13-1361-006GENERAL PLUMBING NOTES 1. ALL WORK SHALL CONFORM WITH ALL LOCAL, STATE, FEDERAL 7. PROVIDE MEANS "FURNISH AND INSTALL". ORDINANCES AND BUILDING CODES 2010 GOVERNING THE INSTALLATION OF THE PLUMBING SYSTEM, IF WORK AS LAID B. DO A COMPLETE JOB, EVERYTHING CONNECTED, READY FOR USE. OUT, INDICATED OR SPECIFIED IS CONTRARY TO OR CONFLICTS WITH LOCAL ORDINANCES, BUILDING CODES AND REGULATIONS, I 9. SHOP DRAWINGS: CONTRACTOR SHALL FURNISH THE ENGINEER THE CONTRACTOR SHALL REPORT IN WRITING TO THE WITH SHOP DRAWINGS OF EQUIPMENT PRIOR TO PURCHASE ARCHITECT/ENGINEER BEFORE SUBMITTING A RID. THE FOR APPROVAL. ARCHITECT/ENGINEER WILL THEN ISSUE INSTRUCTIONS AS HOW TO PROCEED. M AT COMPLETION OF JOB THE PLUMBING CONTRACTOR SHALL GIVE THE OWNER AN AS —BUILT SET OF REPRODUCIBLE SEPIAS 2. THE DRAWINGS ARE TO BE CONSIDERED DIAGRAMMATIC, NOT SHOWING THE EXACT LOCATION OF ALL INSTALLATIONS, NECESSARILY SHOWING IN DETAIL OR TO SCALE ALL OF THE MINOR ITEMS. UNLESS SPECIFIC DIMENSIONS ARE SHOWN, THE 11. PLUMBING CONTRACTOR SHALL PRESSURE TEST ALL PIPING AS STRUCTURAL, ARCHITECTURAL AND SITE CONDITIONS SHALL REQUIRED BY CODE. TEST SHALL BE WITNESSED AND APPROVED GOVERN THE EXACT LOCAITNS. CONTRACTOR SHALL FOLLOW BY PROPER AUTHORITIES. DRAWINGS IN LAYING OUT WORK, CHECK DRAWINGS OF ALL TRADES TO VERIFY SPACES IN WHICH WORK WILL BE INSTALLED 12, THE PLUMBING CONTRACTOR SHALL WARRANT ALL AND MAINTAIN MAXIMUM HEAD ROOM, AND SPACE CONDITIONS WORKMANSHIP AND MATERIALS FOR ONE YEAR FROM THE DATE AT ALL POINTS. WHERE HEAD ROOM, OR SPACE CONDITIONS OF FINAL WORK ACCEPTANCE BY OWNER. ANY BREAKDOWN APPEAR INADEQUATE, ARCHITECT/ ENGINEER SHALL BE OCCURRING IN FIRST YEAR SHALL BE REPAIRED AT NO EXPENSE NOTIFIED BEFORE PROCEEDING WITH INSTALLATION. THIS TO THE OWNER. CONTRACTOR SHALL, WITHOUT EXTRA CHARGE, MAKE FIELD MODIFICATION IN LAYOUT AS NEEDED TO PREVENT CONFLICT 13, PROVIDE BATHROOM FIXTURES AS SPECIFIED. WITH WORK OF VARIOUS TRADES OR FOR PROPER EXECUTION OF THE WORK . 14. PROVIDE SHUT—OFF VALVE FOR EACH FIXTURE, 3. EXAMINE ALL DRAWINGS CAREFULLY PRIOR TO SUBMITTING A BID. 15, WHEREVER NOT SIMILAR METALS ARE TO BE JOINED, CONTRACTOR WILL BE REQUIRED TO FURNISH, INSTALL AND/OR A DI —ELECTRIC FITTING SHALL BE PROVIDED TO CONNECT BOTH CONNECT WITH APPROPRIATE SERVICES ALL PLUMBING ITEMS TYPES OF PIPES, SHOWN ON ANY OF THE ARCHITECTURAL, AIR CONDITIONING, 16, PLUMBING CONTRACTOR SHALL PROVIDE AIR CONDITIONING ELECTRICAL AND SPRINKLER DRAWINGS WITHOUT ADDITIONAL EXPENSE TO THE OWNER. IF DISCREPANCIES CONFLICTS CONDENSATE DRAIN AND TRAP, SEE AIR CONDITIONING PLANS , , INTERFERENCE OR OMISSIONS OCCUR BETWEEN DRAWINGS, FOR LOCATION OF UNITS AND DRAINS, NOTIFY IN WRITING THE ARCHITECT/ ENGINEER IN AMPLE TIME 17, MATERIALS TO PERMIT REVISIONS BEFORE THE BIDS ARE SUBMITTED. A. COLD WATER PIPING DOWNSTREAM OF WATER METER SHALL BE 4.INSTALL MATERIALS AND EQUIPMENT IN A NEAT AND FIRST TYPE "L" COPPER BELOW GROUND AND TYPE "M" COPPER ABOVE CLASS WORKMANLIKE MANNER, THE OWNER RESERVES THE GROUND. RIGHT TO DIRECT REMOVAL AND REPLACEMENT OF ITEMS WHICH, B, COLD WATER PIPES INSIDE OF SLAB SHALL NE TYPE "K" SOFT IN HIS OPINION, DO NOT PRESENT A NEAT AND WORKMANLIKE COPPER INSTALL INSIDE POLYETHYLENE CONDUIT. NO JOINTS APPEARANCE, REMOVAL AND REPLACEMENT IS TO BE DONE PERMITTED INSIDE SLAB. IMMEDIATELY WHEN DIRECTED BY THE OWNER IN WRITING, AT THE SOLE EXPENSE OF CONTRACTOR. C. SANITARY WASTE AND VENT 4"0 AND SMALLER SHALL BE P.V.C., SCHEDULE 40. 5, START OF WORK BY CONTRACTOR SHALL BE CONSIDERED AS D. STORM LINES INSIDE BUILDING SHALL BE P.V•C. SCHEDULE 40 ACCEPTANCE BY HIM OF ALL CLAIMS OR QUESTIONS AS TO SUITABILITY OF THE WORK OF OTHER. TRADES OR OTHER E, IN COASTAL AREAS ALL SANITARY AND STORM PIPING OUTSIDE OF CONTRACTORS TO RECEIVE HIS WORK. THIS CONTRACTOR BUILDING SHALL BE SCHEDULE 40, PVC, SHALL REMOVE AND REPLACE, AT HIS EXPENSE, ALL PLUMBING F. CONDENSATE DRAIN PIPE SHALL BE SCHEDULE 40, PVC PIPE WORK WHICH MAY HAVE TO BE REMOVED BECAUSE OF AND FITTINGS. INTERFERENCE WITH OTHER TRADES. G. WATER HEATER RELIEF AND DRAIN LINE SHALL BE TYPE T' COPPER, 6. THIS CONTRACTOR SHALL OBTAIN AND PAY ALL INSURANCE, MIN 3/4" DIA. FEES, PERMITS , ASSOCIATION DUES, ROYALTIES AND TAXES OF WHATEVER NATURE SHALL APPLY TO THIS WORK. HE SHALL ALSO FIRE RATED PENETARATION NOTE PAID ALL THE INSPECTION FEES AS MAY REQUIRED BY LAW OR WHEN ARE PENETRATION OF PIPING OCCUR, SHALL BE PROTECTED ORDINANCE AND SHALL KEEP THE OWNER HARMLESS FROM ANY DAMAGE AND EXPENSE ARISING FROM ANY VIOLATION OF LAWS, BY ASSEMBLY No. W—L-20ns, UL APPROVED RULES OR ORDINANCES. 1 /2"0 CWS 1 /2"0 HWS HOT WATER HEATER DETAIL N.T.S. INSTANT HWH.#1 IN COMPLIANCE F.B.0 2007 SHALL BE "TITAN" TANKLESS WATER HEATER. MODELS AS FOLLOW: EWH MODEL N-120 11.8 KW/240/1/60 WEIGHT: 5 POUNDS DIMENSIONS: 6-1/4" x 9-5/8' x 2-3/4" ENERGY EFFICIENCY: UP TO 97.0% NO R.V.D OR OVER FLOW REQUIRED AS PER MANUFACTURE SPECS. NOTE: ALL SANITARY PIPE 2 1/2"0 OR SMALLER SHALL RUN 0 1 /4" SLOPE PER L.FT. 3" AND LARGER 0 1 /S" SLOPE PER L.FT. NOTE ALL TUB AND SHOWER SHALL BE ANTISCALDING VALVE 1 110', (TYPICAL) NOTE: SHOWERS AND TUB/SHOWER COMBINATIONS SHALL BE EQUIPPED WITH CONTROL VALVES OF THE PRESSURE BALANCE. THE HIGH LIMIT STOPS SHALL BE SET TO LIMIT WATER TEMPERATURE TO A MAXIMUM 120 F(49 C) SITE INVESTIGATION NOTE EXAMINATION OF CONTRACT DOCUMENTS AND SITE OF WORK: THE BIDDER IS REQUIRED, R SUBMITTING IS PROPOSAL, TO VISIT I F PROPOSED WORK AND BEFORE S B T11NG H L, THE SITE 0 THE P O D FAMILIARIZE HIM OR HERSELF WITH THE NATURE AND EXTENT OF THE WORK AND ANY LOCAL CONDITIONS THAT MAY IN ANY MANNER AFFECT THE WORK TO BE DONE AND EQUIPMENT, MATERIALS AND LABOR REQUIRED THEREFORE. SINCE THE WORK INVOLVES NEW AND/OR EXISTING BUILDINGS, SYSTEMS AND FACILITIES, SPECIAL CONSIDERATION SHALL BE GIVEN TO EXAMINATION OF WORKING CONDITIONS, NEW FACILITIES AND ALL BUILDING STRUCTURES FAMILIARIZE TO HIMSELF WITH ALL EXISTING CONDITIONS. SLIGHT VARIATION OF ROUTING AND OR CONSTRUCTIONS SHOULD BE ANTICIPATED BY THIS CONTRACTOR TO AVOID CONFLICTS WITH OTHER TRADES. THESE VARIATIONS ARE EXPRESSLY INCLUDED AS PART OF THE WORK WHENEVER REQUIRED AT NO ADDITIONAL COST TO THE OWNER. IGNORANCE ON THE PART OF THE CONTRACTOR WILL IN NO WAY RELIEVE HIM OF THE OBLIGATIONS AND RESPONSIBILITY ASSUMED UNDER THIS CONTRACT. WATER PROOF DRYWALL THIN SET(SETTING BED) UPPER SECTION OF DRAIN TILE ADJUSTS TO HEIGHT OF TILE LOCKING RING OF DRAIN CONCRETE MORTAR (BOLTS TO HOLD DOWN LINER) BIT RED) IC G of i.�x:p j.('', _ ,,,'-:S;t•> '.:'••t',.,2rt4y:^,�.:5.5.'»"ir'.{a,':1�;�:',. '.'�V 'I;,.,t.7r'.,i•tS.Y:•'�.�.ta.r:��v;'r.^�':1 i,i.�i:wns,a`ti'y,`,r�.K! '""��!;,:�N, Wky:r ,'�, .,,e.; t:•. :,h a, ;4:.."N�;�i:?!y«. 17 PEA GRAVEL TO SHO R PAN LINER SUIFLOOR TILE SHOWER DRAIN COVER WEEP (WOOD OR CONCRETE) MOUNTED ON TOP HOLES, OF SURFLOOR DRAIN PIPE shower installation DETAIL N IS. FIXTURE CONNECTION SCHEDULE ITEM WASTE & SOIL WATER COLD HOT WATER CLOSET 3" 1/2" — TUB 2" 1/2' 1/2" WHIRLPOOL 2" 1/2" 1/2" BIDET i-1/4" 1/2" 1/2" LAVATORY 1-1/4" 1/2" 1/2" KITCHEN SINK 1-1/2" 1/2" 1/2" DISHWASHER 1" hose — — 1/2" CLOTHES WASHER 2" 1/2" 1/2" HOSE 1111 — — 1/2" FLOOR DRAINS 2" MIN. 1/2" — — SHOWER 2' 1/2" 1/2' REFRIGERATOR _ _ 1/2" NOTE: PROVIDE ANTI SCALD VALVE @ EACH SHOWER AND TUB NOTE: ALL TRAOS SHALL BE CONSISTENT W/FIXTURE OUTLET SIZE. PLUMBING PLAN SCALE: 1 /4"= V-0" MAXIMUM FLOW RATE AND CONSUMPTION FOR PLUMBING FIXTURES AND FIXTURE FITTINGS PLUMBING FIXTURE OR FIXTURE FITTING MAXIMUM FLOW RATE OR QUANTITY LAVATORY, PRIVATE 1.0 GPM 0 60 PSI LAVATORY, PUBLIC 0.5 GPM 0 GO PSI LAVATORY, PUBLIC, METERING OR SELF —CLOSING 0.25 GALLONS PER METERING CYCLE SHOWER HEAD 1,5 GPM 110 PSI SINK FAUCET 1.0 GPM 6 60 PSI URINAL 0.5 GALLON PER FLUSHING CYCLE WATER CLOSET 1.28 GALLON PER FLUSHING CYCLE FIELD COORDINATION NOTE EVERY CONTRACTOR SHALL COORDINATE IN FIELD W/ OTHER TRADES PRIOR START OF CONSTRUCTION FOR THE STRUCTURAL BEAM, SLAB, TRUSSES, ARCHITECTURAL DETAILING AS PRE—FAB FORMS, REVELING, CEILINGS, ARCH WITH THE LOCATION OF CEILING OR WALL GRILLES, DUCT WORKS, RETURN GRILLES, LIGHTING FIXTURES, SWITCHES, RECEPTACLES OR ANY OTHER DEVICES. AND TO NOTIFY ARCHITECT/ ENGINEERS IF ANY CONFLICT OCCUR PRIOR ITS INSTALATION, NO ADDITIONAL COST TO OWNER CAN BE APPLIED. 18 FU) TO BE EXIST. CONNECTED TO EXIST. TERRACE 3"0 SEWER LINE THAT GOES TO SEPTIC TANI 2WAY FCO. tEXISL 3"0 SEWER LINE THAT GOES TO SEPTIC TANK J VERIFY EXACT. LOC. 0 FIELD. I _ REF SH 3" R NGE FU) 2" 2"0 VENT TO BE NEW EXIST. DINING (4F O CONNECTED TO I V RIFY I L KITCHEN ROOM EOXACT NEW° BAH 1 IST 1-1 "0 DW I ATH (1 L— - J — 2N0(1FU) 3"4 (4FU) A HW (0) k NEW W N-120 1/2" CW do HW DOWN AND RUN IN LOW PART. 3"0 Y4" CWS RUN ON TO SERVICE KS. AND DW. (3FU) CROWL SPACE FOR IN ON NEW POSITION I'w (OH) VFI J: i 1/2" CW is HW DOWN EXIST AND RUN IN WALL TO LIVING 2"0 VT SERVICE WASHER MACH. ROOM EXIST BEDROOM CAW fl EXIST. PORCH WATER PIPING SIZE-2 01 1/2"0 CW/HW 02 1 /2"0 CW (1) 3/4"0 CW,1/2"0 HW 0 3/4"0 CW/HW (3) 1/2"0 HW (0 3/4"0 CWS (2) 1 "0 CWS HAMMER ARRESTOR: — AMTROL, MODEL 500 — INSTALL IN ACC. LOCATION. — CONNECTION SIZE: 1/2" NPT — HEIGHT: 4-1/2" DIAMETER: 3-3 B" MAX. PRESSURE: 150 PSI MAX. TEMP: 200' IT MAX. SHOCK PRESSURE: 200 PSI TO BE INSTALLED IN CWS AND HWS HIGH POINT FOR EACH GROUP OF FIXTURE SERVICING. PLUMBING SCOPE OF WORK: THIS JOB CONSIST. OF INTERIOR REMODELING FOR EXISTING HOUSE. THERE IS PLUMBING DWG. BECAUSE ONE ADDITIONAL BATH. AND KITCHEN do WASHER RELOC, EWH HAVE BEEN REPLACED BY IWH, & RELOCATED TO BELLOW LAV ON NEW BATH, NEW SEWER LINES HAVE BEEN REPRESENTED TO EXIST. LINE THAT. GOES TO SEPTIC. TANK. ON REAR OF THE PROPERTY. NO AREA HAVE BEEN ADDED TO THE HOUSE AND IT IS THE NUMBER OF BEDRROMS. THE SEPTIC. SYSTEM REMAIN THE SAME. EXIST BEDROOM EXIST EXIST CL CL EXIST BEDROOM L---------------------� EXIST. SOV. IN VERTICAL I 3/4"0 C.W. EXIST FROM WATER METER IN FRONT OF PROPERTY I/ G •v Uw V•• • y • • W Y � U . r Y • •' Y REVISION By • w r o0o • •r • w U• wY r� u • r Y Y w � u � Y V Y � • Y r Y •Y• Yr• • • •• l ,•• • Y r ti • o Y • V � a- �"��� b - l7 RODRIGUEZ PROFESSIONA DESIGN CORP 9351 Fountainebleau Blvd B-204 MIAMI .FL. 33172 PHONE: 305 634 8466 Fax: 305 638 4710 C.A. 27469 Wilbert Rodriguez Professional Engineer P.E. No 65688 i FO�'s. tJo. 6 •. N rE o T TATO F P <�p%�GR1D�:.•��:� �U Y ar CL 0 Z L k U W W W W Z M J J W C'7 " J O ULL 2 p w; ❑ W Of w - � W w �_ d MENEWO W �Z) DATE: 10-31-14 SCALE: AS SHOWN DRAWN: WR/SR JOB: SHEET s: