6129 SW 70 ST EB-11-038-010 DF-IOLIT (ON i�1CTE-5: D i"IOLITION FLAN LEGEND Revisions:
EXISTING REINFORCED GONG. A
1. THIS DRAWING IS ONLY TO ASSIST IN SHOWING 5. CONTRACTOR 15 TO PROTECT ALL UNDER- 5. CONTRACTOR IS TO SAW-CUT ALL OPENINGS IN 10. CONTRACTOR IS TO COORDINATE 13. DEMOLITION I5 DENOTED BY BROKEN 15. CONTRACTOR TO SURVEY PROJECT AREA COLUMN OR CONCRETE WALL
TO REMAIN
THE SCOPE OF DEMOLITION WORK AND IS NOT GROUND OR OTHER CONCEALED UTILITIES HE IS CONCRETE BLOCK WALLS IF 'REQUIRED. DEMOLITION WORK WITH ADMINISTRATION AND LINES. PRIOR TO COMMENCEMENT OF WORK. NOTE
INTENDED TO INDICATE ALL DEMOLITION. TO INSPECT CEILING AND CHASES TO ASSURE CONTRACTOR SHALL NOT DEMOLISH OPENINGS IS TO GIVE SUFFICIENT ADVANCE NOTICE OF 14. FOR REMOVAL OF FIXTURES AND EQUIPMENT AND REPAIR ANY DAMAGE TO AREAS NEW CONCRETE COLUMN
CONTRACTOR SHALL REMOVE ALL EXISTING PROPER IDENTIFICATION OF UTILITIES. WITH SLEDGE HAMMER UNTIL OUTLINES HAVE THE BEGINNING OF WORK IN EACH EXISTING SEE ARCHITECTURAL, PLUMBING, MECHANICAL WHERE WORK IS GOING TO BE PERFORMED.
BEEN CUT. FLOOR TO ADMINISTRATION (12 HOUR AND ELECTRICAL DRAWINGS. NOTIFY OWNER AND ARCHITECT WITH A LIST EXISTING CONC. COLUMN Q
ITEMS AS REQUIRED TO COMPLETE THE JOB. MECHANICAL AND/OR ELECTRICAL MINIMUM) OF WORK PRIOR TO CONTRACT. ® TO B£ REMOVED CONTRACTOR ARE TO GAP THEM AS REQUIRED. 15. PREPARE EXISTING CONCRETE SLAB AS REQ_
2. NOT ALL ITEMS TO BE DEMOLISHED ARE 9. RENOVATION WORK MAY ENTAIL INTERVENTIONS l�
SHOWN ON THE PLAN. CONTRACTOR SHALL BE IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF II. CONTRACTOR SHALL VERIFY EXACT LOCATION BY GRINDING, LEVELING WITH ARDEX LEVELER NEW CONCRETE WALL
19
RESPONSIBLE FOR PERFORMING A WALK-THRU ro. OPENINGS LEFT THROUGH RATED AND SMOKE WORK, INCLUDING WORK ABOVE AND/OR BELOW OF EXISTING CONCRETE COLUMNS IN AREAS AS PER MANUFACTURERS SPECIFICATIONS. THIS SET OF DRAWINGS IS TO BE USED AS A UNIT_
OF THE PROJECT PRIOR TO SUBMITTING A 51D PARTITIONS DUE TO REMOVAL OF DUCTWORK THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY WHERE WALLS ARE BEING REMOVED AND MATCH EXISTING SLAB ELEVATION AS CONTRACTOR IS RESPONSIBLE FOR ALL DISCIPLINES, EXISTING WALL OR
T *- T T INFORM ARCHITECT OF ANY CONFLICTS REQUIRED TO RECEIVE NEW SCHEDULED 6 SHOULD INCLUDE EVERYTHING THAT IS NEEDED FOR PARTITION TO REMAIN
O THE OWNER FOR IDENTIFYING POSSIBLE. CONDUIT SHALL BE CLOSED (BOTH H SIDES) REQUIRE WORK INVOLVING REMO T E UTILITY MAKING ALL SYSTEMS WORK. EXAMPLE- IF A SINK IS
CRITICAL ITEMS, NOT OR INCORRECTLY AS PER A.H.G.A. PENETRATION DETAILS. LINES (ELECTRICAL MECHANICAL, PLUMBING, BEFORE ANY WALLS ARE REMOVED SO THAT FLOORING MATERIAL. SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED WALL OR PARTITION WITH
ADDRESSED, WHICH REQUIRE REMOVAL/ GOMMUNIGATIONS). ANY WORK IN AREAS
A/E CAN INSPECT THEM FOR CLARIFICATION lro VERIFY WITH CIVIL, PLUMBING, MECHANICAL THAT THE G.G. IS PROVIDING EVERYTHING NEEDED, EXISTING DOOR TO REMAIN
RELOCATION. OUTSIDE OF THE IMMEDIATE SCOPE OF WORK PRIOR TO PROCEEDING WITH WORK. AND ELECTRICAL DRAWINGS ITEMS TO BE A/E WILL PROVIDE THEM WITH THE UNDERSTANDING OR
3- PROVIDE SAFETY FEATURES DURING WORK AS 1. REMOVE ALL EXISTING ACOUSTICAL TILE CLG. SHALL BE ALL-INCLUSIVE, PROVIDING ALL _ EXISTING WALL E
� REMOVED/RELOCATED IN CASE OF THAT THERE WILL BE NO ADDITIONAL COST TO OWNER. � PARTITION TO BE REMOVED
GALLED FOR IN SPECS, APPLICABLE CODES, AND SUSPENDED SYSTEMS IN THE STRUCTURES, UTILITIES, FINISHES AND EQUIP. CONFLICT. a N
REQUIRED TO RESTORE THE AREA TO FULLY 12_ PATCH AND REPAIR ALL EXISTING SURFACES
RULES AND REGULATIONS HAVING JURISDICTION RENOVATION AREA AS REQUIRED FOR DAMAGED BY DEMOLITION AND/OR T T
OF THE PROJECT. INSTALLATION OF WORK TO BE DONE. OPERATIONAL CONDITIONS, TO FULLY 1-I. DESTINATION OF ALL EXISTING EQUIPMENT, 20. SEE STRUG URAL DRAWINGS FOR ADD 1-1 IONAL r \ < '^
INSTALLATION OF NEW ELECTRICAL CONDUITS, WALL OR PARTITION WITH .�
COMPLYING RATING INTEG-sRITY, AND TO MEET PLUMBING FIXTURES, DOORS AND FRAMES, ETC. INFORMATION REGARDING PARTIAL DEMOLITION, EXISTING DOOR TO BE REMOVED [- a$
COORDINATE REMOVAL WITH ELECTRICAL GAS PIPING, ETC.. AS REQUIRED TO MATCH 0.0
OWNER'S APPROVAL ALL WORK AS DESCRIBED OBE REMOVED SHALL BE COORDINATED INCLUDING BUT NOT LIMITED TO GMU CELL
4. CUT, REMOVE, PATCH, ALTER AND REFINISH CONTRACTOR REGARDING EXISTING LIGHTING ADJACENT SURFACES AND/OR AS REQUIRED
FIXTURES ETC.. REPLACE CEILING IN THIS NOTE IS TO BE PART OF HE BASE WITH THE ONNER. REINFORCEMENT
EXISTING CONSTRUCTION AS REQUIRED TO CONTRACT PRICE, OR CONTRACT CONTINGENCY FOR NEW SCHEDULED FINISHES.
LEAVE WORK COMPLETE AND IN SATISFACTORY ACCORDINGLY AFTER COMPLETING OF WORK.
MANNER_ ALLOWANCE FOR SUCH WORK. -1 (SEE DEMOLITION LEGEND) O
DEMOLITION SYMBOL
W >
DENOTES PORTION OF EXISTING
CONCRETE SLAB AND/OR JOISTS V
TO BE REMOVED. SEE STRUCTURAL
DE1'-IOL I I ION NOTES: �
pq 0
I
O REMOVE EXISTING DOOR AND FRAME. V
� 1
SEE DETAIL ------- SHEET A- ------ v z
OREMOVE EXISTING PARTITION WALL
EXISTINCs DENOTES STAIR
AS REQUIRED. ALL INTERIOR PARTITIONS AND
SATELLITE AND ENCLOSURE AT FURRING TO BE RE"10vED. (TYP)
REMOVE PLUMBING FIXTURES AND CAP 4 H
1 FRAMING SECOND FLOOR O ALL PLUMBING LINES ABOVE CEILING OR WITHIN a
SUPPORT TO BE I WALL AS REQUIRED.
DEMOLISHED (SEE ENGINEERING DRAWINGS)
REMOVE EXISTING FLOOR FINISH
r AS REQUIRED. PATCH AND LEVEL TO z a
C _: RECEIVE NEW FINISH FLOOR
r-a
�C �C �/ REMOVE EXISTING CANVAS CANOPY. x F
s
I�_ � yyy.=a;
PATCH AND FINISH TO MATCH EXISTING
2>'O 2� SEE NEW ARCH. AND STRUCT- DRAWINGS
FOR NEW CANOPY LOCATION.
o
REMOVE EX15TING CONCRETE SLAB a x
O
OSAW GUT EXISTING SLAB TO PROVIDE 19
ACCESS UNDERGROUND FOR THE
EXISTING PITCH PAN FOR REFRIGERANT �- INSTALLATION OF THE DRAINAGE LINES.
-� LINES PENETRATIONS TO BE '�F � I - _ SEE PLUMBING DRAWINGS FOR
�F J DEMOLISHED kL � COORDINATION_ O
-A REMOVE EXISTING RAILING AT STAIR
EXISTING FOR DISCONNECT PAN
O BE EMOLRISHEDMING O LOCATIONS.
D d
SCUP PER TO � V
REMAIN (TYP.) PROVIDE NEW
O MASONRY OPENING (SEE
f— I L — �- — I DOOR SCHEDULE FOR SIZE). W
EXIST. I EXIST. I I REMOVE EX15TING CONC. SLAB AS REQUIRED FOR NEW CONC. FOOTING.
IR
TU ' I RTU I (SEE - STRUCTURAL DRAWINGS FOR SIZE)
PROVIDE NEW WALL. SEE WALL TYPE
2EJ 2E✓ I $
OREMOVE EXISTING SOFFI T
EXIST ING VE NT I REMOVE ALL EXISTING FINISHES, INCLUDING O
TO DEMOLISHED 19 CEILING TILES,GRID, SUPPORT SYSTEM,
SOFFITS AND FLOORING.
OREMOVE EXISTING ELECTRICAL OUTLETS,
SWITCHES, LIGHT FIXTURES AND DEVICES.
❑ ❑ (SEE ENGINEERING DRAWINGS)
EXISTING VENT O REMOVE EXISTING STRUCTURAL BEAM
I TO DEMOLISHED ~�~ I z
16 NEW PLUMBING FIXTURES (TYPICAL).
O REMOVE EXISTING STUCCO BAND
ON EXTERIOR ELEVATIONS. Gr
SEE EXTERIOR ELEVATIONS SHEET. `J
REMOVE EXISTING BLOCK WALL z
18 AS SHOWN. O
EXISTING VENT � WALL T
AS INDICATED.
OF BLOCK
2(o TO DEMOLISHED 2� 20 REMOVE EXISTING WINDOW/STOREFRONT O
(TYP.) -
�_ ` 21 REMOVE EXISTING A/C.
SEE MEP DRAWINGS. �nL�
OREFER TO SITE PLAN FOR
SCOPE OF DEMOLITION WORK AT SITE. LL"
rI 7 0
�,, L, I 23 REMOVE EXISTING METAL SHED. O
�� 1�Is� REFER TO 517E DEMOLITION PLAN-
EXISTING PITCH PAN TO I 24
REMOVE EXISTING CABINET.
SUPPORT FRAMING FOR
DISCONNECT TO BE 25 REMOVE EXISTING ROOF TOP CONDENSING UNIT_
DEMOLISHED I AND CURB. PATCH AMC) REPAIR ROOF
PENETRATIONS_ SEE ME-P. DRAWING
26 REMOVE EXISTING EXHAUST FAN. PERMIT SET
REMOVE EXISTING CURB- DRAWAh GAG
PATCH AND REPAIR ROOF PENETRATION
LEN
EXISTING VENT ACCORDANTLY Gl.IECKED,
` TO DEMOLISHED — — — I — _ — I DAVE: 04-25-2011
_ EXISTING OVERHANG
EXISTING PITCH PAN FOR TO REMAIN. SCALF. AS SHOWN
REFRIGERANT LINES
PENETRATIONS TO BE
2rJ 2� DEMOLISHED SEAL 0 -
r
TOTE:
Ld r;
THE INTENT OF THIS DEMOLITION IS TO REMOVE T '. .. �
ALL INTERIOR DOORS, PARTITIONS, FINISHES,
' FIXTURES, EQUIPMENT AND RELATED SYSTEM
COMPONENTS AND TO LEAVE ONLY THE
STRUCTURAL SHELL READY FOR NEW BUILD OUT. Sheet No.
S TOfR NCx THIS IS IN ADDITION TO AND COMPLEMENTARY
IN STOi�AC-s�
CTYP.) TO THE SPECIFIC DEMOLITION ITEMS INDICATED
RO O IDEI`�IOLITION F NORTH A ON THIS PLAN. A-3
/�
DN OF
SCALE: 1/4" = V-0"
JOB f 201115