11-629-025(D (D 0 0 MANUFACTURER: BY CONTRACTOR » » MAINS: 200A AIC: 10 K MOUNTING: RECESSED PANEL — A BUS RATING: 225 AMP LOCATION: REFER TO FLOOR PLANS VOLTAGE: 120/240 1-PH 3W CKT. NO. POLE/ TRIP KVA DESCRIPTION WIRING & CONDUIT CKT. NO. POLE/ TRIP KVA DESCRIPTION WIRING & CONDUIT 2/35 * C.0 3#8,1#IOG 2 2/50 * A.H.U. 2#6,1#10G 3 2/70 * INSTANT WATER HEATER 3#4,1#8G 6 2/50 * DOUBLE OVEN 3#6,1#10G 5 2/20 * SPARE 12 2/30 * CLOTH DRYER 3#10,1#10G 9 13 1/20 * SMALL APPLIANCES 2#12,1#12G 14 1/20 * CLOTH WASHER 2#12,1#12G 15 1/20 * SMALL APPLIANCES 2#12,1#120 16 1/20 * REFRIGERATOR 2#12,1#12G 17 1/20 * LOUNDRY RECEPTACLE 2#12,1#12G 18 1/20 * DISHWASHER 2#12,1#12G 19 1/20 * MICROWAVE 2#12,1#12G 20 1/20 * GARBAGE DISPOSAL 2#12,1#12G 21 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 22 1/20 * GAS COOKTOP IGNATOR/EXHAUST 2#12,1#12G 23 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 24 1/20 * BATHROOM GFI RECEPTACLE 2#12,1#12G 25 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 26 1/20 * BATHROOM GFl RECEPTACLE 2#12,1#12G 27 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 28 1/20 * CARPORT GA RECEPTACLE 2#12,1#120 29 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 30 1/20 * UGHT. CARPORT/LOUNDRY 2#12,1#12G 31 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 32 1/20 * LIGHTING - EXTERIOR 2#12,1#12G 33 1/20 * SMOKE ALARM DETECTOR 2#12,1#12G 34 1/20 * RECEPTACLE - GFI EXTERIOR 2#12,1#12G 35 1/20 * RECEPTACLES - DINING 2#12,1#12G 36 1/20 * LIGHTING AND RECEPTACLES 2#12,1#12G 37 1/20 * LIGHT. & RECEP. FAMILY 2#12,1#12G 38 1/- * SPARE - 39 1/20 * LIGHT. & RECEP. KITCHEN/DINING 2#12,1#12G 40 1/- * SPARE - 41 1/- * SPARE - 42 1/- * SPARE - TOTAL * TOTAL TOTAL CONNECTED LOAD (DPROVIDE ARC FAULT CIRCUIT INTERRUPTING BREAKER FOR ALL BED ROOM OUTLETS' CIRCUITS. * REFER TO LOAD CALCULATION. SMOKE DETECTOR D KITCHEN OR LINE SIDE 120V BATHROOM LIGHT OF SWITCH SWITCH SWITCH LEG PHASE CONDUCTOR SMOKE DETECTOR CONNECTION DETAIL NTS. (D NOTES: 1-SMOKE DETECTOR SHALL BE HARDWIRED (120 VOLT TYPE) TO A NON-SWITCHABLE KITCHEN OR BATHROOM UGHTING CIRCUIT OR A DEDICATED CIRCUIT WITH BATTERY BACK-UP AND SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH UNIT SHALL BE INTERCONNECTED 2-SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3FT. OF ANY A/C GRILL. 3-SMOKE DETECTORS LOCATED OUTSIDE OF SLEEPING AREAS SHALL NOT BE PLACED CLOSER THAN 3FT. TO BATHROOM DOOR. 4-THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS SHAI I CnMPI Y WIT14 NFPA 79 SFC 9-5 9.1 _R nR I ATFRT APF NOTE: GROUND SYSTEM PER N.E.0 2 COOL WATER PIPE (METAL) BURIED 10 FT LONG MINIMMUN BLDG. STEEL FOUNDATION Residential Standard Calculation 9/25/1997 CALLEJAS RESIDENCE PANEL A Version 7.28 If Press F1 for Help STEP 1 Article 220.42 & 220.52 0 sq. ft 2120 11 General Lighting load 6,360 VA 0 2 Small Appliance 3,000 VAS 0 1 Laundry circuit 1,500 VA 0 Gen.Lgt„Sm App.& Laun. Load 10,860 VA 5/22/2010 13:39 3,000 VA @ 100%= 3,000 VAS 7,860 VA @ 35% = 2,751 VAS VA @ 25% = VAS General Lighting Demand Load STEP 2 Article 220.50 & 220.51 3.5ton 5,800 VA AHU 1 7.5kW v1j 8,300 VA Total Heat Load 8,300 VA A/C #2 VA AHU 2 Select VA Total CU Loath 5,800 VA A/C #3 VA AHU 3 Select VA Greater of Heat @ 100% vs.A/C @ 100% A/C #4 VA AHU 4 E�1_ VA A/C #5 VA AHU 5-11 VA STEP 3 ' Article 220.53 5,751 VA 8,300 VA Applliance Demand Load 12,615 VA 11,800v 1 Water Heater 11,800 VA 1,400VA 1 Refrigerator 1,400 VA Drryer Demand Load 5,000 VA Freezer VA 1,030 VA 1 Dishwasher 1,030 VA Ra nge Demand Load VA 690 VA 1 Disposal 690 VA .� Trash Compactor VA Service Demand 31,666 VA 1,500VA 1Microwave 1,500VA Central Vac VA Demand Load 132 A Mini Refrigerator VA F, 400 VA 1 Range hood 400 VA Neutral Demand 53 A F- . Wine Cooler VA Ironing Center VA Min.Service Req. 150 A F_ select Jacuzzi Tub VA r select Sprinkler Pump VA Min. Feeder size 1 r select Well Pump VA Min. Neutral size 6 select �) Fountain Pump ' VAS Eq. Grding Cond. 6 select �) Elevator VA (- Copper Pool Equip. Panel ' VAS 100% Demand r VA No Demand F_ r VA No Demand Total Appliance Load 16,820 VAS 4 or more demand @ 75% plus 100% demand loads 12,615 VAS STEP 4 %rticle 220.54 Electric Clothes Dryers 5,000 VA STEP 5 lArticle 220.55 Electric Ranges Col C demand W� Number of appliances Cooktop Col B demand 1`7 Check Box for Gas Range Cooktop Col B demand Oven(s) Col B demand Oven(s) Col B demand Number of appliances Dem. Factor 0% Cooktop & Oven Demand Load W IN 2 1/2" CONDUIT TO UTILITY POINT OF SERVICE ELECTRICAL RISER DIAGRAM NTS 401E ELECTRICAL SIMBOLS & LEGEND: $D SPST WALL SWITCH, W/ DIMMER $ SPST WALL SWITCH $3 DPDT WALL SWITCH (3-WAY) $4 DPDT WALL SWITCH (4-WAY) qp DUPLEX WALL RECEPTACLE/BELLOW COUNTER AT 18" AFF. ® 240V OUTLET [P GND FAULT INTERRUPTER DUPLEX RECEPT, 42" AFF COUNTER MOUNT. WPO WEATHER PROOF GFl DUPLEX RECEPT. DUPLEX WALL RECEPTACLE, \ SWITCHED �N TELEVISION OUTLET Y TELEPHONE OUTLET QJ JUNCTION BOX DBL LAMP INC. FLOOD LIGHT O LIGHT FIXTURE. QINC. WALL BRACKET / SCONCE O INCANDESCENT VAPOR PROOF LIGHT. VP WIRING NON -FUSED DISC. SWITCH OI DISC. SWITCH. POLES AND SIZE PER DRAWINGS ELECTRICAL PANEL a EXHAUST FAN KP SECURITY ALARM KEYPAD SD SMOKE DETECTOR, 120V 0 PUSH BUTTON. CH CHIME. ELECTRICAL NOTES 1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES. 2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT COMPANY. 3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO. ANSI/EIA/TIA-570 4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM- PLIPNCE AS t3T FORTH BY STATE OF FLORIDA STATUTES MODEL ENERGY EFFICIENCY CODES. 5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR HIMEELr''' {PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS. 6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION, AS REQUIRED. 7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI- NEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE OWNER, 8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION, UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR ABUTTING WORK TO BE PERFORMED BY OTHERS. 9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC- TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM, UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO- DUCT OF A SINGLE MANUFACTURER. 10. ALL CONDUCTORS SHALL BE COPPER ROMEX AND IT MIGHT BE RUN IN CONDUIT. WIRE TYPE SHALL BE THWN UNLESS OTHERWISE NOTED ON PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250-122. 11. SPECIAL EQUITMENT LOCATIONS OF OULETS IN ELECTRICAL DRAWINGS ARE DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT LOCATION OF OUTLETS. 12. PROVIDE TYPEWRITTEN SCHEDULES FOR PANELBOARDS. 13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON RA EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON- TR ACTOR RACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS, AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE. CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA COST. PICR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE NON U W%NEC SWITCH 6FOR A/C COND. DISCONNECT. (CO14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME CKT (KITCHEN OR BATH LTG.) OR IN A DEDICATED CIRCUIT. 15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL & GROUNDING WIRE PER NEC ARTICLE 250-140. 16. ALL BEDROOMS OUTLETS TO BE PROTECTED BY AN ARC -FAULT INTERRUPTER.(AFCI) 17. LIGHTS TO BE SELECTED BY ARCHITECT AND INSTALLED BY CONTRACTOR. LIGHTS SHALL NOT BE GRATER THAN 100 WATTS. i In `n\�ccc • c� W Pa � 'C: t V v.,, 4 00 o .w" Q U� w Cl7 In LL_. O t0) 0 Ll_ Ln W Z OA OVA .: t jb LL1 O •..,: ,: 0 E o 4 j '1 ;I O I— z W Ld U o Z w LLJ Of C) O L1J LU ry U d- > O (� elfn r w 21-1 Ld Q \ = to o cn z L-i __j `� _:i: i I O to co Q QU((18� DRAWN MS CHECKED JLF DATE 1-10-09 SCALE *'Z7 AS NOTED JOB NO. j 2008- SHEET INDEX , a SCHEDULES_-* SHEET NUMBER E=3,,l