04-07-09 Item 25 PlanAWiliate of Baptist Health a 1,- CONTRACTOR IS BEING PROVIDED WITH COMPLETE SETS OF DOCUMENTS. CONTRACTOR IS RESPONSIBLE FOR PROVIDING SUBCONTRACTORS WITH COMPLETE SETS OF DRAWINGS. INTENT IS FOR ALL SYSTEMS AND EQUIPMENT TO BE PROVIDED WITH UTILITY CONNECTIONS AS REQUIRED FOR OPERATION. EXAMPLE - IF A SINK IS SHOWN IN THE ARCHITECTURAL PLANS, THE PLUMBING PLANS DO NOT SHOW A WATER OR DRAWINGS CONNECTION THE ENGINEER WILL PROVIDE THE DESIGN DETAILS IN ACCORDANCE WITH THE DESIGN CRITERIA FOR THE REST OF THE INSTALLATIONS. CONTRACTOR IS RESPONSIBLE FOR PRO- VIDING THE CONNECTION AT NO ADDITIONAL COST TO THE OW- NER. 2.- CONTRACTOR IS RESPONSIBLE FOR VISITING THE SITE DURING THE BIDDING PERIOD AND VERIFY THAT THE CONDITION ARE AS DESCRIBED IN THE DOCUMENTS. DISCREPANCIES ARE TO BE NOTED IN WRITING, AND NOTIFY ARCHITECT / ENGINEERS. CONTRACTOR ACCEPTS CONDITIONS AS THEY ARE ON THE SITE, AND MUST PROVIDE SYSTEMS AND WORK AS DESCRIBED IN THE CONTRACT DOCUMENTS AT NO ADDITIONAL COST TO THE OWNER. 3.- DIMENSIONS PROVIDED ARE NOMINAL NOT ACTUAL. THEY TAKE AS A BASIS EXISTING WALLS. IF DISCREPANCIES ARE FOUND, NOTIFY ARCHITECT IMMEDIATELY FOR COORDINATION. IF CON- TRACTOR PROCEEDS, HE DOES SO AT HIS OWN RISK AND IS RESPONSIBLE FOR ALL EXPENSES INCURRED IF AT THE DISCRE _ TION OF THE OWNER OR THE ARCHITECT THE WORK HAS TO BE RE -DONE, 4.- SHUTDOWN OF UTILITIES, IF A SHUTDOWN OR ANY TYPE OF INTER- FERENCE WITH EXISTING SYSTEMS IS ANTICIPATED THE CONTRAG TOR MUST NOTIFY THE OWNER 72 HOURS IN ADVANCE AND OBTA- IN APPROVAL IN WRITING PRIOR TO PROCEEDING. 5.- CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS AND USE ALL APPROPRIATE CONSTRUCTION METHODS / TECHNIQUES TO PROTECT EXISTING UTILITIES AND OTHER PROPERTY NOT NOTED FOR REMOVAL. CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES INCURRED DURING CONSTRUCTION AND SHALL REPAIR ANY DAMAGES AT NO EXPENSE TO THE OWNER. 6.- IF THERE IS A DISCREPANCY BETWEEN THE DRAWINGS AND THE SPECIFICATIONS, THE CONTRACTOR IS TO OBTAIN CLARIFICATION DURING THE BIDDING PERIOD. IF THE DISCREPANCY COMES UP DURING THE CONSTRUCTION,IT IS ASSUMED THE CONTRACTOR BID THE MOST EXPENSIVE WAY AND WILL DO THE WORK AS PER THE DIRECTION OF THE OWNER /ARCHITECT AT NO ADDITIONAL COST TO THE OWNER. 7.- ABBREVIATIONS THROUGHOUT THE PLANS ARE THOSE IN COM- MON USE ARCHITECT WILL DEFINE INTENT OF ANY IN QUESTION. 8; THE, CONTRACTOR SHALL PROVIDE ALL NECESSARY TEMPORARY BARRIERS, LIGHTING, COVERINGS, FIRE PREVENTION AND OTHER EQUIPMENT TO PROTECT THE SAFETY OF ALL PFRSONS AND-T14 -2 PG ?OrEFPTY T HROUGHOU r THE ENTIRE PERIOD Or-- THE CONSTRUC _ TION CONTRACT. 9.- THE CONTRACTOR SHALL VERIFY SIZES AND LOCATIONS OF ALL OPENINGS FOR MECHANICAL, ELECTRICAL AND PLUMBING EQUIPMENT WITH SUBCONTRACTORS, AS WELL AS SHOP DRAWINGS AS APPROVED BY ARCHITECT, BEFORE PROCEEDING WITH THE WORK. 10.- ALL ITEMS USED IN CONSTRUCTION, BUT NOT SPECIFICALLY MENTIONED HEREIN, SHALL CONFORM TO ALL LOCAL CODES AND STATE ORDINANCES AS TO APPLICATION AND USE. II.- PROVIDE ELECTRIC INSULATION BETWEEN ALL DISSIMILAR METAL AND ALSO BETWEEN CEMENT AND METAL. 12.- THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL PERMITS TO COMPLETE THE PROJECT. 13: CONTRACTOR TO REVIEW ALL EXISTING BUILDING SYSTEMS AS TO THEIR COMPLIANCE WITH ALL LOCAL AGENCY REQUIREMENTS AND BRING ANY NONCONFORMING ITEMS TO ARCHITECTS AND ENGINEER'S ATTENTION. 14: GENERAL CONTRACTOR IS TO PROTECT EXISTING ADJACENT AREAS TO WHERE WORK IS TO BE PERFORMED. ANY EXISTING MILLWORK, EQUIPMENT DAMAGED DUE TO WORK PERFORMED SHALL BE REPAIRED/ REPLACED TO MATCH EXISTING (TYPICAL UNLESS OTHERWISE NOTED). 15: DRAWINGS ARE SCHEMATIC SHOWING RELATIVE LOCATIONS AND CONNECTIONS AND SHALL NOT BE SCALED AT ANY TIME. 16.- ALL WOOD BLOCKING WITHIN BUILDING STRUCTURE, SHALL BE FIRE - RETARDANT TREATED AS PER SPECIFICATIONS. 17.- GENERAL CONTRACTOR SHALL INSPECT ALL EXISTING RATED WALLS / PARTITIONS WITHIN SCOPE OF WORK AREA. CONTRACTOR SHALL UPGRADE EXISTING PARTITIONS AS REQUIRED TO MAINTAIN THE INTEGRITY OF THE DESIGNATED RATING. 18.- ELEVATION AND LEVELS, A. ALL NUMERICAL ELEVATIONS ARE TO TOP OF CONCRETE SLAB. UNLESS NOTED OTHERWISE. 19.- ALL INTERIOR GYPSUM WALL BOARD IS 5/8' TYPE X G.W.B. ON METAL STUDS OR FURRING CHANNE!LS UNLESS NOTED OTHERWISE. SIZES AS DIMENSIONED ON FLOOR PLANS. SEE NOTES 9 FOR LOCATION OF WATER RESISTANT G.W.B. 20.- PROVIDE WATER RESISTANT TYPE X G.W.B. IN ALL TOILETS. AND JANITOR'S CLOSETS. 21.- BEFORE PATCHING ANY FIRE - RATED C.M.U. PARTITION. FILL ANY EXPOSED CELLS SOLID WITH GROUT. 22,- PROVIDE FINISH WALL UNDER AND BEHIND ALL EQUIPMENT AND CASEWORK 23.- LOCATION AND SIZE OF CEILING AND WALL ACCESS PANELS SHALL BE DETERMINED BY THE POSITION OF VALVES AND OTHER MECHANICAL AND ELECTRICAL ITEMS WHICH REQUIRE ACCESS. THE CONTRACTOR SHALL COORDINATE WITH ALL TRADES. THE ARCHITECT SHALL REVIEW AND APPROVE ALL FINAL LOCATION OF ACCESS PANELS PRIOR TO INSTALLATION. 24.- THERE SHALL BE NO BACK - TO BACK ELECTRICAL TELEPHONE OR OTHER OUTLETS. 25.- ALL VERTICAL PIPING AND COLUMNS, EXPOSED IN ROOMS SHALL BE FURRED WITH METAL STUDS AND DRY WALL AND FINISI -ED TO MATCH ADJACENT WALLS, UNLESS NOTED OTHERWISE, EXCEPTIONS A. ELECTRIC CLOSETS C. MECHANICAL ROOMS B. TELEPHONE CLOSETS D. STAIRS 26: WHERE HVAC OR OTHER MECHANICAL, ELECTRICAL AND PLUMBING ITEMS PENETRATE PARTITIONS, STUDS SHALL BE BRACED AND FRAMED TO STRUCTURE AS REQUIRED TO PROVIDE ADEQUATE SUPPORTS. ALL PENETRATIONS THROUGH RATED WALLS SHALL BE SEALED TO PROVIDE FIRE, SMOKE AND / OR ACOUSTICAL ISOLATION OF SPACES WITH APPROPRIATE FIRE S.T.0 MATERIAL. 27.- SEE INTERIOR ELEVATIONS FOR FINISHES AND FINISH DETAILS FOR INTERIOR SPACES. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR ACOUSTICAL TILE FINISH. 28. SEE ARCHITECTURAL REFLECTED CEILING PLANS FOR LOCATION OF CEILING MOUNTED MECHANICAL, ELECTRICAL FIXTURES. 29. STAGGER JOINTS VERTICALLY AND HORIZONTALLY IN ALL G.W.B. PARTITIONS EA. SIDE OF PARTITION, JOINTS STAGGERED MINIMUM 2' -O". UNLESS OTHERWISE NOTED. 30. CONTRACTOR SHALL CONFIRM THAT ALL EXISTING EXPOSED STEEL COMPLIES WITH N.F.P.A FIRE PROTECTION REQUIRE- MENTS. CONT12ACTOIRSWALL PROVIDE ALL NECESSARY INSULA- TION/FIRE PROTECTIVE COATING$. 31. CONTRACTOR TO SUBMIT ALL SHOP DRAWING TO ARCHITECT AND THE BUILDING DEPARTMENT FOR APPROVAL. (ELEVATOR, TRUSSES, WINDOWS, ETC.) 32. CONTRACTOR REQUIRED TO PULL SEPARATE DEMOLITION PERMIT, of South A TT Y)ON PAIN R L) A %.j J t S AURAN't EB0000924 LOUIS J. AGUIRRE & ASSOCIATES P.A. CONSULTING ENGINEERS 2600 DOUGLAS RD. SUITE 605 CORAL GABLES, FLORIDA 33134 TELEPHONE: (305) 444 -1679 FAX: (305) 448 -1405 E -MAIL ADDRESS: GRALMAIL@LJAAPA.COM INTERIOR REMODELING ONLY FEBRUARY 18, !18 ARCHITECTURAL A -1 DEMOLITION PLAN, LEGEND AND NOTES. A -2 FLOOR PLAN, LEGEND AND NOTES. A -3 REFLECTED CEILING PLAN, LEGEND AND NOTES. A -4 EQUIPMENT PLAN, INTERIOR ELEVATIONS, LEGEND AND NOTES. A -5 DOOR SCHEDULE, NOTES AND DETAILS. A -6 FINISH SCHEDULE, DETAILS, NOTES AND PARTITION TYPES. A -7 PENETRATIONS AND FIRE RATING DETAILS. A -8 PENETRATIONS AND FIRE RATING DETAILS. A -9 PENETRATIONS AND FIRE RATING DETAILS. m 01114 *0 f4l Of 0 T_!' MO.00 SYMBOLS LEGEND, AND GENERAL NOTES - HVAC. M3.00 DEMOLITION FLOOR PLAN - HVAC. M3.01 DEMOLITION FLOOR PLAN - CHILLED WATER PIPING - HVAC. M3.02 FLOOR PLAN - HVAC. M3.03 FLOOR PLAN - CHILLED WATER PIPING - HVAC. M7.00 DETAIM - RVAC. PLUMBING PO.00 SYMBOLS LEGEND, AND GENERAL NOTES. P3.00 FLOOR PLAN AND PARTIAL DEMOLITION FLOOR PLAN. P5.00 DOMESTIC WATER AND SANITARY ISOMETRIC RISER DIAGRAM. P7.00 DETAILS. ILI ORIGINAL BUILDING DESCRIPTION EO.00 SYMBOLS LEGEND, GENERAL NOTES AND LIGHTING FIXTURE SCHEDULE. E3.00 DEMOLITION FLOOR PLAN LIGHTING. E3.01 DEMOLITION FLOOR PLAN POPPER. E3.02 FLOOR PLAN - LIGHTING. E3.03 FLOOR PLAN - SYSTEMS. E5.00 RISER DIAGRAM. E6.00 PANEL BOARD SCHEDULES. FIRE PROTECTION FPO.00 SYMBOLS, LEGEND AND GENERAL NOTES. FP3.00 FLOOR PLAN. BUILDING JURISDICTION : SOUTH MIA , MIAMI DADE COUNTY PRIMARY USE CLASS : GROUP "S" SPECIAL STORAGE OCCUPANCY NUMBER OF STORIES : 9 LEVELS (OPEN AUTOMOBILE PARKING GARAGE) NEW PROJECT DESCRIPTION PROJECT AREA: : TOTAL: 2,006 S.F. SPRINKLED FULLY SPRINKLERED FLORIDA BUILDING CODE 2004 EDITION FLORIDA FIRE PREVENTION CODE 2004 EDITION NEW LAI, j •,' tall' CMITEC 1 LOkAL Y A 1 I : WVIW-,, isRfR UMme t AND WITHOUT WP WATER PROOF L ANGLE L WT • AT uuP L LENGTH G CENTERING LAM LAMINATE O DIAMETER LAV LAVATORY • POUND OR NUMBER LBS POUNDS A LBS/HR POUNDS PER HOUR A/C AIR CONDITIONING LD LINEAR DIFFUSER ACI AMERICAN CONCRETE INSTITUTE LP LT LOW POINT LIGHT ACP ASBESTOS CEMENT PIPE ACS-- ASPHALTIC CONCRETE SURFACE COURSE ACU AIR CONDITIONING UNIT ACT ACOUSTICAL CEILING TILE MATL MATERIAL AD AREA DRAIN AIE ADJUSTABLE MC MEDICINE CABINET A/E ARCHITECT/ENGINEER j MEC4 MECHANICAL AF ACCESS FLOORING MEM MEMBRANE AG ABOVE FINISHED FLOOR j MFR MANUFACTURER AH AGGREGATE MM MINIMUM AI U AIR HANDLING UNIT MISC MISCELANEOUS ALT ALTERNATE MO MASONRY OPENING AL ALUMINUM MTD MOUNTED ANN ANNUNCIATOR MTL METAL ANSI AMERICAN NATIONAL STANDARDS INSTITUTE MUL MULLION ANT ANTENNA MULT MULTIPLE AP ACCESS PANEL N APL ACCESS PLENUM APROX APPROXIMATE ARCH ARCHITECTURAL N NORTH ASS ASBESTOS NEC AL ELT IC CODE ASPH A ECT M ASTM AMERICAN SOCIETY OF TESTING t MATERIALS NUMBER ROM NOMNAL NFL NAME PLATE BAT BATTERY NTS NOT TO SCALE BD BOARD o BITUM BITUMINOUS BLDG BUILDING BLKG BLOCKING OA OVERALL BM BEAM OBS OBSCURE BOT BOTTOM 6 OD OUTSIDE DIAMETER DIM) OFS OVERFLOW SCUPPER CAB CABINET Opp OPPOSITE CB CATCH BASN CEM CEMENT CER CERAMIC CFM CUBIC FEET PER MINUTE CG CO RNER GUARD PC PRECAST CONCRETE CHP CRICKET HIGH PONT Pi PIPE JOINT CI CAST IRON PL PLASTIC C CAST IRON COVER P LAM PLASTIC LAMINATE CIP CAST IRON PIPE PLAS PLASTER CJ CONTROL JOINT PLYWO PLYWOOD CLG CEILING PNT PAINT CLGD CEILING DIFFUSER PT POINT OR PATIENT CLKts CAULKING PTO PAPER TOWEL DISPENCER CLO CLOSET PTN PM PARTITION PAPER TOWEL RECEPTACLE CLP CRICKET LOW POINT CLR CLOSER CMP CORRUGATED METAL PIPE CMU CONCRETE MASONRY UNIT CNTR COUNTER ORT QUARTER CO CLEAN OUT QT QUARRY TILE COL COLUMN C0MM COMMUNICATION CONC CONCRETE jz CONN CONNECTION CONSTS CONSTRUCTION R REAR CONT CPT CONTINUOUS CARPET TILE RA RAD RETURN AIR RADIUS CT CERAMIC TILE RB REINFORCED BEAM CTR CENTER RCPT RECEPTION CTSK COUNTERSUNK RD ROOF DRAIN ® REF REFERENCE REINF REINFORCED REQ REQUIRED DBL DOUBLE RESL RESILIENT DEG DEGREE RGTR REGISTER DEPT DEPARTMENT ROUGH ROOM DESIG DESIGNATION R OPENING DET DETAIL RWL RAM WATER LEADER OF DRINKING FOUNTAIN DG DOOR GRILLE DIA DIAMETER DIAL DIAGRAM DIM DIMENSION DISR DISPENSER S STUCCO DN DOW! SC SCREED CONCRETE DO DOOR OPENING SCI-ED SCHEDULE DsP DRY STANDPIPE SEC SECOND DS l DOWN SPOUT SD SMOKE DETECTOR DWGS DRAWINGS_ _ -- SECT SECTION DWR DRAWER - ! -- SF SUPPLY FAN SG SPANDREL GLASS SGR SYNTHETIC GRADE SHR SHOWER EA EACH SHT SHEET EG EPDXY COATING SIG SIGNAL EHD ELECTRIC HAND DRYER SIM SK SIMILAR SINK EL EJ ELEVATION EXPANSION JOINT SM � METAL ELEG ELECTRICAL SND SMOKE SOUND ELEV ELEVATOR SPEC SPECIFICATION EMER EMERGENCY SPKR SPEAKERS ENCL ENCLOSURE SQ SQUARE ENGR ENGINEER SQFT SQUARE FEET EPNL ELECTRICAL PANEL SST STAINLESS STEEL EQ E EQUAL EQUIPMENT ST STREET EST ST ESTIMATE STC SOUND TRANSMISSION COEFFICIENT ET EXPANSION TAW, STD STANDARD EWC ELECTRIC WATER COOLER ST -D STL STORM DRAIN STEEL EXIN EXHAUST STRL STRUCTURAL EXST EXISTING SUSP SUSPENDED EXT EXTERIOR SYM SYMMETRICAL SYS SYSTEM p T FA FIRE ALARM FABI. FIRE ALARM BELL FD FLOOR DRAIN t TOILET FG FIBERGLASS TS TIE BEAM FCO FLOOR CLEANOUT TC TIE COLUMN FD FIRE DAMPER TEL TELEPHONE FDC FIIE DEPARTMENT CONNECTOR TEMP TEMPERATURE FOR FIRE DOOR TtG TONGUE AND GROVE FDN FOUNDATIONS THK THICK FDV FIRE DEPARTMENT VALVE TOC TOPP TOP OF CURB TOP OF PARAPET FEG FIR= EXTINGUISHER CABINET TOS TOP OF SLAB FEX FIRE EXTINGUISHER TP TOP OF PAVEMENT FF FNISH FLOOR TRD TREAD PH FIRE HYDRANT TS TUBULAR STEEL FIN FINISH TSTAT THERMOSTAT FL FLOOR TV TELEVISION FM FACTORY MANUAL TW TOP OF WALL FLASH FLASHING TYP TYPICAL FLG FLANGE FLOUR FLUORESCENT u FOC FACE OF CONCRETE FOP FACE OF FINISH us UNDERCUT FOM PACE OF MASONRY UL UNDERWRITER'S LABORATORIES FOS FACE OF STUD UNF UNFINISHED FPR' FIREPROOF UON UNLESS OTHERWISE NOTED FPM FEET PER MINUTE UOS UNLESS OTHER SPECIFIED FRD FRENCH DRAIN UR URINAL FS FULL SIZE UTIL UTILITY FT FOOT OR FEET FTG FOOTING Y FT -LB FOOT POUNDS FURR FURRING VB VINYL BASE FUT FUTURE VCT VINYL COMPOSITION TILE VERT VERTICAL VEST VESTIBULE VF VERIFY IN FIELD VOL VOLUME GA GAUGE VT VAPOR TIGHT GAL GALLON VTR VENT THRU ROOF GALV GALVANIZED GB GRADE BEAM GEN GENERATOR GL GLASS UJR WIRE CGsLS GLLASSS BLOCK W WINDOW GR GRILLE W/ WITH GRD GRADE WC WATER CLOSET GWB GYPSUM WALL BOARD WCO WALL CLEANOUT GYP GYPSUM WD WOOD Ir i,.:j HB HG HOWD HOWE WIT HM HORIZ HP HR HTR HVAC 1-IYD I ID IN NT 7J JAN JB JOT JSK JT KO HOSE BIB HANDICAPPED HARDWOOD HARDWARE HEIGHT HOLLOW METAL HORIZONTAL HIGH POINT HOUR HEATER HEATING, VENTILATION, AND AIR CONDITIONING HYDRANT NSIDE DIAMETER l DIAM ) INCHES INTERIOR JANITOR JUNCTION BOX JUNCTION JANITORS SINK JOINT KNOCK OUT WP WALL FABRIC W/O WITHOUT WP WATER PROOF WSCT WANBCOT WT WEIGHT uuP WELDED WIRE FABRIC WWM WELDED WIRE MESH C3� ` _. s • o e'�.e 10 ,O,•Q S i •mod' t,