6129 SW 70 ST EB-11-038-009 C ENEI,RAL DEl" L ITION NO T E5: -~
D�1"fOL f � f ON FLAN LEr--;END Revisions:
EXISTING REINFORCED GONG.
i. THIS DRAWING 15 ONLY TO ASSIST IN SHOWING 5. CONTRACTOR 15 TO PROTECT ALL UNDER- S. CONTRACTOR iS TO SAW-GUT ALL OPENINGS iN 10. CONTRACTOR iS TO COORDINATE 13. DEMOLITION 15 DENOTED Bl' BROKEN 18. CONTRACTOR TO SURVEY PROJECT AREA ® COLUMN OR CONCRETE WALL
THE SCOPE OF DEMOLITION WORK AND 15 NOT GROUND OR OTHER CONCEALED UTILITIES HE 15 CONCRETE BLOCK WALLS IF REQUIRED. DEMOLITION WORK WITH ADMINISTRATION AND LINES. NOT T TO MAIN
PRIOR TO COMMENCEMENT OF WORK. E
INTENDED TO INDICATE ALL DEMOLITION. TO INSPECT CEILING AND CHASES TO ASSURE CONTRACTOR SHALL NOT DEMOLISH OPENINGS 15 TO GiVE SUFFICIENT ADVANCE NOTICE OF 14. FOR REMOVAL OF FIXTURES AND EQUIPMENT AND REPAIR ANY DAMAGE TO AREAS NEW CONCRETE COLUMN
CONTRACTOR SHALL REMOVE ALL EXISTING PROPER IDENTIFICATION OF UTILITIES. WITH SLEDGE HAMMER UNTIL OUTLINES HAVE THE BEGINNING OF WORK IN EACH EXISTING SEE ARCHITECTURAL, PLUMBING, MECHANICAL WHERE WORK IS GOING TO BE PERFORMED. Q
ITEMS AS REQUIRED TO COMPLETE THE JOB. MECHANICAL AND/OR ELECTRICAL BEEN CUT. FLOOR TO ADMINISTRATION (12 HOUR AND ELECTRICAL DRAWINGS. NOTIFY OWNER AND ARCHITECT WITH A LIST T R 9 R EXISTING CONC. COLUMN
CONTRACTOR ARE TO GAP THEM AS REQUIRED. MINIMUM) OF WORK PRIOR TO CONTRACT. ® TO BE REMOVED Q
2. NOT ALL ITEMS O BE DEMOLISHED ARE CONTRACTOR
RENOVATION WORK MAY ENTAIL INTERVENTIONS 15. PREPARE EXISTING CONCRETE SLAB AS EQ.
SHOWN ON THE PLAN. CONTRACTOR SHALL BE IN AREAS OUTSIDE OF THE IMMEDIATE SCOPE OF 11_ CONTRACTOR SHALL VERIFY EXACT LOCATION BY GRINDING, LEVELING WITH ARDEX LEVELER NEW CONCRETE WALL
RESPONSIBLE FOR PERFORMING A WALK-THRU 6. OPENINGS LEFT THROUGH RATED AND SMOKE OF EXISTING CONCRETE COLUMNS IN AREAS AS PER MANUFACTURERS SPECIFICATIONS. 19" THIS SET OF DRAWINGS IS TO BE USED AS A UNIT.
WORK, INCLUDING WORK ABOVE AND/OR BELOW CONTRACTOR IS RESPONSIBLE FOR ALL DISCIPLINES, EXISTING WALL OR
OF THE PROJECT PRIOR TO SUBMITTING A BID PARTITIONS DUE TO REMOVAL OF DUCTWORK THE FLOOR LEVEL WITHIN THE SCOPE. IT MAY WHERE WALLS ARE BEING REMOVED AND MATCH EXISTING SLAB ELEVATION AS
TO THE OWNER FOR IDENTIFYING POSSIBLE CONDUIT SHALL BE CLOSED (BOTH SIDES) REQUIRE WORK INVOLVING REMOTE UTILITY INFORM ARCHITECT OF ANY CONFLICTS REQUIRED TO RECEIVE NEW SCHEDULED d SHOULD INCLUDE EVERYTHING THAT 15 NEEDED FOR PARTITION TO REMAIN
CRITICAL ITEMS, NOT OR INCORRECTLY AS PER A.H.C.A. PENETRATION DETAILS. LINES (ELECTRICAL MECHANICAL, PLUMBING, BEFORE ANY WALLS ARE REMOVED SO THAT FLOORING MATERIAL. MAKING ALL SYSTEMS WORK. EXAMPLE: IF A SiNK IS Q
SHOWN IN THE ARCHITECTURAL PLANS, IT IS ASSUMED WALL OR PARTITION WITH
ADDRESSED, WHICH REQUIRE REMOVAL/ COMMUNICATIONS)_ ANY WORK IN AREAS A/E CAN INSPECT THEM FOR GLARIFIGATiON l
oo VERIFY WiTH CIVIL, PLUMBING, MECHANICAL THAT THE G.G. IS PROVIDING EVERYTHING NEEDED, EXISTING DOOR TO REMAIN
RELOCATION. OUTSIDE OF THE IMMEDIATE SCOPE OF WORK PRiOR TO PROCEEDING WiTH WORK. AND ELECTRICAL DRAWINGS ITEMS TO BE A/E WILL PROVIDE THEM WITH THE UNDERSTANDING
SHALL SE ALL-INCLUSIVE, PROVIDING ALL T T ------- EXISTING WALL OR
3. PROVIDE SAFETY FEATURES DURING WORK AS 1_ REMOVE ALL EXISTING ACOUSTICAL TiLE CLG. REMOVED/RELOCATED iN CASE OF THAT THERE WILL BE NO ADDITIONAL COS� �O OWNER
GALLED FOR IN SPECS, APPLICABLE CODES, AND SUSPENDED SYSTEMS IN THE STRUCTURES, UTILITIES, FINISHES AND EQUIP. CONFLICT. ---�---- PARTITION TO BE REMOVED
RULES AND REGULATIONS HAVING JURISDICTION RENOVATION AREA AS REQUIRED FOR
REQUIRED TO RESTORE THE AREA TO FULLY 12. PATCH AND REPAIR ALL EXIS T ING SURFACES
OPERATIONAL CONDITIONS, TO FULLY DAMAGED BY DEMOLITION AND/OR
OF THE PROJECT. INSTALLATION OF WORK TO BE DONE. T T 11. DESTINATION OF ALL EXIST EQUIPMENT, 20. SEE STRUCTURAL DRAWINGS FOR ADDITIONAL
COMPLYING RATING INTEGRITY, AND TO MEET INSTALLATION OF NEW ELECTRICAL CONDUITS, ``♦ WALL OR PARTITION WITH r_,
COORDINATE REMOVAL WITH ELECTRICAL T PLUMBING FIXTURES, DOORS AND FRAMES, ETC. INFORMATION REGARDING PARTIAL DEMOLITION, w C"'
OW'NER'S APPROVAL ALL WORK AS DESCRIBED GAS PIPING, ETC.. AS REQUIRED TO MA�CH N � EXISTING DOOR TO BE REMOVED ^
4. CUT, REMOVE, , ATCH, ALTER AND REFINISH CONTRACTOR REGARDING EXISTING LIGHTING TO BE REMOVED SHALL BE COORDINATED T T LIMITED� � INCLUDING BUT NOT TO CMU CELL
IN THi5 NOTE IS TO BE PART OF THE BASE ADJACENT SURFACES AND/OR AS REQUIRED — 6 r a
EXISTING CONSTRUCTION AS REQUIRED TO FIXTURES ETC_ REPLACE CEILING WITH THE OWNER. REINFORCEMENT _ ,__ r
LEAVE WORK COMPLETE AND IN SATISFACTORY ACCORDINGLY AFTER COMPLETING OF WORK. CONTRACT PRICE, OR CONTRACT CONTINGENCY FOR NEW SCHEDULED FINISHES.
^'iANNER ALLOWANCE FOR SUCH WOR!<. �o
DEMOLITION
EE DEMOLISYMBOL
ION EGEND) Z X
EXISTING CONCRETE STAIR EXISTING CONCRETE DENOTES PORTION OF EXISTING W '>4
AND ENCLOSURE TO COLUMN TO REMAIN (TYP.) CONCRETE SLAB AND/OR JOISTS
REMAIN TO BE REMOVED. SEE STRUCTURAL
z
! i S ❑ ❑ ❑ D E i 1OL. iTiON N0 ► E-5
Ii
E.
❑ ❑ ❑ O REMOVE E DETAIL DOOR WEET A FRAM_ W O
E
III 2
REMOVE REQUIRED. ALLPiNTERIOR PARTITIONS AND z
I i O FURRING TO BE REMOVED. (TYP) P.
,t REMOVE PLUMBING FIXTURES AND CAP e.
4 13
G�4 I i " O ALL PLUMBING LINES ABOVE CEILING OR WITHIN
WALL AS REQUIRED. 4 vii e7vG
Gee 13 i4 (SEE ENGINEERING DRAWINGS) a
4 REMOVE EXISTING FLOOR FINISH
(TYP.) AS REQUIRED. PATCH AND LEVEL TO
1 (TYP.) RECEIVE NEW FINISH FLOOR-
DN OREMOVE
H AND!FINISH TO MATCHAE EXISTING ►-+
SEE NEW ARCH. AND STRUCT. DRAWINGS F
FOR NEW CANOPY LOCATION. a
` REMOVE EXISTING CONCRETE SLAB r O
1 �a x
r SAW CUT EXISTING SLAB TO PROVIDE
i I I I 1 t I i ACCESS UNDERGROUND FOR THE
2 /� 1 ! r i t / t i INSTALLATION OF THE DRAINAGE LINES.
(TYP.) ♦ i 21 I t I i I / I �I 1 i t \ ——, r_______________________ SEE PLUMBING DRAWINGS FOR
�,�' ♦ / I i 21 I ! i ♦� / 1 t COORDINATION.
i I I I i i `� I I 1 REMOVE EXISTING RAILING AT STAIR O
L_J I I i 1 I i 11 L_„� ! i �\ i I Q LOCATIONS.
----------------------- ------- 1 \J L--JAL----1 t-� �'J L`L -"'-� 1 �_=�==-J 1
--i------------------------- --- 1 —1 I PROVIDE NEW 4
E"'—— �"'—— ,t O MASONRY OPENING (SEE V
DOOR SCHEDULE FOR SIZE). ww''
1 T REMOVE EXISTING GONG. SLAB AS W
1� ( YP.) I ( O REQUIRED FOR NEW CONC.FOOTING. -F•+. d
(SEE STRUCTURAL DRAWINGS FOR SIZE)
i 12 4 13 14 I i I i 1 i 3 I I PROVIDE NEW WALL. SEE WALL TYPE
1 I� i- 1 r___ ( I n SHEET. s1-
I
i (TYP.) j 1 ❑ I 1 i-� �1 I I l ,, �� �j �--- � 1 I I 4 13 14
i EXISTING CONCRETE i i i ill I 3 I i ` 110 l l 1 1 11 tt REMOVE EXISTING SOFFIT. V
MN T R MAIN ! 2 I I I I (TYP_) O a
COLD O E ! i ! / � L___) ♦ i
(TYP.) I (TYP-) ! \_10 ! i/ i r— 1 \�,�,t 1 1 REMOVE ALL EXISTING FINISHES, INCLUDING
t i CEILING TILES,GRID, SUPPORT SYSTEM,
C I i •� 1 i I I 13 14 __+� L_1 SOFFITS AND FLOORING. O
REMOVE EXISTING ELECTRICAL OUTLETS,
SWITCHES, LIGHT FIXTURES AND DEVICES.
e13 3 V i i (SEE ENGINEERING DRAWINGS)
I 1 1 � ' O REMOVE EXISTING STRUCTURAL SEAM
1 I I
I 1±o
EXIST 11 CONCRETE EXISTING CONCRETE t6 NEW PLUMBING FIXTURES !TYPICAL).
1 � 1
COL TO TO REMAIN I I I I COLUMN TO REM,41N
! REMOVE EXISTING STUCCO BAND
0 1 F=— 0 ON EXTERIOR ELEVATIONS.
I / r � t � I I SEE EXTERIOR ELEVATIONS SHEET. �/
z
1 If 'i 'I 0 I I 11 REMOVE EXISTING BLOCK WALL 1:4
Ir 0 I i 3 1 -� �I 13 14 i O AS SHOWN.
1 4 13 14 1 i I � � � � I 11 I�' i � � I I i I REMOVE EXISTING PORTION OF BLOCK O
I I I � 1�' 11 �0: I p� 1100L) l
• 0 I 11 2 24 18 WALL AS INDICATED. O
I (TYP.) I I I i ! I ! I 11 REMOVE EXISTING WINDOW/STOREFRONT >w
---- '�-- o (TYP.) 2m O
r I L-------- ------ ------- m REMOVE EXISTING WINDOW
® z
O
SEA° DRAW NGS./C. O
I V
REFER TO SiTE PLAN FOR W
SCOPE OF DEMOLITION WORK AT SITE.
i II I I tl II / p
i I I I I I REMOVE EXISTING METAL SHED.
13 14 s3 REFER TO SITE DEMOLITION PLAN
t i t 4 14 11 G4) 1 14 I t I I 24 REMOVE EXISTING CABINET.
13 13 I t i t (TYP.)
1 13 � 1 II II
u 1 11 11 (TYP.) I L
i (TYP.) i I I r �-� PERMIT SET
I I 1 1
2 DRAWN GAC
♦\`1 LL=_�===3=, cr�c LEN
I—�—__--1 I I i I - 1 t (TYP.)
I I ----------------� �---- ----------1 I i ❑
04-25-2011
1� 11 r----------------- o --------� II DATE:i EXISTING 1
/T ! CONCRETE COLUMN 1� 14 f 1 2 �, AS SHOWN
TO REMAIN (TYP.) 1�
❑ tI 13 i1 SEAl
1 (-�
1
----- OF f
(TYP.) i i----- ....... �Q�
7
NOTE
9 1 XI5TING
I A CESi E THE INTENT OF THI5 DEMOLITION 15 TO v^
EL OR TO REMOVE ALL INTERIOR DOORS,'
1g �� PARTITIONS, FINISHES, FIXTURE5, 1�
REM N EQUIPMENT AND RELATED 5Y5TEM
S l i
COMPONENTS AND T O LEAVE ONLY
®� I THE STRUCTURAL SHELL READY FOR Sheet No.
I ♦lD ®o I UP 13 1� ! i 13 1� NEW BUILD OUT.
D I I OL I I 1 OI Y f=L AI �l NORTH (TYP.) 1 I THIS IS IN ADDITION TO AND A-2
I I COMPLEMENTARY TO THE SPECIFIC
SCALE: 114" = ��_0p - DEMOLITION ITEMS INDICATED ON THIS OF
PLAN.
EXISTING CONCRETE
STAIR AND ENCLOSURE
TO REMAIN JOB } 201115