11-629-004___._.__.__......___._.._.._._._._
__..._.__......... . __ .....................
DOOR
SCHEDULE
DOORS•
_
__________........_ ___ _........
DENOTES COMPOSITION,
FINISH AND HARDWARE
SIZE COMPOSITION
FINISH
HARDWARE
FQ- w O W
W V)
U U
WZ UZ
w�a
WZ
-1 O
��
0
�a
Q 0Q_
OW
p
w }
�p
O
= Y �W U)W
p O U _3L aS
_ S p
IW-
Z
p
_ Oz
JQ
a
wo
REMARKS
§
1
T-0"
6'-8"
1 314"
•
•
•
•
SWING DOOR
2
314"
6'-8"
1 3/4"
•
•
•
•
SWING DOOR
3
(2)3'-0"
6'-8"
1 3/4"
•
•
•
FRENCH DOOR
4
2'-10"
6'-8"
1 3/4"
•
•
•
SWING DOOR
5
T-0"
6'-8"
•
•
•
POCKET DOOR
6
2)2'-6"
6'-8"
•
•
BI-FOLD DOOR
7
2'-6"
6'-8"
r131"
•
•
BI-FOLD DOOR W/ LOUVER
E
EXISTING
SAFETY / EGRESS DOOR NOTES
1.
EVERY BATHROOM DOOR LOCK SHALL BE DESIGNED
TO PERMIT THE OPENING OF THE LOCKED
DOOR FROM THE OUTSIDE IN A EMERGENCY.
2.
ALL EXTERIOR DOORS TO HAVE MDCPA.
GENERAL NOTES
I. GENERAL NOTES:
1. ALL WORK SHALL COMPLY WITH THE LATEST EDITION OF THE FLORIDA BUILDING
CODE AND ALL LOCAL ORDINANCES GOVERNING.
2. CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AND
NOTIFY THE ARCHITECT OF ANY DISCREPANCIES BEFORE STARTING THE
WORK.
3. CONTRACTOR SHALL BE RESPONSIBLE FOR COMPLIANCE WITH ALL
SAFETY RELATED O.S.H.A. REQUIREMENTS DURING CONSTRUCTION.
4. ALL WORK SHALL BE PERFORMED BY A LICENSED AND INSURED STATE
CERTIFIED GENERAL CONTRACTOR OR BY THE OWNER IF APPROVED BY THE
LOCAL BUILDING DEPARTMENT OFFICIAL.
5. ALL WINDOWS USED SHALL HAVE BROWARD COUNTY PRODUCT APPROVAL.
6. SECONDARY MEANS OF ESCAPE SHALL CONFORM TO F.B.C. 1055.4.4 & (.3)
& (N.F.P.A. 22-2.1.2.C.) WINDOWS USED AS SECOND MEANS OF ESCAPE MUST
PROVIDE A CLEAR OPENING (WHEN FULLY OPENED) OF NOT LESS THAN
TWENTY INCHES (20") IN WIDTH, TWENTY FOUR INCHES (24") IN HEIGHT AND 5.7
SQUARE FEET IN AREA; AND THE BOTTOM OF THE OPENING SHALL NOT BE
MORE THAN FORTY FOUR INCHES (44") OFF THE FLOOR.
7. WOOD TRUSS MANUFACTURER SHALL SUBMIT SHOP' DRAWINGS AND
CALCULATIONS FOR ARCHITECT'S APPROVAL PRIOR TO TRUSS
FABRICATION. WOOD TRUSSES SHALL BE DESIGNED, BY A FLORIDA
REGISTERED P.E.
8. ALL NEW WALLS ARE TO BE ALIGNED WITH ADJACENT WALLS SO
THAT NO SEAM IS VISIBLE.
9' GENERAL CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND
CONDITIONS, ANY DISCREPANCIES SHALL BE BROUGHT TO THE
ARCHITECT'S ATTENTION PRIOR TO START OF CONSTRUCTION.
ANY CONDITION NOT BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO BID SHALL BE THE RESPONSABILITY OF THE
GENERAL CONTRACTOR. INTERIOR DESIGN CHANGES MADE BY
THE ARCHITECT ARE THE ONLY CHANGE ORDERS THAT WILL BE
ACCEPTED.
II. WOOD:
1. ALL WOOD IN CONTACT WITH CONCRETE SHALL BE PRESSURE TREATED.
III. MECHANICAL:
1. ALL MECHANICAL WORK SHALL BE DONE IN ACCORDANCE WITH
THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES
GOVERNING.
IV. PLUMBING:
1. ALL PLUMBING WORK SHALL BE DONE IN ACCORDANCE WITH
THE LATEST EDITION OF THE FLORIDA BUILDING CODE AND ALL LOCAL CODES
GOVERNING.
V. ELECTRICAL:
1. ALL ELECTRICAL WORK SHALL BE DONE IN ACCORDANCE WITH
THE LATEST EDITION OF THE FLORIDA BUILDING CODE, THE NATIONAL ELECTRICAL
CODE AND ALL LOCAL CODES GOVERNING.
VI. SHOP DRAWING SUBMITTALS:
1. REVIEW SHOP DRAWINGS, CATALOG CUTS, PRODUCT DATA, AND SAMPLES
BEFORE SUBMISSION. DETERMINE AND VERIFY:
A. FIELD MEASUREMENTS.
B. FIELD CONSTRUCTION CRITERIA.
C. CONFORMANCE WITH CONSTRUCTION DOCUMENTS.
D. COORDINATE EACH SUBMITTAL WITH REQUIREMENTS OF THE WORK AND OF
CONSTRUCTION DOCUMENTS.
2. THE CONTRACTOR SHALL SUBMIT A MINIMUM OF FOUR (4) SETS OF SHOP
DRAWINGS FOR REVIEW AND APPROVAL. EACH SUBMITTAL SHALL BE
INCLUSIVE OF, BUT NOT LIMITED TO, BROWARD COUNTY PRODUCT APPROVAL,
MANUFACTURERS SPECIFICATIONS, INSTALLATION RECOMMENDATIONS,
COLOR SAMPLES, AND WARRANTIES.
3. DO NOT ORDER OR FABRICATE MATERIALS UNTIL SHOP DRAWINGS
HAVE BEEN REVIEWED AND APPROVED BY A/E. ALWAYS MAINTAIN AND
HAVE AVAILABLE FOR REFERENCE A FIELD COPY OF ACCEPTED SHOP
DRAWINGS AT THE JOB SITE.
4. SHOP DRAWING REQUIRED: WINDOWS, DOORS, HURRICANE SHUTTERS,
STRUCTURAL STEEL COLUMNS AND ANY / ALL
PRE -FABRICATED COMPONENTS.
VII. SECURITY AND FORCED ENTRY PREVENTION
1. PROVIDE INTRUSION AND BURGLARY SECURITY DEVICES AS SET FORTH IN
THE LATEST EDITION OF THE FLORIDA BUILDING CODE.
2. ALL EXTERIOR SOLID CORE DOORS SHALL BE A MINIMUM OF 1 3/4" THICK
AND SHALL COMPLY WITH THE F.B.C. 2007
WINDOW
SCHEDULE
WINDOWS
•DENOTES TYPE, FINISH AND GLASS
DESIGNATION
TYPE
FINISH
GLASS
N
w
W
2
p Z
p
Z
z
p
w
cn
F
U
Q Q
U
O
REMARKS
A
6'-0' X 514"
•
•
•
EGRESS
B
T-0" X T-0"
•
•
•
E
EXISTING
NOTE:
1. ALL INTERIOR GLAZING TO COMPLY W/ FEDERAL STANDARD 16 CFR 120. GLAZING TO BE CATEGORY II, CAPABLE TO
WITHSTAND A 400LB. IMPACT.
2. ALL EXTERIOR WINDOWS TO HAVE MDCPA.
3. ALL LOCKS ON EXTERIOR DOORS SHALL BE CAPABLE OF RESISTING A
FORCE OF 300 LB. APPLIED IN ANY MOVEABLE DIRECTION AND IN
ACCORDANCE WITH RESISTANCE STANDARDS SET FORTH IN THE
FLORIDA BUILDING CODE.
4. ALL SINGLE EXTERIOR SWING DOORS SHALL HAVE A LOCK TO BE KEY
OPERATED FROM THE EXTERIOR WITH A MINIMUM OF 6000 POSSIBLE KEY
CHANGES OR LOCKING AUXILIARY SINGLE DEAD BOLT WITH HARDENED
BOLT.
5. THE ACTIVE LEAF OF PAIRS OF EXTERIOR SWING DOORS SHALL HAVE
SAME LOCKS AS REQUIRED FOR SINGLE EXTERIOR SWING DOORS. THE
INACTIVE LEAF SHALL HAVE MULTIPLE POINTS OF LOCKS WITH 5/8" MIN.
THROW BOLTS WITH INSERTS.
6. JAMBS OF ALL EXTERIOR OFFSET TYPE IN SWING DOORS SHALL BE
RABBETED, OR OF SIMILAR FABRICATION, TO PREVENT DEFEATING THE
PURPOSE OF THE STRIKE AND THE INTEGRITY OF THE LOCKS AND LATCHES.
7. HINGES ON EXTERIOR OUT SWINGING DOORS SHALL HAVE
NON -REMOVABLE PINS AND NON -EXPOSED SCREWS.
8. GLASS AND EXTERIOR DOORS SHALL COMPLY WITH THE AMERICAN
NATIONAL STANDARDS INSTITUTES STANDARD 297.1.
9. VISION PANEL EXTERIOR DOORS OTHER THAN GLAZING WITHIN 40" OF THE
INSIDE LOCKING ACTIVATION DEVICE OF LOOSE AND SWING DOORS SHALL
COMPLY WITH THE ANSI STANDARD 297.1.
10. NOT USED.
11. ALL WINDOWS SHALL COMPLY WITH THE F.B.C. 2007. WINDOWS SHALL
BE INSTALLED AND CONSTRUCTED SO THAT NO PANEL CAN BE LIFTED FROM
THE TRACKS WHEN IN THE LOCKED POSITION AND SO AS TO COMPLY WITH
THE ARCHITECTURAL ALUMINUM MAGS ASSOCIATION STANDARDS FOR FORCE
ENTRY RESISTANCE, A.A.M.A. 1303.3 PROVIDE LOCKS AS PER F.B.C.
2007 EDITION EXTERIOR WINDOW SHALL BE LOCKED WITH
DEVICE CAPABLE OF WITHSTANDING A FORCE OF 150 LB. APPLIED IN AN
OPERABLE DIRECTION.
12. IN ADDITION, ALL GLAZING THAT IS PERMISSIBLE SHALL COMPLY WITH
THE F.B.C. 2007 EDITION
13. ALUMINUM WINDOWS SHALL COMPLY WITH F.B.C. 2007
14. FRONT MAIN ENTRANCE DOORS SHALL BE PROVIDED WITH A DOOR
SCOPE OR VISION PANELS.
15. ALL EGRESS WINDOWS TO HAVE A CLEAR OPENING OF NOT LESS THAN 30"
IN WIDTH AND 24" IN HEIGHT, MINIMUM 5.7 S.F. IN AREA HEIGHT TO OPENING
SHALL NOT EXCEED 44" ABOVE FINISH FLOOR.
16. CONTRACTOR TO VERIFY ALL AS -BUILT OPENINGS PRIOR TO
FABRICATION.
VIII. CLEANING:
1, IN ADDITION TO REMOVAL OF RUBBISH AND LEAVING BUILDINGS "BROOM
CLEAN":
A. REPLACE BROKEN GLASS.
B. REMOVE PAINT SPOTS AND SMEARS, STAINS, MARKS, AND DIRT TO
PROVIDE CLEAN SURFACES.
C. CLEAN GLASS, HARDWARE, FIXTURES, CASEWORK, AND EQUIPMENT.
D. WASH CONCRETE SURFACES, TILE FLOORS, TILE WALLS AND ANY OTHER
IMPERVIOUS FLOOR AND WALL SURFACES
IX. ENVIRONMENTAL PROTECTION:
1. CONTROL AMOUNT OF DUST RESULTING FROM CONSTRUCTION OR
DEMOLITION TO PREVENT SPREAD OF DUST TO OTHER BUILDINGS AND TO
AVOID CREATION OF A NUISANCE IN SURROUNDING AREAS. USE OF WATER TO
CONTROL DUST WILL NOT BE ALLOWED WHEN IT WILL RESULT IN, OR CREATE
HAZARDOUS OR OBJECTIONABLE CONDITIONS SUCH AS FLOODING.
2. TRAFFIC MAINTENANCE: CONDUCT REMOVAL OPERATIONS TO MAINTAIN
TRAFFIC ALONG EXISTING STREETS AND WALKS. KEEP PAVED STREETS AND
WALKWAYS FREE OF DEBRIS. REMOVE MATERIAL AND OTHER MATTER
TRACKED OR FALLEN ONTO TRAFFIC SURFACES.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL CONSTRUCTION
MATERIALS INCLUDING DEBRIS AND DUST, AND DISPOSE OF LEGALLY OFF
SITE. USE METHODS APPROVED BY A/E BEFORE BEGINNING CLEANUP
OPERATIONS. USE OF BLOWERS TO DISTRIBUTE DUST IS NOT ALLOWED
TERMITE PROTECTION:
CONTRACTOR TO TREAT THE SOIL AGAINST SUBTERRANEAN TERMITES AND
SUBMIT TO THE BUILDING DEPARTMENT A CERTIFICATE OF COMPLIANCE FROM
A LICENSED PEST CONTROL COMPANY THAT CONTAINS THE FOLLOWINGS
STATEMENT. "THE BUILDING HAS RECEIVED A COMPLETE TREATMENT FOR THE
PREVENTION OF SUBTERRANEAN TERMITES, TREATMENT IS IN ACCORDANCE
WITH RULES AND LAWS ESTABLISHED BY FLORIDA DEPARTMENT OF AGRICULTURE
AND SERVICES"
MANSORY OPENINGS
1.THE INFORMATION PROVIDED IN THE DOOR AND WINDOW SCHEDULES NEEDS TO BE
VERIFIED BY THE CONTRACTOR PRIOR TO COMMENCING CONSTRUCTION.
2. THE MANUFACTURER SPECIFIED, IF ANY, (AND ANY MODEL NUMBERS, IF PROVIDED)
ARE INTENDED ONLY AS A GENERAL GUIDELINE TO ESTABLISH A DESIGN STANDARD.
3. THE DIMENSIONS SHOWN ON THE FLOOR PLANS HAVE BEEN ROUNDED -OFF ONLY FOR
THE PURPOSE OF ESTABLISHING THE GENERAL LOCATION OF OPENINGS ON THE
ARCHITECTURAL AND STRUCTURAL DRAWINGS.
4. THE DIMENSIONS SHOWN ON THE SCHEDULES FOR THE WINDOW AND DOOR
ASSEMBLIES, AND THEIR RESPECTIVE MASONRY OPENINGS, ARE NOT EXACT. THEY
ARE INTENDED ONLY TO CALL THE CONTRACTOR'S ATTENTION TO THE VARIATIONS IN
OPENING SIZES REQUIRED BY DIFFERENT WINDOW AND DOOR MANUFACTURERS.
THE CONTRACTOR IS URGED TO VERIFY THE OPENINGS REQUIRED BY THE
MANUFACTURER SELECTED (BY THE CONTRACTOR OR BY THE OWNER) FOR THIS
PROJECT.
5. THE CONTRACTOR SHALL CONFIRM THE REQUIREMENTS AS TO SIZE, SHAPE AND
ANCHORING OF WOOD BUCKS FOR DOORS AND WINDOWS WITH THE SELECTED
MANUFACTURER TO PROVIDE THE MOST EXACT AND BEST FITTING OPENING.
6. THE CONTRACTOR IS RESPONSIBLE TO COORDINATE THE EXACT DIMENSION OF THE
MASONRY OPENINGS WITH THE WINDOW AND DOOR ASSEMBLIES, IN ANY AND ALL
CASES. THE CONTRACTOR SHALL NOT DEPEND ON THE INFORMATION GIVEN IN
THESE PLANS AND SCHEDULES FOR THE PURPOSE OF COORDINATING THIS WORK
FOR CONSTRUCTION. THE MEANS AND METHODS OF CONSTRUCTION ARE, AND
SHALL REMAIN, THE CONTRACTOR'S RESPONSIBILITY.
7. IN THE EVENT OF A CHANGE IN DOOR OR WINDOW MANUFACTURER(S), WHETHER
SELECTED BY THE OWNER OR THE CONTRACTOR, THE PLANS AND SCHEDULES
SHOULD BE REVISED SO THAT THE PERMIT SET REFLECTS THE CHANGE AND, THEN
AFTER CONSTRUCTION, SO THAT THE (FINAL) RECORD DRAWINGS REFLECTS THE
ACTUAL, AS -BUILT CONDITION.
CI rY U;= sou,rri mi;x toii'`
BIj1(.01NG Oc Pr.
S fRUCTUR-Al- S3_:CTION
x
II
a
H
U
H
_
`°
W
M
cn
rM
N
c
�
..
ul
.,
•to
n
x o
Z
t° O
d
I
n N
Q
•
00
Q)
N
uj
••
41
N
X
N
L
O
Q
O
o..
W
1-
O
F-
Z
LLJ
w
U
oz
w
W
cn
(/)
O
W
W
�
O
Q
>
�
elfO
2-1v
r n
J
Fw-
Lv
Of=
Q
Q
0
LLJ
Ln
o
O
cn
Q
2D
Q
Q
U
Q�
DRAWN
SL
CHECKED
JCS
DATE
3-30-09
SCALE
AS NOTED
JOB NO.
2008-
SHEET INDEX
GENERAL NOTE
SHEET NUMBER