11-629-025(D
(D
0
0
MANUFACTURER: BY CONTRACTOR » » MAINS: 200A AIC: 10 K
MOUNTING: RECESSED PANEL — A BUS RATING: 225 AMP
LOCATION: REFER TO FLOOR PLANS VOLTAGE: 120/240 1-PH 3W
CKT.
NO.
POLE/
TRIP
KVA
DESCRIPTION
WIRING &
CONDUIT
CKT.
NO.
POLE/
TRIP
KVA
DESCRIPTION
WIRING &
CONDUIT
2/35
*
C.0
3#8,1#IOG
2
2/50
*
A.H.U.
2#6,1#10G
3
2/70
*
INSTANT WATER HEATER
3#4,1#8G
6
2/50
*
DOUBLE OVEN
3#6,1#10G
5
2/20
*
SPARE
12
2/30
*
CLOTH DRYER
3#10,1#10G
9
13
1/20
*
SMALL APPLIANCES
2#12,1#12G
14
1/20
*
CLOTH WASHER
2#12,1#12G
15
1/20
*
SMALL APPLIANCES
2#12,1#120
16
1/20
*
REFRIGERATOR
2#12,1#12G
17
1/20
*
LOUNDRY RECEPTACLE
2#12,1#12G
18
1/20
*
DISHWASHER
2#12,1#12G
19
1/20
*
MICROWAVE
2#12,1#12G
20
1/20
*
GARBAGE DISPOSAL
2#12,1#12G
21
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
22
1/20
*
GAS COOKTOP IGNATOR/EXHAUST
2#12,1#12G
23
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
24
1/20
*
BATHROOM GFI RECEPTACLE
2#12,1#12G
25
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
26
1/20
*
BATHROOM GFl RECEPTACLE
2#12,1#12G
27
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
28
1/20
*
CARPORT GA RECEPTACLE
2#12,1#120
29
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
30
1/20
*
UGHT. CARPORT/LOUNDRY
2#12,1#12G
31
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
32
1/20
*
LIGHTING - EXTERIOR
2#12,1#12G
33
1/20
*
SMOKE ALARM DETECTOR
2#12,1#12G
34
1/20
*
RECEPTACLE - GFI EXTERIOR
2#12,1#12G
35
1/20
*
RECEPTACLES - DINING
2#12,1#12G
36
1/20
*
LIGHTING AND RECEPTACLES
2#12,1#12G
37
1/20
*
LIGHT. & RECEP. FAMILY
2#12,1#12G
38
1/-
*
SPARE
-
39
1/20
*
LIGHT. & RECEP. KITCHEN/DINING
2#12,1#12G
40
1/-
*
SPARE
-
41
1/-
*
SPARE
-
42
1/-
*
SPARE
-
TOTAL * TOTAL
TOTAL CONNECTED LOAD
(DPROVIDE ARC FAULT CIRCUIT INTERRUPTING BREAKER FOR ALL BED ROOM OUTLETS' CIRCUITS.
* REFER TO LOAD CALCULATION.
SMOKE DETECTOR
D
KITCHEN OR LINE SIDE 120V
BATHROOM LIGHT OF SWITCH
SWITCH
SWITCH LEG
PHASE CONDUCTOR
SMOKE DETECTOR CONNECTION DETAIL
NTS.
(D
NOTES:
1-SMOKE DETECTOR SHALL BE HARDWIRED (120 VOLT TYPE)
TO A NON-SWITCHABLE KITCHEN OR BATHROOM UGHTING
CIRCUIT OR A DEDICATED CIRCUIT WITH BATTERY BACK-UP AND
SHALL NOT BE CONNECTED ONTO THE LOAD SIDE OF GROUND FAULT
CIRCUIT INTERRUPTER. ALL SMOKE DETECTORS WITHIN EACH
UNIT SHALL BE INTERCONNECTED
2-SMOKE DETECTOR SHALL NOT BE PLACED WITHIN 3FT.
OF ANY A/C GRILL.
3-SMOKE DETECTORS LOCATED OUTSIDE OF SLEEPING
AREAS SHALL NOT BE PLACED CLOSER THAN 3FT.
TO BATHROOM DOOR.
4-THE MOUNTING AND LOCATION OF UNIT SMOKE DETECTORS
SHAI I CnMPI Y WIT14 NFPA 79 SFC 9-5 9.1 _R nR I ATFRT
APF
NOTE: GROUND SYSTEM PER N.E.0 2
COOL WATER PIPE (METAL)
BURIED 10 FT LONG MINIMMUN
BLDG. STEEL FOUNDATION
Residential Standard Calculation 9/25/1997 CALLEJAS RESIDENCE PANEL A
Version 7.28 If Press F1 for Help
STEP 1 Article 220.42 & 220.52 0
sq. ft 2120 11 General Lighting load 6,360 VA 0
2 Small Appliance 3,000 VAS 0
1 Laundry circuit 1,500 VA 0
Gen.Lgt„Sm App.& Laun. Load 10,860 VA 5/22/2010 13:39
3,000 VA @ 100%= 3,000 VAS
7,860 VA @ 35% = 2,751 VAS
VA @ 25% = VAS
General Lighting Demand Load
STEP 2 Article 220.50 & 220.51
3.5ton 5,800 VA AHU 1 7.5kW v1j 8,300 VA Total Heat Load 8,300 VA
A/C #2 VA AHU 2 Select VA Total CU Loath 5,800 VA
A/C #3 VA AHU 3 Select VA Greater of Heat @ 100% vs.A/C @ 100%
A/C #4 VA AHU 4 E�1_
VA
A/C #5 VA AHU 5-11 VA
STEP 3 ' Article 220.53
5,751 VA
8,300 VA
Applliance Demand Load 12,615 VA
11,800v
1
Water Heater
11,800 VA
1,400VA
1
Refrigerator
1,400 VA
Drryer Demand Load
5,000 VA
Freezer
VA
1,030 VA
1
Dishwasher
1,030 VA
Ra nge Demand Load
VA
690 VA
1
Disposal
690 VA
.�
Trash Compactor
VA
Service Demand
31,666 VA
1,500VA
1Microwave
1,500VA
Central Vac
VA
Demand Load
132 A
Mini Refrigerator
VA
F,
400 VA
1
Range hood
400 VA
Neutral Demand
53 A
F-
.
Wine Cooler
VA
Ironing Center
VA
Min.Service Req.
150 A
F_
select
Jacuzzi Tub
VA
r
select
Sprinkler Pump
VA
Min. Feeder size
1
r
select
Well Pump
VA
Min. Neutral size
6
select
�) Fountain Pump
'
VAS
Eq. Grding Cond.
6
select
�) Elevator
VA
(-
Copper
Pool Equip. Panel
'
VAS 100% Demand
r
VA No Demand
F_
r
VA No Demand
Total Appliance Load 16,820 VAS
4 or more demand @
75% plus 100% demand loads
12,615 VAS
STEP 4 %rticle 220.54
Electric Clothes Dryers 5,000 VA
STEP 5 lArticle 220.55
Electric Ranges Col C demand W�
Number of appliances
Cooktop Col B demand
1`7 Check Box for Gas Range Cooktop Col B demand
Oven(s) Col B demand
Oven(s) Col B demand
Number of appliances Dem. Factor 0%
Cooktop & Oven Demand Load W
IN 2 1/2" CONDUIT TO UTILITY
POINT OF SERVICE
ELECTRICAL RISER DIAGRAM
NTS
401E
ELECTRICAL SIMBOLS & LEGEND:
$D SPST WALL SWITCH, W/ DIMMER
$ SPST WALL SWITCH
$3 DPDT WALL SWITCH (3-WAY)
$4 DPDT WALL SWITCH (4-WAY)
qp DUPLEX WALL RECEPTACLE/BELLOW COUNTER AT 18" AFF.
® 240V OUTLET
[P GND FAULT INTERRUPTER DUPLEX RECEPT, 42" AFF COUNTER MOUNT.
WPO WEATHER PROOF GFl DUPLEX RECEPT.
DUPLEX WALL RECEPTACLE, \ SWITCHED
�N TELEVISION OUTLET
Y TELEPHONE OUTLET
QJ JUNCTION BOX
DBL LAMP INC. FLOOD LIGHT
O LIGHT FIXTURE.
QINC. WALL BRACKET / SCONCE
O INCANDESCENT VAPOR PROOF LIGHT.
VP
WIRING
NON -FUSED DISC. SWITCH
OI DISC. SWITCH. POLES AND SIZE PER DRAWINGS
ELECTRICAL PANEL
a EXHAUST FAN
KP SECURITY ALARM KEYPAD
SD SMOKE DETECTOR, 120V
0 PUSH BUTTON.
CH CHIME.
ELECTRICAL NOTES
1. ALL ELECTRICAL WORK SHALL BE IN ACCORDANCE WITH THE
NATIONAL ELECTRICAL CODE AND ALL APPLICABLE LOCAL CODES.
2. COORDINATE ELECTRICAL SERVICE W/FLORIDA POWER AND LIGHT
COMPANY.
3. ALL TELEPHONE RELATED EQUIPMENT PER TELEPHONE CO.
ANSI/EIA/TIA-570
4. ELECTRICAL INSTALLATION DESIGN OF THIS PLAN IN IN COM-
PLIPNCE AS t3T FORTH BY STATE OF FLORIDA STATUTES MODEL
ENERGY EFFICIENCY CODES.
5. THE CONTRACTOR WILL EXAMINE THE JOB SITE AND DETERMINE FOR
HIMEELr''' {PRIOR TO SUBMISSION OF BID EXISTING CONDITIONS.
6. ALL ELECTRICAL WORK SHALL BE PERFORMED BY A LICENSED
ELECTRICAL CONTRACTOR. IT WILL BE HIS RESPONSIBILITY TO
SECURE AND PAY FOR ANY PERMITS, CERTICATES OF INSPECTION,
AS REQUIRED.
7. SUBSTITUTE MATERIALS EQUIPMENT OR METHODS SHALL NOT BE
MADE WITHOUT APPROVAL OF THE ENGINEER. IF THE USE OF A
SUBSTITUTE REQUIRES ANY CHANGE IN WORK. THE NECESSARY FOR
SUCH CHANGE WILL BE BROUGHT TO THE ATTENTION OF THE ENGI-
NEER. AND IF APPROVED, SHALL BE MADE AT NO COST TO THE
OWNER,
8. CLEAN UP SUCH TRASH AND DEBRIS GENERATED BY THE WORK AND
LEAVE COMPLETED WORK IN A CLEAN, UNDAMAGED, AND FINISHED
CONDITION READY TO RECEIVE WITHOUT FURTHER PREPARATION,
UNLESS SO SPECIFIED IN OTHER SECTIONS, ANY ADJACENT OR
ABUTTING WORK TO BE PERFORMED BY OTHERS.
9. MATERIALS, APPLIANCES, DEVICES AND EQUIPMENT SHALL MEET
WITH THE REQUIREMENTS OF UNDERWRITERS' LABORATORIES AND
SHALL BE NEW AND THE LATEST STANDARD PRODUCTS OF MANUFAC-
TURERS REGULARLY ENGAGED IN THE PRODUCTION OF THE ITEM,
UNLESS OTHERWISE INDICATED. LIKE ITEMS SHALL BE THE PRO-
DUCT OF A SINGLE MANUFACTURER.
10. ALL CONDUCTORS SHALL BE COPPER ROMEX AND IT MIGHT BE RUN IN
CONDUIT. WIRE TYPE SHALL BE THWN UNLESS OTHERWISE NOTED ON
PLANS. PROVIDE GROUND CONDUCTOR PER NEC ARTICLE 250-122.
11. SPECIAL EQUITMENT LOCATIONS OF OULETS IN ELECTRICAL DRAWINGS
ARE DIAGRAMMATIC: CHECK MANUFACTURER'S DRAWING FOR EXACT
LOCATION OF OUTLETS.
12. PROVIDE TYPEWRITTEN SCHEDULES FOR PANELBOARDS.
13. A/C EQUIPMENT WIRING, BREAKER AND FUSE SIZES ARE BASED ON
RA
EQUIPMENT SPECIFIED ON ORIGINAL CONTRACT DRAWINGS. CON-
TR
ACTOR RACTOR IS RESPONSIBLE FOR PROVIDING ALL WIRING, BREAKER
AND FUSES SIZES IN ACCORDANCE WITH A/C EQUIPMENT NAMEPLATE
REQUIREMENTS IF DIFFERENT FROM THAT SPECIFIED ON DRAWINGS,
AS WELL AS ANY FEEDER CHANGES BEING AFFECTED BY THIS CHANGE.
CONTRACTOR SHALL MAKE ABOVE MENTIONED CHANGES AT NO EXTRA
COST. PICR CIRCUIT BREAKERS MAY BE USED IN PLACE OF FUSES. USE
NON U W%NEC SWITCH 6FOR A/C COND. DISCONNECT.
(CO14. ALL SMOKE DETECTORS TO BE INTERCONNECTED ON SAME
CKT (KITCHEN OR BATH LTG.) OR IN A DEDICATED CIRCUIT.
15. RANGE AND DRYER SHALL HAVE BOTH NEUTRAL & GROUNDING
WIRE PER NEC ARTICLE 250-140.
16. ALL BEDROOMS OUTLETS TO BE PROTECTED BY
AN ARC -FAULT INTERRUPTER.(AFCI)
17. LIGHTS TO BE SELECTED BY ARCHITECT AND INSTALLED BY
CONTRACTOR. LIGHTS SHALL NOT BE GRATER THAN 100 WATTS.
i
In
`n\�ccc • c�
W Pa
� 'C: t V
v.,,
4
00
o
.w"
Q
U�
w Cl7
In
LL_. O
t0)
0
Ll_
Ln
W Z OA
OVA
.: t jb
LL1 O •..,:
,:
0 E o
4
j
'1
;I
O
I—
z
W
Ld
U
o
Z
w
LLJ
Of
C)
O
L1J
LU
ry
U
d-
>
O
(�
elfn
r
w
21-1
Ld
Q
\
=
to
o
cn
z
L-i
__j
`�
_:i:
i
I
O
to
co
Q
QU((18�
DRAWN
MS
CHECKED
JLF
DATE
1-10-09
SCALE *'Z7
AS NOTED
JOB NO. j
2008-
SHEET INDEX ,
a
SCHEDULES_-*
SHEET NUMBER
E=3,,l