11-629-004___._.__.__......___._.._.._._._._ __..._.__......... . __ ..................... DOOR SCHEDULE DOORS• _ __________........_ ___ _........ DENOTES COMPOSITION, FINISH AND HARDWARE SIZE COMPOSITION FINISH HARDWARE FQ- w O W W V) U U WZ UZ w�a WZ -1 O �� 0 �a Q 0Q_ OW p w } �p O = Y �W U)W p O U _3L aS _ S p IW- Z p _ Oz JQ a wo REMARKS § 1 T-0" 6'-8" 1 314" • • • • SWING DOOR 2 314" 6'-8" 1 3/4" • • • • SWING DOOR 3 (2)3'-0" 6'-8" 1 3/4" • • • FRENCH DOOR 4 2'-10" 6'-8" 1 3/4" • • • SWING DOOR 5 T-0" 6'-8" • • • POCKET DOOR 6 2)2'-6" 6'-8" • • BI-FOLD DOOR 7 2'-6" 6'-8" r131" • • BI-FOLD DOOR W/ LOUVER E EXISTING SAFETY / EGRESS DOOR NOTES 1. EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED TO PERMIT THE OPENING OF THE LOCKED DOOR FROM THE OUTSIDE IN A EMERGENCY. 2. ALL EXTERIOR DOORS TO HAVE MDCPA. GENERAL NOTES I. GENERAL NOTES: 1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL ORDINANCES GOVERNING. 2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING THE WORK. 3. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL SAFETY RELATED O.S.H.A. REQUIREMENTS DURING CONSTRUCTION. 4. ALL WORK SHALL BE PERFORMED BY A LICENSED AND INSURED STATE CERTIFIED GENERAL CONTRACTOR OR BY THE OWNER IF APPROVED BY THE LOCAL BUILDING DEPARTMENT OFFICIAL. 5. ALL WINDOWS USED SHALL HAVE BROWARD COUNTY PRODUCT APPROVAL. 6. SECONDARY MEANS OF ESCAPE SHALL CONFORM TO F.B.C. 1055.4.4 & (.3) & (N.F.P.A. 22-2.1.2.C.) WINDOWS USED AS SECOND MEANS OF ESCAPE MUST PROVIDE A CLEAR OPENING (WHEN FULLY OPENED) OF NOT LESS THAN TWENTY INCHES (20") IN WIDTH, TWENTY FOUR INCHES (24") IN HEIGHT AND 5.7 SQUARE FEET IN AREA; AND THE BOTTOM OF THE OPENING SHALL NOT BE MORE THAN FORTY FOUR INCHES (44") OFF THE FLOOR. 7. WOOD TRUSS MANUFACTURER SHALL SUBMIT SHOP' DRAWINGS AND CALCULATIONS FOR ARCHITECT'S APPROVAL PRIOR TO TRUSS FABRICATION. WOOD TRUSSES SHALL BE DESIGNED, BY A FLORIDA REGISTERED P.E. 8. ALL NEW WALLS ARE TO BE ALIGNED WITH ADJACENT WALLS SO THAT NO SEAM IS VISIBLE. 9' GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS, ANY DISCREPANCIES SHALL BE BROUGHT TO THE ARCHITECT'S ATTENTION PRIOR TO START OF CONSTRUCTION. ANY CONDITION NOT BROUGHT TO THE ATTENTION OF THE ARCHITECT PRIOR TO BID SHALL BE THE RESPONSABILITY OF THE GENERAL CONTRACTOR. INTERIOR DESIGN CHANGES MADE BY THE ARCHITECT ARE THE ONLY CHANGE ORDERS THAT WILL BE ACCEPTED. II. WOOD: 1. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED. III. MECHANICAL: 1. ALL MECHANICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES GOVERNING. IV. PLUMBING: 1. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES GOVERNING. V. ELECTRICAL: 1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH THE LATEST EDITION OF THE FLORIDA BUILDING CODE, THE NATIONAL ELECTRICAL CODE AND ALL LOCAL CODES GOVERNING. VI. SHOP DRAWING SUBMITTALS: 1. REVIEW SHOP DRAWINGS, CATALOG CUTS, PRODUCT DATA, AND SAMPLES BEFORE SUBMISSION. DETERMINE AND VERIFY: A. FIELD MEASUREMENTS. B. FIELD CONSTRUCTION CRITERIA. C. CONFORMANCE WITH CONSTRUCTION DOCUMENTS. D. COORDINATE EACH SUBMITTAL WITH REQUIREMENTS OF THE WORK AND OF CONSTRUCTION DOCUMENTS. 2. THE CONTRACTOR SHALL SUBMIT A MINIMUM OF FOUR (4) SETS OF SHOP DRAWINGS FOR REVIEW AND APPROVAL. EACH SUBMITTAL SHALL BE INCLUSIVE OF, BUT NOT LIMITED TO, BROWARD COUNTY PRODUCT APPROVAL, MANUFACTURERS SPECIFICATIONS, INSTALLATION RECOMMENDATIONS, COLOR SAMPLES, AND WARRANTIES. 3. DO NOT ORDER OR FABRICATE MATERIALS UNTIL SHOP DRAWINGS HAVE BEEN REVIEWED AND APPROVED BY A/E. ALWAYS MAINTAIN AND HAVE AVAILABLE FOR REFERENCE A FIELD COPY OF ACCEPTED SHOP DRAWINGS AT THE JOB SITE. 4. SHOP DRAWING REQUIRED: WINDOWS, DOORS, HURRICANE SHUTTERS, STRUCTURAL STEEL COLUMNS AND ANY / ALL PRE -FABRICATED COMPONENTS. VII. SECURITY AND FORCED ENTRY PREVENTION 1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH IN THE LATEST EDITION OF THE FLORIDA BUILDING CODE. 2. ALL EXTERIOR SOLID CORE DOORS SHALL BE A MINIMUM OF 1 3/4" THICK AND SHALL COMPLY WITH THE F.B.C. 2007 WINDOW SCHEDULE WINDOWS •DENOTES TYPE, FINISH AND GLASS DESIGNATION TYPE FINISH GLASS N w W 2 p Z p Z z p w cn F U Q Q U O REMARKS A 6'-0' X 514" • • • EGRESS B T-0" X T-0" • • • E EXISTING NOTE: 1. ALL INTERIOR GLAZING TO COMPLY W/ FEDERAL STANDARD 16 CFR 120. GLAZING TO BE CATEGORY II, CAPABLE TO WITHSTAND A 400LB. IMPACT. 2. ALL EXTERIOR WINDOWS TO HAVE MDCPA. 3. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE FLORIDA BUILDING CODE. 4. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED BOLT. 5. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/8" MIN. THROW BOLTS WITH INSERTS. 6. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES. 7. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE NON -REMOVABLE PINS AND NON -EXPOSED SCREWS. 8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN NATIONAL STANDARDS INSTITUTES STANDARD 297.1. 9. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE INSIDE LOCKING ACTIVATION DEVICE OF LOOSE AND SWING DOORS SHALL COMPLY WITH THE ANSI STANDARD 297.1. 10. NOT USED. 11. ALL WINDOWS SHALL COMPLY WITH THE F.B.C. 2007. WINDOWS SHALL BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH THE ARCHITECTURAL ALUMINUM MAGS ASSOCIATION STANDARDS FOR FORCE ENTRY RESISTANCE, A.A.M.A. 1303.3 PROVIDE LOCKS AS PER F.B.C. 2007 EDITION EXTERIOR WINDOW SHALL BE LOCKED WITH DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN OPERABLE DIRECTION. 12. IN ADDITION, ALL GLAZING THAT IS PERMISSIBLE SHALL COMPLY WITH THE F.B.C. 2007 EDITION 13. ALUMINUM WINDOWS SHALL COMPLY WITH F.B.C. 2007 14. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR SCOPE OR VISION PANELS. 15. ALL EGRESS WINDOWS TO HAVE A CLEAR OPENING OF NOT LESS THAN 30" IN WIDTH AND 24" IN HEIGHT, MINIMUM 5.7 S.F. IN AREA HEIGHT TO OPENING SHALL NOT EXCEED 44" ABOVE FINISH FLOOR. 16. CONTRACTOR TO VERIFY ALL AS -BUILT OPENINGS PRIOR TO FABRICATION. VIII. CLEANING: 1, IN ADDITION TO REMOVAL OF RUBBISH AND LEAVING BUILDINGS "BROOM CLEAN": A. REPLACE BROKEN GLASS. B. REMOVE PAINT SPOTS AND SMEARS, STAINS, MARKS, AND DIRT TO PROVIDE CLEAN SURFACES. C. CLEAN GLASS, HARDWARE, FIXTURES, CASEWORK, AND EQUIPMENT. D. WASH CONCRETE SURFACES, TILE FLOORS, TILE WALLS AND ANY OTHER IMPERVIOUS FLOOR AND WALL SURFACES IX. ENVIRONMENTAL PROTECTION: 1. CONTROL AMOUNT OF DUST RESULTING FROM CONSTRUCTION OR DEMOLITION TO PREVENT SPREAD OF DUST TO OTHER BUILDINGS AND TO AVOID CREATION OF A NUISANCE IN SURROUNDING AREAS. USE OF WATER TO CONTROL DUST WILL NOT BE ALLOWED WHEN IT WILL RESULT IN, OR CREATE HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOODING. 2. TRAFFIC MAINTENANCE: CONDUCT REMOVAL OPERATIONS TO MAINTAIN TRAFFIC ALONG EXISTING STREETS AND WALKS. KEEP PAVED STREETS AND WALKWAYS FREE OF DEBRIS. REMOVE MATERIAL AND OTHER MATTER TRACKED OR FALLEN ONTO TRAFFIC SURFACES. 3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION MATERIALS INCLUDING DEBRIS AND DUST, AND DISPOSE OF LEGALLY OFF SITE. USE METHODS APPROVED BY A/E BEFORE BEGINNING CLEANUP OPERATIONS. USE OF BLOWERS TO DISTRIBUTE DUST IS NOT ALLOWED TERMITE PROTECTION: CONTRACTOR TO TREAT THE SOIL AGAINST SUBTERRANEAN TERMITES AND SUBMIT TO THE BUILDING DEPARTMENT A CERTIFICATE OF COMPLIANCE FROM A LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWINGS STATEMENT. "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE WITH RULES AND LAWS ESTABLISHED BY FLORIDA DEPARTMENT OF AGRICULTURE AND SERVICES" MANSORY OPENINGS 1.THE INFORMATION PROVIDED IN THE DOOR AND WINDOW SCHEDULES NEEDS TO BE VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING CONSTRUCTION. 2. THE MANUFACTURER SPECIFIED, IF ANY, (AND ANY MODEL NUMBERS, IF PROVIDED) ARE INTENDED ONLY AS A GENERAL GUIDELINE TO ESTABLISH A DESIGN STANDARD. 3. THE DIMENSIONS SHOWN ON THE FLOOR PLANS HAVE BEEN ROUNDED -OFF ONLY FOR THE PURPOSE OF ESTABLISHING THE GENERAL LOCATION OF OPENINGS ON THE ARCHITECTURAL AND STRUCTURAL DRAWINGS. 4. THE DIMENSIONS SHOWN ON THE SCHEDULES FOR THE WINDOW AND DOOR ASSEMBLIES, AND THEIR RESPECTIVE MASONRY OPENINGS, ARE NOT EXACT. THEY ARE INTENDED ONLY TO CALL THE CONTRACTOR'S ATTENTION TO THE VARIATIONS IN OPENING SIZES REQUIRED BY DIFFERENT WINDOW AND DOOR MANUFACTURERS. THE CONTRACTOR IS URGED TO VERIFY THE OPENINGS REQUIRED BY THE MANUFACTURER SELECTED (BY THE CONTRACTOR OR BY THE OWNER) FOR THIS PROJECT. 5. THE CONTRACTOR SHALL CONFIRM THE REQUIREMENTS AS TO SIZE, SHAPE AND ANCHORING OF WOOD BUCKS FOR DOORS AND WINDOWS WITH THE SELECTED MANUFACTURER TO PROVIDE THE MOST EXACT AND BEST FITTING OPENING. 6. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE THE EXACT DIMENSION OF THE MASONRY OPENINGS WITH THE WINDOW AND DOOR ASSEMBLIES, IN ANY AND ALL CASES. THE CONTRACTOR SHALL NOT DEPEND ON THE INFORMATION GIVEN IN THESE PLANS AND SCHEDULES FOR THE PURPOSE OF COORDINATING THIS WORK FOR CONSTRUCTION. THE MEANS AND METHODS OF CONSTRUCTION ARE, AND SHALL REMAIN, THE CONTRACTOR'S RESPONSIBILITY. 7. IN THE EVENT OF A CHANGE IN DOOR OR WINDOW MANUFACTURER(S), WHETHER SELECTED BY THE OWNER OR THE CONTRACTOR, THE PLANS AND SCHEDULES SHOULD BE REVISED SO THAT THE PERMIT SET REFLECTS THE CHANGE AND, THEN AFTER CONSTRUCTION, SO THAT THE (FINAL) RECORD DRAWINGS REFLECTS THE ACTUAL, AS -BUILT CONDITION. CI rY U;= sou,rri mi;x toii'` BIj1(.01NG Oc Pr. S fRUCTUR-Al- S3_:CTION x II a H U H _ `° W M cn rM N c � .. ul ., •to n x o Z t° O d I n N Q • 00 Q) N uj •• 41 N X N L O Q O o.. W 1- O F- Z LLJ w U oz w W cn (/) O W W � O Q > � elfO 2-1v r n J Fw- Lv Of= Q Q 0 LLJ Ln o O cn Q 2D Q Q U Q� DRAWN SL CHECKED JCS DATE 3-30-09 SCALE AS NOTED JOB NO. 2008- SHEET INDEX GENERAL NOTE SHEET NUMBER