENERAL NOTES.
P3.00 FLOOR PLAN AND PARTIAL DEMOLITION FLOOR PLAN.
P5.00 DOMESTIC WATER AND SANITARY ISOMETRIC RISER DIAGRAM.
P7.00 DETAILS.
ILI
ORIGINAL BUILDING DESCRIPTION
EO.00 SYMBOLS LEGEND, GENERAL NOTES AND LIGHTING
FIXTURE SCHEDULE.
E3.00 DEMOLITION FLOOR PLAN LIGHTING.
E3.01 DEMOLITION FLOOR PLAN POPPER.
E3.02 FLOOR PLAN - LIGHTING.
E3.03 FLOOR PLAN - SYSTEMS.
E5.00 RISER DIAGRAM.
E6.00 PANEL BOARD SCHEDULES.
FIRE PROTECTION
FPO.00 SYMBOLS, LEGEND AND GENERAL NOTES.
FP3.00 FLOOR PLAN.
BUILDING
JURISDICTION : SOUTH MIA , MIAMI DADE COUNTY
PRIMARY USE CLASS : GROUP "S" SPECIAL STORAGE OCCUPANCY
NUMBER OF STORIES : 9 LEVELS (OPEN AUTOMOBILE PARKING GARAGE)
NEW PROJECT DESCRIPTION
PROJECT AREA: : TOTAL: 2,006 S.F.
SPRINKLED FULLY SPRINKLERED
FLORIDA BUILDING CODE 2004 EDITION
FLORIDA FIRE PREVENTION CODE 2004 EDITION
NEW
LAI, j
•,'
tall' CMITEC 1 LOkAL Y A 1 I :
WVIW-,, isRfR UMme
t AND
WITHOUT
WP
WATER PROOF
L ANGLE
L
WT
• AT
uuP
L
LENGTH
G CENTERING
LAM
LAMINATE
O DIAMETER
LAV
LAVATORY
• POUND OR NUMBER
LBS
POUNDS
A
LBS/HR
POUNDS PER HOUR
A/C
AIR CONDITIONING
LD
LINEAR DIFFUSER
ACI
AMERICAN CONCRETE INSTITUTE
LP
LT
LOW POINT
LIGHT
ACP
ASBESTOS CEMENT PIPE
ACS--
ASPHALTIC CONCRETE SURFACE COURSE
ACU
AIR CONDITIONING UNIT
ACT
ACOUSTICAL CEILING TILE
MATL
MATERIAL
AD
AREA DRAIN
AIE
ADJUSTABLE
MC
MEDICINE CABINET
A/E
ARCHITECT/ENGINEER j
MEC4
MECHANICAL
AF
ACCESS FLOORING
MEM
MEMBRANE
AG
ABOVE FINISHED FLOOR j
MFR
MANUFACTURER
AH
AGGREGATE
MM
MINIMUM
AI U
AIR HANDLING UNIT
MISC
MISCELANEOUS
ALT
ALTERNATE
MO
MASONRY OPENING
AL
ALUMINUM
MTD
MOUNTED
ANN
ANNUNCIATOR
MTL
METAL
ANSI
AMERICAN NATIONAL STANDARDS INSTITUTE
MUL
MULLION
ANT
ANTENNA
MULT
MULTIPLE
AP
ACCESS PANEL
N
APL
ACCESS PLENUM
APROX
APPROXIMATE
ARCH
ARCHITECTURAL
N
NORTH
ASS
ASBESTOS
NEC
AL ELT IC CODE
ASPH
A
ECT
M
ASTM
AMERICAN SOCIETY OF TESTING t MATERIALS
NUMBER
ROM
NOMNAL
NFL
NAME PLATE
BAT
BATTERY
NTS
NOT TO SCALE
BD
BOARD
o
BITUM
BITUMINOUS
BLDG
BUILDING
BLKG
BLOCKING
OA
OVERALL
BM
BEAM
OBS
OBSCURE
BOT
BOTTOM
6
OD
OUTSIDE DIAMETER DIM)
OFS
OVERFLOW SCUPPER
CAB
CABINET
Opp
OPPOSITE
CB
CATCH BASN
CEM
CEMENT
CER
CERAMIC
CFM
CUBIC FEET PER MINUTE
CG
CO RNER GUARD
PC
PRECAST CONCRETE
CHP
CRICKET HIGH PONT
Pi
PIPE JOINT
CI
CAST IRON
PL
PLASTIC
C
CAST IRON COVER
P LAM
PLASTIC LAMINATE
CIP
CAST IRON PIPE
PLAS
PLASTER
CJ
CONTROL JOINT
PLYWO
PLYWOOD
CLG
CEILING
PNT
PAINT
CLGD
CEILING DIFFUSER
PT
POINT OR PATIENT
CLKts
CAULKING
PTO
PAPER TOWEL DISPENCER
CLO
CLOSET
PTN
PM
PARTITION
PAPER TOWEL RECEPTACLE
CLP
CRICKET LOW POINT
CLR
CLOSER
CMP
CORRUGATED METAL PIPE
CMU
CONCRETE MASONRY UNIT
CNTR
COUNTER
ORT
QUARTER
CO
CLEAN OUT
QT
QUARRY TILE
COL
COLUMN
C0MM
COMMUNICATION
CONC
CONCRETE
jz
CONN
CONNECTION
CONSTS
CONSTRUCTION
R
REAR
CONT
CPT
CONTINUOUS
CARPET TILE
RA
RAD
RETURN AIR
RADIUS
CT
CERAMIC TILE
RB
REINFORCED BEAM
CTR
CENTER
RCPT
RECEPTION
CTSK
COUNTERSUNK
RD
ROOF DRAIN
®
REF
REFERENCE
REINF
REINFORCED
REQ
REQUIRED
DBL
DOUBLE
RESL
RESILIENT
DEG
DEGREE
RGTR
REGISTER
DEPT
DEPARTMENT
ROUGH
ROOM
DESIG
DESIGNATION
R
OPENING
DET
DETAIL
RWL
RAM WATER LEADER
OF
DRINKING FOUNTAIN
DG
DOOR GRILLE
DIA
DIAMETER
DIAL
DIAGRAM
DIM
DIMENSION
DISR
DISPENSER
S
STUCCO
DN
DOW!
SC
SCREED CONCRETE
DO
DOOR OPENING
SCI-ED
SCHEDULE
DsP
DRY STANDPIPE
SEC
SECOND
DS
l
DOWN SPOUT
SD
SMOKE DETECTOR
DWGS
DRAWINGS_ _ --
SECT
SECTION
DWR
DRAWER - ! --
SF
SUPPLY FAN
SG
SPANDREL GLASS
SGR
SYNTHETIC GRADE
SHR
SHOWER
EA
EACH
SHT
SHEET
EG
EPDXY COATING
SIG
SIGNAL
EHD
ELECTRIC HAND DRYER
SIM
SK
SIMILAR
SINK
EL
EJ
ELEVATION
EXPANSION JOINT
SM
� METAL
ELEG
ELECTRICAL
SND
SMOKE
SOUND
ELEV
ELEVATOR
SPEC
SPECIFICATION
EMER
EMERGENCY
SPKR
SPEAKERS
ENCL
ENCLOSURE
SQ
SQUARE
ENGR
ENGINEER
SQFT
SQUARE FEET
EPNL
ELECTRICAL PANEL
SST
STAINLESS STEEL
EQ
E
EQUAL
EQUIPMENT
ST
STREET
EST ST
ESTIMATE
STC
SOUND TRANSMISSION COEFFICIENT
ET
EXPANSION TAW,
STD
STANDARD
EWC
ELECTRIC WATER COOLER
ST -D
STL
STORM DRAIN
STEEL
EXIN
EXHAUST
STRL
STRUCTURAL
EXST
EXISTING
SUSP
SUSPENDED
EXT
EXTERIOR
SYM
SYMMETRICAL
SYS
SYSTEM
p
T
FA
FIRE ALARM
FABI.
FIRE ALARM BELL
FD
FLOOR DRAIN
t
TOILET
FG
FIBERGLASS
TS
TIE BEAM
FCO
FLOOR CLEANOUT
TC
TIE COLUMN
FD
FIRE DAMPER
TEL
TELEPHONE
FDC
FIIE DEPARTMENT CONNECTOR
TEMP
TEMPERATURE
FOR
FIRE DOOR
TtG
TONGUE AND GROVE
FDN
FOUNDATIONS
THK
THICK
FDV
FIRE DEPARTMENT VALVE
TOC
TOPP
TOP OF CURB
TOP OF PARAPET
FEG
FIR= EXTINGUISHER CABINET
TOS
TOP OF SLAB
FEX
FIRE EXTINGUISHER
TP
TOP OF PAVEMENT
FF
FNISH FLOOR
TRD
TREAD
PH
FIRE HYDRANT
TS
TUBULAR STEEL
FIN
FINISH
TSTAT
THERMOSTAT
FL
FLOOR
TV
TELEVISION
FM
FACTORY MANUAL
TW
TOP OF WALL
FLASH
FLASHING
TYP
TYPICAL
FLG
FLANGE
FLOUR
FLUORESCENT
u
FOC
FACE OF CONCRETE
FOP
FACE OF FINISH
us
UNDERCUT
FOM
PACE OF MASONRY
UL
UNDERWRITER'S LABORATORIES
FOS
FACE OF STUD
UNF
UNFINISHED
FPR'
FIREPROOF
UON
UNLESS OTHERWISE NOTED
FPM
FEET PER MINUTE
UOS
UNLESS OTHER SPECIFIED
FRD
FRENCH DRAIN
UR
URINAL
FS
FULL SIZE
UTIL
UTILITY
FT
FOOT OR FEET
FTG
FOOTING
Y
FT -LB
FOOT POUNDS
FURR
FURRING
VB
VINYL BASE
FUT
FUTURE
VCT
VINYL COMPOSITION TILE
VERT
VERTICAL
VEST
VESTIBULE
VF
VERIFY IN FIELD
VOL
VOLUME
GA
GAUGE
VT
VAPOR TIGHT
GAL
GALLON
VTR
VENT THRU ROOF
GALV
GALVANIZED
GB
GRADE BEAM
GEN
GENERATOR
GL
GLASS
UJR
WIRE
CGsLS GLLASSS
BLOCK
W
WINDOW
GR
GRILLE
W/
WITH
GRD
GRADE
WC
WATER CLOSET
GWB
GYPSUM WALL BOARD
WCO
WALL CLEANOUT
GYP
GYPSUM
WD
WOOD
Ir
i,.:j
HB
HG
HOWD
HOWE
WIT
HM
HORIZ
HP
HR
HTR
HVAC
1-IYD
I
ID
IN
NT
7J
JAN
JB
JOT
JSK
JT
KO
HOSE BIB
HANDICAPPED
HARDWOOD
HARDWARE
HEIGHT
HOLLOW METAL
HORIZONTAL
HIGH POINT
HOUR
HEATER
HEATING, VENTILATION, AND AIR CONDITIONING
HYDRANT
NSIDE DIAMETER l DIAM )
INCHES
INTERIOR
JANITOR
JUNCTION BOX
JUNCTION
JANITORS SINK
JOINT
KNOCK OUT
WP
WALL FABRIC
W/O
WITHOUT
WP
WATER PROOF
WSCT
WANBCOT
WT
WEIGHT
uuP
WELDED WIRE FABRIC
WWM
WELDED WIRE MESH
C3� `
_. s • o e'�.e 10
,O,•Q
S i
•mod'
t,