11-629-019GENERAL PLUMBING NOTES CONTRACTOR SHALL PROVIDE ALL LABOR, MATERIALS, AND EQUIPMENT FOR PLUMBING PIPING SYSTEMS COMPLETE, CONTROLS, CONTROL WIRING, DOMESTIC WATER SYSTEMS, PLUMBING CONNECTIONS AND ALL FITTINGS, SPECIALTIES, ANCHORING/SUPPORTING OF EQUIPMENT, AUXILIARY MATERIALS AND ACCESSORIES. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO VISIT THE SITE OF THE WORK AND BECOME FAMILIAR WITH ALL AVAILABLE INFORMATION REGARDING THE LOCATION OF EXISTING FACILITIES. FAILURE OF THE CONTRACTOR TO FULLY INFORM HIMSELF OF ALL EXISTING CONDITIONS WILL NOT BE CAUSE FOR OWNER ADDITIONAL COMPENSATION. ALL EQUIPMENT AND MATERIALS USED IN THIS INSTALLATION SHALL BE NEW, OF APPROVED QUALITY AND MANUFACTURE AND, UNLESS OTHERWISE NOTED, SHALL BE STANDARD CATALOG ITEMS OF THE VARIOUS MANUFACTURERS. EACH COMPONENT OF THE WORK SHALL BE COMPLETE, CONNECTED AND CAPABLE OF SATISFACTORY FUNCTIONAL OPERATION. PIPING SYSTEMS SHALL BE COMPLETE WITH PIPE, PIPE FITTINGS, VALVES, STRAINERS, EXPANSION JOINTS, FLEXIBLE PIPE CONNECTIONS, HANGERS, SUPPORTS, ANCHORS, GUIDES, SLEEVES, AND ACCESSORIES REQUIRED TO ENSURE PROPER OPERATION FOR THE PURPOSE INTENDED. PIPING, VALVES AND ACCESSORIES SHALL BE SUITABLE FOR THE SYSTEM PRESSURE, TEMPERATURE AND CIRCULATING LIQUID. FOLLOW REQUIREMENTS OF THE FLORIDA BUILDING CODE 2001, REGULATIONS, ORDINANCES, ETC., OF THE STATE, COUNTY, AND/OR MUNICIPALITY, IN WHICH THE CONSTRUCTION IS LOCATED, AND ANY OTHER ENTITY HAVING JURISDICTION OVER THIS WORK. ALL EQUIPMENT SHALL FIT THE ALLOTTED SPACE AND SHALL LEAVE REASONABLE ACCESS ROOM FOR SERVICING AND REPAIRS. GREATER SPACE AND ROOM REQUIRED BY SUBSTITUTED EQUIPMENT SHALL BE PROVIDED BY THE CONTRACTOR AND AT HIS EXPENSE AND MEETING THE APPROVAL OF THE OWNER. IF THE CONTRACTOR DISCOVERS ANY DISCREPANCIES BETWEEN EQUIPMENT DIMENSIONS AND SPACE ALLOTMENTS THEREFORE; HE SHALL NOTIFY THE OWNER IN WRITING AND SHALL NOT PROCEED WITH THE WORK UNTIL HE HAS RECEIVED WRITTEN INSTRUCTIONS FROM THE OWNER. THE CONTRACTOR SHALL DO NO CUTTING THAT MAY IMPAIR STRENGTH OF BUILDING CONSTRUCTION. NO HOLES, EXCEPT FOR SMALL SCREWS, MAY BE DRILLED IN BEAMS OR OTHER STRUCTURAL MEMBERS WITHOUT OBTAINING PRIOR APPROVAL OF THE COWNER. THE CONTRACTOR SHALL FURNISH ALL ELECTRICAL WORK ASSOCIATED WITH PLUMBING EQUIPMENT, INCLUDING ELECTRICAL CONTROLS, SWITCHES, AND CONTACTORS. ALL ELECTRICAL WORK SHALL CONFORM IN ALL RESPECTS TO THE REQUIREMENTS OF THE CURRENT NATIONAL ELECTRICAL CODE. THE CONTRACTOR SHALL GUARANTEE ALL WORK, MATERIALS, EQUIPMENT, ETC. AGAINST DEFECTS FOR A PERIOD OF ONE YEAR FROM THE DATE OF THE FINAL ACCEPTANCE. IN ADDITION TO THE GUARANTEE, THE CONTRACTOR SHALL PROVIDE THE PERFORMANCE WARRANTIES AS SPECIFIED FOR THE EQUIPMENT IN THE VARIOUS SECTIONS. TESTING: APPLY A WATER PRESSURE TEST TO ALL PARTS OF THE WATER SUPPLY SYSTEMS BEFORE THE PIPING IS CONCEALED AND BEFORE FIXTURES AND EQUIPMENT ARE CONNECTED. USE A HYDROSTATIC PRESSURE OF NOT LESS THAN 125 PSIG APPLIED TO THE SYSTEM FOR A PERIOD OF FOUR HOURS. THERE SHALL BE NO LEAKS AT ANY POINT IN THE SYSTEM AT THIS PRESSURE. LEAVE CONCEALED WORK UNCOVERED UNTIL REQUIRED TESTS HAVE BEEN COMPLETED, BUT IF NECESSARY TO MAKE TESTS ON PORTIONS OF THE WORK, THOSE PORTIONS OF THE WORK MAY BE CONCEALED AFTER BEING INSPECTED AND APPROVED. REPAIR DEFECTS THAT ARE DISCOVERED AS A RESULT OF INSPECTIONS OR TESTS WITH NEW MATERIALS. CAULKING, PEENING OR SOLDERING OF SCREWED JOINTS, CRACKS, OR HOLES WILL NOT BE ACCEPTED. REPEAT TESTS AFTER DEFECTS HAVE BEEN CORRECTED. CLEANING/STERILIZATION: AS SOON AS THE WATER PIPING HAS BEEN THOROUGHLY FLUSHED OUT, STERILIZE THE LINES BY INTRODUCING INTO THEM A SOLUTION OF CALCIUM HYPOCHLORITE OR CHLORIDE OF LIME. OPEN AND CLOSE ALL VALVES WHILE SYSTEM IS BEING CHLORINATED. AFTER THE STERILIZING AGENT HAS BEEN APPLIED FOR 24 HOURS, TEST FOR RESIDUAL CHLORINE AT THE ENDS OF THE LINES. REPEAT THE PROCESS IF LESS THAN 10 PARTS PER MILLION IS INDICATED. WHEN THE TESTS SHOW AT LEAST 10 PARTS PER MILLION OF RESIDUAL CHLORINE, FLUSH OUT THE SYSTEM UNTIL ALL TRACES OF THE CHEMICAL USED ARE REMOVED. MAKE NECESSARY CONNECTIONS TO STERILIZE PIPING. EQUIPMENT/ MATERIALS NOTES SANITARY AND VENT PIPING MATERIAL: PVC SCHEDULE 40 WITH DWV FITTINGS. DOMESTIC WATER PIPING, CONDENSATE DRAIN AND PRESSURE & TEMP. RELIEF. PIPE MATERIAL : COPPER TUBE TYPE PIPING FOR COLD, HOT AND P&T WATER PIPING. TYPE K BELOW GRADE, L ABOVE GROUND. FOR CONDENSATE DRAIN ROUTING AND REQUIREMENTS SEE MECHANICAL PLANS. PROVIDE FULL PIPING INSULATION ON ALL HOT WATER PIPING, AND EXPOSED PIPING REGARDLESS OF SERVICE. PIPE FITTINGS: WROUGHT COPPER: ELBOWS, TEES, REDUCERS, COUPLINGS, ETC., SOLDER ENDS 150 PSIG WSP, CONFORMING TO ANSI B16.22. FITTINGS MANUFACTURED BY MUELLER BRASS CO., CHASE BRASS, AND COPPER CO. USE 95-5 SOLDER FOR WATER SERVICE AND 50-50 FOR WASTE SERVICE. DO NOT USE SOLDER CONTAINING LEAD FOR POTABLE WATER SERVICE. BRONZE UNIONS FOR 2 1/2" PIPE AND SMALLER. DIELECTRIC UNIONS: DISSIMILAR PIPE METALS SHALL BE ELECTRICALLY INSULATED FROM EACH OTHER BY COUPLINGS, UNIONS, OR FLANGES COMMERCIALLY MANUFACTURED FOR THAT PURPOSE AND RATED FOR THE SERVICE PRESSURE AND TEMPERATURE. USE OF STEEL OR CAST—IRON FITTINGS IN A COPPER PIPING SYSTEM IS PROHIBITED. THREADED UNIONS SHALL BE AS MANUFACTURED BY EPCO. ESCUTCHEONS: PROVIDE STAINLESS STEEL ESCUTCHEONS SECURELY IN PLACE ON EXPOSED PIPES WHERE THEY PASS THROUGH WALLS, PARTITIONS FLOORS AND CEILINGS OR FINISHED AREAS. AIR CHAMBERS: PROVIDE AIR CHAMBERS AT EACH FIXTURE, RISER AND END OF SUPPLY LINES. AIR CHAMBER SHALL NOT BE LESS THAN 18 INCHES LONG AND ONE SIZE LARGER THAN SUPPLY TO FIXTURE BUT NOT LESS THAN 3/4—INCH DIAMETER. PIPE SLEEVES: PROVIDE GALVANIZED SHEET METAL, 22 GAUGE SLEEVES FOR PIPES PASSING THROUGH WALLS OR FLOORS BEFORE POURING CONCRETE. PLASTIC SLEEVES AS MANUFACTURED BY PRESET OR EQUAL ARE PERMITTED. ALL SLEEVES SHALL BE LARGE ENOUGH TO ALLOW FULL THICKNESS OF INSULATION THROUGH SLEEVES FOR INSULATED PIPING, AND FOR TWO LAYERS OF 30 LB. FELT WRAPPING AROUND UN —INSULATED PIPING. VALVES: PROVIDE VALVES TO ISOLATE EACH COLD WATER RISER, BRANCH LINE, AND WHERE INDICATED ON PLANS CLEANOUTS: EXTERIOR HEAVY DUTY —CAST IRON, INSIDE CAULK OUTLET, BRASS INTERNAL PLUG, DUCTILE IRON SCORIATED HEAVY DUTY COVER JOSAM MODEL NO. 56040-5-15 OR EQUAL. STACK BASE DRYWALL PLASTER AND TILE WALLS. CAST IRON "T" BRANCH TEE COATED CAST IRON COUNTERSUNK PLUG, LEAD SEAL, CAST BRASS ROUND ACCESS COVER WITH ANCHOR LUGS, SATIN STAINLESS STEEL COVER SECURED WITH COUNTERSUNK SCREW. JOSAM MODEL NO. 58750-15 OR EQUAL. PLUMBING NOTES ROUTE ALL PIPING CONCEALED WITHIN WALLS, OR IN CHASES EXPECT AS SPECIFICALLY NOTED. PIPING ROUTING SHOWN IS SCHEMATIC AND IS INTENDED TO INDICATE GENERAL ROUTING. PLUMBING CONTRACTOR SHALL PROVIDE ANY ADDITIONAL OFFSETS AND FITTINGS REQUIRED FOR PROPER INSTALLATION AND TO MAINTAIN CLEARANCES AS ENCOUNTERED IN FIELD. DRAINAGE PIPING SHALL SLOPE NO LESS THAN 1/8" FALL PER FOOT. SEE ARCHITECTURAL DRAWINGS FOR EXACT PLUMBING FIXTURE LOCATIONS, MOUNTING HEIGHTS, AND DIMENSIONS. VERIFY INVERT ELEVATIONS AND EXACT LOCATION OF SEWERS BEFORE INSTALLATION. INSTALL DIELECTRIC UNIONS AT ALL CONNECTIONS OF DISIMILAR METALS. ROUGH —IN ALL WASTES AND SUPPLIES TO SPECIAL EQUIPMENT IN STRICT ACCORDANCE WITH MANUFACTURER'S RECCOMENDATIONS AND MAKE FINAL CONNECTIONS. ALL SUPPLIES SHALL BE VALVED. PIPING IN UNCONDITIONED SPACES SHALL BE FULLY INSULATED. PROVIDE SHUT—OFF VALVES FOR EACH FIXTURE OR AIR CHAMBERS WHERE REQUIRED FOR PROPER PERFORMANCE OF THE SYSTEM. DERM NOTES ON WATER —SERVER INSTALLATION A HORIZONTAL DISTANCE OF 10 FEET 'SHALL BE MAINTAINED BETWEEN WATER AND SEWER MAIN; WHEN 10 FEET HORIZONTAL DISTANCE CRITERIA CANNOT BE MET DUE TO AN EXISTING UNDERGROUND FACILITY CONFLICT, THE SEWER SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE WITH SLIP—ON OR MECHANICAL JOINTS AND PRESSURE TESTED AT 150 P.S.I. A VERTICAL DISTANCE OF AT LEAST 18 INCHES SHALL BE MAINTAINED BETWEEN ANY WATER AND SEWER MAINS. THE SEWER SHALL BE A DUCTILE IRON SINGLE 20 FEET LENGTH CENTERED ON THE CROSSING IF THE MINIMUM VERTICAL DISTANCE IS LESS THAN 18 INCHES OR IF THE SEWER IS INSTALLED ABOVE THE WATER MAIN (REGARDLESS OF SEPARATION) IN HIGHLY CONGESTED AREAS, WHERE EITHER WATER OR SEWER FACILITIES ARE EXISTING, IF THE SEPARATION REQUIREMENTS CANNOT MET, SPECIAL CONSIDERATION MAY BE GIVEN SUBJECT TO A COMPLETE EVALUATION OF THE CONDITIONS. THE MAXIMUM ALLOWABLE EXALTRATION RATE OF GRAVITY SANITARY SEWERS CONSTRUCTED IN A PUBLIC WELLFIELD PROTECTION AREA SHALL BE FIFTY (50) GALLON PER INCH PIPE DIAMETER PER MILE PER DAY FOR RESIDENTIAL LAND USE, AND TWENTY (20) GALLON PER INCH PIPE DIAMETER PER MILI PER DAY FOR NON—RESIDENTIAL LAND USE. FORCE MAIN SEWERS CONSTRUCTED IN A PUBLIC WELLFIELD PROTECTION AREA SHALL BE EITHER DUCTULIE IRON OR REINFORCED CONCRETE PRESSURE SEWER PIPES. —FOR DUCTILE IRON PIPE EXFILTRATION RATE SHALL NOT BE GREATER THAN THE ALLOWABLE LEAKAGE RATE SPECIFIED IN AMERICAN WATER WORKS ASSOCIATION STANDARD (AWWAS C600-82) AT A TEST PRESSURE OF 100 P.S.I. —FOR REINFORCED CONCRETE PRESSURE SANITARY REWER FORCE MAIN EXFILTRATION RATE SHALL NOT BE GREATER THAN HALF (1/2) THE ALLOWABLE LEAKAGE RATE SPECIFIED IN AWWAS 600-82 AT A TEST PRESSURE OF 100 P.S.I. THE CONTRACTOR SHALL VERIFY NATURE, DEPTH AND CHARACTER OF EXISTING UNDERGROUND UTILITIES PRIOR TO START OF CONSTRUCTION. ALL OTHER PUBLIC OR PRIVATE UTILITY FACILITIES SHALL BE CONSTRUCTED AT LEAST FIVE (5) FEET FROM ANY SEWER MAIN AS MEASURED FROM THE OUTSIDE BELL OF THE UTILITY PIPES. WHEN THE FIVE (5) FEET SEPARATION BETWEEN PROPOSED AND EXISTING LINES IS NOT POSSIBLE, THE CONTRACTOR SHALL HAND DIG OR EXPOSE THE WATER AND SEWER PIPES BEFORE PROCEEDING WITH POWER EQUIPMENT EXCAVATION. IN NO CASE SHALL THE CONTRACTOR INSTALL UTILITY PIPES, CONDUITS, CABLES, ETC., IN THE SAME TRENCH PARALLEL AND ABOVE AN EXISTING WATER OR SEWER PIPE EXCEPT WHERE THEY CROSS. ANY DESVIATION FROM NOTES 6, 7 AND 8 SHALL BE APPROVED IN WRITING BY THE RESPONSIBLE WATER AND SEWER UTILITY. MIAMI—DADE COUNTY HEALTH DEPARTMENT NOTES STORM DRAINAGE LINES IF ANY ARE TREATED THE SAME AS SANITARY SEWER LINES, EXFILTRATION DRAINAGE TRENCHES ARE EXEMPTED. MINIMUM 10 FEET HORIZONTAL SEPARATION BETWEEN WATER MAINS AND SEWER LINES IS REQUIRED. IF UNABLE TO MANTAIN MINIMUM SEPARATION HORIZONTALLY, EACH PIPE SHALL BE SHELVED WITH MINIMUN 18 INCHES VERTICAL SEPARATION. FORCE MAIN MUST HAVE AN 18 INCHES VERTICAL SEPARATION FROM WATER LINES; NO EXCEPTIONS. SEWER LINES, INCLUDING LATERALS, MUST HAVE 18 INCHES VERTICAL CLEARANCE BETWEEN WATER MAINS AND/OR 6 INCHES MINIMUM CLEARANCE IF SEWER LINE IS DIP AND HAS NO JOINTS WITHIN 10 FEET OF INTERSECTION (I.C., ONE 20 FT. JOIN DIP CENTERED ON INTERSECTION), STORM DRAINAGE LINES ARE EXEMPT IF DIP WATER MAIN SEPARATION OF 6 INCHES IS MAINTAINED AND BOTH PIPES HAVE NO JOINTS WITHIN 10 FEET OF INTERSECTION. SEWER LATERALS (SERVICES) SHALL HAVE 18 INCHES CLEARANCE FROM WATER MAINS. 3'-2" 4'-0" SLOPE SHOULDER 1'-0' EX. GRADE NGVD WATER TABLE NGVD 12 f BLOT OF SAND TRENCH NGVD SAND PER 64E-6 ABSORPTION BED 6" SOIL & SOD TOP OF SOIL & SOD NGVD PLUMBING FIXTURE CONNECTION SCHEDULE ITEM DESCRIPTION WATER SUPPLY SANITARY COLD HOT TRAP B D BIDET 1 /2" 1/2" 1 1/2" 1 1/2" BT BATHTUB 1/2" 1/2" 2" 2" KS KITCHEN SINK 1/2" 1/2" 1 1/2" 1 1/2" LAV LAVATORY 1/2" 1/2" 1 1/2" 1 1/2" SH SHOWER 1 /2" 1 /2" 2" 2" WC WATER CLOSET 1/2" — 3" — DW DISHWASHER — 1/2" 1" hose — W WASHER 1/2" 1/2" 3" 3" -- REFRIGERATOR — 1/2" — — NOTE: BATHTUB SHALL BE FIXED FITTINGS (NO SCREW JOINT ALLOWED) raltlu'Ar;]I I[eig�elll►[9, SYMBOL H n A PT BD BT CO CW EWH GCO HW KS LAV PT SAN SH VTR W WC 5'-0" MIN. TO HOUSE FOUNDATION m DRAINFIEED CRESS SECTION. NTS DRAINFIELD PER HEALTH DEPT CHAP 64E-6 DESCRIPTION SANITARY PIPE. VENT PIPE. DOMESTIC COLD WATER PIPE. DOMESTIC HOT WATER PIPE. CONDENSATE DRAIN PIPE. GATE VALVE. "P" TRAP. WALL CLEAN —OUT. AIR CHAMBER. VENT THROUGH PRESSURE RELIEF PIPE BIDET BATHTUB WALL CLEANOUT DOMESTIC COLD WATER ELECTRIC WATER HEATER GRADE CLEANOUT DOMESTIC HOT WATER KITCHEN SINK LAVATORY PRESSURE RELIEF SANITARY SHOWER VENT THROUGH ROOF WASHER WATER CLOSET PROPOSED HOUSE FOUNDATION 6„ 1,_0„ TOP OF ABSORPTION BED NGVD BOT OF ABSORPTION BED NGVD WATER TABLE NGVD REVISIONS BY E-+ W Q,(00 a) u M N o Qi c Z v L`_ v I Q+ • o ri N 7 d U) • N x o .. m U O a o Q w O t-- z W J w U oz w LJJ V) O LLJ LLJ U a > 0 () 0r w Q = L o z W � o O cn oQoQ Q U � -2 DRAWN SL CHECKED JCS DATE 11-20-08 SCALE AS NOTED JOB NO. 2008-15 SHEET INDEX PLUMBING NOTES SHEET NUMBER Pm2_